Test Report. Shenzhen Longsin Intelligence Technology Co.Ltd.

Similar documents
Test Report Garvan Enterprises Limited

COMITÉ EUROPÉEN DES ASSURANCES

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

ISO INTERNATIONAL STANDARD. Smoke alarms using scattered light, transmitted light or ionization

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

Consumer Products Services Germany GmbH Türkheim Germany

Loss Prevention Standard

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Page 2 of 14 Report Ref. No

This document is a preview generated by EVS

CNBOP-PIB Standard Fire Protection

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

HMN-D2 Insert Series

F-03 FIXED FIRE DETECTION AND FIRE ALARM SYSTEM

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

UL TEST REPORT AND PROCEDURE

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

Copy of marking plate:

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Safety of household and similar electrical appliances

Loss Prevention Standard

Audible warning devices for external alarm

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Safety of household and similar electrical appliances

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

HISTORICAL OF SAMPLE RECEIVED

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT ON THE SAFETY OF ELECTRICAL EQUIPMENT FOR PRODUCT INNOVATORS LTD ON A INFRARED TANKLESS HOT WATER SYSTEM

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

Fire Alarm Control Panel. System Maintenance and Log Book

Fire detection and fire alarm systems

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition

COMITÉ EUROPÉEN DES ASSURANCES

TEST REPORT IEC Safety of household and similar electrical appliances

TEST REPORT IEC/EN Safety of household and similar electrical appliances

Technical evaluation of the Ningbo Longmax Electronic Co., Ltd LM-201A battery operated carbon monoxide (CO) Detector Type B to EN :2010.

DRAFT MALAYSIAN STANDARD OFFICER/SUPPORT STAFF: (NA/ ) Descriptors: smoke, heat, control systems, power supplies

Environment Test Report

AS/NZS IEC :2013

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

See cover page See cover page

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TEST REPORT IEC Safety of household and similar electrical appliances

NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore Singapore

Rules for Classification and Construction Additional Rules and Guidelines

Guideline No.: S-02(201510) S-02 Navigation Light and Signal Light Controllers. Issued date: October 20,2015. China Classification Society

TEST REPORT IEC/EN Safety of household and similar electrical appliances Part 2: Particular requirements for portable heating tools

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Fire detection and fire alarm systems

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Vocia VACIE. Reference Guide

Fire detection and fire alarm systems

UL TEST REPORT AND PROCEDURE

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

ZH0505-GR-HT N/A IEC60335_2_9H LCIE

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

VACIE REFERENCE GUIDE REVISION 1.2.6

TEST REPORT EN Alarm Systems Intrusion and Hold-up Systems Part 2-4: Requirements for Combined Passive Infrared and Microwave Detectors

TEST REPORT XMT W/ATEX SHENZHEN CARY TECHNOLOGY CO,.LTD. LED Explosion Flood Luminaire

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

TEST REPORT EN Household and similar electrical appliances - Safety Part 1: General requirements

DESCRIPTION. 42 mm. 125 mm

TEST REPORT IEC60529 Edition TD990426C02

Oldal/ Page 2 / 2 Test report No.: Submersible Pump Test item description... :

User Manual. Non-contact Infrared Thermometer.

Tested by (name + signature)... : see on page 1. Approved by (name + signature)... : see on page 1. Tested by (name + signature)...

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

TEST REPORT IEC MEDICAL ELECTRICAL EQUIPMENT

Model No.: VS806-6N ( ) V~ 50/60Hz LED 6x4W

P R O D U C T D ATA S H E E T

Draft for Public Comment Australian Standard

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

TEST REPORT EN Household and similar electrical appliances. Safety. General requirements

SOUTH AFRICAN NATIONAL STANDARD

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

Transcription:

Test Report repared For : Shenzhen Longsin Intelligence Technology Co.Ltd. 4 th floor,building 2,Kaijeda Industrial Area,Huachang Road, Longhua Town,Baoan,Shenzhen. Trade Mark: Longsin roduct Name: Model : repared By : Smoke alarm LS-828-3, LS-828-4,LS-828-6,LS-828-7, LS-828-9,LS-828-10, LS-828-14AD Shenzhen HTT Technology Co., Ltd. 7F, Guangfu Building, Baoyuan Road, Xixiang, Baoan District, Shenzhen, Guangdong, China Test Date: Date of Report : Report No.: Jan.30,2015-Feb.04,2015 Feb.04,2015 HTT150104129LR-1 age 1 of 13

