M Series Built-In Ovens

Similar documents
Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

D E S I G N G U I D E ICB REVISED 11 / 2018

NEW GENERATION INTERNATIONAL DESIGN GUIDE

CONTENTS. Throughout this guide, dimensions may vary by ± 1 /8" (3). Dimensions in parentheses are millimeters unless otherwise specified.

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

Wolf New Generation Design Guide

Contents. vary by ± 1 /8" (3). Dimensions in parentheses are millimeters unless otherwise specified.

M SERIES OVENS TRANSITIONAL DO27TM/S/TH VENTILATION OUTDOOR GRILLS RANGES RANGETOPS COOKTOPS COFFEE BUILT-IN OVENS PROFESSIONAL SO30PM/S/PH

Wolf New Generation Design Guide

Contents. IMPORTANT NOTE: Throughout this guide, dimensions may vary by ± 1 /8" (3).

Wolf New Generation Design Guide

MODULES. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Contents. vary by ± 1 /8" (3). Dimensions in parentheses are millimeters unless otherwise specified.

RANGETOPS. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

INSTALLATION GUIDE Warming Drawers

Wolf Design Guide REVISED 3/2015

Contents. vary by ± 1 /8" (3). Dimensions in parentheses are millimeters unless otherwise specified.

MODL WWD30 STAINLSS STL DRAWR FRONT FATURS Stainless steel drawer front and tubular handle available in classic, platinum and carbon finishes 850-watt

L Series Built-In Ovens

Taking the experience we ve gained from our

FATURS Classic, platinum and carbon stainless steel trim finishes asy-to-clean black ceramic glass surface is resistant to scratching, staining, impac

30" (762) Warming Drawer FEATURES

INSTALLATION INSTRUCTIONS

D ESIGN G UIDE O VENS C OOKTOPS R ANGES R ANGETOPS BBQ G RILLS V ENTILATION

New features make cooking a greater pleasure than

If you want to offer a more professional look to your

With Wolf's dual fuel ranges you have state-of-the-art

With Wolf's dual fuel ranges you have state-of-the-art

Taking the experience we ve gained from our

Model Serial Number and Product Rating Guide

There's a good reason why professional chefs choose

If it looks as if it could be in a restaurant kitchen, well,

If it looks as if it could be in a restaurant kitchen, well,

Induction cooking has been used in Europe for decades

With Wolf's dual fuel ranges you have state-of-the-art

Warming Drawer Installation Guide

Model / Serial Number and Product Rating Guide

INSTALLATION GUIDE Induction Cooktops

To round out your options for the ideal kitchen, you

INSTALLATION GUIDE Dual Fuel Ranges

From a temperature of 140 F (60 C) to boil, you can

D E S I G N G U I D E

Multi-Function Cooktop

Who says you have to sacrifice the fun of grilling

SEALED BURNER RANGETOPS

PRG486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly.

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly.

PRD606RCG 60-INCH DUAL-FUEL PRO GRAND RANGE WITH GRILL AND GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

108 Ranges. Ranges. A range of ways to cook. One exceptional way to engineer them.

INSTALLATION GUIDE Steamer Module

PRG364JDG 36-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRD48JDSGU 48-INCH DUAL-FUEL PRO GRAND RANGE WITH STEAM AND GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRD606RESG 60-INCH DUAL-FUEL PRO GRAND RANGE WITH STEAM AND DOUBLE GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRL305PH 30-INCH GAS PRO HARMONY RANGE (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRD486NLGU 48-INCH DUAL-FUEL PRO GRAND RANGE WITH GRILL PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

True Convection Single convection fan circulates hot air throughout the oven for faster and more even multi-rack baking.

premiu m appliance coll[ection

Built-In Cooktop FPGC3087MS. 30" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

INSTALLATION GUIDE Fryer Module

PCG305P 30-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE

PRG486NLG 48-INCH GAS PRO GRAND RANGE WITH GRILL PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRG486JDG 48-INCH GAS PRO GRAND RANGE WITH GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PCG364WD 36-INCH GAS RANGETOP WITH GRIDDLE PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE GENERAL PROPERTIES. Sealed Burners

PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE GENERAL PROPERTIES. Sealed Burners

Quick Preheat Preheat in less than six minutes. 1

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

WOLF BUYING GUIDE. A step-by-step guide to find the right Wolf products for your home project

24 Cooktops. Cooktops. Precise performance meets streamlined design.

PRD305PH 30-INCH DUAL-FUEL PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRD486NLHU 48-INCH DUAL-FUEL PRO HARMONY RANGE WITH GRILL PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

Dual-Fuel Built-In Range

PRD48NLSGU 48-INCH DUAL-FUEL PRO GRAND RANGE WITH STEAM AND GRILL PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

D E S I G N G U I D E

DISHWASHER DESIGN GUIDE

Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

PRL486GDH 48-INCH GAS PRO HARMONY RANGE WITH GRIDDLE (LP) PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

PRD486GDHU 48-INCH DUAL-FUEL PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

Kieffer s Buying Guide: Wall Ovens

TWO SPECIALISTS. ONE EXTRAORDINARY KITCHEN.

