Intrinsically Safe Solutions

Similar documents
STROBE / SOUNDER INTERFACE

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

IECEx Certificate of Conformity

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

4) Intrinsic Safety Certification

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper. Calibration in hazardous areas

UL HAZARDOUS LOCATIONS SERVICES

DB5 Intrinsically Safe Sounder Type DB-5

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Inductive slot sensor

Guide for hazardous areas

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Intrinsically Safe Flame Detector Installation Guide

Hazardous Area Classifications and Protections

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Overview of Hazardous Locations as They Relate to Solenoid Valves

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ATEX, NOMENCLATURE AND CODING

INSTRUCTION & SERVICE MANUAL

E2S Datasheet v10a

Electrical Installations Design, Selection, Erection and Inspection

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

EU DECLARATION OF CONFORMITY

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Fixed Gas Detection System/Meridian CERTIFICATION

INSTRUCTION MANUAL (ATEX / IECEx)

SET Installation and Operating Instructions. Level switch for one sensor

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

MICROpeL 75 Combustible Gas Sensor Part Number: PM

ATEX, NOMENCLATURE AND CODING

DICTATOR Hold-Open Systems for Hazardous Areas

Guide to Hazardous Location Approvals:

14300 MAINS SEPARATOR ALARM MANUAL

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Universal Tank Alarm Type Installation, Operation & Maintenance

INSTRUCTION MANUAL (ATEX)

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Solar Separator Alarm Type Installation, Operation & Maintenance

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

SOLAR SEPARATOR ALARM

Fire Alarm System Accessories

Technical Data. Dimensions

Certificate of Compliance

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

OilSET-1000 (12 VDC)

standards: standards:

S T R I T T & P R I E B E I N C.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

OPTIWAVE X500 Supplementary Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

XP95 Intrinsically Safe Product Guide MAN 3054

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Fire Alarm System Accessories

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

SET-2000 Hi Level/Oil

Safety instructions VEGAPULS 64

Tank Gauging System Special Safety Instruction

Guide to Intrinsically Safe Portable Radios

Technical Data. Dimensions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

PEPPERL+FUCHS GmbH

Dual certification! Air handling units for potentially explosive atmospheres

Certificate of Compliance

RT FLOW RATE TOTALISER

Intrinsic Safety Solenoid Valves :-

NCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Integrated Solutions Low Voltage Systems

IECEx Certificate of Conformity

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

OPTIBAR P 1010/2010 C Supplementary instructions

ATEX Explained A brief Introduction

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC

Certification Supplement Manual

TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

The SCS-8A Smoke Control Module & SCE-8A Smoke Control Expander are used to control and monitor fans connected to an addressable fire panel.

Orbis IS Product Guide MAN 3041

Hazardous Area Zirconia Oxygen Systems

SET-2000 Oil/Sludge 12 VDC

User s Manual YTA610 and YTA710 NEPSI Certification

Transcription:

Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029

Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions about our printed manuals you can email us. Please include the following information: Product name and version number (if applicable) Manual part number and revision (found on the front cover) Page number Brief description of the content you think should be improved or corrected Your suggestion for how to correct/improve documentation Send email messages to: techpubs@notifier.com.au Please note this email address is for documentation feedback only. If you have any technical issues, please contact you nearest branch for technical support.

Table of Contents Section 1 About this Manual... 2 1.1. Notes, Cautions and Warnings... 2 1.2. Related Documentation... 2 Section 2 Intrinsically Safe Solutions Overview... 3 2.1. Introduction... 3 2.2. Intrinsically Safe Area Classification... 3 2.3. Intrinsically Safe Solution System Diagram... 5 Section 3 List of Recommended Devices... 6 3.1. Intrinsic Safety Barrier... 6 3.2. Intrinsic Safety Barrier Enclosure... 6 3.3. Intrinsically Safe Devices... 6 Section 4 Installation Information... 7 4.1. Intrinsically Safe Solution for IS conventional devices... 7 4.1.1 Wiring schematic for IS conventional devices...8 4.2. Intrinsically Safe Solution for IS addressable devices... 9 4.3. Intrinsically Safe Solution for IS sounders and beacons... 10 DOC-01-029 1

