Greentrol Automation, Inc.

Similar documents
Power Supply Display Module PSDM. Installation and Operation Manual

Model 4880 Status Output Display Module Manual

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Public Safety DAS Annunciator Panel

Pioneer-R16 Gas Monitor Operator s Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Duct and Rough Service Carbon Monoxide Sensor

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

Instruction Manual WARNING

ACCURATE ELECTRONICS INC

Controllers. Instruction Manual WARNING

Model 4001 Series Single Channel Controller

Mark 25 Ultrapure Water Conductivity Analyzer

Carbon Monoxide Transmitter

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

NT DUAL CHANNEL DISPLAY. User Guide

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

MBCE-110/230UV Flame Sensor Module

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Installation, Operation & Service Manual

Sierra Series 900 Single & Dual Channel System. Instruction Manual

AC/DC Power Supply and Battery Charger Installation and Maintenance

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

4100U City and Relay Cards Installation Instructions

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Beacon 410A Gas Monitor Operator s Manual

/ XPS Interconnection Diagrams

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

* These Remote Mics must be SPRM-GP

Installation Instructions

ISIMET Series Shop Controller

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Battery charger modules

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SAFETY INFORMATION AND WARNINGS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

LC2200 Level Controller Installation and Maintenance Instructions

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

RAM3 Remote Alarm Module

SCHMIDT LED Measured Value Display MD Instructions for Use

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

T3/E3 Fiber Optic Line Drivers

BRG-N100 BACnet Objects. BRG-N100 Modbus Register Map

Operating Instructions. For. Alarm Control Module. Model SSR 500

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Series. Access Power Controllers. Installation Guide

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

RCS Residential Control Systems Inc.

Booster Power Supply Manual

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Analog Room Pressure Monitor RPC Series

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Installation Guide for models:

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

CU-02 with Senaco Plus

ISIMET Utility Controller

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

CP CP

RELEASE DEVICE CONTROLS

FLT93 Installation, Operation and Troubleshooting Guide

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

4 Channel Contact Closure SFP DIN Fiber Link System

Set-Up Procedures. Before You Start

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

INSTALLATION INSTRUCTIONS

Instruction Manual August sitrans CU 02

Model OEM-2 INSTRUCTIONS FOR USE

Sensor Interface Module Installation/Operation Instructions

Proliphix Thermostat Installation Guide. Release 2.0

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

D454.F.CE Product Guide

Two-Channel Gas Controller

Water Source Heat Pump Module Technical Guide

Pump-Up Controller MODEL 4062

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

Oxygen (O2) Single-Point Gas Detection System

Q7800H Integrated Burner Control Subpanel

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Installation Guide for models:

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Transcription:

Model GA-100 Technical Manual GreenAlert 100 Series Greentrol Automation, Inc. Installation, Operation and Maintenance Technical Manual GA-100 Document Name: TM_GA-100_R1C TM_GA-100_R1C Part Number: 960--0000

LIST OF EFFECTIVE AND CHANGED PAGES Insert latest changed pages (in bold text); remove and dispose of superseded pages. Total number of pages in this manual is 10. Page No Revision * Description of Change Date 1-4; 9........R1C..........Removed OEM references; updated to R1C..................11/23/2011 8.............R1B..........Corrected location of LED PWR jumper.......................08/02/2010 1 through 10...R1A........Initial document release...................................06/24/2010 TM_GA-100_R1C 2

Table of Contents SPECIFICATIONS.........................................................................................4 OVERVIEW..............................................................................................4 GA-100 FEATURES.......................................................................................4 GA-100 INSTALLATION....................................................................................5 POWER TRANSFORMER CONSIDERATIONS...............................................................5 GA-100 WIRING.....................................................................................5 TB2 - POWER CONNECTIONS..........................................................................6 ANALOG INPUT CONNECTIONS.........................................................................6 GA-100 MECHANICAL DETAIL..............................................................................6 Selecting the analog input type (voltage or current) using the 4-20mA Jumper.............................7 OPTIONAL ALARM OUTPUT CONNECTIONS...............................................................7 Selecting the optional Alarm output type using the LED PWR Jumper.....................................7 GA-100 START UP........................................................................................7 General............................................................................................7 MAINTENANCE..........................................................................................7 GREENTROL STANDARD LIMITED PARTS WARRANTY...........................................................9 List of Figures Figure 1. GA-100 Analog Alarm Device......................................................................4 Figure 2. GA-100 Features................................................................................5 Figure 3. GA-100 Mechanical Detail Drawing.................................................................6 Figure 4. GA-100 Main Circuit Board Detail..................................................................8 Figure 5. GA-100 Wiring Diagram Detail.....................................................................8 List of Tables Table 1. GA-100 Troubleshooting...........................................................................9 TM_GA-100_R1C Copyright 2010 - All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. All rights reserved. 3

