CXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability

Similar documents
Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Modular Air-cooled Chillers

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Product Data. Split System Heat Pump

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Trane Family of Terminal Products

Water-cooled chillers with High Speed Centrifugal Compressors

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

CONTACT US. For more information,

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Increase your flexibility.

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw)

UniTrane Ductable Units D-line and B-Line

Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives

Trane. Solutions for Retail Environments

U-Match Systems 12,000 to 60,000 BTU/Hr 60 Hz

Nirvana Cycling Refrigerated Dryers

Fixed and Variable Speed Rotary Screw Compressors R-Series 4-11 kw (5-15 hp)

Product Data. Split System Cooling H-EN. January 2017

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Trane Packaged Systems. Everything comes together perfectly. Read Only

Product Data. Split System Cooling E-EN. November 2016

V-Series. Superior Temperature Control for Small Trucks and Vans

Product Data. Split System Cooling D-EN. August 2016

Product Data Split System Cooling

Trane TruComfort Variable Speed Systems

Temporary HVAC Equipment, Oil-Free Air Compression and Power Generation

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Air-cooled Screw Chillers Model RTAF G Process

Leadership, Innovation, Advanced Technology Synergise Here!

PRODUCT RANGE: ROOFTOP PACKAGE

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

Trane Performance Climate Changer Air Handlers. An air handler for every need.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Modular Air Cooled Scroll Chillers

LG VRF Systems. Air Conditioning Technologies

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Contact-Cooled Rotary Screw Air Compressors. R-Series kw ( hp)

Product Catalog Split System Air Conditioners Odyssey

.2 Section Waste Management and Disposal.

Advance Split

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Product Data American Standard Comfort Controls

Trane Performance Climate Changer Air Handlers. An air handler for every need.

TECHNICAL SPECIFICATIONS

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP

Trailblazer air cooled scroll chillers

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

XStream Water-cooled screw chillers and Water/Water Heat pumps

The most reliable and longest lasting in the industry.*

NFZP Variable Refrigerant Flow Guide Specification

PRODUCT GUIDE

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Precise Temperature Control; Compact Footprint

Performance Climate Changer Next generation air handler from Trane

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

The most reliable and longest lasting in the industry.*

Trane Air Conditioners. Designed to outperform. Built to outlast.

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

GP SERIES Packaged Chillers

Air Cooled Scroll Chiller / Heat Pump

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Variable Refrigerant Flow

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

RECORD SUBMITTAL COVER SHEET

Product Data. Split System Heat Pump D-EN. February 2016

The most reliable and longest lasting in the industry.*

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Reliability, efficiency, and comfort. Trane delivers the whole package.

NQ Series Portable Chillers

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Scroll Water Cooled Chiller

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

XStream Water-cooled screw chillers and Water/Water Heat pumps

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Transcription:

CXAV / CGAV Trane Module Industry top class efficiency and reliability

Trane Module Adopts resin coated blue fins Design registration n pending High-efficiency, high-durability and space-saving Resin coated blue fins come as standard accessories of air heat exchangers to prevent corrosion. Compact design with 43% reduction in size compared to our conventional models. offer installation site flexibility. bility. Best efficiency class in the industry 30HP Model Rated COP 50HP Model 3.93 3.20 (cold water 14 C -> 7 C conditions) Adopts a DC inverter motor Adoption of the DC inverter allows for high energy efficiency at both full and partial loads. For long-term use Prevents corrosion Resin coated blue fins are equipped as standard accessories to the air heat exchanger, preventing corrosion and achieving a long lifetime and excellent durability. Also effective as a salt-damage countermeasure. (Gold fins if the <optional> aspersion attachment is used.) Operable in a range of environments More than 150 static and dynamic operational tests are conducted in order to obtain a high level of reliability to satisfy the needs of our customers. Example of Operational Test Automatic operation tests in harsh conditions such as -15 C or 48 C ambient temperature Automatic cooling operation tests at 43 C ambient temperature and initial 43 C water temperature Automatic heating operation tests at -10 C ambient temperature and initial 4 C water temperature Cooling and heating operation tests after being shut down for several days in an environment at -10 C 2 Succ c essssffu ull tests crit itteerria ia JIS and AHRI operational tests atrated conditions or partial loads ssive start-stop Continuous operation tests and excessive tests Operational tests following rapid changes in load or water volume Protection functionality operation tests assuming refrigerant shortage or fan failure

