Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Similar documents
ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

Instructions for Installation, Operation, Care and Maintenance

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

TECHNICAL DATA. Wet 26a. February 22, 2009

mechanical. OPERATION Rapidrop Global

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Worldwide Contacts.

TECHNICAL DATA OBSOLETE

Technical Data. Installation

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

Worldwide Contacts. Technical Data

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

TECHNICAL DATA. 319a. January 27, 2012

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Discontinued Product

Worldwide Contacts.

Series 759 FireLock Alarm Check Valve

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Care and Maintenance

Sprinkler Identification Number (SIN)

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

TotalPac 3 Wet pipe system c/w retard chamber

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

SPRINKLERS TABLE OF CONTENTS

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Sprinkler Identification Numbers

Sprinkler Identification Numbers

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

esfr dry pendent sprinkler Vk501 (k14.0)

Gas Station & C Store SECTION CWM Job No

esfr dry pendent sprinkler Vk502 (k14.0)

SECTION DRY-PIPE SPRINKLER SYSTEMS

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION DRY-PIPE SPRINKLER SYSTEMS

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

SECTION WET-PIPE SPRINKLER SYSTEMS

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

TOTALPAC2 Integrated Fire Protection System

TotalPac 3 Firecyle III Deluge Remote controlled system

Transcription:

Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0, and DN00 (European Conformity) are divided-seat ring, rubber-faced clapper, waterflow alarm valves that are intended for use in wet pipe (automatic sprinkler) fire protection systems. They are designed to automatically actuate electric and/or hydraulic alarms when there is a steady flow of water into the system that is equivalent to the discharge rate of one or more sprinklers. An optional Model RC- Retard Chamber is required for installations subject to variable pressures. It is used to help prevent false alarms associated with pressure variations in public water supplies. The Model AV--00 Alarm Check Valve Trim includes pressure gauges to monitor system pressure conditions, a by-pass check valve, a main drain valve, and an alarm test valve. The bypass check valve reduces the possibility of false alarms by permitting slow as well as small transient increases in water supply pressure through the system without opening the waterway clapper. NOTICE The TYCO Model AV--00 Alarm Check Valves and TYCO Model RC- Retard Chamber described herein must be installed and maintained in compliance with this document as well as the standards recognized by the Approval agency, in addition to any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or manufacturer should be contacted with any questions. Nominal Valve Sizes DN, mm DN0, mm DN0, mm DN0, mm DN00, mm Groove x Groove Flange x Groove Flange x Flange,0 Kg, Kg N/A, Kg, Kg, Kg, Kg, Kg, Kg, Kg, Kg, Kg, Kg, Kg, Kg TABLE A AVAILABLE VALVE END CONNECTIONS AND WEIGHTS Page of DECEMBER 0 TFP0

TFP0 Page of VALVE PARTS NO. DESCRIPTION QTY. REF. VALVE PARTS NO. DESCRIPTION QTY. REF. NO. REPLACEMENT PARTS DESCRIPTION P/N Valve Body....... NR Handhole Cover... NR Handhole Cover Gasket.......... See (a) Seat Ring........ NR Clapper.......... See (b) Clapper Facing.... See (a) or (b) Clapper Washer... See (b) Lock Nut, DN Valve...... See (b) Self-Locking Hex Cap Screw, DN0, 0 & 00 Valves.. See (b) Clapper Hinge Pin.. See (b) Clapper Hinge Pin Bushing, DN Valve...... NR DN0, 0 & 00 Valves........... NR Clapper Spring.... See (b) Handhole Cover Hex Bolt, DN Valve, /- UNC-A x -/" Long..... DN0 Valve, /- UNC-A x -/" Long..... DN0 Valve, /- UNC-A x -/" Long..... DN00 Valve, /- UNC-A x " Long......... Clapper Hinge Pin Square Head Pipe Plug, /" NPT, DN0, 0 & 00 Valves only....... CH CH CH CH CH (a) Repair Parts Kit, Includes & DN Valve......... -00-- DN0 Valve DN0 Valve................ -00-- -00--0 DN00 Valve........ -00-- (b) Clapper Assembly, Includes -, DN Valve......... -00-- Includes - DN0 Valve DN0 Valve................ -00-- -00-- DN00 Valve........ -00-- NOTES:... F x F valve shown for reference; components for G x G and F x G valves are shared. NR: Not Replaceable CH: Common Hardware CLAPPER ASSEMBLY DN VALVE CLAPPER ASSEMBLY DN0, 0 & 00 VALVES FIGURE DN, DN0, DN0, & DN00 MODEL AV--00 ALARM VALVE ASSEMBLY mm (GxG, FxG) mm (FxF, FxG) 0 mm (GxG) 0 mm (FxF, FxG) mm (GxG) mm FxF, FxG or GxG DN DN0 DN0 DN00 FIGURE DN, DN0, DN0, & DN00 MODEL AV--00 ALARM VALVE TAKE-OUT DIMENSIONS