OVERVIEW GreenTrol model GA-100 is a high quality, economical alarm solution designed for installation in critical applications where alarm features are necessary. The GA-100 can be configured to accept 0-10VDC, 0-5VDC or 4-20 ma signals. Local alarm status is provided by a front panel indicator. The remote alarm output can be set up as dry relay contacts (normally open, close on alarm, rated 30VDC/24VAC @ 3amperes maximum) or as an external LED driver (15mA typical). The alarm threshold is fixed at 3.0VDC (0-5/0-10VDC inputs), or 6mA (4-20mA input). The GA-100 analog input interface allows an alarm feature to be added to virtually any analog output device that is not alarm capable. The GA-100 processes the raw analog signal and provides versatile alarm options for local LED, remote LED drive, and normally open relay dry contacts. Figure 1. GA-100 Analog Alarm Device SPECIFICATIONS System Alarm Modes: Local Alarm: Remote Alarm Output: Operating Temperature: Operating Humidity: Power Requirements: Local and remote analog alarm active when alarm threshold is exceeded Front panel Alarm indicator N.O. Dry Relay Contacts -20 to 120 F [-28.9 to 48.9 C] 0 to 99% non-condensing; Instrument must be protected from exposure to precipitation 22.8-26.4VAC, 2VA maximum Input/Output Interface Analog Input: Alarm Threshold: Alarm Types: Wiring Interface: Selectable 0-10VDC, 0-5VDC or 4-20mA Active alarm when analog input is greater than 3.0 VDC / 6.0mA 1. N.O. relay contacts, 30VDC/24VAC @ 3amps max. or as direct LED drive (15 ma typ) 2. Front panel red LED indicator indicating alarm activity Rugged insulated plug-in terminal blocks for simple field wiring Power Supply Power Supply: Enclosure Enclosure Material: Enclosure Rating: Enclosure Dimensions: Mounting: Internal high efficiency switching power supply with integral short circuit and thermal overload protection Durable electronic housing with removable cover UL94-5VA 3.355 x 3.355 x 1.357 in (HxWxD) [85.22 x 85.22 x 34.47 mm], with two integral 0.4475 [11.37 mm] mounting flanges. Overall width with flanges 4.25 [107.95 mm] Two 0.190 in [4.83 mm] diameter holes on left/right mounting flanges TM_GA-100_R1C Warranty 12 months from shipment. 4

GA-100 FEATURES UL94-5VA rated enclosure with integral mounting tabs LED Alarm Indicator Rugged insulating terminal blocks with removable wiring connectors Removable cover for access to simple field-configuration jumpers Local and remote alarms via relay dry contacts or direct drive for external alarm LED. GA-100 INSTALLATION Figure 2. GA-100 Features The GA-100 is designed for use in an environment between -20 F to 120 F (-28.8 C to 48.8 C) where it will not be exposed to precipitation. A NEMA-4 enclosure must be provided to protect the GA-100 in locations where precipitation may be encountered. The GA-100 must be installed in a field accessible location with sufficient service clearance to permit cover removal. The enclosure accepts signal and power wiring at the bottom of the enclosure. Ensure that the planned location will allow the signal and power wiring to reach the wiring terminal blocks at the bottom of the GA-100 enclosure. CAUTION In locations exposed to precipitation, the GA-100 must be enclosed in a NEMA4 enclosure. Provide sufficient clearance around the GA-100 to permit cover removal. Locate the GA-100 in a location that can be reached by the connecting signal and power cables. Do not drill into the GA-100 enclosure since doing so may damage the electronics. TM_GA-100_R1A 1. Carefully unpack the GA-100 and inspect for damage. If damage is noted, immediately file a claim with carrier. 2. Using the engineer s plans, locate where the GA-100 will be installed. 3. Remove the two wiring connectors from the GA-100 terminal blocks and mark the two mounting holes located on each of the enclosure side flanges as shown in Figure 3. 4. Drill two holes suitable for the hardware that will be used to secure the GA-100. 5. Secure the GA-100 in two places using suitable hardware. 6. Using the wiring connectors that were removed in step 3, connect signal and power cabling to the GA-100 wiring connectors as outlined in the following GA-100 WIRING procedure. POWER TRANSFORMER CONSIDERATIONS Select a 24 VAC transformer based on the maximum power requirements of the GA-100 (3.5 VA) to ensure that the operating supply voltage to the GA-100 (when powered ON ) is not less than 22.8 VAC or greater than 26.4 VAC. 5