3.93* high efficiency. Reliability that has passed 150 test criteria. Pursuing the best for over 100 years. Long-awaited, new appearance. COP *30HP Model Highly evolved Trane Module Installation space is reduced to less than half Control multiple units with a single device Compact design with a 43% reduction in size compared to our conventional model (CXAM052) allowing for effective use of available space. Control up to 20 units with a single module controller. Fine control of each unit can be configured within the respective controller panel. Insttal In a llaattiioonn Area reea % Installation Area Installation Area CXAM052 Trane Module Unit controller Great operability without needing a user manual Monitor from yyour computer or smart phone The module controller allows for up to 20 units to be managed from one device, and the 7-inch touch screen enables intuitive operation. The control software not only allows access from computers but b also allows access to the mon monitoring system using mobile term terminals such tablets. as smart phones and tab Single-touch operation, color-changing animations animatio and other features make for an easy-to-read, easy easy-to-operate monitor monitoring screen that is intuitive to chang change. Simultaneous monitoring of multiple facili facilities ities Facility 1 Facility 2 Fa ntro i C Contro Main Controller Tracer ES control software is especially designed for use at large scale facilities, allowing for centralized control of buildings and facilities over a range of sites and realizing improved awareness and control in real-time. Simple Controller Facility 3 DDC Controller Facility 4 3

What are the a Trane Owner Benefits 30 Approx. % increase in efficiency Great cost performance 7 water required for 6 water-cooled type chillers is 5 not required, which reduces 4 IPLV The refrigeration tower and initial costs, running costs 6.02 6.33 4.61 5.7 6.04 4.68 3 and maintenance costs while 2 simultaneously realizing high 1 energy and power savings. 0 30HP 50HP Our conventional model (CXAM) Trane Module (CXAV) Trane Module (CXAV aspersion) Easy to operate The module controller can be easily operated via touch screen where settings can be easily changed and errors rapidly detected. No paper-trail The legal refrigerant ton amount of each unit is less than 20 tons, eliminating the need even when connected to fill out bothersome legal paperwork under the High Pressure Gas Safety Act. Reduced down time Even if a unit under module control fails, control of the remaining units continues. Space saving Compact design means it can be installed on rooftops or outside, allowing for more effective use of existing machinery room space. High scalability Up to 20 units can be controlled with each module controller device. Furthermore, the Trane Control System can be used to expand control and monitoring capacity to up to 160 units. 4

benefits of using Module? Designer / Contractor Benefits Flexible installation sites Compact design allows for effective use of indoor space. Negligible effect on construction time Air-cooled chillers don't require the following refrigeration equipment / construction and hence may even shorten construction time compared with water-coolers. Refrigeration tower / cool water pump installation and operational tests Cool water pipework construction and leak tests Installation of water treating devices N/A Further benefits found in terms of running costs due to the elimination of cool water treatment and supply required for water-coolers. Flexibility as both cooler and heater Performance can be optimized by using the appropriate number of cooling and heating units to meet the load requirements. Energy Management TRANE boasts a lineup of a wide range of products including air-conditioning equipment, system controllers, sensors, software and control applications, and provides comprehensive service from installation through after service. TRANE Total System Support Remote Integrated Management Suggestions, Support and Services Server / Software - Tracer ES Lighting Control Elevator Alarm Management Automated Blind Control Building and Facilities Control Facility Management Dashboard System Controller - Tracer SC Power Monitoring System Air Conditioning Equipment Optimization Exhaust Control Unit controller - Tracer UC Pump, Fan and Spatial Management HVAC System Management Environment Control Industry-standard Web-based Open Protocol for Maintenance Management Emergency Communication System Fire Alarm System Various Inverter Sensors Stairwell and Lift Station Alarm Management Video Monitoring Intruder Detection Access Control 5