TFP0 Page of Technical Data Sizes DN, DN0, DN0, and DN00 Approvals The TYCO Model AV--00 Alarm Valves DN, DN0, DN0, and DN00 (European Conformity) with or without the Model RC- Retard Chamber are FM, VdS, and LPCB Approved as with European Conformity Valve Trim. Refer to Figures A through B. For more information on LPCB Approval, contact Tyco Fire Protection Products at the following office: Kopersteden TJ Enschede The Netherlands Tel: +-(0)-- Fax: +-(0)-- Alarm Valve The DN, DN0, DN0, and DN00, Model AV--00 Valves with European Conformity Valve Trim are for vertical installations (flow going up), and they are rated for use at a maximum service pressure of bar. Nominal pressure loss versus flow is shown in Graph A, and the valve take-out dimensions are shown in Figure. Flanged connections are drilled per ISO 0 (PN/) or ANSI B. (Class ). Refer to Table B. Grooved connections, as applicable, are cut in accordance with standard groove specifications for steel pipe. They are suitable for use with grooved end pipe couplings listed or approved for fire protection system service. Threaded port connections are per ISO / to readily accept the trim arrangements detailed in Figures A through B. Components of the Alarm Valve are shown in Figure. The body and Hand- Hole Cover are ductile iron. The Seat Ring is bronze. The Clapper is ductile iron. All valve sizes utilize an EPDM Clapper Facing. Retard Chamber The Model RC- Retard Chamber is cast iron. Valve Trim The Valve Trim is illustrated in Figures A through B. The Valve Trim forms a part of the laboratory approval of the Model AV--00 Alarm Valve and is necessary for the proper operation of the Model AV--00 Alarm Valve. Each package of trim includes the following items: Water Supply Pressure Gauge System Pressure Gauge Main Drain / Alarm Test Valve Bypass Check Valve Automatic Drain Valve Waterflow Pressure Alarm Switch Retard Chamber, as applicable Operating Principles When the fire protection system is initially being pressurized, water will flow into the system until the water supply and system pressure become equalized, and the Spring closes the Clapper in the Alarm Valve. Once the pressures have stabilized, the Alarm Valve is in service and the centrally located groove in the Seat Ring is sealed. Consequently, with the Alarm Check Valve set for service, there is no flow through the alarm port to the alarm devices (that is, water motor alarm and/or pressure alarm switch). When there is a steady flow of water into the sprinkler system due to a sprinkler operation, the Clapper opens as shown in Figure. Water is then permitted to flow into the centrally located groove in the Seat Ring and out through the alarm port towards the Automatic Drain Valve. When the flow from the alarm port exceeds the drain capacity of the Automatic Drain Valve, the Retard Chamber (where provided in the case of systems with variable pressure), begins to fill as a function of the amount of water that can pass through the Restriction. Subsequently, the water motor alarm and/or the pressure alarm switch will be actuated. The alarms will continue to actuate as long as the Clapper remains opened. Water in the alarm lines will automatically drain out through the Automatic Drain Valve when the Clapper closes (due to discontinuation in the flow of water into the sprinkler system). In the case of variable pressure systems, slow as well as small transient increases in water supply pressure may continue to build up in the system (via the bypass check valve) without opening the Clapper. A transient surge in supply pressure which is sufficient to only momentarily open the Clapper will not cause a false alarm, and a portion of the increase in pressure will be trapped within the system, thus reducing the possibility of another opening. Any water in the alarm line is automatically drained, further reducing the possibility of a false alarm due to a successive transient surge in supply pressure. Design Criteria In planning the installation of the TYCO Model AV--00 Alarm Valve, consideration must be given to the disposal of the large quantities of water that may be associated with draining the system or performing a flow test. The sprinkler system designer must be aware that the configuration of the piping network and its tendency to trap pockets of air (such as in the case of a peaked-roof gridded system) can affect the performance of the alarm system. Although a slight amount of trapped air is desirable to prevent significant pressure increases due to thermally induced expansion of the water, a large quantity of trapped air in a system may result in the possibility of an intermittent alarm. The possibility of an intermittent alarm condition is a consequence of the fact that the flow out of the system through the test valve or a single sprinkler is very small relative to the flow that can be passed through the valve. This difference increases with valve size. If the system were free of trapped air, flow in would equal flow out and the Clapper would always stabilize at some open position (as needed to accommodate the required flow). With trapped air in the system, however, the Clapper first opens wider since the system initially demands greater flow until the air pockets are compressed (back to nearly the supply pressure), and then it will tend to return closer to the Seat Ring. If the volume of the air pockets is excessive, flow into the system can be momentarily reduced to nearly zero (once the air pockets are compressed) and the Clapper may close, causing flow to the alarms to be shutoff. Once the Clapper has closed, sufficient water must flow out of the system before the Clapper will again A repetition of the above described condition is termed an intermittent alarm. Using a vent (which can also serve as an end-of-line Inspector s Test Connection) piped from the top of a cross main or end of a branch line at the point most remote from the alarm valve, and filling the system slowly in accordance with the steps described in the Valve Setting Procedure section, can prevent an excessive amount of air from being trapped.

