Operating Instructions

Similar documents
Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Zareba Sensepoint Pro

Operating Instructions

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Operating Instructions

Zareba Metro Gas Detector

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Technical Handbook. Sieger Apex

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Sieger fixed gas detection. Fixed protection from hazardous gas

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Zareba Unipoint controller

MAN0604_Issue 09_ Apex

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Technical Manual. Zareba Sensepoint Gas Detectors

APN0064.P65 Issue 01-06/2000 COMPARISON OF OPTICAL DETECTION SYSTEMS FOR INFRARED HYDROCARBON GAS DETECTION

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

RK-05 Carbon Monoxide Transmitter Operator s Manual

Operation and Maintenance Manual

RK-05 Carbon Monoxide Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

Sieger Apex. Flexibility that meets your requirements

CMF, CMX & CMA series

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

THE BELGIAN PIONEER IN GAS DETECTION

Operating Instructions and Maintenance Manual

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

MICROpeL 75 Combustible Gas Sensor Part Number: PM

EXAMPLES OF HOW TO ORDER

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Lumidor portable gas detection. Portable protection from hazardous gas

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

RK-02 Multi Point Detector Operator s Manual

IRmax & IREX accessories

EXAMPLES OF HOW TO ORDER

VQ600 Series Combustible Gas Sensing Head

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Zareba fixed gas detection. Flexible, low cost fixed-point gas detection solutions

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

RK Multi Point Detector Operator s Manual

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Models TX-KE and TX-KP Toxic Gas Transmitters

Technical Manual. Sensepoint XCD Gas Detector PRE-LAUNCH

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Neotronics portable gas detection. Portable protection from hazardous gas

VQ500 Series Combustible Gas Detector Elements

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Hazardous Area Zirconia Oxygen Systems

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

RK/ RK Carbon Monoxide Detector Operator s Manual

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

ASSEMBLY & OPERATING INSTRUCTIONS

Neotronics Impact & Impact Pro

Combustible Gas/Carbon Monoxide Sample-Draw Detector Operator s Manual

RK CO 2 Transmitter Operator s Manual

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

User manual CTX 300 CO 2

RK-05 Combustible Gas Transmitter Operator s Manual

Technical Manual. Signalpoint Pro

Sensepoint XCD RTD (Remote Toxic Detector) Technical Manual

APPLICATION DATA SHEET

FCHM Hydromatic Pump Control Module

Sensepoint XCL Fixed Gas Detector

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Lamp Supply (Recommended)

3 3SP_O3_5 C Package

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

CT-7 Series Toxic Gas Transmitter Operator s Manual

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

SIL 2. Ultima X Series Gas Monitors CERTIFIED

GAS MONITOR Model Model

Operation and Maintenance Manual

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

Technical Handbook. Sieger DX100 Series Termination Units

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Technical Manual. Series 3000 MkII Gas Detector

testo 316-EX gas leak detector Instruction manual

Model SM100. Aspirated Sampling Module

Technical Manual. Sensepoint XCD Gas Detector

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

TC100N. Fixed Gas Detector Operation Manual

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Transcription:

Operating Instructions Sieger Type 705 CO Sensor and Transmitter for Electrochemical Cells UL Certified 00705A1731

HELPING TO MAKE A SAFER WORLD Ensure that you read and understand these Operating Instructions BEFORE installing or operating any part of the equipment. Please pay particular attention to the Safety Warnings. WARNINGS 1. To maintain safety standards, regular maintenance, calibration and operation of this equipment by qualified personnel is essential. Read and understand this manual completely before operating or servicing the equipment. If further details are required which do not appear in this manual contact Zellweger Analytics Limited or their agent. 2. The Code of Practice regarding 'Selection, Installation and Maintenance of Electrical Apparatus for use in Potentially Explosive Atmospheres' must be complied with at all times. Refer to the appropriate local or national regulations relative to the installation site. Elsewhere the appropriate local or national regulations should be used. 3. Operators must be fully aware of the action to be taken if the gas concentration exceeds an alarm level. CAUTION To maintain safety standards, regular maintenance, calibration and operation of the equipment by qualified personnel is essential. 2

