OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Similar documents
3M Oldham OLCT 100. Description. Fixed Gas Detector

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

GAS DETECTOR ST400EC PART.NO

Transmitters/Sensors. OLCT Series

Detection, Protection, Innovation

Sieger Apex. Flexibility that meets your requirements

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Global Gas Detection and Monitoring Solutions

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

3M Oldham MX 43 Controller

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Monitores Personales. Personal Monitor

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ESD500. ESD500 Combustible / Toxic Gas Detector

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

SIL 2. Ultima X Series Gas Monitors CERTIFIED

ESD3000 ESD200 Combustible / Toxic Gas Detector

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

SP-220. Features. Combustible handheld gas leakage detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

ALTAIR 5X Multigas Detector Product Specification

Model D12. Digital Gas Transmitter

P R O D U C T D ATA S H E E T

User manual CTX 300 Analogic Gas Detector

Dräger Polytron 8000 Stationary gas detector (EC)

ULTIMA X5000. MSAX5000.com

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

S5000 Gas Monitor. GMS5000.com

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

User manual CTX 300. Analogic Gas Detector. The Fixed Gas Detection Experts. Part Number: NP300GB Revision: K.1

Dräger Polytron 8200 Stationary gas detector (CatEx)

incontrol Systems Inc. Flame and Gas Detection

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : G.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

MERIDIAN UNIVERSAL GAS DETECTOR

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger PEX 3000 Flammable Gas Detection

MICRO III (G202 / G202s / G212) Single Gas Detector

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Dräger X-am 5000 Multi-Gas Detection

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : E

Micro III (Models G203, G203S, and G213) Operation Manual

G-TECTA TM. Portable Gas Detection Instruments

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Zareba Sensepoint Pro

ALTAIR 5X Multigas Detector

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger X-am 7000 Multi-Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger Polytron 5720 IR Detection of carbon dioxide

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

An easy and flexible way to do gas detection.

Fixed Gas & Flame Detection International Product Range Overview

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

VENTIS PRO SERIES. Product Guide

APPLICATION DATA SHEET

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Dräger X-am 2500 Multi-Gas Detection

Dräger Flame 2100 Flame Detection

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Transcription:

DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better protection.

OLCT Applications The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Steel mills Our products are always application-driven, solution-oriented. Options include: Petrochemical facilities Chemical industry Pharmaceutical industry Food industry Refrigeration industry Water treatment OLCT transmitter with 4-20 ma output OLC detector with a Wheatstone bridge output for detection of combustible gases Available in explosion-proof or intrinsically safe versions, the OLCT is suitable for detection of all gases in ATEX zones. The OLCT is available in a stainless steel version, offering increased resistance to corrosive elements (ideal for marine, wastewater treatment plants, food processing activities, etc). This stainless steel intrinsically safe version is certified for use in zones 0 (gas) and 20 (dust), whereas all other versions of the OLCT are certified for use in zones 1 (gas) and 21 (dust). IR Sensor The infrared sensor provides detection of CO2 and is warranty 3 years.

OLCT OLCT XP Explosion-proof version is equipped with a catalytic, electrochemical or semiconductor sensor, for detection of combustible, toxic gases or oxygen. CO 2 OLCT XP IR OLCT IS Intrinsically safe version is equipped with an electrochemical sensor for detection of toxic gases or oxygen. OLCT XP IR GAS HAZARD Combustible Toxic or O 2 OLC OLCT XP HT OLCT XP OLCT XP OLCT IS Explosion-proof IR version is equipped with an infrared sensor for detection of CO 2. OLCT XP HT High temperature explosion-proof version for detection of combustible gases up to 200 C. High temperature cable included: 5, 10, 15 meter lengths. RELIABILITY The OLCT is SIL 2 certified by INERIS, according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors. Gas Measure SIL Capability λ DU PFD avg Test Period Combustibles (a) Catalytic (C0) SIL 2 0,189.10-6 8.3 10-4 12 months O (b)(c) 2 Electrochemical SIL 2 0.74 10-6 1.62 10-3 6 months CO (b) Electrochemical SIL 2 1.09 10-6 1.19 10-3 3 months H 2 S (b) Electrochemical SIL 2 2.98 10-6 3.26 10-3 3 months (b) NH 3 Electrochemical SIL 2 4.48 10-6 4.91 10-3 3 months (a) complete unit, according to certificate INERIS No. 93664/2012 (b) software and hardware according to certificate INERIS No. 93664/2012, sensors data according to proven in use (c) O2 sensor with 28 months life expectancy