TFP0 Page of Nominal Valve Size DN,,0 DN0 DN0 ANSI B. (Class ) Dim. Dim. A B 0,,,0, Nominal Dimensions in millimeters Qty. N Dim. A ISO 0 (PN) Dim. B USE ISO 0 (PN) Qty. N Dim. A,0 0,0) 0,0 ISO 0 (PN) Dim. B,0,0,0 Qty. N DN00,,,0,0,0,0 Dim. A Bolt Circle Diameter Dim. B Bolt Hole Diameter Same drilling as for B. (Class 0) and B. (Class 0). Same drilling as for BS 0 Section. (PN) and DIN (PN). Same drilling as for BS 0 Section. (PN) and DIN (PN). Qty. N Number of Bolt Holes TABLE B FLANGE DRILLING SPECIFICATIONS 0,0 NOMINAL PRESSURE DROP IN BAR 0,0 0, 0,0 0,0 0,0 0,0 DN DN0 DN0 DN00 0,0 00 00 00 000 000 000 000 000 000 FLOW RATE IN LITRES PER MINUTE (LPM) GRAPH A DN, DN0, DN0, & DN00 MODEL AV--00 ALARM VALVE NOMINAL PRESSURE LOSS VERSUS FLOW

TFP0 Page of RETARD CHAMBER RESTRICTION WATERFLOW PRESSURE ALARM SWITCH ONCE RETARD CHAMBER FILLS, WATERFLOW PRESSURE ALARM SWITCH AND WATER MOTOR ALARM ACTUATE WATERFLOW TO WATER MOTOR ALARM UPON SPRINKLER FLOW, WATERWAY CLAPPER OPENS ALARM LINE STRAINER WATERFLOW TO SYSTEM SYSTEM PRESSURE GAUGE AUTOMATIC DRAIN VALVE BY-PASS CHECK VALVE Installation General Instructions Proper operation of the TYCO Model AV--00 Alarm Valves depends upon its trim being installed in accordance with Figures A through B, as applicable. Failure to follow the appropriate trim diagram may prevent the valve from functioning, may void the Manufacturer s Warranty, and will void listings and approvals. The Alarm Valves must be installed in readily visible and accessible locations. It is recommended that provision be made for viewing the alarm line drain water by locating the drain outlet in a readily visible area. Wet pipe fire protection systems must be maintained at a minimum temperature of C. WHEN FLOW EXCEEDS DRAIN CAPACITY, RETARD CHAMBER BEGINS TO FILL MAIN DRAIN/ ALARM TEST VALVE Step. When trimming valves in the field (that is, other than valves provided with factory assembled trim), verify all nipples, fittings, and devices are clean and free of scale and burrs before installation. Use pipe-thread sealant sparingly on male pipe threads only. Step. Plug unused alarm connections. Step. Ensure suitable disposal of alarm line and system drainage water. Direct drainage water so that it will not cause damage or result in dangerous conditions. Step. Position the alarm line drain so that there will be no danger of freezing. Step. Install the check valve in the externally mounted bypass around the waterway clapper with its arrow pointed up. WATERFLOW THROUGH SEAT RING GROOVE AND ALARM PORT FIGURE DN, DN0, DN0, & DN00 MODEL AV--00 ALARM VALVE OPERATION SUPPLY PRESSURE GAUGE Step. It is recommended that a vent connection, which may also be used as an end-of-line Inspector s Test