Safety Awareness Bulletin: Upgrading from CMD-2M, CMD-3M and CMD-4M CO Detectors to NEW CMD5-MD 12/24 vdc CO Alarms

Similar documents
Marine Carbon Monoxide Alarm

RV Carbon Monoxide Alarm

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

CARBON MONOXIDE (CO)

Carbon Monoxide Alarm with Safety Shut-Off

CARBON MONOXIDE DETECTION SYSTEMS

CARBON MONOXIDE DETECTOR, i4h-co-m330

Seriously how do you know your CO monitor is Working!

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

SOPHIA S LAW. Nations Toughest Carbon Monoxide Law: Educating Boaters and Changing an Industry

Carbon Monoxide Detectors. What is carbon monoxide?

Frequently Asked Questions About Carbon Monoxide Detectors

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Office of the Fire Commissioner

Protecting Children from Carbon Monoxide Poisoning

Manhattan Fire Protection District

carbon monoxide Preventing carbon monoxide poisoning in your home

Impact of Sophia s Law. Recreational Vessels. Vessel Safety Checks

Carbon Monoxide Safety Information

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Carbon Monoxide Alarm

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Travis County Emergency Services District #1 Standard Operating Guidelines

OPERATING INSTRUCTIONS AND OWNER S MANUAL

HOME FIRE SAFETY. Reference Guide

Model Carbon Monoxide (CO) Alarm Response Policy

After receiving the following letter from a consulting client a discussion on the subject of CO poisoning seemed in order.

Carbon Monoxide Poisoning

Battery Powered Commercial CO Monitor

RV Safety Alarms Education Test

Carbon Monoxide Alarm Owner s Manual

Natural Gas Pipeline Safety. EDM Services, Inc. April 2009

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

Carbon Monoxide Room Alarm Installation and User Guide Part No:

Calaer Marine add-on kit manual. 2kW Calaer air heater 4kW Calaer air heater

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

WELCOME TO ROSEVILLE UNIVERSITY

System-Connected Carbon Monoxide Detectors

Macurco Gas Detection Products

Guidelines for the Design Engineer

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

C0-210 Carbon Monoxide Probe

Commercial Carbon Monoxide Detector Owner s Manual

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

Product Guide for Carbon Monoxide Alarms

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Using it in an enclosed space can kill you.

Special Edition. Routt County Office of Emergency Management. Carbon Monoxide The Silent Killer. What is Carbon Monoxide (CO)?

OWNER S MANUAL for Models:

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL 65 Series Surface Mount Models: , R, MS, R-MS

What Does Propane Smell Like?

ADT Carbon Monoxide Alarm

Carbon Monoxide Alarm User s Manual

Carbon monoxide Knowing more

Monitoring Carbon Monoxide Emission in the Air Using Wireless Application

PAULIN PRODUCTS INDOOR HEATER

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

CO Guardian LLC Document No E. AIRPORT DRIVE Date: 08/25/10 OWNERS MANUAL

Screen for carbon monoxide poisoning instantly to help safeguard your staff with the ToxCO range

OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

Natural Gas Safety In Your Home

B15583/R0/204EN&205EN/U&C 7/12/05 3:20 PM Page 1 BATTERY POWERED CARBON MONOXIDE ALARM. Model Ei 204EN Model Ei 205EN Model Ei 205ENA.

Low Level CO Monitor Owner s Manual

Red Alarm Indicator Light

OPERATING INSTRUCTIONS AND OWNER S MANUAL

TIMOTHY R. SZYMANSKI Instructor

3 Macurco Carbon Monoxide Detector CM-16A

OWNER S MANUAL for Models:

Frequently Asked Carbon Monoxide Questions

BATTERY POWERED CARBON MONOXIDE ALARM WITH DIGITAL DISPLAY. Model Ei206D

CO-9X User Manual 6 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

KM300 Carbon Monoxide Detection System Installation Manual

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

Propane Fume Detection System With Solenoid Valve Control

Product Guide for Carbon Monoxide Alarms

The Vermont Legislative Research Shop

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Mazda North American Operations Irvine, CA

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

Installation and User Guide

Fire Safety & Prevention in our Community

This About Your House answers often-asked questions about carbon monoxide to help you make the right decision to make your home safe.