OLCT 80 Gas Measuring Range (ppm) XP Version IS Version Temperature Range ( C) % RH Accuracy (ppm) Average Life Expectancy (month) Response Time T 50 /T 90 (s) Storage Condition Explosive Gases Catalytic 0-% LEL -40 to +70 0-95 Catalytic High Temperature 0-% LEL -20 to +200 0-95 +/- 1% LEL (from 0 to 70% LEL) +/- 1% LEL (from 0 to 70% LEL) 40 6/15 (CH 4 ) (b) 40 6/15 (CH 4 ) (b) AsH 3 Arsine 1.00-20 to +40 20-90 +/- 0.05 18 30/120 (a) CH 2 O Formaldehyde 50.0-20 to +50 15-90 +/- 1.0 36 50/240 (a) Cl 2 Chlorine 10.0-20 to +40 10-90 +/- 0.4 24 10/60 (a) ClO 2 Chlorine dioxide 3.00-20 to +40 10-90 +/- 0.3 24 20/120 (a) CO CO 2 Carbon monoxide Carbon dioxide 300 0 0-5000ppm 0-5% vol. 0-10% vol. 0-% vol. -20 to +50 15-90 +/- 3 (range 0-) 40 15/40 (a) -20 to +40 10-90 +/- 3% 48 20/120 (a) COCl 2 Phosgene 1.00-20 to +40 15-90 +/- 0.05 12 60/180 (c) ETO Ethylene oxide -20 to +50 15-90 +/- 1.0 36 50/240 (a) H 2 Hydrogen 2000-20 to +50 15-90 +/- 5% 24 30/50 (a) H 2 S Hydrochloric chlo- HCl ride HCN NH 3 NO NO 2 O 2 Hydrogen sulfide Hydrogen cyanide Ammonia Nitrogen monoxide Nitrogen dioxide Oxygen 0 10.0-40 to +50 15-90 +/- 1.5 (range 0-30) 36 15/30 (a) -20 to +40 15-95 +/- 0.4 (range 0-10) 24 30/150 (a) -40 to +40 15-95 +/- 0.3 (range 0-10) 18 30/120 (c) -40 to +40 +/- 5 70/210 0 5000 300 0 10.0-20 to +40 15-90 0-30% vol -20 to +50 15-90 +/- 5 +/- 20 +/- 150 or 10% 24 25/70 20/60 60/180-20 to +50 15-90 +/- 2 (range 0-) 36 10/30 (a) -20 to +50 15-90 +/- 0.8 24 30/60 (a) 0.4% Vol (from 15 to 22% O 2 ) 28 6-15 0-30% vol -40 to +50 10-90 +/-1,5% 60 15/25 PH 3 Phosphine 1.00-20 to +40 20-90 +/- 0.05 18 30/120 (a) SiH 4 Silane 50.0-20 to +40 20-95 +/- 1.0 18 25/120 (a) SO 2 Sulphur dioxide 10.0-20 to +50 15-90 +/- 0.7 (range 0-10) 36 15/45 (a) CH 3 Cl Methyl chloride 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) CH 2 Cl 2 Methylene chloride 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R12 1% vol -20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R22 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R123 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) FX56 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R134 a 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R11 1% vol -20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R23 1% vol -20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R143a 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R404 a 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R507 2000-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R410a 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R32 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R407c 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Freon R408a 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Ethanol 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Toluene 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Isopropanol 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) 2-butanone (MEK) 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) Xylene 500-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) HFO-1234yf 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) HFO-1234ze 0-20 to +55 20-95 +/- 15% (from 20 to 70% FS) 40 25/50 (d) (a) (a) (a) +4 C à +20 C / 20 % à 60% HR (b) -50 C à +70 C / 20 % à 60 % HR (c) +4 C à +20 C / 20 % à 60 % HR (d) -20 C à +50 C / 20 % à 60 % HR 1 bar ± 10 % / 6 mois maximum 1 bar ± 10 % / 6 mois maximum 1 bar ± 10 % / 3 mois maximum 1 bar ± 10 % / 6 mois maximum