Connection, be piped from a cross main or branch line at the point most remote from the alarm valve. Connect the vent line to the top of a cross main or to the end of a branch line. Position the vent line at the highest level of a multi-level installation. The vent connection can be used to bleed-off excessive air from the system, and therefore, minimize the possibility of a false alarm due to a transient surge in supply pressure. The contraction/ expansion associated with an excessive amount of trapped air could also cause the waterway Clapper to cycle open and shut during an inspector s test or during a discharge by a single sprinkler.

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0H; Pipe Nipple, -/" x 0mm Galvanized Steel....................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AH; Elbow F x F -/" BSP Galvanized.............................. AD; Union M x F /" BSP Galvanized.................................. A0B; Plug Male /" BSP Galvanized................................... A0D; Nipple Male /" BSP Galvanized.................................. AIH; Nipple F x M " x -/" BSP Galvanized........................... AED; Nipple F x M /" x /" BSP Galvanized........................... AIH; Nipple M x F " x -/" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0RDBD; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0D; Tee Female /" BSP Galvanized.................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 00; Alarm Valve Model AV--00 -/"/,mm G x G.................. 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 FIGURE A DN MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0H; Pipe Nipple, -/" x 0mm Galvanized Steel....................... AD; Elbow 0 M x F /" BSP Galvanized............................... AH; Elbow F x F -/" BSP Galvanized.............................. AD; Union M x F /" BSP Galvanized.................................. A0B; Plug Male /" BSP Galvanized................................... A0D; Nipple Male /" BSP Galvanized.................................. A0D; Coupling Female /" BSP Galvanized.............................. AIH; Nipple F x M " x -/" BSP Galvanized........................... AED; Nipple F x M /" x /" BSP Galvanized........................... AIH; Nipple M x F " x -/" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0RDBD; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0D; Tee Female /" BSP Galvanized.................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 00; Alarm Valve Model AV--00 -/"/,mm G x G.................. 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) POSITION FOR SUPERVISORY 0 SWITCH (ORDERED SEPARATELY) 0 FIGURE B DN MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY)

