The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

Similar documents
The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

Wireless DC Voltage Detector

Wireless Light Detection Sensor

Wireless Thermocouple Sensor

Wireless Duct Temperature Sensor

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Wireless 0-5 Volt Meter Sensor

Smart Monitoring Systems. for Property Management SMART SOLUTIONS. Property Management DOORS & WINDOWS TEMPERATURES LIGHTS CARBON MONOXIDE

Frequently Asked Questions

TotalPac X Single interlock SUREFIRE system

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Ion Gateway Cellular Gateway and Wireless Sensors

TotalPac X Firecycle III Preaction Double interlock system

HOBO U30 Remote Monitoring Systems

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Architectural and Engineering Specification for a. Flash / Flare

Smart Security, Always Connected

Monnit Wireless Local Alert. User s Guide

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

ENCLOSURE COOLING. Glossary

Selecting an Electrical Enclosure

Ross SysCon Control Panels

Operation and Maintenance Manual

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Architectural and Engineering Specification for a Real-Time Locating System Flare

Panel XTO210/610/710 GPRS

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

REMOTE MONITORING AND ALARM SYSTEM

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Industrial Grade Gas Detection

Quick Touch Pendant User Guide

Quick Touch Pendant. Quick Touch Pendant. Battery

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

Photoelectric Beam Detector

Custom Duct Heaters. Special Applications

AirTest Technologies Inc.

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Exceptional data integrity. Complete peace of mind.

Essential Insight.mesh Wireless System,

environmental chambers for Battery testing

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

SAFESITE Multi-Threat Detection System

Solar-Powered BLE Sensor Beacon 5 Pack Kit Guide

The PBE Group. Industries We Serve. PBE Catalogue

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Fiber Optic Cable Fence Disturbance Sensor

Smart Wireless Sensor

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Industrial Grade Gas Detection

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

GLD-30 Gas Leak Detector

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Guide To Troubleshooting INEFFICIENT COOLING FANS

Toxic Gas Detection. Model F12. Toxic Gas Detection

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc

CONTROL YOUR HOME FROM EVERYWHERE

Consumer Products Catalog

Mobeye is a Dutch manufacturer of GSM alarm and security products. Mobeye is

Q3200 Smart Home Alarm. Kit Content and Installation Guide

products and services

Smart Wireless Sensor

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Custom Duct Heaters. Special Applications

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

Hydronic & HVAC Control Systems

RAPID Alert System User Guide. RAPID Alert System. User Guide

Hazardous Area Ringdown Telephone

Options for Diesel Fire Pump Controllers

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

K100A Insertion Probe Thermometer

Honeywell Temperature & Humidity Sensor with LCD

WAVE SEQUENCER DELIVERS:

New Recognition Certification for Access Hardware INDUSTRY ARTICLE

Panel XT210/610/ Description. Supervised Wireless Technology

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Section PERIMETER SECURITY SYSTEMS

User Guide. Alert. Locate. Respond. A Mobile Worker Safety Device Complementing Loner Mobile. SureSafe Safety Monitoring confirmation light

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Personal Assistance System Owner s Manual

MINI RECEIVER. Installation and Operation Manual. Model # MR1214-MC 418 MHZ RECEIVER. Document #

Organization Summary and Directory. Standards Organization Summary and Directory Overview. Technical Information: Standards

wireless. web-based. worthy of the name RACO.

