Combined Storage and Fan Heater

Similar documents
Contact Details. Please note that some of the contact details on this PDF document may not be current.

TSR Electric Storage Heaters

TSR Electric Storage Heaters

CREDA STORAGE RADIATORS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP16. 08/50740/1 (UK) - Issue 1

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP420 & SP14 SP520 & SP15 SP920 & SP19. 08/19222/9 (UK) - Issue 9

Contact Details. Please note that some of the contact details on this PDF document may not be current.

CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

Contact Details. Please note that some of the contact details on this PDF document may not be current.

JUNEAU JUN. 08/51193/0 Issue 0

Installation and technical manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

FIGARO. 08/52543/0 (UK) Issue 1

Opti-V Fire. Model: PGF20 Instructions

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

INSTALLER AND OWNER GUIDE

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

Dimplex ebrochure PDF

Contact Details. Please note that some of the contact details on this PDF document may not be current.

OPTIMYST WALL ENGINE OMWFC20 RTOPW20 PEM20

DANVILLE DNV20AB, DNV20BR, DNV20BL & DNV20CH

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

Charlotte CRT20AB, Charlotte CRT20BR & Brookline BKL20

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

Installation Instructions & Operating Manual IMPORTANT

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

Technical Specification IRX

Installation and Technical M anual

Lo-Carbon T-series Window & Roof Models

instructions OIL FILLED RADIATOR V V and V551225

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

Oil filled Radiators - Models : OFX750/1000/1500 & OFX750TI/1000TI/1500TI

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

INSTALLATION & USER INSTRUCTIONS

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance

Model 804. Chic, Envy, Mirage, Serenity or Twilight fascia.

Model 801 With Adorn, Icon, Visage, Elegant or Ultimate Fireslide fronts & Model 802 Ultimate, Cosyflame, Fyrside, Nebula & Pizzazz versions

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

irconcentre.co.uk airooncentre.co.uk

Imperial Electric Fires

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

BFH range. Features. Base Unit Heater - BFH range

INSTRUCTION MANUAL. Dimplex XLE Series Heater. Installation and Operating. Models: XLE050 / XLE070 / XLE100 XLE125 / XLE150

Riva2 670 Electric. Instructions for Use, Installation & Servicing. For use in AU & NZ (Australia & New Zealand). IMPORTANT

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

The Visage & Elegance Range of Electric Radiators INSTALLATION & OPERATING INSTRUCTIONS

INSTALLER AND OWNER GUIDE

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

INSTALLER AND OWNER GUIDE. Model 807. Electric Heater. Fitted with one of the following fascia

DYSON CUSTOMER HELPLINE

INSTALLER AND OWNER GUIDE

Operating and installation instructions

MILLI PURE VERTICAL TRIPLE HEATED TOWEL RAIL 900X38 - CHROME

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

Installation Instructions for SHD Series Drawers

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

Imperial Electric Fires

Wall Mount Electric Fire Place with Remote Control

Sunbeam Remote Controlled Tower Fan

INSTRUCTIONS MANUAL INDUSTRIAL WALL FAN (20, 26, 30 ) WITH REMOTE CONTROL

FW971 Integrated Frost Free fridge freezer Manual for Installation, Use and Maintenance

HW3 Handwash Installation and Operating Instructions

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

EH kW Panel Heater

Model: Ecostrad Thermostrip with Remote

User Instruction Manual

Transcription:

TSR Supaslim Combi Combined Storage and Fan Heater Assembly Instruction Manual Automatic Model Nos: 79358S 79368S 75772002S 75772003S Cat. Nos: TSR18CW TSR24CW TSR18ACW TSR24ACW This product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC GDC Group Ltd. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing. A division of the GDC Group Ltd, Millbrook House, Grange Drive, Hedge End, Southampton SO30 2DF