Section 1 About this Manual Section 1 About this Manual 1.1. Notes, Cautions and Warnings This manual contains notes, cautions and warnings to alert the reader as follows: NOTE: Supplement information for a topic such as tips and references. CAUTION: Information about procedures that could cause programming errors, runtime errors, or equipment damage. WARNING: Indicates information about procedures that could cause irreversible equipment damage, irreversible loss of programming data or personal injury. 1.2. Related Documentation Related documentation: Title CFP-16 Operation, Installation & Programming manual AFP-2800-2802 Operation, Installation & Programming manual MTL 5500 Series Instruction manual MTL 7700 Series Instruction manual Y72221 Intrinsically Safety Barrier for Addressable Detection technical datasheet DX Enclosures for MTL5000/7000 Series System Sensor 1151EIS Installation and Maintenance Instructions System Sensor 5451EIS Product Specification Document Number DOC-01-022 DOC-01-010 INM5500 INM7700 IDX-751-IMX-1- y72221-768-415 INM57ENC D100-59-00 D400-50-00 IS-A105N Instruction manual IS 4501 IS-L101L Instruction manual IS 4601 IS-mA1 Instruction manual IS 5001 IS-mB1 Instruction manual IS 5002 IS-mC1 Instruction manual IS 5003 WCP3-1 Technical datasheet KAC_IS-WCP3-1 DOC-01-029 2

Section 2 Intrinsically Safe Solutions Overview Section 2 Intrinsically Safe Solutions Overview 2.1. Introduction This document outlines the intrinsically safe solutions which include a list of recommended intrinsic safety barriers and intrinsically safe devices that are compatible with the range of Notifier products with the installation information. Intrinsically safety (IS) is a low-energy signalling technique applied to electrical equipment and wiring in hazardous areas for safe operation by limiting the energy available for ignition. A hazardous area may contain flammable gasses, vapours or combustible dusts which can cause a fire or explosion when a source of ignition is present. The intrinsically safe solutions require the installation of an intrinsic safety barrier with compatible intrinsically safe devices and in accordance with the manufacturer s installation requirements. NOTE: The intrinsically safe solution must be installed and tested by a qualified technical person in accordance with all appropriate standards which may include reference to AS60079.17 and in accordance with the instructions contained here. 2.2. Intrinsically Safe Area Classification The intrinsically safe area classification in accordance with AS60079.0 is defined as below. The explosion protection symbol Ex indicates that the electrical equipment corresponds to one or more of the types of protection. Types of Protection The types of protection for intrinsic safety i is subdivided into levels of protection ia, ib and ic ; which correlate with equipment protection levels Ma and Mb (for installation in a mine susceptible to firedamp), Ga, Gb and Gc (for explosive gas atmospheres) and Da, Db and Dc (for explosive dust atmospheres). Refer to AS60079.0 for the equipment protection levels definitions. DOC-01-029 3

Section 2 Intrinsically Safe Solutions Overview Apparatus Group The apparatus group is subdivided into group I (for electrical equipment intended for use in mines susceptible to firedamp) with II (for electrical equipment intended for use in explosive gas atmospheres other than mines susceptible to firedamp) and III (for electrical equipment intended for use in explosive dust atmospheres other than mines susceptible to firedamp). Apparatus Group Typical Gas Ignitability Group IIC Group IIB Acetylene Hydrogen Ethylene Group IIA Propane Apparatus Group Group IIIC Group IIIB Group IIIA Type of Dust Conductive dust Non-conductive dust Combustible flyings Equipment marked IIC is suitable for applications requiring Group IIB equipment. Similarly, equipment marked IIB is suitable for applications requiring Group IIA equipment. This is applicable for both Apparatus groups II and III. Temperature Class The temperature class is determined by the highest surface temperature which can be measured from the equipment at the rated voltage and ambient temperature range. Temperature Class Maximum Surface Temperature ( C) T1 450 T2 300 T3 200 T4 135 T5 100 T6 85 DOC-01-029 4

