Auto-Diverting Tub Spout Systems

Similar documents
Do Improved Hot Water Systems Result In Efficient Consumer Behaviors Conference Feb 29 Mar 2 Scottsdale, Arizona

How Low Can We Go With Showerhead Flow In Existing Buildings?

Residential Water Conservation Research Brief On-Demand Hot Water Systems

Bidet. Brick. S3512 Bidet mixer n. 2 flexible hoses /4 click clack drain with overflow US $

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

Meeting the One-Cup Challenge

FAUCET & SHOWER SPRING LAUNCH

SPOTLIGHT ON WATER CONSERVATION

Effective Date: January 2018 Void After: January Product: Plumbing Fixture Fittings File No. 6354

Thermostatic tub. Maxima SAMPLE INSTALLATION. S5333/2 (page 47) + S2262 (page 47) S2095 (page 58) S2150 (page 57) + S2172 (page 57)

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

WATER SAVING TIPS SAMPLE. for Your Home

Moen Posi Temp Cartridge Cleaning Instructions Pdf

Energy Efficient Options for Residential Water Heating

EVALUATION SUBJECT: PLUMBING SUPPLY FITTINGS DIVISION: PLUMBING SECTION: INSTRUMENTATION AND CONTROL FOR PLUMBING.

Energy, Water, and Time Efficient Hot Water Systems

Effective Date: not available Void After: Product: Plumbing Fixture Fittings File No. 4079

ABC s of Custom Shower Design

Energy-Efficiency Options for Residential Water Heating

TIMES SQUARE TWO-HANDLE THERMOSTAT

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

Scald Hazards Associated

NEWS SHOWERS FAUCETS INNOVATION SUSTAINABILITY.

americanstandard.com Phone: Fax:

COMMERCIAL VOLUME PLUMBING

Residential Water Heating

Featuring a comprehensive line of tub spouts, single lever escutcheons, shower heads, tub repair accessories, and more

LEAK GUIDE HOW TO IDENTIFY COMMON PLUMBING LEAKS

ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO

Technical drawings. Bio Shock S2216/1 S2190 S2216 S2123 S2199 S2200 S2124 S2199/1

REGULATIONS GOVERNING WATER SERVICE TO CUSTOMERS OF THE EAST BAY MUNICIPAL UTILITY DISTRICT SECTION 31 WATER EFFICIENCY REQUIREMENTS

GOING DIGITAL IN THE KITCHEN AND BATH WITH MOEN Products with Technology to Help Make Life Easier

Moen Commercial Products Eco-Performance Product Guide

Domestic Hot Water Systems and Plumbing Products

WARRANTY POLICY & RECOMMENDED MAINTENANCE

WATER EFFICIENT PRODUCTS AT-A-GLANCE

Renovation Solutions For Projects. Attractive Solutions for Shower, Bath, and Kitchen. hansgrohe. Meet the Beauty of Water.

LEAP FORWARD WITH GROHFLEX

THE RINNAI LUXURY SERIES TANKLESS WATER HEATERS ENERGY-EFFICIENT HOT WATER NEVER LOOKED SO GOOD

Walk-In Baths. Independent living, in safety and comfort.

Shower Column and Shower Seat Catalog

Thermostatic shower. De Soto SAMPLE INSTALLATION. S3253/1 (page 16) + S2261 (page 16) S2239 (page 18) + S2172 (page 18) S2229 (page 18)

PRO SERIES IMPORTANT SAFETY INFORMATION

Tri-Max Aerator GPM. Three flow rate options Patented FlexFlo technology Dual-thread brass connection

IT WON T JUST MEET YOUR HOT WATER NEEDS.

Hot Water Distribution System Losses in a Net-Zero Home

Thermostatic shower. Mp1 SAMPLE INSTALLATION. S5573/1 (page 32) + S2261 (page 32) S2200 (page 35) + S2123 (page 35) S2218 (page 35) + S2190 (page 35)

Introduction. Faucets. Showers

KAFKA BASIN K K K K K [180] 5.9 [158.7] 7.1 [180] 6.3 [159.7] 12.1[307.1] Ø2 [50] 5.9[148.7] 12.8 [325.