IMPORTANT NOTES: It is important to read these instructions carefully and also note the information given on the heater itself. As these particular instructions refer to the assembly and installation of a new heater, they should be retained by the installer; not left behind for the user as this would invite the dismantling and servicing by unqualified persons. FOR THE USER, there is a separate instruction leaflet explaining how the heater should best be operated. Please see that this leaflet is left with the heater for the user s purposes. A MEANS FOR DISCONNECTION IN ALL POLES MUST BE INCORPORATED IN THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES, THE INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT ELECTRICIAN. CABLE HAVING A MINIMUM T RATING OF 85ºC MUST BE USED. Heaters forming part of a comprehensive space heating system should be wired with their own separate circuit, if however, 1 or 2 heaters are installed as a starter system these may be connected to a 30 amp ring main provided that the instructions below are observed, any further heaters installed must be connected by its own circuit. If connected to a 30 amp ring circuit the total rating of heaters connected must not exceed 3kW, where the circuit supplies a kitchen, or 4kW, where the circuit does not include a kitchen. The storage radiator is designed to run on cheap overnight electricity, therefore the means of connecting the heater to the ring main should include a timer. These should be connected to the supply with 3 core heat resistant cable, the size of which is dependant on heater loading i.e. loading up to 10 amps use 1mm², up to 13 amps use 1.5mm² and for the larger heaters 2.5mm² cable. The heater must not be installed immediately below a fixed socket outlet. This heater must be installed where it is impossible for switches and other controls to be touched by a person using a bath or shower. WARNINGS - THIS APPLIANCE MUST BE EARTHED - SPECIAL ATTENTION MUST BE PAID TO THE SECURITY OF THE HEATER S WALL FIXINGS. THE HEATER MUST BE PLACED ON A LEVEL SURFACE AVOIDING ANY IRREGULARITIES. Two supplies are taken into this heater, both fan heater and storage heater circuits must be connected to the same phase of the electricity supply. IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Storage heaters are not compatible with all types and grades of floor coverings, and in extreme cases damage may occur. It is recommended that before installation of this product, you check that your floor covering is suitable for exposure to continued high temperatures. WALL FIXING: The heater must ALWAYS be mounted against, and fixed to a wall as it will not stand up by itself. A detachable bracket is provided for screwing to the wall, the heater is then placed in position and fixed to the bracket by a screw at each end. The heater must never be unscrewed or moved from the wall bracket whilst it is loaded with bricks. THE HEATER IS VERY HEAVY AND WILL BE DANGEROUS IF ITS WALL FIXING BECOMES INSECURE. Solid Brick and Concrete Walls No. 10 Rawlplug plastic inserts. Drill hole of 8mm dia to a depth of 15mm greater than depth of the insert. Timber Frame Seek specialist advice, some authorities suggest RAWLNUT Panelled Wall, Paramount Board, Chipboard, Plasterboard, etc. Check that the panel itself is adequately fixed to battens etc. Use Rawlplug M5 intersets; drill accurate 10mm dia holes in single skin plasterboard. One fixing should be in studwork. Hollow concrete, Breeze Block and Thermolite Block Walls RAWLPLUG RAWLOK R6054R. Some authorities suggest UNIFIX LB 70/10mm. Use Drill for accurate hole, not hammer or chisel.

PLEASE DON T TAKE CHANCES Site conditions may vary considerably and Creda cannot recommend the correct wall fixings to be used. It is the responsibility of the installer to ensure that adequate permanent fixing has been achieved. Purely for guidance the suggested fixings are made for certain wall materials but this list is not comprehensive or authoritative. Different wall constructions will need different inserts. Note that inserts incorporating plastic may be subject to shrinkage behind a warm storage heater and are therefore not recommended. Wall fixings can be obtained from local stockists CARPETS: For safety, the heater must be positioned in the room so that there is at least 75mm (3 ) free air space all around it; under windows, ensure that curtains, when drawn, cannot touch or cover the heater casing. In order to maintain stability, it is essential that the heater be placed on a level surface and care should be taken to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater. The heater feet are designed to go underneath a carpet rather than standing on it; this permits the weight to be taken on a firm base. Carpet gripper should be removed from behind the heater feet. BRICKS: The heater casing and the heater storage bricks with which it must be fitted, are delivered in separate packages. The brick is common to all heaters, packed in pairs. The brick catalogue number is 791402015. 7935 and 75772002 models have 12 bricks. 7936 and 75772003 have 16 bricks.