GA-100 MECHANICAL DETAIL C L 3.355 AT BASE (TAPERS TO 3.295 AT COVER) REMOVABLE COVER O 0.156 O 0.190 (2 PLCS) REMOVABLE COVER 1.357 1.250 3.295 0.784 0.438 1.6775 AT BASE 0 0.9875 1.6775 1.9125 1.7875 2.5125 3.355 0 0.4475 3.355 AT BASE TAPERS TO 3.295 AT COVER LEFT SIDE VIEW DETAIL 3.8025 4.25 AT BASE FRONT VIEW DETAIL 6 GA-100 WIRING Figure 3. GA-100 Mechanical Detail Drawing GA-100 wiring consists of connecting 24VAC input power and the optional alarm output at the GA-100. Refer to Figures 4 and 5 for additional detail. Following installation, review the GA-100 START UP Procedure. Wiring connections to the GA-100 are accomplished at three removable screw-type terminal block connectors for TB1 and TB2 at the left side of the instrument as shown in Figure 4. The connectors are keyed to prevent improper hookup to the instrument. TB2 - POWER CONNECTIONS 1. Remove 2 terminal wiring connector TB2. 2. Connect 24 VAC power to TB2 terminal 1, and the 24V ground to TB2 terminal 2 as shown in Figures 4 and 5, observing the following wiring precautions. CAUTION To prevent damage to the GA-100, deactivate 24 VAC power source until all connections to the instrument are complete. The 24 VAC input ground (GND) connection at TB2 terminal 2 is shared with the analog input signal ground at TB1 terminal 2. If isolation is required, a dedicated isolation transformer must be provided to power the GA-100. The GA-100 is a non-isolated device with a half-wave rectifier on the 24VAC power input terminal at TB2-1. Therefore, to prevent equipment damage, multiple devices that are powered by a common 24VAC transformer with the GA-100 must use common device power connections (e.g. TB2-1 24VAC input power to other device power inputs, and TB2-2 ground to other device grounds), or independent isolation transformers must be provided for each non-isolated device. The GA-100 24VAC ground and analog input signal returns are common. Therefore it is recommended that the analog input be connected using TWO separate twisted shielded pairs in order to eliminate potential voltage drop on the common (from the 24VAC return) that would otherwise cause inaccurate readings. To prevent any potential water runoff into the GA-100, form drip loops with interconnecting wires to the GA-100. Check the physical installation, power connections and wiring prior to application of power to the instrument. TM_GA-100_R1A