Every Drop Counts: Conserve WATER. Pamela R. Turner, Ph.D. Laurie Cantrell, MHS Winter School - January 22, 2008

Advantage Series Bathing System Specifications

360 Series Waste & Overflow System. Installation Manual and User Guide

Saving water in Scotland? Really? Free water saving gadgets to help you use water wisely and save energy and money

March

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

endless comfort and performance TANKLESS WATER HEATING SOLUTIONS FOR THE HOME

It Won t Just Meet Your Hot Water Needs IT WILL EXCEED THEM. RH180 HYBRID TANK-TANKLESS WATER HEATER

HOT WATER WITH THE SNAP OF A FINGER. Mini Tanks. Basic Heaters. High Capacity Heaters. Model CMT. Model SR, M & E. Model ER Series

EVALUATION SUBJECT: LOW LEAD - PLUMBING SUPPLY FITTINGS, FLEXIBLE WATER CONNECTOR

The Perfect Shower Starts Here

Reaching New Heights in Efficient Water Heating Technologies

Minnesota Multifamily Rental Characterization Study

Water is a resource shared by all, and as Florida s population increases, so does the need for all of Florida s residents to conserve.

The smart way to instant hot water comfort.

It won t just meet your hot water needs. It will exceed them. RH180 Hybrid Tank-Tankless Water Heater

Urban World Activity. Saving Water

Visit. MirabelleProducts.com for full specification sheets, parts breakdown, and installation instructions

Optional Handle Trim Key

Effective Date: June 2017 Void After: June Product: Plumbing Fixture Fittings File No. 4995

TO ORDER PARTS CALL: BUY-MOEN Rev. 8/14. HandShower (2.5 GPM)

2010 PROCard PowerGuide

Savings Without Sacrifice

WHERE THE WATER IS FLOWING

A Model of In-Home Hot Water Distribution Systems Energy Losses Using EPANET, Public Domain Software For Pipe Networks

Water Heaters. energy-efficient Hot Water Never Looked So Good #1 PRODUCT FOUR CONSECUTIVE YEARS IN BUILDER MAGAZINE S FAVORITE 50

Indoor Water Use SECTION 31 REGULATIONS AND CALGREEN CODE COMPLIANCE. Fixture & Appliance Requirements. Water Efficiency Review

PDF // REPLACE BATHROOM FAUCET CARTRIDGE DOWNLOAD

The FAWSsit USER CARE GUIDE

"Best Practices in Modern Hydronic Heating - THE DETAILS

Product Bulletin October 12, 2010 Volume 2010 Issue 015

Honeywell Water Solutions. Thermostatic Mixing Valves

Water Conservation Information. Regarding water well pump selection

Performance Monitoring of Residential Hot Water Distribution Systems

Features Luxier SP21-SS

endless advances for your customers WATER HEATING SOLUTIONS FOR BUILDERS

FAUCET CARE AND MAINTENANCE GUIDE. Answers to frequently asked questions about how to keep your Delta faucets at their best.

Faucet Care and Maintenance Guide. Answers to frequently asked questions on how to keep your Delta faucets at their best

energy-efficient Hot Water Never Looked So Good

PORTABLE SMART WASHER

Support. Products. Newsletter

This presentation is posted for public use. ACEEE does not endorse any product or service.

EVALUATION SUBJECT: PLUMBING SUPPLY FITTING

How to care for your water storage tank

The frequency of maintenance and service correlates with the frequency the pressure washer is used.

A New Day Has Dawned. in Solar Pool Heating

Installation Instructions / Warranty. Massaud

Effective Date: July Rev. 1/26/2018- Void After: July Product: Plumbing Fixture Fittings File No. 3474

40 Years of Smart Growth Arlington County s Experience with Transit Oriented Development in the Rosslyn-Ballston Metro Corridor

DOMESTIC STEAM GENERATOR Installation Instructions

Product Specification

Transcription:

Tub/Shower Technologies Auto-Diverting Tub Spout Systems

Core Product Lines ShowerStart TSV Reduces showerhead flow to trickle once bathing temp water arrives (95F) Auto-reset for next shower Universal showerhead compatibility Solid brass construction Easy installation UPC certification For use with water pressures > 30 psi Standard Showerheads Also Available ShowerStart Showerheads ShowerStart TSV 2.0, 1.75 and 1.5 gpm models available Full body spray pattern Multifunction models also available Rub clean spray nozzles Pressure compensating flow regulation Solid brass fittings WaterSense & cupc certification For use with water pressures > 30 psi ShowerStart Handshowers ShowerStart TSV 2.0, 1.75 and 1.5 gpm models available Full body spray pattern Multifunction models also available Rub clean spray nozzles Pressure compensating flow regulation 59 stainless steel hose with solid brass fittings Shower arm mount with solid brass fitting WaterSense & cupc certification For use with water pressures > 30 psi Single & Multi Function Showerheads 2.0, 1.75 and 1.5 gpm models available Full body spray pattern Multifunction models also available Rub clean spray nozzles Pressure compensating flow regulation Single & Multi Function Handshowers 2.0, 1.75 and 1.5 gpm models available Full body spray pattern Multifunction models also available Rub clean spray nozzles Pressure compensating flow regulation 59 stainless steel hose and shower arm mount NOTICE: Copyright 2014 Evolve Technologies LLC. The information contained in this presentation is confidential and is not to be distributed or viewed without the written consent of Evolve Technologies LLC. U.S. Patents 7,681,804,, 7,878,417, 8,434,693 and 8,464,962; Canadian Patent 2,650,304; European Patents 2058567 and 1841991; Mexico Patent 273966; New Zealand Patents 556644 and 572339. Additional US and Foreign Patents Pending.

