Systemfilter Operation manual GB

Similar documents
MODEL NO. UNIT PRICE FOB SIZE UV A 1/2GPM (6 WATT)

gamma pond Ultraviolet Sterilizers

UV I UNIT030W / UV I UNIT055W

WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

BioMaster 250/350/600 BioMaster Thermo 250/350/600

Warning! Buyer/user assumes all responsibility for safety and proper use not in accordance with the directions and safety labels.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AEM EASY DRUM M A N U A L

100 Series Maxi Internal Filters

AquaReef Cube. Inspiring Excellence in Fish Keeping!

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

INSTALLATION AND INSTRUCTION MANUAL IMPORTANT PLEASE READ:

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

Installation and Operating Instructions

GARDENA. F 3000 Art F 6000 Art F 9000 Art F Art. 7929

MIGHTY PRO 1/4 HP CHILLER

System 2500/5000 Filtration Unit (Marine) Installation, Operation and Maintenance Instructions

ARTICEL 51627/51628/51629/51630/51631/51632/51633

Manual of RDF-Rotatory Drum Filter

PondoPress 10000, 15000

Protein Skimmer 400 HO

Hand Held Steamer DF-A001 User Manual

WARNING: Ensure that the unit is switched off at the mains before you attempt to conduct any type of maintenance on the evouv.

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Aqua Ultraviolet UV Sterilizer Instruction Manual for SL Series Wiper Units

1,500 2,500 4,500 9,000 14,000 20,000 30,000 50,000 1,000 1,000 2,000 3,000 4,000 8,000 12,000 18,000 N/A PF2500 (NO UVC)

UV Biological Pond Filter. Inlet /Outlet Size

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

Pressurized Filter Up to 1250 gallons

Operation Manual ARTICEL

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Prime Chiller 1/10th HP Chiller

KOI Professional Pond Filter

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

Prime Chiller Mini-Chillers

AQUARIUM HEATER RANGE AH-25 / AH-50 AH-100 / AH-200 AH-300

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

AllClear G2 Series Pressurized Filters Product Manual

Minima User Guide and Installation Manual

EASYCLEAR 3000 YEAR GUARANTEE

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

EasyClear 3000/ YEAR GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

SK-200. Up to 80 gallons Aquarium. Optional with UV-5W Sterilizer. Refrigerate medium

NEW. The automatic choice for your pond

Ultraviolet (UV) Water Treatment System

6000/7500/ YEAR GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

HOT WASHER MODEL NO: KING150

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

SimplyClear Pressurized Filter Product Manual

PRESSURIZED POND FILTER

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

Installation and Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS. WARNING To guard against injury, basic safety precautions USA

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

ANTIBACTERIAL HAND VAC WITH UV LIGHT

nova extreme retrofit High Output T5 Lighting Kit

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

INSTALLATION AND INSTRUCTION MANUAL

Prime Chiller Modular Upgradable Chiller

PERSONAL Ultrasonic Cool Mist Humidifier

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Installation & Maintenance Guide

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

Rechargeable UV-A LED/Emergency Light

AQUA LOGIC S CORONA SERIES UV STERILIZERS

Electronic 30 Watt UV-A Lamp Indoor

SOOTHING COOL MIST AROMA DIFFUSER

User manual UV Flash Dry C1

COR-20 STANDALONE MAIN TITLE GOES MODE USER GUIDE HERE

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

I N S T R U C T I O N S

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

INSTALLATION AND OPERATING MANUAL. Complete instructions for all models of evouv WARNING:

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

UV-C Sanitizing System USER MANUAL Purifying Wand (EPLPW)

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

HX-30/40 and HX-30/40 S Glass and Dishwashers

BioZone Scientific International contact information

ADORABLE Ultrasonic Cool Mist Humidifier

SUN EQUINOX HEATING SYSTEMS

American Dish Service

FC 5 FC 5 Premium. OPERATOR MANUAL Floor Cleaner...2 MANUAL DE USUARIO Limpiador de piso...22 MANUEL D UTILISATION Nettoyant pour sols...