HELPING TO MAKE A SAFER WORLD IMPORTANT NOTICES 1. Zellweger Analytics Ltd can take no responsibility for installation and/or use of its equipment if this is not done in accordance with the appropriate issue and/or amendment of the manual. 2. The user of this manual should ensure that it is appropriate in all details to the exact equipment to be installed and/or operated. If in doubt, the user should contact Zellweger Analytics Limited for advice. 3. If further details are required which do not appear in this manual, contact Zellweger Analytics Limited or one of their agents. HELP US TO HELP YOU Every effort has been made to ensure the accuracy in the contents of our documents, however, Zellweger Analytics Limited can assume no responsibility for any errors or omissions in our documents or their consequences. Zellweger Analytics Limited would greatly appreciate being informed of any errors or omissions that may be found in the contents of any of our documents and to this end we include a form for you to photocopy, complete and return to us so that we may take the appropriate action. 3

HELP US TO HELP YOU To: Marketing Services, Zellweger Analytics Limited, Hatch Pond House, 4 Stinsford Road, Nuffield Estate, POOLE. Dorset. BH17 0RZ. United Kingdom. From: Address: Tel : +44 (0) 1202 676161 Fax : +44 (0) 1202 678011 email : literature@zelana.co.uk Tel : Fax : email : I suggest the following corrections/changes be made to: Chapter... Section... Marked up copies attached (as appropriate): Please inform me of the outcome of this change: Yes / No Yes / No For Marketing Services, Zellweger Analytics Limited: Actioned By: Response: Date: Date: 4

Section CONTENTS 5 Page 1. INTRODUCTION 7 1.1 General 7 1.2 Principle of Operation 7 1.3 Accessories 8 2. INSTALLATION 12 2.1 Unpacking 12 2.2 Sensor Orientation 12 2.3 Terminal Housings 12 2.4 Cable Connections 13 2.5 Fitting Sensors 14 3. FITTING ACCESSORIES 16 3.1 Collecting Cone 16 3.2 Weather Protection Housing 16 3.3 Sample Flow Housing 16 4. MAINTENANCE 18 4.1 General 18 4.2 Cleaning 18 5. CALIBRATION 19 5.1 General 19 5.2 Cross Interference From Other Gases 19 5.3 Sensor Life 19 5.4 Calibration Procedure 20 6. GASSING THE SENSOR 21 6.1 Equipment Required 21 6.2 Calibration Gassing Procedure 21 7. REPLACEMENT PARTS 22 7.1 Terminal Housings 22 7.2 Maintenance Spares 22 8. TYPE 705 SENSOR ALTERNATIVE SYSTEMS 23 9. SPECIFICATION 25

6

1. INTRODUCTION 1.1 GENERAL The Type 705 Carbon Monoxide Sensor is a toxic gas detector certified for installation in a hazardous area. This version uses an Electrochemical (ECC) Sensor, in conjunction with an electronic circuit to form a three wire 4-20mA transmitter. The sensor comprises an aluminium housing containing an Electrochemical Cell with a sintered stainless steel disc forming the face of the sensor. The housing has a 47mm AF body with a 3/4 NPT mounting thread at one end and an M36 accessory thread on the other end. A plastic Filter Housing screws on to the accessory thread and holds a Hydrophobic Barrier in position when accessories are not fitted. There are a number of accessories available for the 705 Sensor which utilise the M36 accessory thread. Refer to Section 8 for alternative systems to which the 705 Sensor can be connected. Note: New sensors are despatched with a protection disc in place of the Hydrophobic Barrier. This disc should not be removed until the sensor is installed or commissioned. 1.2 PRINCIPLE OF OPERATION The sensor contains an Electrochemical Cell. Electrochemical Cells are dynamic devices which generate a current in proportion to gas concentration within the cell. As the current output from the cell is in microamps, it is amplified and processed by the electronics in the terminal enclosure. The resulting signal in the range 4-20mA (representing 0-500ppm CO) can then be connected to equipment in the safe area to provide alarm and concentration indications. 7

1. INTRODUCTION Mounting Thread Accessory Thread Sintered Disc Hydrophobic Barrier (fit white side out) Filter Housing Figure 1 Type 705 Sensor and Filter Housing 1.3 ACCESSORIES 1.3.1 General The following accessories are available for use with the sensors: a. Collecting Cone (Figure 2). b. Weather Protection Housing (Figure 3). c. Sample Flow Housing (Figure 4). d. Hydrophobic Barrier. e. Gassing Point Assembly (Figure 5). 1.3.2 Collecting Cone The detection of a lighter than air gas is enhanced by the use of a Collecting Cone. The cone fits onto the sensor accessory thread in place of the Filter Housing and retains the Hydrophobic Barrier. 8