TFP0 Page of NO. 0 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... APD; Pipe Nipple, /" x mm Galvanized Steel........................ AP0H; Pipe Nipple, -/" x 0mm Galvanized Steel....................... AD; Elbow 0 M x F /" BSP Galvanized............................... AH; Elbow F x F -/" BSP Galvanized.............................. AD; Union M x F /" BSP Galvanized.................................. A0B; Plug Male /" BSP Galvanized................................... A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AIH; Nipple F x M " x -/" BSP Galvanized........................... AED; Nipple F x M /" x /" BSP Galvanized........................... AIH; Nipple M x F " x -/" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0RDBD; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0D; Tee Female /" BSP Galvanized.................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 00; Alarm Valve Model AV--00 -/"/,mm G x G.................. 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve DN-/" BSP Full Bore............................. 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 0 0 FIGURE A DN MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 0 DESCRIPTION QTY. WS0000000; Pressure Relief Hose x x,m Transparent................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0H; Pipe Nipple, -/" x 0mm Galvanized Steel....................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AH; Elbow F x F -/" BSP Galvanized.............................. AD; Union M x F /" BSP Galvanized.................................. A0B; Plug Male /" BSP Galvanized................................... A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AIH; Nipple F x M " x -/" BSP Galvanized........................... AED; Nipple F x M /" x /" BSP Galvanized........................... AIH; Nipple M x F " x -/" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0RDBD; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0D; Tee Female /" BSP Galvanized.................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 00; Alarm Valve Model AV--00 -/"/,mm G x G.................. 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) 0 0 POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) 0 FIGURE B DN MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY)

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 FIGURE A DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... A0D; Nipple Male /" BSP Galvanized.................................. A0D; Coupling Female /" BSP Galvanized.............................. AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) 0 POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) FIGURE B DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY) 0

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP00D; Pipe Nipple, /" x 00mm Galvanized Steel........................ AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve DN-/" BSP Full Bore............................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 FIGURE A DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 DESCRIPTION QTY. WS0000000; Pressure Relief Hose x x,m Transparent................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) FIGURE B DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY) 0

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 FIGURE A DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... A0D; Nipple Male /" BSP Galvanized.................................. A0D; Coupling Female /" BSP Galvanized.............................. AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) 0 POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) FIGURE B DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY) 0

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP00D; Pipe Nipple, /" x 00mm Galvanized Steel........................ AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve DN-/" BSP Full Bore............................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 FIGURE A DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 DESCRIPTION QTY. WS0000000; Pressure Relief Hose x x,m Transparent................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ AD; Elbow 0 M x F /" BSP Galvanized............................... AD; Union M x F /" BSP Galvanized.................................. AD; Plug Male /" BSP Galvanized................................... A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 0; Alarm Valve Model AV--00 "/,mm G x G.................... 00D; Check Valve, Swing Type, /"................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) FIGURE B DN0 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY) 0

TFP0 Page of NO. 0 DESCRIPTION QTY. AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... APE; Pipe Nipple, /" x mm Galvanized Steel........................ AP0E; Pipe Nipple, /" x 0mm Galvanized Steel........................ AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ APE; Pipe Nipple, /" x mm Galvanized Steel........................ AE; Elbow 0 M x F /" BSP Galvanized............................... AD; Elbow 0 M x F /" BSP Galvanized............................... AE; Plug Male /" BSP Galvanized.................................... AE; Union M x F /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... AED; Nipple M x F /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AE; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0E; Tee Female /" BSP Galvanized.................................. A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Alarm Valve Model AV--00 " G x G............................ 00; Check Valve, Swing Type, /".................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... PRE-TRIMMED VALVE ASSEMBLY 0 0 FIGURE A DN00 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 0 DESCRIPTION AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... APE; Pipe Nipple, /" x mm Galvanized Steel........................ AP0E; Pipe Nipple, /" x 0mm Galvanized Steel........................ APE; Pipe Nipple, /" x mm Galvanized Steel........................ AE; Elbow 0 M x F /" BSP Galvanized............................... AD; Elbow 0 M x F /" BSP Galvanized............................... AE; Plug Male /" BSP Galvanized.................................... AE; Union M x F /" BSP Galvanized.................................. AD; Union M x F /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. A0D; Coupling Female /" BSP Galvanized.............................. AED; Nipple F x M /" x /" BSP Galvanized........................... AED; Nipple M x F /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AE; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F /" BSP Galvanized................................... A0E; Tee Female /" BSP Galvanized.................................. A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Alarm Valve Model AV--00 " G x G............................ 00; Check Valve, Swing Type, /".................................. 00; Elbow WES mm x M........................................... ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve, DN - /" BSP Full Bore........................... 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... QTY. PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) 0 POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) 0 0 FIGURE B DN00 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITHOUT MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY)

