Sirius Control Box 6130 LRIT

Similar documents
Owner s Manual. PIR-1 IR Learner

WatchDog Wireless Crop Monitor Operation Manual

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

3820, 3820i, 4820, 4820i

GPS Evaluation Kit EVA1037/1080

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

User manual. KNXgal. version

T4000 Security Communicator

640 Series Advanced Remote Vehicle Security System

Home Doorway Alert Kit

Warranty Registration

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

PBI Manual. Paradox to KNX-BUS Interface

Document No

Mark 25 Ultrapure Water Conductivity Analyzer

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

VESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071

Door Release Power Supply

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

Ontech GSM 9040/50. Reference Manual English -1 -

VX SERIES Wireless Thermostat with Occupancy Sensor

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Installation Guide. Emme Core

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

INSTRUCTION MANUAL P Heating and 1 Cooling

RMS/RPX Reader. User Manual

PERMACONN PM1030 Includes DI300. Installation Manual

M1000 Alarm Annunciator

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

UNC100 Integra Manual

Simplex Panel Interface Guide

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Installation and Operations Manual

MODEL 5100 BROADBAND ALARM COMMUNICATOR INSTALLATION & USER S GUIDE PRODUCT ID #

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

Vehicle Security System

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

20 Light Remote Annunciator

Added password for IP setup page : Password must be in IP format!

USER MANUAL FOR OPERATING SYSTEM

Series: MBC1-TC Mini Benchtop Temperature Controller

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

X64 Wireless Training

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

1. Functions of GPS locator ETLOC-30S 3

RS485 MODBUS Module 8AI

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CO2 Sensor User and Installation Guide

Eclipse Nursecall Systems Ltd. Clipper Plus & Clipper ID. Document V.2.1b (Basic) ENS. Freedom Through Technology

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

2 - Wire Programmable Digital Thermostat

P2267 NETWORK INTERFACE

PIR Sensor. User s Guide

INSTRUCTION MANUAL. Dual Alarm Clock Radio For ipod BCR002IP

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

External Wireless Sounder

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

2-Port alarmcharge Hub - Manual

Digital Refrigerator/Freezer Thermometer model 00986

CD6102 / CD6102 OC / CD6102-2

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

CT2 Retro Box Installation Instruction Manual

MGC Dock User s Manual

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Ethernet to Serial Bridge Owners Manual Circuit Board: AB Converter: Digi Connect ME

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

Protocol Station Remote Alarm

Single Station Remote Alarm

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

21-light Remote Annunciator. Owner s Manual

3121V O WNER S GUIDE & INSTALL GUIDE. The company behind Viper Auto Security Systems is Directed.

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

BURGLAR ALARM PANEL BS-468

CBI-064. User Manual. Caddx to KNX-BUS Interface

Transcription:

Sirius Control Box 6130 LRIT Long-Range Identification and Tracking Owner s & Installation Manual Version 1.12

- 2 - Sirius Control Box 6130 LRIT

Disclaimer Sirius is a brand name owned by Polaris Electronics A/S, Denmark. We reserve the right to change specifications and instructions given in this manual without notices. No liability can be accepted for any inaccuracies or omissions in the manual, although every care has been taken to make it as complete and accurate as possible. This manual applies to firmware release of September 2013. Polaris Electronics A/S Kaerholt 1 DK-9210 Aalborg SO Denmark Telephone: +45 9631 7900 Fax: +45 9631 7901 E-mail: info@polaris-as.dk Web: www.polaris-as.dk - 3 -