1. INTRODUCTION A nozzle on the cone permits gassing of the sensor with the cone in position. The test gas is applied either direct to the nozzle or via a permanently connected pipeline when the sensor is fitted in an inaccessible location. 42mm Nozzle 6.35 O/D 77.6mm 165mm Figure 2 Collecting Cone 1.3.3 Weather Protection Housing The Weather Protection Housing, fitted to a sensor installed in an exposed location, affords protection from driving rain from the vertical to 30 below the horizontal. When mounted close to the ground, protection is afforded from heavy rain rebounding off the ground. It also reduces contamination from industrial waste and enables the application of a test gas in high wind speeds without significant error. The housing is fitted to the sensor accessory thread in place of the Filter Housing and retains the Hydrophobic Barrier. Incorporated in the housing is a nozzle to facilitate gassing the sensor with the Weather Protection Housing in position, either by direct application to the nozzle or via a permanently connected pipeline. The nozzle is free to rotate within the housing to allow removal from the sensor without disconnecting a permanently connected pipeline, when changing the Hydrophobic Barrier and cleaning the sensor. 9

1. INTRODUCTION 50.8mm Dia 51.0mm 25.5mm Figure 3 Weather Protection Housing 1.3.4 Sample Flow Housing A Sample Flow Housing provides a means to sample gas from a closed system, via two pipelines. The flow housing is fitted to the sensor accessory thread by a locking ring, enabling removal of the housing without disconnecting the pipeline. The Hydrophobic Barrier is retained by the housing and interfaces with a gasket bonded to the housing. 45mm 31mm 30mm 61mm Figure 4 Sample Flow Housing 10

1. INTRODUCTION 1.3.5 Gassing Point Assembly This assembly can be fixed at a convenient position and permanently connected by suitable tubing to an inaccessible sensor, thus simplifying the application of a test gas when checking the sensor calibration. A DIN rail mounting assembly (00785-A-0069) is available to enable five Gassing Stainless Steel Tube 120mm Dia 25mm Yellow Nylon Block 70mm x 38mm x 19mm Gassing Tube Cap Figure 5 Gassing Point Assembly Point Assemblies to be mounted side by side. 1.3.6 Hydrophobic Barrier The Hydrophobic Barrier consists of a layer of stainless steel mesh with a rubber rim, with a Hydrophobic Barrier of PTFE bonded onto its surface. This MUST be fitted with the white surface facing outwards. 11

2. INSTALLATION WARNING The Code of Practice regarding Selection, Installation and Maintenance of Electrical Apparatus for use in Potentially Explosive Atmospheres must be complied with at all times. Refer to the appropriate local or national regulations relative to the installation site. CAUTIONS 1. Replacement of components by other than Zellweger Analytics Limited authorised engineers will invalidate the instrument warranty and certification. 2. The Type 705 Sensor must never be used in conditions when the flameproof integrity of the sensor and associated terminal housing is impaired. 3. The sintered disc on the sensor assembly must be kept free from contaminants, for example oil and dirt. 2.1 UNPACKING On receipt the equipment must be carefully unpacked, observing any instructions printed on the packaging and the contents checked for deficiencies and transit damage. 2.2 SENSOR ORIENTATION The sensor must be installed with the sensor facing downwards. In exposed locations a Weather Protection Housing should be fitted. 2.3 TERMINAL HOUSINGS A Terminal Housing (Figure 6) provides a mounting base for the sensor and contains the associated electronic circuit. The installation wiring enters the Terminal Housing via conduit. 12

2. INSTALLATION Cable Entry Conduit Cable Entry Conduit Killark Box with 705 Sensor Figure 6 Terminal Housings 2.4 CABLE CONNECTIONS Adalet X1HFC3L Terminal Housing The sensor is connected by three wires to the terminals on the pcb. Connections Colour Code Counter C Brown Working W Blue Reference R White Two 3-way terminals blocks are provided on the pcb in the terminal enclosure to enable connections from the sensor and to equipment in the safe area to be made. For wiring details see Figure 7. 13