Pump Configuration Primary + secondary pump system Body 1 Body 2 Supply temperature sensor Customer-side controller Bypass Body 3 Pressure gauge Body n Expansion tank Return temperature sensor Both primary/secondary pumps prepared by customer Scope of Responsibility For contractors Module 1. Primary/secondary pump selection 2. Primary and secondary pump installation 3. Selection and installation of bi-directional valves for the outlet pipes of each module. Opens the bi-directional valve upon receipt of the operating state signal. Closes the bi-directional valve upon receipt of the shutdown state signal. 4. Selection and installation of components required for pipelines including flow switches 5. Operates the primary refrigeration pump (if stopped) upon receipt of the supercooled water state signal Supply Range 1. Module Body 2. Unit controller 3. 4. Modbus / BACnet Interface Board 5. Temperature Sensor (at inlets/outlets and major pipelines) 6. Minimum / Maximum Flow Capacity for each model Signals 1. Output of operating state and number of operating units 2. Output of supercooled water state when powered off Primary pump system Body 1 Body 2 Supply temperature sensor Body 3 Pressure gauge Body 4 Expansion tank Return temperature sensor Header (if required) Module with primary pump included For contractors Module Scope of Responsibility 1. Output the pump speed configuration signal to the module controller 2. Pressure sensor selection 3. Selection and installation of proportionally controlled bi-directional valves for each secondary coil 4. Selection and installation of catch valve for Module outlet 5. Selection and installation of components required for pipelines including flow switches 6. Retains required water volume to prevent supercooling upon receipt of the supercooled water state signal Supply Range 1. Module (Inverter) with Primary Pump 2. Unit controller 3. 4. Modbus / BACnet Interface Board 5. Temperature Sensor (at inlets/outlets and major pipelines) 6. Minimum / Maximum Flow Capacity for each model Signals 1. Output of operating state and number of operating units 2. Output of supercooled water state when powered off Primary + secondary pump system Body 1 Supply temperature sensor Customer-side controller Body 2 Bypass Body 3 Pressure gauge Body n Expansion tank Return temperature sensor Module with primary pump included+ secondary pump prepared by customer For contractors Module Scope of Responsibility 1. Secondary pump selection 2. Primary pump and secondary pump control 3. Selection and installation of bi-directional valves for the outlet pipes of each module. Opens the bi-directional valve upon receipt of the operating state signal. Closes the bi-directional valve upon receipt of the shutdown state signal. 4. Selection and installation of components required for pipelines including flow switches 5. Operates the primary refrigeration pump (if stopped) upon receipt of the supercooled water state signal Supply Range 1. Module with Variable Flow Rate Primary Pump 2. Unit controller 3. 4. Modbus / BACnet Interface Board 5. Temperature Sensor (at inlets/outlets and major pipelines) 6. Minimum / Maximum Flow Capacity for each mode Signals 1. Output of operating state and number of operating units 2. Output of supercooled water state when powered off Primary pump system Body 1 Body 2 Outlet Temperature Outlet Temperature Inlet Temperature Outlet Temperature Inlet Temperature Body 3 Supply temperature sensor Pressure gauge Outlet Temperature Inlet Temperature Body 4 Inlet Temperature Expansion tank Return temperature sensor primary pump prepared by customer For contractors Module Scope of Responsibility 1. Pump selection 2. Pump control system selection 3. Pressure sensor selection 4. Selection and installation of proportionally controlled bi-directional valves for each secondary coil 5. Selection and installation of bi-directional valves for the outlet pipes of each module. Opens the bi-directional valve upon receipt of the operating state signal. Closes the bi-directional valve upon receipt of the shutdown state signal. 6. Selection and installation of components required for pipelines including flow switches 7. Operates the primary refrigeration pump (if stopped) upon receipt of the supercooled water state signal Supply Range 1. Module Body 2. Unit controller 3. 4. Modbus / BACnet Interface Board 5. Temperature Sensor (at inlets/outlets and major pipelines) 6. Minimum / Maximum Flow Capacity for each model Signals 1. Output of operating state and number of operating units 2. Output of supercooled water state when powered off Operating Range Cold (hot) water outlet configured temperature ( C) 55 50 40 20 18 5 Heating Mode Temperature Region Cooling Mode Temperature Region -10 0 4 11 20 46 Atmospheric Temperature ( C, DB) Heating Mode Cooling Mode Temperature configuration criteria for the atmospheric and hot water outlet temperatures required to supply hot water Temperature configuration criteria for the atmospheric and cold water outlet temperatures required to supply cold water Unit controller Item Standard Accessories Component Prepared Mounting Trane Supplied Components Customer Prepared Components Factory Assembled Construction Site 6 (with externally mounted hot/cold water temperature sensor and Modbus interface) Essential Extra Components BACnet Interface Harmonic Filter Differential Pressure Gauge Coil Guard Soundproof Compressor Cover Aspersion Spray Kit Vibration-Proof Rubber Pad or Spring Mount Hot/Cold Water Pump Pump inverter Snow-proof Hood Strainer Flow Switch Hot/Cold Water Reverse Flow Stop Valve or Solenoid Flow Gauge Power and Signal Cables ()