Table of Contents Page Owner s Manual... - 5 - Safety Notices... - 5 - LRIT (Long Range Identification & Tracking)... - 6 - About the Sirius Control Box 6130 LRIT... - 7 - Indicators & Buttons... - 8 - Operation... - 9 - Installation Manual... - 10 - Function of LRIT... - 11 - LRIT Conformance Test... - 11 - Installation Overview... - 12 - Connectors & Switches... - 13 - Compass Safe Distance... - 14 - Power & Antenna Connection... - 14 - Alarm Output... - 15 - Configuration... - 16 - Setup... - 18 - First time boot up... - 19 - Trouble Shooting Guide... - 20 - Firmware Update... - 21 - Warranty and Service... - 22 - Validity... - 23 - End of Life Statement... - 23 - - 4 -

Owner s Manual Congratulations with your new Sirius Control Box 6130 LRIT. Safety Notices Before installation please read the Installation Manual carefully. The equipment must be 10-32 V DC powered only. Do not attempt to modify the Sirius Control Box 6130 LRIT. Doing so will invalidate the warranty. The equipment is designed for operation with SAILOR 6130 LRIT in temperatures between -15 o C and +55 o C. Do not use the Sirius Control Box 6130 LRIT in temperatures which exceed this range. - 5 -

LRIT (Long Range Identification & Tracking) Ships subjected to LRIT regulation must report position to Flag Administration at least 4 times a day. The SAILOR 6130 LRIT System complies with the LRIT regulation and automatically reports the position of the ship every 6 th hour. When used with a Sirius Control Box 6130 LRIT, you can read out the status of the system by six LEDs, reset (reboot) the system via the Reset switch and have a buzzer/relay alarm function. Via the Sirius Control Box 6130 LRIT a service technician can be connected to the SAILOR 6130 LRIT using either the USB interface or the RS-232 interface. - 6 -

About the Sirius Control Box 6130 LRIT There is no on/off switch, as the equipment must always be turned on due to the LRIT regulation. If the equipment is installed with an external switch at the main electrical switchboard, please, be sure that the equipment is always turned on. Models There are two different models of the cover: Wall mounted (standard) Flush mounted (option) - 7 -

Indicators & Buttons - 8 -

Operation Front buttons description Button name RESET MUTE / DIM Function Removes power from antenna and the Sirius Control Box 6130 LRIT Mutes alarm / Dims LEDs by holding the button* * LED dimming functionality available from PCB version D. LED description Name Color On Flashing Off Dimmable PWR In Red Power OK - No Power Yes GPS Green GPS Signal OK - No GPS Signal Yes SAT Lock Green SAT Lock OK - No SAT Lock Yes Prg. Info Yellow LRIT prg. running LRIT prg. stopped No LRIT prg. Yes Ant Con. Yellow Ant. Connection OK - No Ant. conn. Yes Alarm Red Audible Alarm Silent alarm No Alarm Yes Alarm description Buzzer interval Alarm LED Program LED Ant. Conn. LED Error 0.25 sec on/0.25 sec off On Off Off No antenna connection at startup 0.5 sec on/2 sec off On On On LRIT report not sent on time 0.5 sec on/2 sec off On Off On No LRIT program in current ocean On #1 On Flashing On LRIT prg. available, but not running On #2 On Off Off Lost connection to antenna On #3 On Off On No program - 9 -

Installation Manual The Sirius Control Box 6130 LRIT package includes: Sirius Control Box 6130 LRIT User & Installation Manual The SAILOR 6130 LRIT package includes: SAILOR 3027LT Terminal (Antenna) Pole mount 30m NMEA2K Mini cable w/plug for mini-c 6m NMEA2K Power cable Mini/Micro NMEA2K Tee User & Installation Manual Refer to the SAILOR 6120/30/40/50 Installation Manual for installation of the SAILOR 3027LT Terminal. - 10