TFP0 Page 0 of NO. 0 0 DESCRIPTION AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... AP00D; Pipe Nipple, /" x 00mm Galvanized Steel........................ APE; Pipe Nipple, /" x mm Galvanized Steel........................ AP0E; Pipe Nipple, /" x 0mm Galvanized Steel........................ APE; Pipe Nipple, /" x mm Galvanized Steel........................ AE; Elbow 0 M x F /" BSP Galvanized............................... AD; Elbow 0 M x F /" BSP Galvanized............................... AE; Plug Male /" BSP Galvanized.................................... AE; Union M x F /" BSP Galvanized.................................. AD; Union M x F /" BSP Galvanized.................................. A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... AED; Nipple M x F /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AE; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0E; Tee Female /" BSP Galvanized.................................. A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 0; Alarm Valve Model AV--00 " G x G............................ 00; Check Valve, Swing Type, /".................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 000; Ball Valve DN-/" BSP Full Bore............................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... QTY. PRE-TRIMMED VALVE ASSEMBLY 0 0 FIGURE A DN00 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER

TFP0 Page of NO. 0 0 DESCRIPTION WS0000000; Pressure Relief Hose x x,m Transparent................... AP0D; Pipe Nipple, /" x 0mm Galvanized Steel.......................... AP00I; Pipe Nipple, " x 00mm Galvanized Steel.......................... APE; Pipe Nipple, /" x mm Galvanized Steel........................ AP0E; Pipe Nipple, /" x 0mm Galvanized Steel........................ AP0D; Pipe Nipple, /" x 0mm Galvanized Steel........................ APE; Pipe Nipple, /" x mm Galvanized Steel........................ AE; Elbow 0 M x F /" BSP Galvanized............................... AD; Elbow 0 M x F /" BSP Galvanized............................... AE; Plug Male /" BSP Galvanized.................................... AE; Union M x F /" BSP Galvanized.................................. AD; Union M x F /" BSP Galvanized.................................. A0E; Nipple Male /" BSP Galvanized.................................. A0D; Nipple Male /" BSP Galvanized.................................. AED; Nipple F x M /" x /" BSP Galvanized........................... AED; Nipple M x F /" x /" BSP Galvanized........................... ADB; Nipple M x F /" x /" BSP Galvanized........................... AE; Tee M x F x F /" BSP Galvanized................................ AD; Tee M x F x F /" BSP Galvanized................................ A0RDED; Reducing Tee Female /" x /" x /" BSP Galvanized............ A0E; Tee Female /" BSP Galvanized.................................. A0I; Elbow F x F " BSP Galvanized................................. 00; Test and Drain Valve " NPT Inlet x " BSP Outlet x /" Test Facility...... 00; Nipple M x F /" x,mm Orifice x,mm......................... 0FO; Ball Valve DN-/" ISO / Full Bore PN0 Venthole Threaded M..... 0; Retarding Chamber RC-...................................... 0; Alarm Valve Model AV--00 " G x G............................ 00; Check Valve, Swing Type, /".................................. 00; Elbow WES mm x M........................................... 000; Strainer /" Bronze............................................. ; Self-Closing Drain Valve /" Brass................................ 00; Pressure Switch Model PS-...................................... 0000; Water Pressure Gauge 00 psi / bar........................... Pressure Relief Hose x x 0,m Transparent............................... QTY. PRE-TRIMMED VALVE ASSEMBLY (SHOWN WITH SEPARATELY ORDERED SUPERVISORY SWITCH) 0 POSITION FOR SUPERVISORY SWITCH (ORDERED SEPARATELY) 0 FIGURE B DN00 MODEL AV--00 ALARM VALVE TRIM ARRANGEMENT WITH MODEL RC- RETARD CHAMBER (SUITABLE FOR SUPERVISORY)