Standard Specifications Cooling Criteria: cold water inlet 12 C / cold water outlet 7 C Heating Criteria: hot water inlet 40 C / hot water outlet 45 C Cooling Criteria: cold water inlet 14 C / cold water outlet 7 C Heating Criteria: hot water inlet 38 C / hot water outlet 45 C Model 30HP Model 50HP Model 30HP Model 50HP Model CXA V085 CXAV150 CXA V085 CXAV150 Maximum Connectable Units 20 20 20 20 Performance Electrical Characteristics Compressor Air Heat Exchanger Water Heat Exchanger Volume Control Refrigerant Cooling Capacity kw 85 150 85 150 Heating Capacity kw 85 150 85 150 Power supply 200V, 400V / 50Hz, 60Hz / 3-Phase 200V, 400V / 50Hz, 60Hz / 3-Phase Rated Current (Cooling) A 70.4 150.6 68.7 147.0 Rated Current (Heating) A 70.5 141.3 69.1 140.9 Power Consumption (Cooling) kw 22.08 48.26 21.61 46.82 Power Consumption (Heating) kw 22.89 45.11 22.42 44.77 Power Factor (Cooling) % 91 93 92 92 Power Factor (Heating) % 94 93 94 92 Compressor Type Fully Sealed Scroll Fully Sealed Scroll Motor Nominal Output kw 9 15 9 15 Devices 4 4 4 4 Startup Method Inverter Inverter Crank Case Heater W 90 90 90 90 Heat Exchanger Type Fin & Tube Coil Fin & Tube Coil Fin Material Resin Coated Fan Resin Coated Fan Tube Material Copper Tube Copper Tube Number of Coil Columns 3 3 3 3 Fan Type Propeller Fan Propeller Fan Fan Motor Output kw 0.35 1 0.35 1 Number of Fans 4 4 4 4 Rated Airflow L/min 600 906 600 906 Heat Exchanger Type Brazed Plate Type Heat Exchanger Brazed Plate Type Heat Exchanger Material Stainless Steel Alloy Stainless Steel Alloy Rated Flow Rate L/min 242 420 172 305 Pressure Loss kpa 53 141 29 79 Method Cold (Hot) Water Outlet Temperature Control Cold (Hot) Water Outlet Temperature Control Operating Range 0, 10-100% 0, 10-100% Refrigerant R-410A R-410A Refrigerant Circuits 4 4 4 4 Refrigerant Volume kg 9.1 4 9.1 4 9. 1 4 9. 1 4 Control Method Electronic Expansion Valve Electronic Expansion Valve Oil Polyol Ester Polyol Ester Oil 160SZ 160SZ Oil Volume L 3.3 4 3.3 4 3. 3 4 3. 3 4 Weight When transporting kg 1465 1465 1465 1465 When operating kg 1495 1495 1495 1495 Noise Noise db(a) 64 74 64 74 Noise (with options) db(a) 62 69 62 69 Aspersion Apparatus Rated Flow Rate L/min 16.7 16.7 16.7 16.7 (Optional) Permissible Water Temperature Range C 10-30 10-30 10-30 10-30 Operable Temperature Range C >=20 >=20 >=20 >=20 Control Method Solenoid Valve On/Off Control + Fan Speed Control Solenoid Valve On/Off Control + Fan Speed Control Legal Refrigerant Ton 15.6 Legal Refrigerant Ton 18.2 Legal Refrigerant Ton 15.6 Legal Refrigerant