Controller - 4 x 1-10 V outputs - BUS/KNX

Similar documents
Detector switch - Dual Tech

Detector switch - Dual Tech SCS

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

SCS motion sensors Surface/wall mounting - PIR

Green Switch HD/HC/HS L/N/NT4658N - AM5658. Technical sheets - Automation MY HOME 1. Front view 8

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

Devices for Special Applications

Configuration tool with screen

Connections, displays and operating elements C D E G H. Installing the control unit

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Passive infrared ceiling sensor

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

Tebis application software

Use of the application program

OPERATING INSTRUCTIONS

DOCUMENTATION IPS640

DOCUMENTATION IPS640

Product and Applications Description

UP 258E11 OPTISENS OFFICE

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Operating instructions

Lighting Management Solutions

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Technical Manual MDT Motion Detector

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Lighting Management Solutions

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Installer Manual KNX Touchscreen Thermostat

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

KNX/EIB - Product database - Application description

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

0701 CO Light, HVAC, Monitoring, Brightness

Sensors SR Programming manual

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Description of the application programme for KNX occupancy detectors version 3.1

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

Tri-level Control HF Sensor

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Sensors SR Programming manual

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Ceiling PIR HS presence detector. Product Guide. Overview. Features

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

DALI MSensor 02 Multi-sensor for DALI system

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

TER Active Room Temperature Sensor (Controller),

Secure connection system

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Labkotec Ice Detector

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

BUS/KNX SOLUTIONS ACTIVE CONTROL OF LIGHTING, SHUTTERS, TEMPERATURE AND SOCKET OUTLETS

Tri-level Control Sensor

Application description

Tebis application software

2. Safety. 4. Function

Integrated PIR detectors

SENSA MRE DDM MR

, ,

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Info-Display xx

lighting management standalone sensors

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Sensors and Detectors

Install intelligent room automation flexibly and future-proofed

IP65 High Bay Dual Sense Sensor

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

11,1 30. Ordering data

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

AddressPro Digital Dimming Technical Product Information

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

IP65 High Bay Dual Sense Sensor

Product and functional description

Connections, displays and operating elements E F. 20s 3min

Tri-level Control HF Sensor

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Movement controller comfort, Flush-mounted (Up) xx, xx

luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Direct Dim Microwave Presence/Absence Detector

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Data sheet. Function description. Benefits

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Transcription:

87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Controller - 4 x 1-10 V outputs - Page 1. Use...1. Technical features...1 3. Dimensions.... 4. Connection... 5. Installation...3 6. Parameter setting....4 7. Communication objects...4 8. Care...6 9. Standards...6 1. USE This device is a power unit used for managing lighting loads. It must be connected to one or more detectors and/or remote auxiliary controls in order to operate. The load(s) can be controlled manually or automatically by the detectors and/or the controls associated with the device.. TECHNICAL CHARAERISTICS. TECHNICAL CHARAERISTICS (continued) Voltage: 100-40 V~ Frequency: 50/60 Hz No load power consumption: 4 W Power side: Power supply: x.5 mm (screw terminals) N L: via normally open relay contact 0-10 V 1.5 mm Control buttons LEARN LED: indicates the learning phase or RESET KNX BUS Indicators (on if output activated) 1 Fluorescent tubes Tungsten halogen bulbs 3 Compact fluorescent bulbs 4 1-10 V ballast Red LED: indicates that the BUS capacity has been exceeded "PROG "PROG & RESET" LED & RESET" button Control side BUS Connection between the compatible peripherals in the offer and the controller: RJ 45 cord or BUS cable to fit RJ 45 connector ( max. 150 m between the controller and the furthest peripherals) KNX Connection between the controller and products in the KNX offer: KNX cable fitted with red, black KNX connector (350 m max. of cable between the power supply and the furthest product. Beyond this distance, repeaters must be used.) The product incorporates positive safety - If there is a peripheral fault on the BUS, the lights come back on automatically after 10 minutes. Product installation: in a suspended ceiling or on a suitable cable tray 1 3 4 4 4 30 V~ 4 x 1000 VA 4 x 1000 VA 4 x 1000 W 4 x 4.3 A 4 x 4.3 A 110 V~ 4 x 500 VA 4 x 500 VA 4 x 500 W 4 x 4.3 A Technical data sheet: S000064191EN- Updated on: 18/05/01 Created on: 06/07/01 1/6