TEST REORT EN 14604:2005 Smoke alarm devices Testing Laboratory Name...: Shenzhen HTT Technology Co., Ltd. Address...: 7F, Guangfu Building, Baoyuan Road, Xixiang, Baoan District, Shenzhen, Guangdong, China Testing location...: Shenzhen HTT Technology Co., Ltd. Applicant's Name...: Shenzhen Longsin Intelligence Technology Co.Ltd. Address...: 4 th floor,building 2,Kaijeda Industrial Area,Huachang Road, Longhua Town,Baoan,Shenzhen. Manufacturer : Shenzhen Longsin Intelligence Technology Co.Ltd. Address : 4 th floor,building 2,Kaijeda Industrial Area,Huachang Road, Longhua Town,Baoan,Shenzhen. Standard...: EN 14604:2005 Test Result.: rocedure deviation...: N/A Non-standard test method...: N/A Compliance with EN14604:2005 Type of test object..: Smoke alarm Trademark. : Longsin Model/type reference.. LS-828-3 Rating.: DC9V Test item particulars : Equipment mobility : Operation condition : Class of equipment : rotection against ingress of water. Test case does not apply to the test object.. Test object does meet the requirement. Test object does not meet the requirement. fixed equipment Continuous Class III I20 N (.A.) (ass) F(ail) age 2 of 13

Name and address of the testing laboratory: Shenzhen HTT Technology Co., Ltd. 7F, Guangfu Building, Baoyuan Road, Xixiang, Baoan District, Shenzhen, Guangdong, China Test by : Feb.04,2015 Signature Date Review by : Feb.04,2015 Signature Date Approved by : Signature Feb.04,2015 Date age 3 of 13

General remarks: "(see remark #)" refers to a remark appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Attached with: A.Equipment list B.photo documentation Report No.: HTT150104129LR-1 Artwork of Marking Label Smoke alarm Model: LS-828-3 Rated: DC9V Shenzhen Longsin Intelligence Technology Co.Ltd. age 4 of 13

4 General requirements Report No.: HTT150104129LR-1 4.1 Compliance the smoke alarm shall meet the requirements of this clause 4.2 Individual alarm indicator (optional) LED indicator 4.3 Mains-on indicator Battery LED indicator 4.4 Connection of external ancillary devices No external ancillary devices N/A 4.5 Means of calibration 4.6 User replaceable components 4.6.1 Except for batteries or fuses, a smoke alarm shall have no user replaceable or serviceable components. 4.7 Normal power source The power source of the smoke alarm may be internal or external to the smoke alarm housing. 4.8 Standby power source 4.8.1 For smoke alarms intended for connection to an external power supply, for which an integral backup/standby power facility is provided, the following requirements shall apply: a) primary cell battery back-up: the back-up power supply shall be capable of meeting therequirements of 4.15; b) rechargeable back-up power sources: the backup power source shall be capable of supplyingthe quiescent load of the smoke alarm for a minimum period of 72 h followed by an alarm signalas specified in 5.17 for at least 4 min in the event of fire, or in the absence of a fire, a faultwarning for at least 24 h. Compliance Battery only There is no external power supply Ditto. 4.8.2 Monitoring of back-up power source N The back-up power source shall be monitored by the smoke alarm for faults. These faults shallinclude low back-up, open circuit and short circuit failure of the back-up (see 5.23). 4.9 Electrical safety requirements The apparatus shall be designed and constructed so as to present no danger, either in normal use or under fault conditions, as determined by the tests and requirements in 5.24. 4.10 Routine test facility 4.11 Terminals for external conductors N 4.12 Smoke alarm signals 4.13 Battery removal indication LED indication N N N N age 5 of 13

4.14 Battery connections Lead or terminal connections to batteries shall be identified with the proper polarity (plus or minus).the polarity may be indicated on the unit adjacent to the battery terminals or leads. 4.15 Battery capacity The batteries supplied with or specified for use in smoke alarms shall be capable of supplying the quiescent load of the smoke alarm together with the additional load resulting from a routine weekly10 s test, 4.16 rotection against the ingress of foreign bodies 4.17 4.17.1 The smoke alarm shall be so designed that a sphere of diameter (1,3 ± 0,05) mm cannot pass into the sensor chamber(s). Additional requirements for software controlled smoke alarms For smoke alarms, which rely on software control in order to fulfil the requirements of this document, the requirements of 4.17.2, 4.17.3 and 4.17.4 shall be met. 1.3mm 4.17.2 Software documentation 4.17.2.2 The manufacturer shall have available detailed design documentation, which only needs tobe provided if required by the testing authority. It shall comprise at least the following: 4.17.3 Software design In order to ensure the reliability of the smoke alarm, the following requirements for software designshall apply: a) the software shall have a modular structure; b) the design of the interfaces for manually and automatically generated data shall not permit invalid data to cause errors in the program operation; c) the software shall be designed to avoid the occurrence of deadlock of the program flow. 4.17.4 The storage of programs and data a mixture,the composition of which is described in table4 for 90min or until the alarm activates if less than 90min 4.18 Inter-connectable smoke alarms N 4.19 Marking and data 4.19.1 Smoke alarm marking a) the number and date of this document, age 6 of 13