CO-808S User Manual. Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Battery Powered Carbon Monoxide Alarms Ei207/208 Series

Transcription:

SAB-17-105 July 21, 2017 A Company Safety Awareness Bulletin: Upgrading from CMD-2M, CMD-3M and CMD-4M CO Detectors to NEW CMD5-MD 12/24 vdc CO Alarms CMD-2M/3M CMD-4M CMD5-M Upgrade to CMD5-M CMD-2M or CMD-3M If you have CMD-2Ms or CMD-3Ms there are a few items you need to know to convert to the new CMD5-M: 1. The units mount on the wall or ceiling in the same manner but the hole spacing is slightly different. You can usually use the top hole, drill a new second bottom hole and fill the one old hole with filler or putty. However, be sure to use the pan head screws (flat bottom of head) to mount the new bracket not the countersunk flat head screws used with the CMD-2M/3M back plate. CAUTION - The flat head screws may crack the new CMD5-M bracket when tightened! 2. If there are marks on the wall, an indentation from the old detector or a junction box in the wall you may need the optional adapter plate (P/N 100102 specify white, black or ivory) to cover the area or opening since the CMD5-M is slightly shorter than the CMD-2M/3M. 3. The two power wires connect up the same way be sure to use crimp connectors and wrap with electrical tape for a secure connection.

Step-by-Step Instructions Existing CMD-2M/3M Squeeze cover and remove Bend bottom corner Install new bracket with new and unplug connector prongs outward and pan head screws remove circuit board Remove two screws and bracket New CMD5-M bracket Align holes and rotate detector CMD Adapter Plate with optional mounting slightly clockwise to P/N 100102-W plate attach CMD5 alarm CMD-4M If you have CMD-4M there are a few items you should know about converting to the new CMD5-M: 1. The units mount on the wall or ceiling in a similar manner with the same mounting holes. However, be sure to use the pan head screws (flat bottom of head) to mount the new bracket not the countersunk flat head screws used with the CMD-4M back plate. CAUTION - The flat head screws may crack the new CMD5-M bracket when tightened! 2. If there are marks on the wall, an indentation from the old detector or a junction box in the wall you may need the optional adapter plate (P/N 100102 specify white, black or ivory) to cover the opening since the CMD5-M is slightly shorter than the CMD-4M. 3. The two wires connect the same way be sure to use crimp connectors and wrap with electrical tape for a secure connection.

4. If your units are interconnected the two additional wires get connected the same way as the old CMD-4M. NOTE: All interconnected units must be the same you cannot mix CMD-4Ms and CMD5-MxIs. Note the CMD5-M draws significantly less power (4 vs. 30 ma @ 12 vdc). In addition to all of the great new features with the new CMD5-M CO Alarm, including the battery-powered model, there is another major difference over the CMD-4M that we need to point out. The CMD-4M-RLY is a Relay model that was used for: - Interconnecting multiple units - Shutting down a generator - Both of the above - Sending a signal to a third party monitoring system The new CMD5-M works differently. You can use a standard stand-alone version, or an interconnect ( I ) version if you are just connecting multiple units. This saves you the cost of the relay in every CO alarm. If you are shutting down a generator, you need the interconnect ( I ) version AND an RCM-5 relay control module. The advantage here is you only need one relay per boat, not one per CO Alarm another cost savings. If you are sending a closure signal to a third party alarm system, you need the interconnect ( I ) version AND one RCM-5 relay module per monitoring zone. Again, the advantage here is you only need one relay per zone, not one per CO Alarm additional cost savings. NOTE: 1. If CMD4-Ms are interconnected they all need to be replaced at the same time you cannot mix and match CMD4-Ms and CMD5-Ms, unless they are independent stand-alone units. Also available in black

Model CMD-4M Stand-alone Alarms Interconnected Alarms Old Style for Reference Generator Shutdown Third Party Alarm system CMD-4M-RLY CMD5-MD New Style CMD5-MDI CMD5-MB CMD5-MBI RCM-5 (Dry contact closure only) (Requires add l 12/24V DC power supply) (Requires add l 12/24V DC power supply) I - Interconnect version with two more wires than standard RCM-5 Relay Control Module