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

Cold chain monitoring technologies. Facility monitoring

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Transcription:

Wireless Dry Contact Sensors by The Leading Enterprise Internet of Things Solution General Description ALTA wireless dry contact sensors can be used to detect contact between two wired contact points, an external mechanical switch or a contact plate. 1 ft. (12 inch) lead wires. Can integrate with switches. Principle of Operation The ALTA wireless dry contact sensor detects when there is contact between the two wired end points. It can easily be integrated into existing switches or contact plates. When the sensor detects contact between the two end points, it will immediately turn on the RF radio and transmit the data to the wireless gateway and imonnit Online Sensor Monitoring and Notification System, allowing the user to immediately receive an SMS text or email alert. The sensor can be configured to detect both closed and open loops alerting if contact is made or broken. Example Applications Barn door monitoring. Freezer / cooler door monitoring. Forklift seat switches. Button or switch integration. Production line tracking. Features of Monnit ALTA Sensors Wireless range of 1,000+ feet through 12-14 walls.* Frequency Hopping Spread Spectrum (FHSS). Improved interference immunity. Improved power management for longer battery life.** (10+ years on AA batteries) Encrypt-RF (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages). Onboard data memory / storage (up to 512 readings per sensor). - 10 min heartbeats = 3.5 days - 2 hour heartbeats = 42 days Over-the-air updates (future proof). Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email. * Actual range may vary depending on environment. ** Battery life is determined by sensor reporting frequency and other variables. Other power options are also available. Comparison Monnit Monnit ALTA Other Wireless Platforms Wifi Bluetooth PAGE 1

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) ALTA Commercial Coin Cell Wireless Dry Contact Sensor - Technical Specifications Supply Voltage 2.0-3.8 VDC * Operating Temperature Range (Board Circuitry and Coin Cell) -7 C to +60 C ( 20 F to +140 F ) ** Optimal Battery Temperature Range (Coin Cell) +10 C to +50 C ( +50 F to +122 F ) 0.7 Ounces PinchPower Enclosures _ CR2032 BATTERY CR2032 BATTERY + Pinch (press in on the sides) Pull (sensor away from base) Press (sensor back into base) PAGE 2

2.470 2.470 4.375 3.295 1.111 1.111 ALTA Commercial AA Wireless Dry Contact Sensor - Technical Specifications Supply Voltage 2.0-3.8 VDC (3.0-3.8 VDC Using Power Supply) * Operating Temperature Range (Board Circuitry and Batteries) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 85 C (-40 F to 185 F) using lithium ** Optimal Battery Temperature Range (AA) +10 C to +50 C ( +50 F to +122 F ) 3.7 Ounces Power Options The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0-3.6 V power supply. The line powered version also uses two standard 1.5 V AA batteries as backup for un-interupted operation in the event of line power outage. Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) ALTA Industrial Wireless Dry Contact Sensor - Technical Specifications Supply Voltage 2.0-3.8 VDC (3.0-3.8 VDC Using Power Supply) * Operating Temperature Range (Board Circuitry and Battery) -40 C to +85 C ( -40 F to +185 F ) ** Included Battery Max Temperature Range: -40 to +85 C ( -40 to +185 F ) Capacity: 1800 mah Optional Solar Feature Solar Panel: 5VDC / 30mA (53mm x 30mm) Enclosure Rating Charging Temperature Range: Max Temperature Range: Included Rechargeable Battery: 0 to 45 C (32 to 113 F) -20 to 60 C (-4 to 140 F) 600 mah / >2000 Charge Cycles (80% of initial capacity) 4.7 Ounces NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof UL Rating UL Listed to UL508-4x specifications (File E194432) PAGE 4

Commercial Grade Sensors: Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burn-out. Corrosive gas or deoxidizing gas - chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc.). Volatile or flammable gas. Dusty conditions. Under low or high pressure. Wet or excessively humid locations. Places with salt water, oils chemical liquids or organic solvents. Where there are excessively strong vibrations. Other places where similar hazardous conditions exist. Use these product within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors - Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure: Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA rated enclosures. Our NEMA rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose directed water). Safe from falling dirt. Protects against wind blown dust. Protects against rain, sleet, snow, splashing water, and hose directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple South Salt Lake, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit, ALTA, PinchPower, Encrypt-RF and all other trademarks are property of Monnit, Corp. 2017 Monnit Corp. All Rights Reserved. ADS-A006-1B (04/17)