HKF 8180 Operating instructions

Modular Grease Trap MGTA

Ocellaris 3000 / 3000UV

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Installation, Operating and Servicing Instructions

AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC

2-IN-1 Warm Mist Humidifier with Steam Inhaler

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Solar Cascade Solar Duo Cascade Solar Fish

Pressurefilter CPF-Series

26/06/2018 USER MANUAL HOBBY 100 GPH REVERSE OSMOSIS. All Rights reserved Les Équipements d Érablière CDL inc.

Transcription:

Systemfilter 10000 Operation manual GB The systemfilter 10000 has been developed for professional aquarium and aquaculture systems. The maximum recommended water volume depends on the bioload. For display aquarium systems, we recommend max. 10,000 litres. AB Aqua Medic GmbH Gewerbepark 24, 49143 Bissendorf, Germany

1. Features The Systemfilter 10000 is a modular system, delivered ready to use on a plastic pallet. It comprises the following components: - protein skimmer Turboflotor 10.000 with venturi pump (OK71) - pressurized sand filter as final mechanic filter with back-flush valve - trickle filter towers with Bactoballs for biological treatment - removable sponge filter for mechanic pretreatment - filter sump, plastic tank mounted on a plastic pallet, 120 x 80 cm - UV-sterilizer 2 x 55 Watts - connection for top up system - circulation pump, 15 m 3 /h, Type OK 71 2. Description The water supply to the filter is realized via gravity. For this reason, the filter has to be placed below the aquarium or tank. The diameter for the inlet pipes is D 90/D 75. The maximum water level in the filter sump is marked by an overflow (to waste). From the aquarium, the water flows by gravity into the filter sump and passes first the sponge filter and is collected in the clear water chamber. From there, it is sucked in by the recirculation pump and divided by a T-diverter into 2 directions. One part, the volume is adjustable with a ball valve and can be controlled by a flow meter, is diverted to the three trickle towers and flows back into the filter sump. All the rest is pumped through the sandfilter, the heater and the UV sterilizer back into the aquarium. The waste water connection of the pressurized sand filter via a three way valve to the drain. The refill (top up system) is a hose connection for a 1 (25 mm) hose. Here, tap water can be connected and an automatic water change can be controlled by a solenoid valve and a time switch. So, evaporated water is replaced as well as an automatic partly water change. Surplus water is drained through the overflow. 2

Set up Set up of the filter Unpack the filter and components: 1. Foam cup 2. Filter sump 3. Biotower for BactoBalls 4. Protein skimmer 5. Flow meter for air 6. Venturi pump for skimmer 7. Pressurized sand filter 8. UV-C sterilizer (2 pcs.) 9. Piping with venturi for air intake 10. Return pump Foam cup is mounted Pressurized sandfilter with valve 3

Detail: Piping in the sump, suction side of pump Detail: Plumbing of the pumps: 1. venturi pump for skimmer 2. circulation pump Plumbing of the Bactoballs tower Plumbing and mounting of the UV-sterilizer 4

Sponge filter inside the sump Cover the sponge filter after installation Biotower: fill the Biotower with Bactoballs. 3. Starting the filter - Please follow the instructions of the components (sand filter, circulation pump, UV-sterilizers). Fill the sandfilter with the recommended filter sand and switch the valve to filter. Fill the aquarium of tank as well as the filter sump with water and check all connections to be tight. Turn the ball valves but close the valves for the trickle filter and the drain. The 3-way valve has to be adjusted to drain. Start the pump. If there is water missing, refill it manually immediately. Open the valve to the trickle filters and adjust it to a max. flow rate of 6,000 l/h. Leave the water flow for min. 45 minutes on before you start the heater and the UV-sterilizer. 4. Operation The prefilter sponge has to be controlled on a regular base and cleaned, if necessary. The pressure of the sand filter has to be checked daily and if it rises (normal operation is 0.5 bar), the filter has to be backflushed. If the backflushing is done only irregulary, the filter may be blocked after some time so it is impossible to flush it back. It has to be openend then and cleaned by hand or even changed completely. Before backflushing, the 3-way-valve has to be set to backflush and afterwards back to overflow. The circulation pump has to be cleaned in regular intervals as well. Close the valve before the pump is opened. 5