TFP0 Page of NO. DESCRIPTION QTY. P/N /" x /" Hex Bushing......... CH /" Vent Fitting........... -0--00 /" x '-0" Tubing.......... CH MODEL RC- RETARD CHAMBER PRESSURE SWITCH Trim kit is ordered separately when a Water Motor Alarm (P/N -0--0) is not installed. FIGURE ALARM VENT TRIM KIT Valve Setting Procedure NOTICE After placing a fire protection system in service, notify the proper authorities and advise those responsible for monitoring proprietary and/or central station alarms. Filling the system with water will result in operation of the associated alarms. Consequently, notify the owner and the fire department, central station, or other signal station to which the alarms are connected. The following steps are to be performed when initially setting the TYCO Model AV--00 Alarm Check Valve or after system operation due to a fire. Step. Close the Main Control Valve and open the Main Drain Valve, as well as any auxiliary drain valves. Step. Check to see that the Hand- Hole Cover bolts are tight. If not, crosstighten them. Step. Clean the strainers in the alarm line and open the Water Motor Alarm Control Valve. Step. Close the Main Drain Valve, as well as any auxiliary drain valves, and the Alarm Test Valve. Step. Open the remote cross main or branch line vent connection. Refer to Step in the Installation section. (GREEN TINT) (ROUTE TO DRAIN) Step. Slowly open the main control valve until the sound of flowing water just begins, then open the valve one more turn. Step. Close the remote branch line vent connection after the discharge of aerated water ceases and the outlet has flowed full for at least seconds. Step. Fully open the Main Control Valve. Step. Open the end-of-line Inspector s Test Connection (or Alarm Test Valve, if acceptable to the authority having jurisdiction). Verify that the system alarms operate. Step. Close the end-of-line Inspector s Test Connection (or Alarm Test Valve). Step. Verify that water ceases to flow from the alarm line drain. If water continues to flow, follow the corrective procedure described in the Care and Maintenance section. Allow sufficient time for drainage of the Retard Chamber and the piping to the water motor alarm. If needed, the plunger on the Automatic Drain Valve can be pressed to accelerate draining of the Retard Chamber. Step. Once it has been verified that the flow of water out of the alarm line drain has stopped, the alarm valve is set and is ready for service. Care and Maintenance The following procedures and inspections should be performed as indicated, in addition to any specific requirements of the authority having jurisdiction. Any impairment must be immediately corrected. Performing the care and maintenance procedures will result in operation of the associated alarms. Consequently, notification must first be given to the owner and fire department, central station, or other signal station to which the alarms are connected. Before closing a fire protection system main control valve for maintenance work on the fire protection systems that it controls, obtain permission to shut down the affected fire protection systems must first be obtained from the proper authorities, and notify all personnel who may be affected by this action. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service. The Model AV--00 Alarm Valves do not require any regularly scheduled maintenance. It is recommended, however, that proper operation of the alarms be periodically verified in accordance with a procedure that is acceptable to the authority having jurisdiction. Any impairment must be immediately corrected. Periodic Waterflow Alarm Test Procedure Testing of the system waterflow alarms should be performed periodically based on the requirements of the authority having jurisdiction. Step. Notify the proper authorities and all personnel who may be affected that an alarm test is to be performed. Step. Open the Alarm Test Valve (or end-of-line Inspector s Test Connection, if acceptable to the authority having jurisdiction) and verify that the system alarms operate in accordance with the requirements of the authority having jurisdiction. Verify that the water motor alarm and/or the pressure alarm switch properly actuate and within the elapsed time required by the authority having jurisdiction. Step. Verify that water is draining from the Automatic Drain Valve. Step. Close the Alarm Test Valve (or end-of-line Inspector s Test Connection). Step. Verify that water ceases to flow from the Automatic Drain Valve after allowing sufficient time for the Retard Chamber and alarm line to the water motor alarm, as applicable, to drain. If desired, the plunger on the Automatic Drain Valve can be pressed to accelerate draining of the Retard Chamber. Step. Clean the Strainer located at the connection to the Retard Chamber, as applicable. Be sure to replace the strainer basket and tighten the cap securely. NOTICE Cleaning of the Strainer after each operation of the alarms is especially important in the case of water supplies (such as lakes and rivers) having a large quantity of suspended matter. A clogged alarm line can prevent operation of the alarms.