Typical Circuits

REMINDER - NEW ABYC Standards for Carbon Monoxide Detectors NEW 2015/2016 ABYC standards require that all boats (diesel and gas powered inboard, outboard and sailboats) manufactured after July 31, 2016 be equipped with CO detectors in all accommodation spaces on the craft. Some states, i.e. Minnesota, have already enacted (effective 5/1/18), or are talking about enacting, a similar regulation. The verbiage in the new standard is stated below: ABYC A-24 CARBON MONOIDE DETECTION SYSTEMS Based on ABYC s assessment of the existing technology, and the problems associated with achieving the goals of this standard, ABYC recommends compliance with this standard for all boats, associated equipment, and systems manufactured after July 31, 2016. The standard goes on to say: 24.4.5 Enclosed accommodation compartment One contiguous space, surrounded by permanent structure that contains all the following: a. designated sleeping accommodations, b. a galley area with sink, and c. a head compartment. d. 24.7.1 A carbon monoxide detection system shall be installed on all boats with an enclosed accommodation compartment(s). NOTE: A cuddy intended for gear storage and open passenger cockpits, with or without canvas enclosures, is not considered to be an enclosed compartment. And then: 24.7.1 A carbon monoxide detection system shall be installed on all boats with an enclosed accommodation compartment(s). In the 2014/2015 standard, the CO detectors were only required on boats equipped with gasoline engines or generators now that they are required on ALL boats with accommodation areas. Installation Installation of the detector should be at eye level for easy monitoring and service. The detector should not be mounted within one foot of corners or other dead air spaces and should not be located within five feet of any cooking appliance.

REMINDER Carbon Monoxide The Silent Killer Carbon monoxide (CO) is generated wherever combustion occurs, including the operation of gasoline engines, as well as heating and cooking appliances. It is invisible, odorless, tasteless, and deadly. Faulty venting or even a wind shift can create a dangerous situation, particularly in confined areas like boat cabins. Typical symptoms of CO exposure can be mistaken for the flu or seasickness, making accurate on board CO detection a necessity. 200 PPM: Slight headache within 2 to 3 hours. 400 PPM: Frontal headache within 1 to 2 hours. 800 PPM: Dizziness, nausea and convulsions within 45 minutes. Insensible within 2 hours. 1,600 PPM: Headache, dizziness and nausea within 20 minutes. Death within 30 minutes. 3,200 PPM: Headache, dizziness and nausea in 5 to 10 minutes. Death within 30 minutes. 6,400 PPM: Headache and dizziness in 1 to 2 minutes. 12,800 PPM: Death in less than 3 minutes. intex CMD5-M CO Alarm Features The intex CMD5-M CO Alarm is used when generator shutdown or multiple locations are not desired. The intex CMD5-MxI CO Alarm is used when generator shutdown or multiple locations are desired. Low Battery Current Draw CMD5-MD Extremely low current draw (<4 ma) permits direct battery connection. Modern Design for Inconspicuous Protection Takes up less wall space with its low profile design. Generator Shutdown Protection When dangerous CO levels are detected, the CMD5-MxI automatically shuts down the generator(s). Multiple Location Warning When one CMD5-MxI alarms, all connected CMD5-MxI alarms sound. Contact Closure to Third Party Monitoring System When the CMD5-MxI alarms, the RCM-5 relay contact can close a circuit to a third party system. How the intex CO Alarm Works The CO Alarm uses a microprocessor to measure and accumulate CO levels. Using the principle of Time Weighted Averaging (TWA), the CO Alarm monitors CO concentration, temperature, and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and is expressed as a percentage. In simpler terms, our bodies prefer absorbing CO to oxygen, and COHb is the ratio of absorbed carbon monoxide to oxygen in the bloodstream. The CO Alarm calculates this COHb as a function of time and determines the appropriate alarm time. O-379 Lake Michigan Dr. NW, Grand Rapids, MI 49534 Phone: 616.735.9380 Fax: 616-735-9381 Website: www.fireboy-xintex.com