Understanding Behavioral Waste Behavioral waste occurs when bathers use their time comfortably and efficiently while waiting for hot water to reach the shower. Instead of patiently waiting for cold water to exit the showerhead most people leave to do something else. SHOWER WARM-UP WASTE STRUCTURAL WASTE COOLED-OFF WATER TO CLEAR FROM THE PIPE BEHAVIORAL WASTE WATER THAT IS HOT ENOUGH, BUT RUNS DOWN DRAIN 29% Wait By Shower 19% Occasionally Multitask 2008 Shower Behavior Survey 153 Respondents 71% multitask 52 % perform multiple activities 60% only return after activities are completed 52% Habitually Multitask NOTICE: Copyright 2014 Evolve Technologies LLC. The information contained in this presentation is confidential and is not to be distributed or viewed without the written consent of Evolve Technologies LLC. U.S. Patents 7,681,804,, 7,878,417, 8,434,693 and 8,464,962; Canadian Patent 2,650,304; European Patents 2058567 and 1841991; Mexico Patent 273966; New Zealand Patents 556644 and 572339. Additional US and Foreign Patents Pending.

Anatomy Of A Shower Warm-Up Lawrence Berkley National Lab Data Analysis 120 F WARM-UP WASTE SOURCE: 2014 Disaggregating Residential Shower Warm- Up Waste An Understanding and Quantification of Behavioral Waste Based On Data From Lawrence Berkeley National Lab 110 F BATHING TEMP PLATEAU 100 F 90 F ~40% of warm-up waste volume ~60% of warm-up waste volume 80 F 70 F 60 F 50 F STRUCTURAL WASTE BEHAVIORAL WASTE BATHER ADJUSTS TEMP DOWN FOR COMFORT (105 F 100 F) & BEGINS SHOWERING 0:00 0:45 1:30 2:15 3:00

Behavioral Waste Estimates From Field Research Based on primary and secondary research from LBNL as well as 3 rd party pilot studies Behavioral Waste is approximately 1 minute per shower taken. 2004 Secondary Research via REUWS 2011 Small Pilot Study 2013 Evolve Analysis of Field Data n = 18 bathrooms / 283events 2014 Multifamily Pilot Study n = 240 apartments (120 control) 2015 Pilot Study n = 22 bathrooms / 581 events 39-59 Seconds ~ 60 Seconds 59 Seconds

What If Californian s Eliminated Behavioral Waste? 26 Billion Gallons Water/Year in California 100 Million Therms/Year in California 3 Billion kwh/year in California + or 11.5 years of drinking water for everyone in CA (58 gallons person/year) 185k cars gasoline fueled for a year (13K miles per year) 260K homes electricity consumption for a year (11,320 kwh home/year)

Shower Warm-Up Research - Survey Results The majority of bathrooms have tub/shower combos, the tub spouts leak and multitasking while water is running out of the tub spout is common place. 62% TUB/SHOWER COMBOS 34% LEAKY TUB SPOUT 40% TUB SPOUT WARM UP 58% MULTITASK 648 of the people surveyed reported that they typically shower in a tub/shower combination unit 220 showering in a tub/shower combo unit report that their tub spout leaks during their showers 258 people with tub/shower combo units warm their shower by letting the water run through the tub spout and activating the diverter AFTER the water becomes warm 149 people doing tub spout warm ups regularly or occasionally leave to do something else while waiting for the water to become warm multitasking during tub spout warm up causes significant waste Tub Spouts Flow At 4 to 7 Gallons Per Minute BEHAVIORAL WASTE NOTICE: Copyright 2014 Evolve Technologies LLC. The information contained in this presentation is confidential and is not to be distributed or viewed without the written consent of Evolve Technologies LLC. U.S. Patents 7,681,804,, 7,878,417, 8,434,693 and 8,464,962; Canadian Patent 2,650,304; European Patents 2058567 and 1841991; Mexico Patent 273966; New Zealand Patents 556644 and 572339. Additional US and Foreign Patents Pending.