. TECHNICAL CHARAERISTICS (continued) Peripherals compatible with the KNX offer: - BUS detectors: infrared, ultrasound or dual technology - Pushbutton lighting controls, switch and scenario management multifunction controls. 4. CONNEION All the wiring must be carried out with the mains power off. connection 00 ma L4 Usage temperature: -5 C to +45 C Storage temperature: -0 C to +70 C Weight: 580 g Impact resistance: IK04 Penetration by solid and liquid matter: IP0 L3 L L1 3. DIMENSIONS 147 50 50 150 m max. 40 75 Schematic diagram power supply Cat. No. 0 035 1 IP communication module Cat. No. 0 035 43 ETS software Controllers OR Scenario 1: Scenario : connection - USB interface Cat. No. 0 035 47 ETS software 350 m max. /6

4. CONNEION (continued) Using double connector Cat. No. 0 488 68 5. INSTALLATION 1 Mounting On cable tray 1 1/4 Cat. No. 0 488 68 3 1/4 4 or Cat. No. 0 488 7 A W Connects directly to the controller and/or detector. 3 4 3/6

6. PARAMETER SETTING NB: All the wiring must be carried out with the mains power off. Switching the controller on generates an automatic configuration. Configuring the controller means that the wiring can be checked. Compatible peripheral(s) and the controller recognise one another on their BUS. All detectors control all loads. The KNX system must be configured using a PC with ETS software installed. This means each peripheral can be connected to its load. Technical documentation regarding KNX product settings is integrated in the ETS database available from January 01. Pro Relations department: 0810 48 48 48 48 (local call rate in France) Mon-Fri 8 am-6 pm Note: 7. COMMUNICATION OBJES All technical information is available at www.legrandoc.com 7.1 suspended ceiling controllers for dimming (0/10 V ballast) 0 On/Off NRC Ch1 IN_ON/ OFF This object is used for On/Off of control luminaires connected to controller output 1. 1 +/- Dimming NRC Ch1 IN_DIM 3.007 Control_ Dimming (4 bits) This object is used to vary the light intensity of all luminaires connected to controller output 1. Value NRC Ch1 IN_ LEVEL This object is used to modify the level of light of all luminaires connected to controller output 1. 3 On/Off NRC Ch1 OUT_ ON/OFF_STATUS CRT This object gives access to the status of luminaires connected to controller output 1. A 1-bit status (On/Off) is sent. 7. COMMUNICATION OBJES (continued) 5 Enable/ Disable NRC Ch1 IN_ ENABLE/DISABLE 3 Scenario NRC-IN_RECALL_ SCENARIO 17.001 SceneControl This object is used to call scenes which have been configured on the controller. Up to 3 scenarios can be configured. Warning: Each controller output can be controlled in a maximum of 10 scenarios. 67 Scenario NRC OUT_ SCENARIO 17.001 SceneControl TU This object is used to transmit the scenario numbers configured on the peripherals connected to the controller. 9 SCHEDULE NRC IN_ SCHEDULE_ AUTOMATION 1.003 Enable This object is used to block all automated control by detectors connected to the controller. If the object = 1: The detectors are inactive If the object = 0: The detectors control the level of light 6 Fault NRC OUT_BUS_ DEFAUT 1.003 Enable This object is used to block or unblock the output in its present status. Commands will not be recognised. 7 Override NRC Ch1 - IN_ OVERRIDE_ON/OFF bits 1.00 CRT Boolean This object is used to signal a fault on the control bus, a malfunctioning peripheral or disconnected peripheral. If the object = 1: Communication fault If the object = 0: No fault.001 Switch Control ( bits) This object is used to control the state of controller output 1 with the concept of priority: Bits = 01: Output ON Bits = 00: Output OFF Bits = 11: Output forced to ON Bits = 10: Output forced to OFF Like for objects 0, 1,, 3, 4, 5, 7 assigned to controller output 1, objects 8, 9, 10, 11, 1, 13, 15 are assigned to output, objects 16, 17, 18, 19, 0, 1, 3 are assigned to output 3 etc. 4 Value NRC Ch1 OUT_ LEVEL_STATUS CRT This object gives access to the status of luminaires connected to controller output 1. A status with the value of 1 byte (0 100%) is sent. 4/6