Function of LRIT The position of the vessel is automatically reported to the Flag Administration via a DNID and controlled by a program in the terminal (antenna). DNID (Data reporting Network IDentification) is the ID of the vessel in the LRIT system. Therefore it needs to be downloaded before the program (reporting) can be started. The program is a configuration in the terminal (antenna) which can be setup to report on a DNID by a specific interval. In LRIT systems this interval is normally every 6 th hour. The LRIT control centre under the Flag Administration controls both the DNID and program. Therefore you will need to contact the Flag Administration if you have issues with the DNID or program of your LRIT system. Please note that you can also have other tracking providers that use DNIDs and programs on your LRIT system. LRIT Conformance Test To test above, a new LRIT system needs to pass a LRIT conformance test. After the conformance test, flag state will download DNIDs. For LRIT Conformance Test please contact Polaris Electronics A/S. A hard copy of the LRIT Conformance Test Report must be kept on board. - 11

Installation Overview 30m NMEA2K Mini cable Recommended 24 VDC Mini/Micro NMEA2K Tee 6m NMEA2K Power cable Not included (Min. 1.5 mm 2 ) - 12

Connectors & Switches CANBUS/Power/ Alarm output (J3) Reset Switch (S2) DIP Switches (S3) MUTE Switch (S1) Jumper for FW update of 3027 CANBUS for SAILOR 3027 LRIT Terminal (J2) UART RS-232 interface Power input 10-32 VDC (J3) USB interface - 13

Compass Safe Distance Distance to compass must be at least 70 cm. Do not install the Sirius Control Box 6130 LRIT closer to magnetic compasses. Power & Antenna Connection Connect the Sirius Control Box 6130 LRIT to 12 or 24 V DC (10-32 V DC). Recommended is 24 V DC. It is recommended to include a fuse in the power supply. Wiring of cable terminals NMEA2K cable (J2) Power cable (J1) CAN-H White wire 12-24VDC + Positive wire CAN-L Blue wire 12-24VDC - Negative wire PWR + PWR - Red wire Black wire - 14

Alarm Output It is an option to have the Alarm output routed to ships alarm system through a build in relay. The output is available on the CANBUS/Power/Alarm output. CANBUS/Power/Alarm output (J3) PIN 1 CAN-H 2 CAN-L 3 PWR + 4 PWR - 5 Relay Output 6 Relay Output Output PIN 6 PIN 5-15

Configuration To be able to have the program read out on LEDs, you need to do below configuration on the SAILOR 6130 LRIT. Polaris Electronics A/S does this configuration on all SAILOR 6130 LRIT systems sold together with a Sirius Control Box 6130 LRIT. If the SAILOR 6130 LRIT is not configured, you will need to do the configuration. HyperTerminal settings for UART RS-232 and USB port. Setting Value Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None Make a HyperTerminal connection to the Sirius Connection Box 6130 LRIT. When connection is running, it will answer a [Enter] command with: : Write following in a Notepad: LRIT_DEBUG [Enter] - 16

Copy and paste the two lines (including return command) to the HyperTerminal with connection to the Sirius Connection Box 6130 LRIT: Login as SYSADM: su sysadm [Enter] password: (password) [Enter] If the password has not been set before, it is default sysadm. If the password is unknown, please contact Polaris Electronics. DNID configuration (does not apply changes for already downloaded DNIDs): dn -f 0,1,0,0,0,0,0,0,0,3,0 [Enter] Reset system after the configuration. - 17

Setup From the DIP Switch you can do below setup. If the SAILOR 6130 LRIT is running more tracking programs than LRIT, select the LRIT DNID program for monitoring (first DNID downloaded will always be program 0). DIP Switch (S3) settings Pin Settings Function ON OFF 1 ON 120 ohm termination CAN bus Enabled Disabled 2 OFF Communication port selection UART RS-232 USB port 3 OFF Alarm buzzer Disabled Enabled 4-5 OFF/OFF Monitor DNID program 0 - - 4-5 ON/OFF Monitor DNID program 1 - - 4-5 OFF/ON Monitor DNID program 2 - - 4-5 ON/ON Monitor DNID program 3 - - 6 ON Operation selection Normal operation Debug/programming Settings in bold are default values. - 18