Section 2 Intrinsically Safe Solutions Overview Zone Definition The zone definition is based upon the frequency of the occurrence and duration of the explosive gas or combustible dust atmospheres. Continuous Hazard Intermittent Hazard Possible Hazard Explosive gas Zone 0 Zone 1 Zone 2 Combustible dust Zone 20 Zone 21 Zone 22 Hazard is present continuously or for long period or frequently Hazard is likely to occur in normal operation occasionally Hazard is not likely to occur in normal operation but if occur, exists for a short period only 2.3. Intrinsically Safe Solution System Diagram Fire protection applications often require signals to be sent between the fire panel and the fire protection devices such as detectors, sounders or strobes. For an intrinsically safe solution system, the fire alarm control panel and the intrinsic safety barrier are usually installed in the safe area while the intrinsically safe fire protection devices are installed in the hazardous area. The general intrinsically safe solution system diagram is shown below. SAFE AREA HAZARDOUS AREA Fire Alarm Control Panel (FACP) Intrinsic Safety Barrier Intrinsically Safe Apparatus NOTE: The assumption of adding an intrinsic safety barrier to a circuit will result in an intrinsically safe solution is incorrect. The intrinsic safety barrier must be suitable with the type of intrinsically safe devices being installed. NOTE: Always refer to the manufacturer s installation manual for installing the intrinsic safety barrier and intrinsically safe devices. This document is not intended to be used for installation but as a guideline only. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. DOC-01-029 5

Section 3 List of Recommended Devices Section 3 List of Recommended Devices 3.1. Intrinsic Safety Barrier Model Device Description Intrinsic Safety Rating MTL5561 2-channel galvanic isolator [Ex ia] IIC (-20 C Ta +60 C) [Ex iad] [Ex ia] I MTL7728+ 1-channel zener barrier [EEx ia] IIC (-20 C Ta +60 C) Y72221-L4 1-channel galvanic isolator [Ex ia Ga] IIC (-20 C Ta +60 C) [Ex ia Ma] I [Ex ia Da] IIIC 3.2. Intrinsic Safety Barrier Enclosure Model Device Description Ingress Protection Rating DX070 DX enclosure for intrinsic safety barriers IP65 3.3. Intrinsically Safe Devices Model Device Description Intrinsic Safety Rating 1151EISE 5451EISE IDX-751 Intrinsically safe conventional ionization smoke detector Intrinsically safe conventional thermal rate-of-rise detector Intrinsically safe addressable photoelectric detector [Ex ia] IIB T5 (-20 C Ta +40 C) [Ex ia] IIB T5 (-20 C Ta +40 C) [Ex ia] IIC T5 Ga (-20 C Ta +40 C) [Ex ia] IIC T4 Ga (-20 C Ta +60 C) IS-A105N Intrinsically safe horn sounder [Ex ia] IIC T4 Ga (-40 C Ta +60 C) IS-L101L Intrinsically safe LED beacon [Ex ia] IIC T4 Ga (-40 C Ta +60 C) IS-mA1 Intrinsically safe minialarm sounder [Ex ia] IIC T4 Ga (-40 C Ta +60 C) IS-mB1 Intrinsically safe minialite beacon [Ex ia] IIC T4 Ga (-40 C Ta +60 C) IS-mC1 WCP3A-IS Intrinsically safe minialert combined sounder/ beacon Intrinsically safe conventional outdoor manual call point [Ex ia] IIC T4 Ga (-40 C Ta +60 C) [Ex ia] IIB T4 Ga (-20 C Ta +70 C) [Ex iad] T4 Da (-20 C Ta +40 C when Pi = 0.75W) and (-20 C Ta +40 C when Pi = 0.65W) DOC-01-029 6

Section 4 Installation Information Section 4 Installation Information 4.1. Intrinsically Safe Solution for IS conventional devices The intrinsically safe solution for the intrinsically safe conventional devices can be installed to meet EEx ia IIB T5 (without WCP3A-IS) or EEx ia IIB T4 (with WCP3A-IS). The intrinsically safe conventional devices such as the 1151 EISE, 5451 EISE and WCP3A-IS shall be installed with the intrinsic safety barrier MTL5561 to the conventional zone on the CFP-16 fire panel or to the FZM-1/ XP6-MA monitoring input on the Notifier addressable fire panel. The conventional zone shall be terminated using the End-Of-Line resistor with a resistance value of 3k9Ω. Refer to Clause 5.3.3 of AS60079.0-2012 for the surface area and the acceptable surface temperature exceeding the temperature classification. The intrinsic safety barrier shall be housed in the intrinsic safety barrier enclosure DX070 for protection against excessive mechanical and thermal stresses, dust, moisture and other contaminants and be installed in the safe area only. The maximum number of intrinsically safe addressable devices that can be installed on a circuit shall not exceed 2.02 ma. IS Detector Quiescent Current Quantity x [current draw] = Total (ma) 1151EISE [ ] x [ I DETECTOR * ] 5451EISE [ ] x [ I DETECTOR * ] WCP3A-IS [ ] x [ I MCP * ] Total Quiescent Current shall be less than 2.02 ma The capacitance and either the inductance or inductance to resistance ratio (L/R) of the hazardous area load connected to either channel of the intrinsic safety barrier must not exceed the following values : Group Capacitance ( µf) Inductance (mh) Or L/R Ratio ( µh/ω) IIB 0.65 12.6 210 IIA 2.15 33.6 444 NOTE: The IS conventional devices 1151EISE and 5451EISE are rated as temperature class T5 (100 C) while the WCP3A-IS is rated as T4 (135 C). A combination of these devices will lower the intrinsically safe system temperature class from T5 to T4. The interconnecting wiring between the intrinsic safety barrier and the intrinsically safe devices shall be installed in accordance with the cables requirements in AS60079.25. * Refer to the product specifications to find the quiescent current draw for each intrinsically safe device. Baseefa (2012), IECEx BAS 09.008 issue number 2 MTL 5561 two channel fire/ smoke detector interface. DOC-01-029 7