Ton 18.2 Legal Refrigerant Ton High Pressure Gas Safety Act Procedure Classification N/A (as long as the same water pipes are not combined with other heat source equipment) Cooling criteria: cold water inlet 12(14) C / outlet 7 C, atmospheric temperature 35 C DB, voltage 200 V/400 V Heating: hot water inlet 38(40) C / outlet 45 C, atmospheric temperature 7 C DB/6 C WB, voltage 200 V/400 V External Appearance 44 3794 43 24 3746 24 4-24v anchor hole 900 Service Space 900 900 Hot/cold water outlet 1000 912 Pump inverter box Hot/cold water inlet 44 43 214 Power cable inlet (from base) 214 900 935 Plate heat exchanger A 2344 Pump Inverter Box Hot/cold water inlet Hot/cold water outlet 262 Hot/cold water outlet (JIS 10K 65A) Connected Devices 1 2 3 4 5 6 7 8 9 10 A (min. value) 1000 2160 3320 4480 5640 6800 7960 9120 10280 11440 Connected Devices 11 12 13 14 15 16 17 18 19 20 A (min. value) 12600 13760 14920 16080 17240 18400 19560 20720 21880 23040 1000 Hook hole for hoisting Hook hole for hoisting Control Panel Power cable inlet (from base) Drain connection port ( 19 barb coupling) 198 774 865 1000 78 94 Drain connection port ( 19 barb coupling) Unit interval: Min. 160 mm Recommended value 250 mm 7

Maintenance Menu Standard Plan Long-term Guarantee Plan Peace-of-mind Precautionary Plan Menu / Plan 1-year plan for supporting safe operation. 5-year free-of-charge repair plan. Robust plan for prevention of unforeseen catastrophic failure. Contract period Consultation available. 1 Year 5 Years Consultation Annual maintenance contract Periodic maintenance inspections (three times per year) Annual maintenance inspections (once per year) Repair and parts free of charge Maintenance prior to summer and winter seasons Cleaning and calibration of equipment based on operating conditions and collected data Comprehensive maintenance including shutting down of the equipment, diagnosis of operating conditions, adjustments, replacements of consumables and more Repair and parts free of charge for failures that occur during the contract period Heat exchanger equipment cleaning Fin/coil cleaning and water heat exchanger cleaning Other options than those listed are also available. Please contact your nearest service center or branch office for details. Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a $13 billion global business committed to a world of sustainable progress and enduring results. ingersollrand.com We are committed to using environmentally conscious print practices. 2015 Ingersoll - Rand Company CG-SLB024-EN March 16, 2015