2. INSTALLATION Connection Terminals TP3 Span TP2 Offset Zero Circuit Board Assembly Showing Adjustment Controls RFI Shield Plate Figure 7 Connections 2.5 FITTING SENSORS WARNINGS 1. Before installing sensors, isolate the power supply by disconnecting or removing the associated control module from the installation. 2. All electrochemical cells contain acid or a caustic solution. Avoid its contact with skin, eyes and clothing. In case of contact flush with water for at least fifteen minutes. CAUTION The sintered disc on the sensor assembly must be kept free from contaminants, for example oil and dirt. 14

2. INSTALLATION When fitting a sensor to a metal thread, it is recommended that the mounting thread should be coated with an approved anti-seize compound, such as a light petroleum grease. Refer to Section 8 for alternative systems to which the sensor can be connected. When replacing a sensor refer to CAUTION 1 in Section 4 Maintenance Section. To fit the 705 Sensor, proceed as follows: (1) Remove the protection disc and fit the accessories as required. (Refer to Section 3). (2) Isolate the power supply and wait for five minutes. (3) Remove the Terminal Housing lid. (4) Pass the cable into Terminal Housing and fit the sensor to the housing. To comply with certification requirements, a minimum of five threads must be engaged. (5) Connect the sensor cable to the terminal block. (6) After mounting the Terminal Housing in the required location, connect the associated Control Module wiring to the terminal block (see label). (7) Fit the shield plate to the standoff pillars, replace and secure the Terminal Housing lid. (8) If not already replaced by accessories, unscrew the Filter Housing, remove the protection disc and replace the Filter Housing and gasket. Note: The Hydrophobic Barrier is retained in position by the Filter Housing, or one of the accessories. (9) Reconnect to the Control Module. 15

3. FITTING ACCESSORIES 3.1 COLLECTING CONE (00780-A-0032) To fit the Collecting Cone Assembly to a sensor, proceed as follows: (1) Remove the Filter Housing and gasket from the sensor. (2) Fit the Hydrophobic Barrier, ensuring that the white surface faces away from the sinter. (3) Screw the Collecting Cone assembly onto the sensor accessory thread and tighten firmly by hand. 3.2 WEATHER PROTECTION HOUSING (00780-A-2076) To fit a Weather Protection Housing to a sensor, proceed as follows: (1) Remove the Filter Housing and gasket from the sensor. (2) Fit the Hydrophobic Barrier, ensuring that the white surface faces away from the sinter. (3) Screw Weather Protection Housing on to sensor accessory thread and tighten firmly by hand. 3.3 SAMPLE FLOW HOUSING (00780-A-0035) To fit a Sample Flow Housing to the sensor, proceed as follows: (1) Remove the Filter Housing and gasket from the sensor. (2) Ensure that the Sample Flow Housing is fitted with gasket (00780-C-0017). (3) Apply a thin coating of anti-seize compound, such as a light petroleum grease, to the sensor accessory thread. 16

3. FITTING ACCESSORIES (4) Fit the Hydrophobic Barrier, ensuring that the white surface faces away from the sinter. Screw the Sample Flow Housing on to the sensor and tighten with a 40mm A/F spanner. (5) Set the sample flow rate to 1.5 ± 0.1 litres per minute, unless otherwise directed in System installation instructions. 17

4. MAINTENANCE 4.1 GENERAL Maintenance consists of cleaning the sensor and accessories, replacing the gasket and Hydrophobic Barrier and gassing the sensor when testing the system. CAUTIONS 1. The ECC cell contains a small quantity of acid. When disposing of a sensor, it is necessary to comply with the current waste disposal regulations, either local or national ECC TYPE SENSORS SHOULD NEVER BE DISPOSED OF BY PLACING IN A FIRE. 2. Exposure to gas concentrations above the design range may result in the sensor needing re-calibrating or checking. 3. Dismantling of a sensor or a sensor installation by other than authorised engineers invalidates certification. In the event of exposure to contaminant or prolonged exposure to high concentration of gas, the sensor should be operated for 24 hours in a clean environment and then recalibrated. Note: If the sensor is found to be faulty, or cannot be calibrated, the complete sensor must be discarded and replaced. 4.2 CLEANING The sensor and accessories may be cleaned using an industrial grade of methanol. Whenever cleaning takes place, a new Hydrophobic Barrier must be fitted and the following precautions must be observed: a. Isolate the power supply from the sensor by withdrawing the associated Control Module from the installation. b. Do not remove the sensor from the installation. 18