5. Warranty Should any defect in material or workmanship be found within twelve months of the date of purchase AB Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of charge always provided the product has been installed correctly, is used for the purpose that was intended by us, is used in accordance with the operating instructions and is returned to us carriage paid. The warranty term is not applicable on the all consumable products. Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer s name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty may not apply if any model or production number has been altered, deleted or removed, unauthorised persons or organisations have executed repairs, modifications or alterations, or damage is caused by accident, misuse or neglect. We regret we are unable to accept any liability for any consequential loss. Please note that the product is not defective under the terms of this warranty where the product, or any of its component parts, was not originally designed and / or manufactured for the market in which it is used. These statements do not affect your statutory rights as a customer. If your AB Aqua Medic GmbH product does not appear to be working correctly or appears to be defective please contact your dealer in the first instance. Before calling your dealer please ensure you have read and understood the operating instructions. If you have any questions your dealer cannot answer please contact us. Our policy is one of continual technical improvement and we reserve the right to modify and adjust the specification of our products without prior notification. Attachments: AB Aqua Medic GmbH - Gewerbepark 24-49143 Bissendorf/Germany - Technical changes reserved 07/2011 - installation of the UV-sterilizer - installation of the pressurized sand filter 6

Helix Max Operation manual GB UV sterilizer for salt water and fresh water aquaria and garden ponds This UV sterilizer is a quality unit. If used correctly, Helix Max kills microalgae and creates cristal clear water in aquariums and garden ponds. It inactivates bacteria and other parasites and the risk for infection of the fish decreases. It has been specifically developed for aquarium use, has been designed and manufactured to the highest standards and has been extensively tested. AB Aqua Medic GmbH Gewerbepark 24, 49143 Bissendorf, Germany 7

1. Operating principle The UV sterilizer Helix Max clears the water with the help of ultraviolet radiation. This radiation is emitted by a special lamp. The UV-C radiation kills all forms of life that is directly exposed to the radiation microalgae, bacteria, protozoa and other parasites. The result is cristal clear water and healthy fish. 2. Special features Spiral water flow: The unique spiral water flow and the big volume of the Helix Max units ensure an optimum water clarification. The water is directed in a spiral way around the quartz tube with a long contact time. Due to this, the UV-radiation is used with maximum efficiency. Rotable connections: The inlet and outlet connections of the Helix Max can be rotated by 360. This saves space and fascilitates the installation. 3. Sizes/technical data Helix Max sterilizers are produced in 6 sizes: 5 watts, 9 watts and 11 watts with 2 m cable for fresh and saltwater aquaria. 18 watts, 36 watts and 55 watts, with 10 m rubber cable and electronic ballast for garden ponds and for fresh and saltwater aquariums. A higher UV output and a longer life span of the UV lamps are ensured by the electronic ballasts. For the different applications, we recommend different aquarium/pond sizes and flow rates. In garden ponds, the recommended flow rates will not result in a sterilization, but the water is clarified by killing the microalgae. Helix Max Saltwater Recommended Freshwater Recommended Pond Max. type aquarium max. flow aquarium max. flow flow 5 watts 25 125 l 100 l/h 50 250 l 200 l/h - 9 watts 125 250 l 200 l/h 250 500 l 500 l/h - 11 watts 150 350 l 300 l/h 350 750 l 700 l/h - 18 watts 250 500 l 500 l/h 500 1,000 l 1,000 l/h 18,000 l 6,000 l/h 36 watts 500 1,000 l 1,000 l/h 1,000 2,000 l 2,000 l/h 36,000 l 12,00 0 l/h 55 watts up to 1,500 l 1,500 l/h up to 3,000 l 3,000 l/h 55,000 l 18,00 0 l/h Helix Max type Cable length Lamp type Max. Protection Power connection (m) pressure 5 watts 2 m PL-S-5 watts 0,3 bar IPX3 230 V~/50 Hz 9 watts 2 m PL-S-9 watts 0,3 bar IPX3 230 V~/50 Hz 11 watts 2 m PL-S-11 watts 0,3 bar IPX3 230 V~ /50 Hz 18 watts 10 m PL-L-18 watts 0,3 bar IPX3 230 V~/50 Hz 36 watts 10 m PL-L-36 watts 0,3 bar IPX3 230 V~/50 Hz 55 watts 10 m PL-L-55 watts 0,3 bar IPX3 230 V~/50 Hz 4. Safety advice The radiation of the UV-C lamps is dangerous. Direct contact with eyes or skin can result in irreversible damages. Therefore, the unit must always be switched off before it is opened. The units Helix Max 5, 9 and 11 watts are suitable for indoor use only. The units may only be switched on when the water flow is on. If used on a garden pond, the units have to be switched off and removed during winter to prevent damages from frost. The units may not be submerged or operated under water. 8