First time boot up When the system is booted up after installation, no DNID and program will be available, until the LRIT conformance test is started. Because of above, the alarm will be activated every 3 rd hour until a DNID is downloaded. To prevent above, press the MUTE button for more than 10 seconds during start up until beep sounds. This will deactivate the alarm until the first DNID is downloaded and program is started. After this, all will be running as normally. Above might also be seen between end of LRIT conformance test and download of DNID by flag administration. - 19

Trouble Shooting Guide See below Errors in the alarm list Alarm Error Posible Causes Posible Solution No antenna connection at startup LRIT report not sent on time No LRIT program in current ocean LRIT prg. Available, but not running Lost connection to antenna No program No SAT LOCK No GPS signal Incorrectly installation Cable defective Check installation. Connections and cables. Replace cable 3027 defective Replace 3027 antenna No SAT LOCK or GPS signal No DNID or program in current ocean LRIT program has not been started Loose connection in connectors Cable defective Check SAT LOCK and GPS LED Ask flag administration to download DNID/program in current ocean Ask flag administration to start program Check connections and plugs. Replace cable 3027 defective Replace 3027 antenna No DNID or program Signal blockage by obstruction Signal blockage by interference from other system Ask flag administration to download and start DNID/program Relocate 3027 antenna Relocate 3027 antenna or interfering system 3027 defective Replace 3027 antenna Signal blockage by interference from other system Relocate 3027 antenna or interfering system 3027 defective Replace 3027 antenna - 20

Firmware Update The firmware of the Sirius Control Box 6130 LRIT can only be updated by Polaris Electronics A/S. The firmware of the SAILOR 6130 LRIT can be updated by setting the jumper in the Sirius Connection Box 6130 and connecting a SAILOR 6194 Terminal Control Unit to the Mini/Micro NMEA2K Tee. Sirius Connection Box 6130 LRIT Power Supply (not included) Please note that the Sirius Connection Box 6130 LRIT will activate the alarm when the jumper is set, ignore/disable these alarms. Remove jumper again after firmware update. - 21

Warranty and Service The Sirius Control Box 6130 LRIT has a 24 months warranty from the date of purchase. Warranty Service is available worldwide through authorized service dealers. Products returned will, at the sole discretion of Polaris Electronics A/S, either be repaired or replaced free of charge within normal working hours. Freight charges, insurance, duties or any other costs are the responsibility of the customer. Maximum liability shall not, in any case, exceed the contract price of the products claimed to be defective. On-Board Service can be arranged by Polaris Electronics A/S or local service dealers upon request. Expenses associated with replacement of the defective modules/parts, on-board time, overtime, travel, lodging, per diem, insurance, duties or any other costs are the responsibility of the customer. Additional expenses associated with replacement of antenna cable, dry docking and precautionary measures are not covered by this warranty. - 22

Validity: This warranty is effective only when proof of purchase and an equipment serial number are presented. Furthermore, the installation and operation have to be carried out in accordance with the product manual. Warranty liability does not apply to any equipment which has become inoperative due to misuse, accident, neglect, sea water damage or unauthorized repair. Polaris Electronics will not be liable for any loss, incidental or consequential damages whether based upon warranty, contract or negligence, or arising in connection with the sale, installation, use or repair of the product. Consequential damages include, but are not limited to, any loss of profit, property damage or personal injury. The terms of warranty as described does not affect your statutory rights. All enquiries relating to this warranty or approved service agents should be sent to: Polaris Electronics A/S Telephone: +45 9631 7900 Kaerholt 1 Fax: +45 9631 7901 DK-9210 Aalborg SO E-mail: info@polaris-as.dk Denmark Web: www.polaris-as.dk End of Life Statement The European Waste Electrical and Electronic Equipment Directive aims to minimize the environmental impact from electrical and electronic devises when they reach end of life. We strongly urge you to treat the equipment in accordance with local legislation when it becomes waste after end of life. - 23

- 24 Sirius Control Box 6130 LRIT