Solution Employ A Systematic Approach enjoy more PROMOTE CONVENIENCE GAIN EFFICIENCY use less TM Auto-Diverting Tub Spout System

Auto-Diverting Tub Spout System How It Works

4 Key Hot Water Wastes In Tub/Shower System STRUCTURAL WASTE BEHAVIORAL WASTE TUB SPOUT LEAK HIGH-EFFICIENCY SHOWER residual cold water in line that must be purged before hot water can arrive hot water running down shower drain before bather begins showering water exiting tub spout while bather is showering water used after bather enters and is showering DURING WARM-UP WHILE SHOWERING

Auto-Diverting Tub Spout System Thermal Imaging

Enjoy More Wait Less / Waste Less Because the system warms your shower by first running water through the tub spout, you ll greatly reduce warm-up waits. Not only will your hot water arrive up to 2X faster, but the increased velocity actually decreases the volume of cold water that must be purged before hot water arrives.

Anatomy Of A Tub Spout Warm-Up - Example WARM-UP WASTE SW BEHAVIORAL WASTE ENTRY POINT 120 F 110 F 100 105 F BATHING TEMP WATER 100 F 85% 90 F 80 F Tub Spout Warm-Up 70 F 60 F 50 F 0:00 0:45 1:30 2:15 3:00 NOTICE: Copyright 2014 Evolve Technologies LLC. The information contained in this presentation is confidential and is not to be distributed or viewed without the written consent of Evolve Technologies LLC. U.S. Patents 7,681,804,, 7,878,417, 8,434,693 and 8,464,962; Canadian Patent 2,650,304; European Patents 2058567 and 1841991; Mexico Patent 273966; New Zealand Patents 556644 and 572339. Additional US and Foreign Patents Pending.

A Dramatic Impact On Eliminating Warm-Up Waste WARM-UP WASTE SW BEHAVIORAL WASTE 85% at 5 gpm Eliminates A Much Larger Percentage of Warm-Up Waste At A Much Higher Flow Rate 5 gpm vs. 2.5 gpm NOTICE: Copyright 2014 Evolve Technologies LLC. The information contained in this presentation is confidential and is not to be distributed or viewed without the written consent of Evolve Technologies LLC. U.S. Patents 7,681,804,, 7,878,417, 8,434,693 and 8,464,962; Canadian Patent 2,650,304; European Patents 2058567 and 1841991; Mexico Patent 273966; New Zealand Patents 556644 and 572339. Additional US and Foreign Patents Pending.

Enjoy More A Welcome Diversion By automatically sending hot water to the showerhead once it arrives the system eliminates waiting, waiting, waiting for the right time to pull the diverter pin. This tub spout has the clout to know when the water s hot and magically sends it on its way.

Enjoy More Stop Looking At Leaks Ever look down while showering and see water running out of the tub spout? That s a leak and, on average, it wastes nearly a gallon of hot water per minute. Our tub spout s design prevents tub spout leaks and directs hot water where you ll want it most your showerhead.

Tub Spouts Frequently Leak And Waste A Lot Of Hot Water Surveyed approximately 130 apartments and houses, with a total of 120 combination bath/shower units with diverters Found 34% of the diverters leaked more than 0.1 gpm. Average of those leaks was.8 gpm. > 5 gal WASTED if tub spout is leaking > 2 gal WASTED overall average AVG. SAVINGS 1,500 gallons per household / year

Tub Spouts Frequently Leak And Waste A Lot Of Hot Water

Benefits The Trickle Tells The Trickle Tells Because it trickles by default, the system s showerhead let s you know the moment your shower s warm without wasting hot water while you re away. When you re ready to step into the shower, simply pull the showerhead s cord to begin normal flow and start showering.

Unique Water & Energy Savings Opportunities.4 GALLONS SAVED 5.1 GALLONS SAVED 4.5 GALLONS SAVED UP TO 5.0 GALLONS SAVED Structural Waste Behavioral Waste Anti-Leak Tub Spout High-efficiency Shower head SAVE UP TO 15 GALLONS SAVED PER SHOWER SOURCE: Calculating Savings For Auto-Diverting Tub Spout System With ShowerStart TSV, December 2015

WaterSense & Uniform Plumbing Code Compliant EPA WaterSense SYSTEM LEVEL SHOWERHEAD IAPMO IGC 244-X Uniform Plumbing Code

Tub Spout Leaks WHY DOES MY TUB KEEP RUNNING WHEN I TURN ON MY SHOWER?

WaterSense Is Creating A Tub spout Standard But It s A Problem That s Hard To Message & A Problem Consumers Don t Readily Recognize How do you know when your feet are too wet when you re showering?

Thank You Alan.Work@ThinkEvolve.com