1Open bottom flaps on cartonthe corner fitments contain First, turn carton upside down the fixing kit. Stand the heater against the wall in its intended position. Mark the position of the two outside corners of the wall bracket. Carefully place the heater aside, and remove the wall bracket from the heater by removing the screw at each end. Reposition the bracket against the wall using the corner marks for alignment. Mark through slots in bracket, two at the extreme ends and the others spaced evenly between them. The slots are in groups, allowing mortar courses between bricks to be avoided, or battens, etc. to be found for the fixing holes. 2CARPET FITTING Cut the underlay and remove carpet gripper to clear feet, allowing heater weight to be taken on floor proper; lay carpet over feet, slitting it as shown above. It is unnecessary to cut carpet away.

WALL FIXINGS - VERY IMPORTANT 3 When bracket is securely fixed, replace the heater under the bracket angle and You must fit a retaining screw at align screw holes on heaters ends. There each end of the are two fixing slots at each end of heater, heater. allowing different stand-offs for different thicknesses of skirting board. Do not fully tighten these screws until the bricks are loaded into the heater as some settling of the heater may occur. NOTE: NEVER REMOVE THESE SCREWS WITHOUT FIRST UNLOADING THE HEATER. See also figure 2 regarding carpets where appropriate. Note: Max. skirting size is 15 x 120mm. Note that the smallest wall spacing should be used only when the skirting board is of the modern slim type, or there is no skirting board at all. THE HEATER MUST STAND VERTICAL 4 A clear space of at least 3 (75mm) must be left at either side of the heater, and any projections or shelves must be at least 10 (250mm) above the heater casing. Curtains must not be draped around or in contact with the casing. A shelf unit is separately available for fitting above heaters. The top panel and front panel are joined and 5 should be removed as one assembly. To do this, remove the screws fixing the rear flange of the top panel, and remove the screws along the bottom edge of the front panel. Carefully swing out bottom of front panel and lift assembly clear of casing, this operation also removes the control knobs under the flap. Put assembly in a safe place to avoid damage to paint etc. NOTE: Removal of the lower front panel is only possible after the top and main front panel assembly has been removed. First, remove the two black screws situated on the lower front face, then remove the four side screws. The lower front panel will then pull forward, clear of the heater.

ENSURE THAT THE CABLES ARE NOT TRAPPED UNDER THE HEATER LEGS 6 MAINS TERMINALS Storage Heater Circuit 79368S 75772003S 79358S 75772002S RESTRICTED SUPPLY UNRESTRICTED SUPPLY IMPORTANT: For earthing, loosen the earth screws sufficiently to wrap the mains earth wire around it between flat washer and cup washer, and retighten the earthing screw. Both restricted and unrestricted supply wires must be connected to their respective earthing points. Feed the mains cable through the appropriate cable clamp and make connections as marked on the heater. Pull back any slack through the clamp and tighten clamping screw. If mains connection is to be made from the left hand side, at this point the mains lead must be secured to the base of the fan box by fixing the ties provided in the fixing kit through the holes along the rear of the fan box base. CONNECTING THE SUPPLIES RESTRICTED SUPPLY Combi Fan Heater Circuit 79358S & 75772002S 7 hours 79368S & 75772003S 7 hours Charge Rated Period Charge 18 kwh 24 kwh PINK PINK UNRESTRICTED SUPPLY NOTE: The fan heater element is factory set at full rating. If ½ load rating only is required the installer should move the black wire as indicated in the circuit diagram.