5. Connection The Helix Max are supplied with transparent connection pieces. This allows to control the function of the bulbs there is a blue light when the UV bulbs are on. Depending on the installed pump and water flow, the connection pieces can be cut to the best size (metal saw). The connections of the Helix Max can be rotated for 360. This allows an easy adaptation to the mounting conditions. In any case, the units have to be set up in a way that the outlet is at the highest point to avoid air to be trapped in the unit. 1. Housing 2. Ballast 3. UV-C Lamp 4. Connection pieces 5. Holding plate 6. Maintenance and cleaning 1. The UV-C lamps have a life span of approx. 8,000 hrs. After 5,000 hrs, the UV-C output of the lamps decreases to 85%. The lamps have to be changed regularly. We recommend to clean the quartz tube whenever the lamps are changed. 2. Switch the power off, stop the water flow and drain the water from the unit (dismount the water connections). 3. Open the large screw cap. Careful: The lamp is fixed with the socket in the screw cap. If the screw cap is open, you can carefully remove the lamp. 1. Housing 2. Plastic cover of the UV-C lamp 3. UV-C lamp 4. Lamp socket and end cap 4. To clean the quartz tube, it can be removed from the housing. Normally, it is very tight and has to be lifted up a little bit with a screw driver or a coin (careful, do not use too much force). Take it out by hand. The quartz tube can be cleaned with water and a soft cloth. If there are calcium deposits on the tube, it can be cleaned with vinegar or commercial decalcifiers. Afterwards, flush it with water. The plastic end part of the quartz tube can be fitted with grease for easy remounting. 9

5. The remounting is made in reverse sequence. The quartz tube is pushed into the housing, the lamp is fastened into the socket and both are carefully mounted in the housing. The screw cap is fixed tight. Finally, the connection pieces are remounted and the hoses are secured with the clamps. 6. The electronic ballast is mainenance-free. If the lamp stops working or does not start anymore although a new lamp is mounted, the ballast has to be changed. This has to be done by a specialist using original Aqua Medic parts, only. 1. Housing 2. Quartz tube 3. Plastic end of the quartz tube (should be fitted with grease before mounting) 7. Warranty Should any defect in material or workmanship be found within 12 months of the date of purchase AB Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of charge always provided the product has been installed correctly, is used for the purpose that was intended by us, is used in accordance with the operating instructions and is returned to us carriage paid. The warranty term is not applicable on the all consumable products. Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer s name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty may not apply if any model or production number has been altered, deleted or removed, unauthorized persons or organisations have executed repairs, modifications or alterations, or damage is caused by accident, misuse or neglect. We regret we are unable to accept any liability for any consequential loss. Please note that the product is not defective under the terms of this warranty where the product, or any of its component parts, was not originally designed and / or manufactured for the market in which it is used. These statements do not affect your statutory rights as a customer. If your AB Aqua Medic GmbH product does not appear to be working correctly or appears to be defective, please contact your dealer in the first instance. Before calling your dealer, please ensure you have read and understood the operating instructions. If you have any questions your dealer cannot answer please contact us. Our policy is one of continual technical improvement and we reserve the right to modify and adjust the specification of our products without prior notification. AB Aqua Medic GmbH - Gewerbepark 24-49143 Bissendorf/Germany - Technical changes reserved - 07/2011 10

11

12

13

14

15

16

17

18

19

20

21

22

23

24