ANALOG INPUT CONNECTIONS The GA-100 accepts an analog input signal of 0-10VDC, 0-5VDC or 4-20mA. The 24VAC return ground connection is shared with the analog input signal ground (GND). If the analog input must be isolated from the 24VAC return, a dedicated isolation transformer must be provided to power the GA-100. 1. Remove the 4 terminal wiring connector TB1. 2. Connect the analog input signal wire at TB1-1, and the signal ground at TB1-2 as shown in Figures 4 and 5 while observing the previous wiring precautions. Selecting the analog input type (voltage or current) using the 4-20mA Jumper 1. Remove the four cover retaining screws at each corner of the transmitter cover in order to gain access to the transmitter Wiring Terminal Block on the main circuit board shown in Figure 4. 2. Remove cover from the enclosure. 3a. For 0-5VDC and 0-10VDC analog input, remove the jumper across the 4-20mA terminals (or place it on only one of the two pins); OR 3b. For 4-20mA analog input, install the jumper across the 4-20mA terminals. OPTIONAL ALARM OUTPUT CONNECTIONS In addition to the front panel LED alarm indicator, the GA-100 can be configured to provide an alarm output as relay dry contacts, or as direct drive (15 ma typical) for an external LED indicator. The alarm output type is set using the LED PWR jumper on the GA-100 main circuit board as shown in Figure 4. With the LED PWR jumper on, the alarm output is set to produce LED drive (15 ma typical) to an external LED at TB1 terminal 4, with the LED cathode return at TB2-2. With the LED PWR jumper OFF, the alarm output is configured as dry relay contacts (normally open) to close on alarm between TB1-3 and TB1-4. Contacts are rated at 30VDC/24VAC 3 amps maximum. Selecting the optional Alarm output type using the LED PWR Jumper 1. Remove the four cover retaining screws at each corner of the transmitter cover in order to gain access to the transmitter Wiring Terminal Block on the main circuit board shown in Figure 4. 2. Remove cover from the enclosure. 3a. For external LED drive alarm output, install LED PWR jumper, and connect LED anode (+) to TB1 terminal 4, and cathode (-) at Power Connector TB2 terminal 2. OR 3b. For relay dry contact alarm output, remove the jumper across the LED PWR terminals (or place it on only one of the two pins), and connect the alarm wires to TB1 terminals 3 and 4. Contact rating is 30VDC/24VAC at 3 amps maximum. TM_GA-100_R1A GA-100 START UP General To ensure successful start-up, verify that the GA-100 has been installed and wired in accordance with the previous installation and network setup instructions. Upon application of 24VAC power, the GA-100 is ready for normal operation. Verify initial operation as follows: 1. Activate 24VAC power to the GA-100. 2. Verify that with an analog input of greater than 3.0VDC or 6mA, the front panel alarm LED (and remote alarm output) is activated. If alarm is not active, remove power to the GA-100 and re-check all wiring connections. 3. Verify that with an analog input of less than 3.0VDC or 6mA, that the front panel alarm LED (and remote alarm output) remain inactive (LED is OFF). If alarm is active, remove power to the GA-100 and re-check all wiring connections to the device. 4. The GA-100 is now ready for normal operation. 7