b) the name or trade mark and address of the manufacturer or supplier; Report No.: HTT150104129LR-1 c) the date of manufacture, or the batch number; d) the manufacturer's recommended date for replacement, subject to normal, regular maintenance; e) smoke alarms incorporating user replaceable batteries: the type or numbers of batteries recommended by the manufacturer and an instruction to the user "Test the alarm for correct operation using the test facility, whenever the battery is replaced"; which shall be visible during the operation of changing the batteries; f) smoke alarms incorporating non-replaceable batteries: the warning "WARNING Battery not replaceable See instruction manual" which shall be visible during normal use. 4.19.2 ackaging marking The point-of-sale carton, in which a smoke alarm employing a radionuclide is packaged, shall bepermanently marked on the exterior with the trefoil symbol, name of radionuclide, and activity. 4.19.3 Data 5 Test Information supplied on or with smoke alarms shall include instructions on siting, installation and maintenance. 5.1.1 Atmospheric conditions for tests temperature :-10 C to 50 C; relative humidity : 95%RH air pressure:86 ka to 106 ka. 5.1.2 Operating conditions for tests The sample apparatus shall be prepared and mounted when applicable,in accordance with the manufacture 5.1.3 Mounting arrangements 5.1.4 Tolerances 5% 5.1.5 Measurement of response threshold value 5.1.6 rovision for tests 20 specimens; 5.1.7 Test schedule 5.2 Repeatability age 7 of 13

5.2.1 Test procedure The ratio of the response threshold values ymax:ymin or mmax:mmin shall be not greater than 1,6. 5.2.3 Requirements 5.3 Directional dependence 5.4 Initial sensitivity See attachment 3 5.5 Air movement 5.6 Dazzling 5.7 Dry heat To demonstrate the ability of the smoke alarm to function correctly at high ambient temperatures, which may occur for short periods in the service environment. 5.8 Cold (operational) To demonstrate the ability of the smoke alarm to function correctly at low ambient temperatures, which may occur for short periods in the service environment. N 5.9 Damp heat (operational) 5.10 Sulphur dioxide (SO2) corrosion To demonstrate the ability of the smoke alarm to withstand the corrosive effects of sulphur dioxide asan atmospheric pollutan The test apparatus and procedure shall be as described in EN 60068-2-42:2003, except that the conditioning shall be as described below. 5.10.2.2 State of the specimen during conditioning 5.10.2.3 Conditioning The following conditioning shall be applied: Temperature(25 ± 2) C; Relative humidity(93 ± 3) %; SO2 concentration(25 ± 5) ppm (by volume) i.e. (25 ± 5) x 10-6; Duration 4 days. 26ppm 5.11 Impact 1.9J (after tested the enclosure no damage) 5.12 Vibration (operational) N/A 5.13 Vibration (endurance) To demonstrate the ability of the smoke alarm to withstand the long term effects of vibration at levels appropriate to the shipping, installation and service environment. age 8 of 13