5.1 GENERAL 5. CALIBRATION When testing and calibrating a gas detection system, the sensors must be gassed in accordance with the practice recommended for the particular installation. The sensor should be calibrated with carbon monoxide using the procedures detailed in Section 6. 5.2` CROSS INTERFERENCE FROM OTHER GASES Some gases, other than carbon monoxide, can produce an output current. Those which may be encountered and typical examples of their effect (if any) at 20ºC are as follows: Gas Concentration Indication in ppm H 2 S Carbon Dioxide 5% Less than 1 Chlorine 20ppm Less than ±2 Ethylene 500ppm Less than 425 Hydrogen 1000ppm Less than 100 Hydrogen Sulphide 10ppm Less than 38 Methane 5%v/v Less than 5 Sulphur Dioxide 10ppm Less than 5 5.3 SENSOR LIFE The expected life of the detector assembly is greater than 2 years. The guaranteed life is 12 months in use plus 6 months storage, subject to storage at a stable temperature between -10ºC to +20ºC. This guarantee will not apply to extended use in harsh environments. 19

5. CALIBRATION 5.4 CALIBRATION PROCEDURE Notes: 1. Ensure that the sensor is not pressurised during calibration by blockage of the exhaust (outlet of the Flow Housing). 2. This procedure will produce an upscale output signal which may activate alarms if fitted. Refer to the Warnings in Section 2 Installation before proceeding. (1) Allow a minimum warm-up period of 1 hour after applying power before carrying out this procedure. (2) Insert the Digital Multimeter (DMM), set to read current, in series with the 4-20mA line. (3) Ensure that the sensor is in a gas-free atmosphere then, if necessary, adjust the ZERO control for 4mA on the DMM. (4) Gas the sensor as instructed in Section 6 'Gassing the Sensor'. After 3 minutes, set the SPAN control to obtain a 20mA indication on the DMM for 50ppm CO. (5) If procedures (3) and (4) cannot be achieved, adjust the OFFSET control as follows: a. Connect the DMM (set to read mv) between TP2 and TP3 on pcb. (see Figure 7). b. Adjust the ZERO control to obtain a reading of 0.000V ± 1mV on the DMM. c. Disconnect the DMM. d. Adjust the OFFSET control to obtain an output (at the terminals) of 4mA. e. Repeat steps (3) and (4). Remove the gas adaptor and allow sufficient time for the test gas to escape. (6) Turn off the test gas and check the DMM indicates 4mA. If not, adjust the ZERO control for a DMM reading of 4mA. 20

6. GASSING THE SENSOR 6.1 EQUIPMENT REQUIRED To test and calibrate the gas detection system the following items are required: a. A suitable Calibration Gas Test Kit and a bottle of the appropriate test gas. b. Where sensor accessories are not fitted, a Sample Flow Housing will be required for accurate sensor calibration. Note: Purpose built gassing equipment is available on request from Zellweger Analytics Limited. 6.2 CALIBRATION GASSING PROCEDURE (1) Connect a suitable calibration gas test kit to the sensor gassing nozzle, or to the permanently connected pipeline where fitted. CAUTION Upward pressure on the gassing nozzle of Weather Protection Housings, forces the nozzle against the hydrophobic barrier. Do not rotate the nozzle when fitting the pipeline as this may cause damage. (2) Open the valve of the calibration gas test kit and set the flow rate to 1.5 ± 0.1 litres per minute. (3) Apply the gas to the sensor for a minimum period of 3 minutes. (4) Set up the Control System as instructed in the Control System manual. (5) On completion, shut off the test gas and disconnect the calibration gas test kit. 21

7. REPLACEMENT PARTS Note: When ordering replacements, always quote the complete part number. Where a part number is not listed or known, state type, material, cable entry size and other relevant details. 7.1 TERMINAL HOUSINGS Part No. Description Cable Entry Thread 00704-A-1756 *Killark HKB-BC Box ¾ NPT Bulkhead Mounting (2 entries) 00704-C-1738 RFI Shield Plate for Killark Box 00704-A-1755 *Adalet X1HFC3L Box ¾NPT Bulkhead Mounting (2 entries) 00704-C-1739 RFI Shield Plate for Adalet Box 00705-A-1761 Killark HKB-BC Box (Including Sensor and Electronics) * These two items may be sourced locally. 7.2 MAINTENANCE SPARES Note: When ordering replacements, always quote the complete part number. Part No. 00705-A-1731 00780-A-0032 00780-A-0035 00780-C-0048 00780-A-2076 00910-A-0084 00780-C-0038 Description Sensor Assembly CO (ECC) Collecting Cone Sample Flow Housing Gasket (Flow Housing) Weather Protection Housing (Plastic) Hydrophobic Barrier Filter Housing 22