4-20mA JUMPER ON = 4-20mA Analog Input OFF = 0-10/0-5/2-10VDC Analog Input LED PWR JUMPER ON = External LED Alarm Output OFF = Relay Dry Contacts TB1 Analog Input/ Alarm Output Removable Terminal Block Wiring Connectors TB1 1 2 3 4 4-20mA +VDC AIN GND COM. RLY N.O. LED PWR D3 ALARM TB2 1 24VAC TB2 24VAC INPUT 2 GND 1 AMP Alarm LED Indicator F2 Fuse - Power Replace only with UL listed, 1.0A-2AG Fast Acting P.N. 240-1229 Figure 4. GA-100 Main Circuit Board Detail ANALOG OUTPUT DEVICE + ANALOG OUTPUT SIGNAL (TO TB1-1) ANALOG SIGNAL TO BE MONITORED - ANALOG OUT COM GROUND (TO TB1-2 SEE NOTES 2, 3) TB1 1 2 GA-100 ALARM UNIT LED PWR JUMPER RELAY ALARM CONTACTS (LED PWR JUMPER OFF ) COM RELAY DRY CONTACTS 30VDC/24VAC @ 3 AMPS MAX) DRY ALARM RELAY COMMON (ONLY WHEN LED PWR JUMPER IS REMOVED) ALARM RELAY DRY CONTACT (ONLY WHEN LED PWR JUMPER IS REMOVED) 3 4 TB2 1 2 LED PWR TB1 JUMPER REMOVED 1 ANALOG INPUT SIG 2 ANALOG GROUND 3 ALARM RELAY COM 4 ALARM RELAY DRY CONTACT TB2 1 24VAC POWER IN 2 24V GROUND LED PWR TB1 JUMPER INSTALLED 1 ANALOG INPUT SIG 2 ANALOG GROUND 3 NO CONNECTION 4 ALARM LED (+15mA) EXTERNAL LED ALARM INDICATOR (LED PWR JUMPER ON ) ALARM LED SIGNAL (ONLY WHEN LED PWR JUMPER IS ON) EXTERNAL ALARM LED (15 ma) ILLUMINATES ON ALARM ALARM LED GROUND (ONLY WHEN LED PWR JUMPER IS ON) NOTES: 1. CONNECT ANALOG SIGNAL CABLE DRAINS TO EARTH GROUND AT ONE END OF CABLE ONLY. TRANSFORMER 24 VAC / 50-60 HZ (SEE NOTES 2 AND 3) LINE IN 24 VAC OUT 24VAC GROUND 2. THE GA-100 IS A NON-ISOLATED DEVICE USING A HALF-WAVE RECTIFIER ON THE 24VAC POWER INPUT. IF MULTIPLE DEVICES ARE POWERED BY THE SAME TRANSFORMER OUTPUT, ALL GND CONNECTIONS MUST BE COMMON, OR AN ISOLATION TRANSFORMER MAY BE USED TO PREVENT EQUIPMENT DAMAGE. 3. ALL DEVICES ON MULTIPLE GA-100 INSTALLATIONS WITH A COMMON 24VAC SOURCE MUST BE WIRED IN- PHASE TO THE SAME TERMINALS (e.g.: TB2-1 to TB2-1, TB2-2 to TB2-2). 4. SHIELDED TWISTED PAIR (STP) WIRING IS RECOMMENDED (SUPPLIED BY OTHERS). TM_GA-100_R1B 8 Figure 5. GA-100 Wiring Diagram Detail 8

MAINTENANCE When the GA-100 is installed in accordance with recommended guidelines, instrument difficulties are rare. Issues can be easily resolved by proceeding through the troubleshooting guide of Table 1. Problem Possible Cause Remedy No Alarm output when analog input is greater than 3VDC (or 6mA when using 4-20mA input). Alarm output is active when analog input is less than 3VDC (or 6mA when using 4-20mA input). Table 1. GA-100 Troubleshooting Power is not available at GA-100. Improper supply voltage to the power input terminal block. Blown fuse. GA-100 internal malfunction.. Apply 24VAC power to the GA-100. Ensure that 24VAC power is available at TB2 terminal 1 and ground at terminal TB2-2, and that the voltage with power applied to the GA-100 is between 22.8 and 26.4 VAC. Check power wiring. Ensure that multiple devices wired on a single transformer are wired "in-phase". Replace fuse only with a 1.0 amp, fast-acting fuse after the problem has been identified and corrected. Check all cable connections. If connections are OK contact customer service for further assistance. No analog signal is measured at the GA-100 analog input TB1 terminal 1 (signal +) and terminal 2 (signal ground/return). Improper input wiring. Verify that 24VAC power is connected at TB2 pin 1, and ground at pin 2. Verify that all other non-isolated devices that are powered from the same 24VAC power source are correctly wired in-phase (24V power to 24VAC power and ground to ground). The power input of the GA-100 is a half wave rectifier, and requires that all common devices be wired with common power and ground connections. The analog input signal (TB1-1 and TB1-2) fluctuates while the device being monitored indicates no change. Electrical interference from other devices is creating noise in the analog signal wires. The input signal wiring must be shielded. Individually ground one or more of the following points: the signal wire shield at the host device; the signal wire shield at the GA-100, or the power input ground at TB2 terminal 2 of the GA-100. The Alarm does not occur when expected. The output from the host device system is incorrect. Check the analog output from the host device being monitored. GA-100 Alarm output is active whenever the monitored analog signal is greater than 3VDC (or 6mA when 4-20mA input is selected). GREENTROL STANDARD LIMITED PARTS WARRANTY Greentrol products are warranted for 12 months from shipment. Product will be repaired/replaced free of charge as described in the Terms and Conditions of Sale. TM_GA-100_R1C 9

TM_GA-100_R1A Automation, Inc.