5.13.2.3 5.14 Final measurements Electromagnetic Compatibility (EMC), immunity tests (operational) Report No.: HTT150104129LR-1 After the conditioning the response threshold value shall be measured as described in 5.1.5. 5.15 Fire sensitivity m = 0,02 db m-1. 5.16 Battery fault warning smoke alarm will give an audible fault warning before an increase in the internal resistance or decrease in the terminal voltage of the battery prevents correct operation. 5.17 Sound output the smoke alarm is capable of providing an adequate sound output. 5.18 Sounder durability the smoke alarm's sounder to operate as intended after prolonged operation. 5.19 Inter-connectable smoke alarms 5.20 Alarm silence facility (optional) N 5.21 Variation in supply voltage 5.22 Battery reversal To demonstrate the ability of the smoke alarm to function properly after being misconnected with respect to polarity. 5.23 Back-up power source the back-up power source is correctly monitored. 5.24 Electrical safety assessment and testing to determine the adequacy ofpersonal protection against hazardous currents passing through the human body(electric shock), excessive temperature and the start and spread of fire 5.24.1 Marking Comply marked in accordance with EN 60065:2002, Clause 5 5.24.2 Heating under normal operating conditions Comply the requirements of EN 60065:2002, Clause 7. 5.24.3 Shock hazard under normal operating conditions Comply the requirements of EN 60065:2002 5.24.4 Insulation requirements Comply the requirements of EN 60065:2002 5.24.5 Fault conditions Comply the requirements of EN 60065:2002, Clause 11. 5.24.6 Mechanical strength Comply the requirements of EN 60065:2002 age 9 of 13

5.24.7 Clearances and creepage distances Comply the requirements of EN 60065:2002 5.24.8 Components Comply the requirements of EN 60065:2002 5.24.9 rotection against the start and spread of fire Ditto. 5.24.10 arts connected to the supply mains comply with the requirements of Clause 13 of EN 60065:2002 5.24.11 Wiring connections Comply with the requirements of 3.1, 3.2, 3.3 and 3.4 of EN 60950-1:20012. 5.24.12 Resistance to the effects of heat and fire age 10 of 13

ANNEX AA: Equipment list Code Name Model/Type S/N Calibrated date Next Calibration Date Manufacture HTT-001 Digital Multimeter 34401A MY47043456 2014.02.20 2015.02.19 agilent HTT -004 ush/pull gauge NK-500 2Q10060932 2014.02.20 2015.02.19 HTT -005 Electronic weight DSI-861 198692 2014.02.20 2015.02.19 shangdeli HTT -006 HTT -007 Insulation resistance tester Earthing resistance tester CS2676CX 1107032-009 2014.02.20 2015.02.19 changshen YD2668-4B 4B-2307 2014.02.20 2015.02.19 Yangzi HTT -008 HI-pot/Insulation tester CS2672C 1108006-002 2014.02.20 2015.02.19 changshen HTT -010 AC Voltage Regulator TDGC2J 2014.02.20 2015.02.19 SAKO HTT -013 AC power source HA-3110 3513 2014.02.20 2015.02.19 Henqiang HTT -014 Temperature/Hum idity chamber SDJ-80L SDJ-80J 2014.02.20 2015.02.19 HTT -015 Electric oven HK45AS F11011008 2014.02.20 2015.02.19 HTT -017 AC digital power meter F9901 HTT -019 DC electronic load IT8512 HTT -022 Leakage current tester YG100731N110 70075 0020025066700 01002 Shenzhen hongjian KENTON 2014.02.20 2015.02.19 Yuanfang 2014.02.20 2015.02.19 ITECH 228 10-866030 2014.02.20 2015.02.19 simpson HTT -023 Oscilloscope TDS1012C-SC C013300 2014.02.21 2015.02.20 tektronix HTT -024 Tape measure DK-2041 2014.02.23 2015.02.22 roskit HTT -025 Stop watch TA-228 2014.02.21 2015.02.20 KTJ HTT -026 Data acquisition/switch unit 34970A MY44057668 2014.02.24 2015.02.23 Agilent HTT -027 Temperature/humi dity meter VC230 2014.02.21 2015.02.20 ViCTOR HTT -028 Torque drive 3RTD 435850B 2014.05.15 2015.05.14 TOHNICHI HTT -030 Impact hammer ZLT-CJ1 C011207 2014.02.21 2015.02.20 HTT -031 Inclined plane ZLT-WD1 W011201 2014.02.20 2015.02.19 HTT -033 Test finger ZLT-I02 I021203 2014.02.23 2015.02.22 HTT -034 Test pin ZLT-I09 I091201 2014.02.23 2015.02.22 zhilitong zhilitong zhilitong zhilitong HTT -038 Test apparatus of the mains plug ZLT-LJ2 LJ011202 2014.02.20 2015.02.19 zhilitong HTT -039 Ball pressure apparatus ZLT-QY1 Q011202 2014.02.21 2015.02.20 zhilitong HTT -042 Caliper rule CD-6"CSX 500-196-20 2014.07.05 2015.07.04 MITUTOYO age 11 of 13

ANNEX BB: hoto-documentation hoto 1: front view hoto 2: back view age 12 of 13

hoto 3: internal view ***END OF REORT*** age 13 of 13