Reporting Changes to your Notified Body

Similar documents
Want to know more about the Notified Body? Everything you need to know to help you through the Notified Body process and on to accreditation.

European Regulations of Medical Devices and In-vitro Diagnostic Medical Devices. The Notified Body Point of View

CE MARKING PROCESS & NOTIFIED BODIES

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Annex of the certificate (Page 1/1) Accreditation Scope

Record of Amendments. Version Date Amendment Section/page affected

BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

1. Terms defined in the Construction Products Regulation (CPR)

The PPE Directive and the PPE Regulation

EUROPUMP ATEX Guideline Part II

Declaration of Conformity Declaration of Performance Notes

CE marking & your legal obligations

Certificate of Registration

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

EUROPEAN COMMITTEE FOR ELECTROTECHNICAL STANDARDIZATION (CENELEC) TECHNICAL COMMITTEE No. 62: ELECTRICALEQUIPMENT IN MEDICAL PRACTICE

COMMISSION DELEGATED REGULATION (EU) /... of XXX

Achieve Success with European Medical Device Commercialization. By Russ King

Record of Amendments. Version Date Amendment Section/page affected

CE marking & your legal obligations

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

New Approach vs Standards and Regulation: how it all works

Notification of a Body in the framework of a technical harmonization directive

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

ATEX/05/1/7. In detail:

The European Radio Equipment Directive 2014/53/EU

Business Quality Assurance International Ltd

Working Document on a possible COMMISSION DELEGATED REGULATION

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Regulation (EC) 1272/2008 on Classification, labelling and packaging. (CLP Regulation) DG Environment

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

CE marking of fire-resistant doors the right way!

GNB-CPR Position Paper: Issuance of certificates under CPR

EC Certificate - Full Quality Assurance System Directive 93/42/EEC on Medical Devices, Annex II excluding Section 4

Delegated Regulation (EU) 1059/2010 of 28 September 2010 supplementing Directive 2010/30/EU with regard to energy labelling of household dishwashers

Loss Prevention Standard

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

The Machinery Directive 2006/42/EC

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

The transition requirements of the new Regulation (EU) 2016/425 of the European Parliament and of the Council on personal protective equipment

REGULATION FOR THE CE CERTIFICATION ACCORDING TO THE MEDICAL DEVICES DIRECTIVE

Full Quality Assurance System Directive 93/42/EEC on Medical devices, Annex II excluding (4)

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

(Non-legislative acts) REGULATIONS

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

Role of CE Marking in the Placing on the Market of Electronic Components

EC Certificate - Full Quality Assurance System Directive 93/42/EEC on Medical Devices, Annex II excluding Section 4

HazLoc Essential Guides:

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

Regulation of Alarm Remote Notification Systems

ESSENTIAL REQUIREMENTS CHECK LIST

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Institut pro testování a certifikaci, a.s. Management System Certification Body třída Tomáše Bati 299, Louky, Zlín

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

The New PPE Regulation (EU) 2016/425

(Notices) EUROPEAN COMMISSION

EAK AKREDITEERITAVAD TAVAD VASTAVUSHINDAMISMENETLUSED EAK INF1 2016

EC Certificate - Full Quality Assurance System Directive 93/42/EEC on Medical Devices, Annex II excluding Section 4

OFFICIAL JOURNAL OF ACTIVE IMPLANTABLE MEDICAL DEVICES DIRECTIVE (90/385/EEC)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

The New EMC Directive 2004/108/EC

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

FAQs Radio Equipment Directive (RE-D)

(Text with EEA relevance) First publication OJ EN 12322:1999/A1: Note 3 Date expired ( ) 19.8.

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

An overview of sterilizer equipment standards current and planned. Richard Bancroft Science & Technical Director STERIS

OFFICIAL JOURNAL OF IN VITRO DIAGNOSTIC MEDICAL DEVICES DIRECTIVE (98/79/EC)

EC type approval protocol No. 4 Domestic washing and drying procedures for textiles toys intended for children under 36 months (Rev2)

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

West Virginia University Laser Safety Program

Ireland Details of Market Surveillance Authorities Obligation of Article 17 of Regulation (EC) No. 765/2008

This second part of the lesson & is dedicated to EMC legal aspect and standards.

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

BUSINESS PLAN CEN/TC 239 RESCUE SYSTEMS EXECUTIVE SUMMARY

Centexbel. General certification regulations. Construction products

Shipboard incinerators with capacities up to 4000 kw

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Loss Prevention Standard

The Danish Energy Authority to carry out inspections in June and July 2012

BSOL Modules EC Directives

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY

SOCIALIST REPUBLIC OF VIET NAM CONSTRUCTION. Independence - Freedom - Happiness

Reconciliation table Equipment (Public Safety) Regulations

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Intro. of particular standards for IEC : rd edition 14 MARCH 2017

Valve Manufacturers Association of America

Transcription:

Reporting Changes to your Notified Body Ibim Tariah

1) Requirements & Guidance 2) Reporting Changes - What, When, Why & How 3) Some examples 4) Summary & Questions 2