OLCT Model OLC OLCT XP OLCT XP IR OLCT XP OLCT XP HT OLCT XP OLCT IS Sensor Catalytic bead Catalytic bead Infrared Electrochemical Catalytic bead Semi-conductor Electrochemical Material Dimensions (mm) (inches) 135 x 133 x 84 135 x 133 x 84 5.43 x 5.24 x 3.31" 5.43 x 5.24 x 3.31" Epoxy-coated aluminium housing (Inox 316L optional). 316 stainless steel sensors 179 x 138 x 84 7.05 x 5.43 x 3.31" 179 x 138 x 84 150 x 138 x 84 7.05 x 5.43 x 3.31" 5.91 x 5.43 x 3.31" 179 x 138 x 84 7.05 x 5.43 x 3.31" 179 x 138 x 84 7.05 x 5.43 x 3.31" Weight (kg) 0.95 1 1.1 1.1 1.8 1.1 1.1 Ingress Protection Cable Entry Supply Voltage Average Consumption only by OLDHAM Controller IP66 M20 or ¾ NPT 15.5 to 32 VDC 13.5 to 32 VDC 10 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC 15.5 to 32 VDC 340 ma 110 ma 60 ma 23.5 ma ma ma 23.5 ma Pressure atmospheric ± 10% Output signal Approvals Cable Usual source encoded from 0 to 23 ma (not isolated) - linear 4 to 20 ma output, reserved for measurement - 0 ma : electronic fault or no power supply - < 1 ma: fault - 2 ma: initialization mode - > 23 ma: out of range Compliant with European directive ATEX 94/9/CE and with IECEx schedule for explosion-proof detectors. OLC, OLCT XP, OLCT XP IR : ATEX II 2 GD / Ex d IIC T6 Gb / Ex tb IIIC T85 C Db IP66 OLCT XP HT: ATEX II 2 GD / Ex d IIC T6 Gb / Ex tb IIIC T85 C Db IP66 (for the transmitter to be installed in a cold zone) ATEX II 2 G / Ex d IIC T4..T2 Gb (for the sensor to be installed in the hot zone) OLCT IS Aluminum : ATEX II 2 GD / Ex ia IIC T4 Gb / Ex ia IIIC T135 C Db IP66 OLCT IS Stainless Steel : ATEX II 1 GD / Ex ia IIC T4 Ga / Ex ia IIIC T135 C Da IP66 SIL 2 according to EN 50402 / EN 61508 for catalytic versions, O2, CO, NH3 and H2S Metrological performances according to EN/IEC 60079-29-1 Electromagnetic compatibility according to EN 50270 2 active wires, 2 active wires, 135 (5.433") 78 (3.070 ") (3.937") 179 (7.047") 133 (5.236") O 8 (3.15") M44x1 (1.732") OLC OLCT M44x1(1.732") 86 (3.385 ") 84 (3.307") 138 (5.433") 150 (5.905") 127 (5.0") O 50 (1.968") OLC-OLCT OLCTHT 65 (2.560")

OLCT ORDERING INFORMATION The reference is broken down as follows: OLCT-XP-001-1 Range: Type: Gas: Approval and entry of cable range: OLC OLCT OLCT HT5* OLCT HT10* OLCT HT15* XP IS XPIR Codified from 1 to 999, includes gas and detection range 1 - ATEX and M20 cable entry - Aluminium 3 - ATEX and 3 / 4 NPT cable entry - Aluminium 5 - ATEX and M20 cable entry - Stainless steel 7 - ATEX and 3 / 4 NPT cable entry - Stainless steel *Sensor movable up to 5, 10, or 15 meters using a high temperature cable ACCESSORIES A Calibration cup (6331141) allows introduction of calibration gas on the sensor B Bypass adapter (6327910) allows measurement of samples C Splash guard system (6329004) protects the detector from liquid projections D Remote gas introduction head (6327911) allows introduction of gas without opening the detector E Removable protective filter (6335975) protects the sensor against projections and dust F Duct measurement kit (6793322) allows gas monitoring in a duct G Mounting bracket (6322420) allows the mounting of the detector to the ceiling H Protective cover (6123716) protects the detector against bad weather conditions or against direct sun radiations I Adapter plate (6793718) allows the replacement of another OLDHAM detector without re-drilling J Wall mounted collecting cone (6331169) for use with lighter-than-air gases K Ceiling mount collecting cone (6331168) for use with lighter-than-air gases A B C G H I D E F J K As an ISO 9001 & ISO 14001 approved company, OLDHAM quality assurance programmes demand the continuous assessment and improvement of all OLDHAM products. Information in this leaflet could thus change without notification and does not constitute a product specification. Please contact OLDHAM or their representative if you require more details. EMEAI Arras- France ZI Est, Rue Orfila,CS 20417 62027 ARRAS CEDEX France Tel : +33 (0) 3 21 60 80 80 Fax : +33 (0) 3 21 60 80 00 info@oldhamgas.com AMERICAS Texas- USA 4055 Technology Forest Blvd. The Woodlands, TX 77381 USA Tel : +1 800 247 7257 Fax : +1 704 291 8330 sh-sale@tycoint.com ASIA PACIFIC Shanghai-China 290 Guiqiao Road Pudong, Shanghai 201206 People s Republic of China Tel : +86 21 3127 6373 Fax : +68 21 3127 6365 sales@oldhamgas.com www.tycogfd.com l Copyright 2016 Tyco Gas and Flame Detection. l All rights reserved. l GF-30029B Learn more: www.tycogfd.com