7. COMMUNICATION OBJES (continued) 7. Peripherals * The object numbers for the connected peripherals are assigned dynamically when the ETS project is created. The object name is preceded by the 8-digit product identifier. 7..1 Switch type multifunction control, 1 and way - Lighting control mode * On/Off. Ch1_CMD_OUT_ ON/OFF This object is used to send the ON/OFF telegram generated by a short press on the * +/- dimming. Ch1_CMD_ OUT_DIM 3.007 Control_ Dimming (4 bits) This object is used to send the dimming telegram generated by a long press > 0.5 s on the * Value. Ch1_CMD_IN_ LEVEL_STATUS Byte 0 pink LED * On/Off. Ch1_CMD_IN_ ON/OFF_STATUS Bit = 0 blue LED Bit = 1 pink LED - Shutter control mode * Up/Down. Ch1_CMD_SHT_ OUT_UP/DOWN 1.008 Up/ Down This object is used to send the telegram generated by a long press > 0.5 s on the Bit = 0 The shutter goes up Bit = 1 The shutter goes down * Step/Stop. Ch1_CMD_SHT_ OUT_STOP 1.009 Switch This object is used to send, with a short press, the Stop telegram if the shutter is moving and the Step down telegram if the shutter is stationary. * Status. Ch1_CMD_SHT_ IN_POS_STATUS Byte 0 pink LED These communication objects are available for each 7. COMMUNICATION OBJES (continued) 7.. ON/OFF lighting controls, 1 and way - Lighting control mode * On/Off. Ch1_CMD_OUT_ ON/OFF This object is used to send the ON/OFF telegram generated by a short press on the * +/- Dimming. Ch1_CMD_ OUT_DIM 3.007 Control_ Dimming (4 bits) This object is used to send the dimming telegram generated by a long press > 0.5 s on the * Value. Ch1_CMD_IN_ LEVEL_STATUS Byte 0 pink LED * On/Off. Ch1_CMD_IN_ ON/OFF_STATUS Byte = 1 pink LED These communication objects are available for each 7..3 Light level measurement cell * LUX. Ch1_OUT_LUX 9.004 Lux ( bytes) This object is used to transmit the level of light measured by the light level cell (0 65535 lux). 5/6

7. COMMUNICATION OBJES (continued) 7..4 Wall-mounting detectors (flush or surface), detectors for mounting in suspended ceilings, surface-mounting detectors * Presence. Ch1_SENSOR_ 1.018 WT OUT_OCC/ UNOCC Occupancy This object is used to send a telegram concerning presence and end of presence. If object = 1: Presence detected If object = 0: End of presence Warning: End of presence is sent at at the end of the detector time delay. * Presence. Ch1_SENSOR_ IN_OCC/UNOCC 1.018 Occupancy This object is used to receive a detection frame from another detector. If object = 1: Presence If object = 0: End of presence * On/Off. Ch1_SENSOR_ OUT_ON/OFF T This object is used to send the ON/OFF telegram to the actuator. Warning: Whether this object is sent depends on the detector parameter setting mode. * On/Off. Ch1_SENSOR_ IN_ON/OFF_ STATUS This object is used to feed back the load status for On/Off closed loop regulation. Warning: When the Level-Status object is connected, this object cannot be used. * Value. Ch1_SENSOR_ OUT_LEVEL This object is used to check the level of a load as a percentage. This object is used for dimming regulation (open or closed loop). * Value. Ch1_SENSOR_ IN_LEVEL_ STATUS This object is used to feed back the load status for dimming closed loop regulation. Warning: When the ON/OFF-Status object is connected, this object cannot be used. * LUX. Ch1_SENSOR_ IN_LUX 9.004 Lux ( bytes) This object is used for the link with an external light level cell in the case of open loop regulation (internal measurement is disabled). Warning: When the detector is operating in open loop mode, a calibration phase with luxmeter is compulsory. * SYNCHRO- NISATION. Ch1_SENSOR_ IN_SYNCHRO This object is used to integrate a manual control in the control loop. It must be linked to the control object CH_CMD_OUT_ON/OFF. Warning: If the object is not used, following a command the detector will always cut off regulation and switch to override mode. 8. CARE Do not use: acetone, tar-removing cleaning agents or trichloroethylene. Resistant to the following products: - Hexane (EN 60669-1) - Methylated spirit - Soapy water - Diluted ammonia - Bleach diluted to 10% - Window-cleaning products WARNING: Always test before using other special cleaning products. 9. STANDARDS Directive: CE Installation standards: NFC 15-100 Product standards: IEC 60669--1 Environmental standards: - EU Directive 00/96/EC: WEEE (Waste Electrical and Electronic Equipment) - EU Directive 00/95/EC: RoHS (Restriction of Hazardous Substances) - Decrees and/or regulations: ERP (public buildings ERT (workplace buildings) IGH (high-rise buildings) 6/6