Requirements of the Medical Directives on Reporting Changes 3

Medical Devices Directives Medical Devices Directive (MDD) 93/42/EEC Active Implantable Medical Devices (AIMD) 90/385/EEC In Vitro Diagnostics Directive (IVD) 98/79/EC 4

MDD 93/42/EEC Quality System Product Annex II Section 3 Annex V & VI Section 3 Annex II Section 4 Annex III The manufacturer must inform the notified body of any plan for substantial changes to the quality system or the product-range covered. The notified body must assess the changes proposed The manufacturer must inform the notified body which approved the quality system of any plan for substantial changes to the quality system. The notified body must assess the changes proposed Changes to the approved design must receive further approval wherever the change could affect conformity with the essential requirements of the Directive or with the conditions prescribed for use of the product. The applicant shall inform the notified body which issued the EC type examination certificate of any modification made to the approved product. 5

IVDD 98/789/EC Quality System Product Annex IV Section 3 Annex VII Section 3 Annex III Section 6 Annex V Section 6 The manufacturer must inform the notified body of any plan for substantial changes to the quality system or the product-range covered. The manufacturer must inform the notified body which approved the quality system of any plan for substantial changes to the quality system. Changes to the approved design must receive further approval wherever the change could affect conformity with the essential requirements of the Directive or with the conditions prescribed for use of the product. Changes to the approved device must receive further wherever the changes may affect conformity with the essential requirements of the Directive or with the conditions prescribed for use of the device. 6

AIMD 90/385/EEC Quality System Product Annex 2 Section 3 Annex 5 Section 3 Annex 2 Section 4 Annex 3 The manufacturer shall inform the notified body of any plan to alter the quality system The manufacturer shall inform the notified body which has approved the quality system of any plan to alter that system shall inform the notified body of any modification made to the approved design. must obtain supplementary approval where such modifications may affect conformity with the essential requirements or the conditions prescribed for the use of the product. The applicant shall inform the notified body which issued the EC type examination certificate of any modification made to the approved product. 7

To determine whether a change is reportable to the Notified Body we need to know 1. Which directive? (MDD / AIMD / IVDD) 2. Which Annex / Conformity Assessment Route? 3. Whether certified via a Quality System Annex / Certificate or a Product Annex / Certificate? 8

Directive Requirements Quality System Annexes The manufacturer must inform the notified body which approved the quality system of any plan for substantial changes to the quality system or the product-range covered. The notified body must assess the changes proposed 9

Directive Requirements Product Annexes Changes to the approved design must receive further approval from the notified body wherever the change could affect conformity with the essential requirements of the Directive or with the conditions prescribed for use of the product 10

Guidance NBOG 2014-3 08/12/2015 11

Guidance NBOG 2014-3 Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System Published November 2014 http://www.nbog.eu/ Includes: Requirements on reporting changes Roles and responsibilities Examples of changes 12

Reporting Changes - What, When, Why & How 13

What & When? Quality System Annexes The manufacturer must inform the notified body which approved the quality system of any plan for substantial changes to the quality system or the product-range covered. The notified body must assess the changes proposed 14

What & When? Product Annexes Changes to the approved design must receive further approval from the notified body wherever the change could affect conformity with the essential requirements of the Directive or with the conditions prescribed for use of the product 15

Why? The Notified Body has to Decide whether the changed quality system still fulfils the requirements Determine and assess whether changes to the quality system could affect the fulfilment of Essential Requirements 16

Why? The Notified Body has to determine appropriate action including: Contract review / Update (as needed) Assessment of the product design dossier Assessment of the quality system or special audit Update / Reissue of the EC certificate Items / implementation for verification at next audit 17

How? NBOG Guidance 2014 Clause 3 & 4: Steps for Manufacturer to assess change Steps for the Notified Body to assess change BSI Form MDD/AIMD or IVD Clause 5.4 Particular Examples: Design Built-in control mechanism Operating principles Design specifications Software Materials Labelling Manufacturing processes, facilities or equipment Sterilisation 18

Examples 19

Change No.1 Device Resorbable bone graft substitute Directive & Classification MDD Class III Certificate Type Annex V Product Quality Assurance Certificate Annex III Type Examination Certificate Change The device is indicated for void filling in the extremities. The manufacturer would like to expand the indications to the spine. Does the change need to be reported to the Notified Body? Yes or No? 20

Change No.1 - ANSWER Device Resorbable bone graft substitute Directive & Classification MDD Class III Certificate Type Annex V Product Quality Assurance Certificate Annex III Type Examination Certificate Change The device is indicated for void filling in the extremities. The manufacturer would like to expand the indications to the spine. Does the change need to be reported to the Notified Body? Yes impact on Product Certificate BSI Product Specialist review including clinical evaluation, risk management and PMS. Reissue of certificate. 21

Change No. 2 Device Daily Wear Contact Lens Directive & Classification MDD - Class IIa Certificate Type Annex V - Production Quality Assurance Certificate Change Change to the packaging materials Does the change need to be reported to the Notified Body? Yes or No? 22