Section 4 Installation Information 4.1.1 Wiring schematic for IS conventional devices DOC-01-029 8

Section 4 Installation Information 4.2. Intrinsically Safe Solution for IS addressable devices The intrinsically safe solution for the intrinsically safe addressable devices can be installed to meet EEx ia IIC T5. The intrinsically safe addressable device such as the IDX-751 shall be installed with the intrinsic safety barrier Y72221-L4 and connected to the Notifier addressable fire panel using the translator module IMX-1. The intrinsic safety barrier shall be housed in the intrinsic safety barrier enclosure DX070 for protection against excessive mechanical and thermal stresses, dust, moisture and other contaminants and be installed in the safe area only. The maximum number of IDX-751 detectors that can be installed to the intrinsic safety barrier is 15 detectors. The capacitance and either the inductance or inductance to resistance ratio (L/R) of the hazardous area load connected to the intrinsic safety barrier must not exceed the following values : Group Capacitance ( µf) Inductance (mh) IIC 0.083 4.2 55 Or L/R Ratio ( µh/ω) IIB 0.65 12.6 165 IIA 2.15 33.6 440 The interconnecting wiring between the intrinsic safety barrier and the intrinsically safe devices shall be installed in accordance with the cables requirements in AS60079.25. Notifier, Installation and maintenance instructions for model IDX-751 (I56-3383-004) DOC-01-029 9

Section 4 Installation Information Intrinsically Safe Solution for IS sounders and beacons The intrinsically safe solution for the intrinsically safe sounders and beacons can be installed to meet EEx ia IIC T4. The intrinsically safe beacons and sounders such as IS-A105N, IS-L101L, IS-mA1, IS-mB1 and ISmC1 shall be installed with the intrinsic safety barrier MTL7728+ and connected to an isolated power supply. The intrinsically safe devices are controlled using the relay output on the CFP-16 fire panel or the FRM-1 relay control module on the Notifier addressable fire panel. NOTE: The output devices are unmonitored and an isolated power supply is required. Refer to the manufacturer s installation manual to determine the maximum number of devices that can be installed to the safety barrier circuit. The intrinsic safety barrier shall be housed in the intrinsic safety barrier enclosure DX070 for protection against excessive mechanical and thermal stresses, dust, moisture and other contaminants and be installed in the safe area only. The capacitance and either the inductance or inductance to resistance ratio (L/R) of the hazardous area load connected to the intrinsic safety barrier must not exceed the following values : Group Capacitance ( µf) Inductance (mh) Or L/R Ratio ( µh/ω) IIC 0.083 3.05 (4.2 ** ) 56 The interconnecting wiring between the intrinsic safety barrier and the intrinsically safe devices shall be installed in accordance with the cables requirements in AS60079.25. MTL, Technical Datasheet MTL7700 Series (EPS770 Rev 6 140410) ** The cable inductance may be increased to the values within parentheses when the external circuit contains no lumped inductance greater than 10 µh. DOC-01-029 10

11

12

13

New South Wales (Head Office) 9 Columbia Way Baulkham Hills NSW 2153 ph +61 (0)2 9899-4155 fax +61 (0)2 9899-4156 New Zealand 264 Mt Eden Road Mt Eden 1024 ph +64 (0)9 623 5050 fax +64 (0)9 623 5060