8. TYPE 705 SENSOR ALTERNATIVE SYSTEMS TOXIC SYSTEMS Safe Area Hazardous Area ASSEMBLY:-00705-A-1761 CONTROL SYSTEM 5700 CONTROL CARDS 05700-A-0401 TO 05700-A-0409 05700-A-3000 INTERFACE CARDS 05700-A-0950 05700-A-0951 05700-A-0952 05700-A-0953 INTERFACE MODULES 05700-A-0201 05700-A-0202 05700-A-0211 05700-A-0212 05700-A-0221 05700-A-0231 705 TRANSMITTER 00705-A-1760 TRANSMITTER 01053-A-4200 01053-A-4201 01053-A-4204 01053-A-4205 705 CO SENSOR 00705-A-1731 705 CO SENSOR 00705-A-1731 23

9. SPECIFICATION CERTIFICATION APPROVALS UL Certified for Class 1, Division 1, Groups B, C and D POWER REQUIRED 16-35V dc. (24V nominal). LINE RESISTANCE/LOAD RESISTANCE Volts Line Resistance and Load Resistance Total The graph shows the maximum resistance allowed (cable + load) between the power supply and the 705 Sensor for various values of supply voltage. Note: For supply voltages above 24V a minimum total resistance of 100 ohms is recommended POWER CONSUMPTION Less than 1W. RESPONSE TIME AT 20 C T 3 20 less than 10s. T 3 50 less than 15s. T 3 90 less than 35s. 24

9. SPECIFICATION OPERATING RANGE ANALOGUE OUTPUT CONTROLS 0 to 500ppm CO, Overrange 0 to 1000. 4-20mA two wire. The sensing resistor can be either connected between the fuse supply and the sensor (sinking current) or connected between the sensor and 0V (sourcing current). 4-20mA represents 0-500ppm CO. ZERO and SPAN potentiometers are accessible through the label plate. AMBIENT TEMPERATURE RANGE Operating: -10 C to +45 C. Will operate at lower temperatures with reduced specification. Operation at temperatures above +50 C or below -20 C for prolonged periods can reduce operating life of the cell. Accuracy: 6 months pure air (-10ºC to+45ºc): Typical baseline change ±15ppm CO. 6 months 500ppm CO exclusive of baseline (-10ºC to +45ºC): Typical span change less tha -150 to less than ±50ppm CO. 25

9. SPECIFICATION Storage (recommended): HUMIDITY RANGE -0º to +20ºC. For prolonged storage it is recommended that the sensor is stored in a sealed container. Range 0 to 90% RH non-condensing. Prolonged operation below 20% RH can reduce operating life of the cell. SENSOR Dimensions: Weight: 78mm x 55mm (47.2mm across flats). 270g TERMINAL HOUSINGS Killark HKB-BC: Dimensions: Weight: 155mm x 135mm x 100mm. 1.13kg. Adalet X1HFC3L: Dimensions: Weight: 115mm x 130mm x 88mm. 1.2kg. COLLECTING CONE Dimensions: 87mm x 165mm dia. Weight: 175g. 26

9. SPECIFICATION WEATHER PROTECTION HOUSING Dimensions: Weight: 76.5mm x 50.8mm dia. 52.4g. SAMPLE FLOW HOUSING Dimensions: Weight: TERMINALS 61mm x 45mm x 31mm. 110g Screw clamped. Accepting cable up to 2.5mm². 27

Find out more www.honeywellanalytics.com Customer business centre Europe and the rest of the world Honeywell Analytics AG Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 sales@zelana.co.uk Customer business center Americas Honeywell Analytics Distribution, Inc. 400 Sawgrass Corporate Pkwy Suite 100 Sunrise, FL 33325 USA Tel: +1 954 514 2700 Toll free: +1 800 538 0363 Fax: +1 954 514 2784 sales@zelana.com www.honeywell.com Issue 3 12/2005 H_MAN0364.P65_V1 2005 Honeywell Analytics 11059