Change No. 2 - ANSWER Device Daily Wear Contact Lens Directive & Classification MDD - Class IIa Certificate Type Annex V - Production Quality Assurance Certificate Change Change to the packaging materials Does the change need to be reported to the Notified Body? No as no substantial change to the QMS Assumes not a new packaging process Change / control may be sampled in next assessment 23

Change No.3 Device Left ventricular assist mobile power supply unit Directive & Classification AIMD (all equivalent to MDD Class III) Certificate Type Annex 2.3 - Full Quality Assurance Certificate Annex 2.4 - Design Examination Product Certificate Change 22 software bug fixes including some related to battery life and motor control Does the change need to be reported to the Notified Body? Yes or No? 24

Change No.3 - ANSWER Device Left ventricular assist mobile power supply unit Directive & Classification AIMD (all equivalent to MDD Class III) Certificate Type Annex 2.3 - Full Quality Assurance Certificate Annex 2.4 - Design Examination Product Certificate Change 22 software bug fixes including some related to battery life and motor control Does the change need to be reported to the Notified Body? Yes impacts on product certificate. Changes will be reviewed by AIMD expert and design Examination Certificate re-issued with history page updated to reflect the change was reviewed. 25

Change No.4 Device Spirometer Directive & Classification MDD Class IIa Certificate Type Annex II.3 - Full Quality Assurance Certificate Change Change of address of legal manufacturer. Legal manufacturer is virtual and all production sub-contracted. Does the change need to be reported to the Notified Body? Yes or No? 26

Change No.4 - ANSWER Device Spirometer Directive & Classification MDD Class IIa Certificate Type Annex II.3 - Full Quality Assurance Certificate Change Change of address of legal manufacturer. Legal manufacturer is virtual and all production sub-contracted. Does the change need to be reported to the Notified Body? Yes. Certificate requires update to reflect the new address. Verification at next onsite QMS visit - product labels, contracts, complaints forwarding (from old address). Plus any other changes to responsibilities / activities etc. 27

Change No.5 Device Solutions for storage and transportation of organs Directive & Classification MDD Class III Certificate Type Annex II.3 - Full Quality Assurance Certificate Annex II.4 - Design Examination Certificate Change Solution manufacturing to be moved new onsite location (aseptic filling), rather than using a subcontractor Does the change need to be reported to the Notified Body? Yes or No? 28

Change No.5 - ANSWER Device Solutions for storage and transportation of organs Directive & Classification MDD Class III Certificate Type Annex II.3 - Full Quality Assurance Certificate Annex II.4 - Design Examination Certificate Change Solution manufacturing to be moved in-house (aseptic filling), rather than using a subcontractor Does the change need to be reported to the Notified Body? Yes Impacts both product and quality system certificates & both require reissue Onsite audits required of both QMS and Microbiology & Sterilisation audit of new aseptic process Product review by Product Specialist and Medicinal Substance Experts 29

Change No.6 Device Dental Instrumentation Directive & Classification MDD Class IIa Certificate Type Full Quality Assurance Quality System certificate Change Change of European Authorised Representative for a US based manufacturer Does the change need to be reported to the Notified Body? Yes or No? 30

Change No.6 - ANSWER Device Dental Instrumentation Directive & Classification MDD Class IIa Certificate Type Full Quality Assurance Quality System certificate Change Change of European Authorised Representative for a US based manufacturer Does the change need to be reported to the Notified Body? Yes Review of labels, IFU, declaration of conformity. Verification of labels, contract, vigilance handling at next onsite surveillance visit Reissue of certificate listing new Authorised Representative 31

Change No.7 Device Vascular Stent Directive & Classification MDD Class III Certificate Type Full Quality Assurance Quality System certificate Design Examination Product Certificate Change Change to IFU layout and colours due to company rebranding Change to manufacturing setting to operate at a tighter target range / tolerance within the existing specification Does the change need to be reported to the Notified Body? Yes or No? 32

Change No.7 - ANSWER Device Vascular Stent Directive & Classification MDD Class III Certificate Type Full Quality Assurance Quality System certificate Design Examination Product Certificate Change Change to IFU layout and colours due to company rebranding Change to manufacturing setting to operate at a tighter target range / tolerance within the existing specification Does the change need to be reported to the Notified Body? No If no technical change to IFU (colours / layout only) If no change to manufacturing within existing limits / specification no NB review required 33

Summary 1. Requirement depends on the conformity assessment route / certification held Product Certificates where may affect conformance with Essential Requirements, product range or device safety and performance Quality Certificates Planned substantial changes 2. Changes will be reviewed in (almost) all NB audits, processes for change control are an integral and critical part of any QMS including appropriate control of subcontractors and suppliers 34

Summary (Continued) 3. It s always best to be open and communicate with the Notified Body 4. If in doubt or for borderline case, summarise the change planned and if it s not considered reportable explain why the Notified Body will either review and agree and accept or not! 35

Questions 36

Contact Name: Title: Address: Ibim Tariah Ph.D Technical Director, HealthCare Solutions BSI Group Americas Inc, 12950 Worldgate Drive, Suite 800 Monument II, Herndon VA 20170. USA. Work: +1 703 674 1994 Ibim.Tariah@bsigroup.com Email: Links: http://www.bsigroup.com/en-us/medical-devices/ 37