7 WARNING Remove the inner front panel; this carries on it s inner face the front insulation slab. Handle this with care, the insulation must not be damaged. REMOVE ALL THE PACKING CARDBOARD FROM INSIDE THE STORAGE BRICK COMPARTMENT, IF LEFT INSIDE IT WILL BE SET ON FIRE WHEN THE HEATER IS SWITCHED ON. ENSURE THAT ALL PACKAGING MATERIAL IS REMOVED FROM THE BRICKS BEFORE FITTING THEM. 8 Temporarily remove one central element to provide access for the rear rank of bricks. Loosen terminals on one of the elements and remove this to allow installation of rear rank of storage bricks. On heaters with 3 or 4 elements remove one of the central ones. 9 Note the way the bricks are positioned in the heater. Otherwise they will not fit. 10 Put in place the rear rank of bricks, pushing them well back against the rear insulation. Replace the element, making sure that the connection is tight. 11 Now, place in position the front rank of bricks, again pushing them back to make room for the front insulation slab which is attached to the front panel.

12 Check that the front insulation slab is properly attached to the inner front panel and refit panel (insulation innermost) to the heater by locating its bottom edge behind the front lip of the chassis, and inserting retaining screws along the top and both sides. With the bricks pushed well back, as mentioned earlier, and the insulation properly aligned, there should be no bulging of this panel and no undue force necessary to fix it. Refit the lower front panel by aligning the four side screws before refitting the front face screws. With the lower front panel in place, the outer panel assembly can be hooked over the rear panel top flange and the screws top and bottom replaced and tightened. Take care not to trap wires or the thermostat capillary between the panel flanges. Ensure all washers are replaced in their original positions. Refit the control knobs under the lift - up flap, taking care to align the flat on each spindle. PLEASE ENSURE THAT ALL POLYSTYRENE AND CARDBOARD PACKING PIECES HAVE BEEN REMOVED. ENSURE WALL BRACKET SCREWS ARE TIGHTENED FULLY. WARNING. When a new heater is run up to temperature, the materials will produce a slight smell for the first few days, these are normally harmless in a well ventilated room. It is best to make these first overnight charges with the Input control knob at Maximum. Caged birds, young children and people with chest ailments are best kept out of the room for this first period. SETTING THE CONTROLS 13 The controls are located under the lockable flap at the right hand corner of the top panel. To adjust the controls on the heater use a coin and engage it in the slot provided on the top surface of the knob. AUTOMATIC CHARGING DEVICE (AUTO-SET Fitted only on ACW models) The Auto-Set Control rations the overnight charge each night by sensing the room temperature. The knob is marked with the numbers 1 to 6, turning the knob to a lower number will reduce the charge consequently, the level of room warmth the next day. Once set, the knob should need no further adjustment and the Auto-Set will maintain automatically the room warmth each day by varying the charge according to the weather. 1. Set the room temperature (output) control knob to setting 4. 2. Turn the Auto-Set Knob clockwise as far as it will go. 3. Leave the heater to run in this condition for two nights in order to quickly disperse the new smell which although slight, is better removed once and for all. 4. Instruct the user to set the Auto-Set down to his chosen setting on the third day. Instructions on this are given in the Users Guide which we ask you to ensure is left with the user. MANUALLY ADJUSTED HEATER (without Auto-Set Control) On this the user sets the overnight charge on the numbered knob marked Input. Setting up procedure; 1. Turn the lnput knob to maximum setting (6) 2. Set the Output knob to setting No. 4. 3. Leave the heater to run in this condition for two nights in order to quickly disperse the new smell. 4. Instruct the user to set the Input to his chosen setting on the third day. Instructions on this are given in the Users Guide which we ask you to ensure is left with the user. Part No. 88014 Iss. No. 4 09/09