MODEL SHOWN: PRD486GDHU 48-INCH PRO HARMONY RANGE WITH GRILL ACCESSORY

PRD48JDSGU 48-INCH DUAL-FUEL PRO GRAND RANGE WITH STEAM AND GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

GAS COOKTOPS INSTALLATION INSTRUCTIONS. Model numbers ICBCG15 ICBCG304 ICBCG365

PRG486GDH 48-INCH GAS PRO HARMONY RANGE WITH GRIDDLE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE

Express-Select Controls Easily go from warm to boil.

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PRD364NLGU 36-INCH DUAL-FUEL PRO GRAND RANGE WITH GRILL PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

PRD484NCGU 48-INCH DUAL-FUEL PRO GRAND RANGE WITH GRIDDLE AND GRILL PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

Dual-Fuel Built-In Range

PRD364NLGU 36-INCH DUAL-FUEL PRO GRAND RANGE WITH GRILL PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

Built-In Cooktops FGGC3665K S/W/B. 36" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

Express-Select Controls Easily go from warm to boil.

TABLE OF CONTENTS SUB-ZERO WOLF 09 THE SUB-ZERO DIFFERENCE 13 BUILT-IN REFRIGERATION 17 PRO 48 REFRIGERATION 19 INTEGRATED REFRIGERATION

PRD48JDSGU 48-INCH DUAL-FUEL PRO GRAND RANGE WITH STEAM AND GRIDDLE PROFESSIONAL SERIES, COMMERCIAL-DEPTH, PORCELAIN COOKTOP SURFACE

96 MODEL SHOWN: PCG486GD 48-INCH RANGETOP

Gas Built-In Range EW30GS75KS. Featuring Wave-Touch Electronic Controls

PowerPlus Preheat Preheat in less than six minutes. 1

Continuous Grates Continuous grates make it easy to move heavy pots and pans between burners without lifting.

Transcription:

DSIGN GUID ICB RVISD 1 / 2017

TA B L O F C O N T N T S 3 B U I L T- I N O V N S 30 MICROWAV OVNS 35 WARMING DRAWRS 40 COOKTOPS MODULS 60 COFF SYSTMS CUP WARMING DRAWRS 69 RANGS RANGTOPS 78 C O O K T O P V N T I L AT I O N 83 DOWNDRAFTS 87 P R O V N T I L AT I O N 95 WOLF WARRANTY Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3.

UPPR OVN LOWR OVN M SRIS OVNS M Series Built-In Ovens Four striking looks are just the beginning. Superior performance features include our advanced Dual VertiCross convection fan system, touch-screen controls, convenient preset cooking programs and improved interior lighting. There is more usable space inside for deliciousness on a grand scale. M series ovens can be installed in a standard or flush inset application. M SRIS OVNS TRANSITIONAL ICBSO30TM/S/TH PROFSSIONAL ICBSO30PM/S/PH CONTMPORARY ICBSO30CM/S ICBSO30CM/B ICBDO30TM/S/TH ICBDO30PM/S/PH ICBDO30CM/S ICBDO30CM/B BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 3

M SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS M Series Built-In Ovens TRANSITIONAL SINGL OVN 759 723 65 TRANSITIONAL DOUBL OVN 759 1291 65 22 51 218 36 CONDUIT CHANNL 584 BHIND FRAM 22 51 36 CONDUIT CHANNL 218 584 BHIND FRAM 686 1254 46 OPN OVN DOOR 46 OPN OVN DOOR 543 543 4 nglish

UPPR OVN LOWR OVN M SRIS OVNS M Series Built-In Ovens PROFSSIONAL SINGL OVN 759 723 83 PROFSSIONAL DOUBL OVN 759 1291 83 22 51 36 CONDUIT CHANNL 218 584 BHIND FRAM 22 51 218 36 CONDUIT CHANNL 584 BHIND FRAM 686 1254 46 OPN OVN DOOR 46 OPN OVN DOOR 543 543 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 5

M SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS M Series Built-In Ovens CONTMPORARY SINGL OVN STAINLSS STL 759 759 723 1291 22 51 584 BHIND FRAM 22 51 36 CONDUIT CHANNL 36 CONDUIT CHANNL 218 218 584 BHIND FRAM 686 CONTMPORARY DOUBL OVN STAINLSS STL 1254 46 OPN OVN DOOR 46 OPN OVN DOOR 543 543 6 nglish

M SRIS OVNS M Series Built-In Ovens CONTMPORARY SINGL OVN BLACK GLASS 759 759 723 1291 25 51 584 BHIND FRAM 25 51 36 CONDUIT CHANNL 218 CONTMPORARY DOUBL OVN BLACK GLASS 36 CONDUIT CHANNL 218 584 BHIND FRAM 686 1254 46 OPN OVN DOOR 46 OPN OVN DOOR 543 543 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 7

M SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information The M series oven can be installed in a standard or flush inset application. If a cooktop is being installed above an oven, a minimum of 6 is required between units. Location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Single Oven Double Oven TRIM OVRLAP Top Bottom Sides DUAL INSTALLATION MIN 115 kg 181 kg 25 0 18 Two 76 cm single M series ovens can be installed side by side in a standard or flush inset application. A dual installation kit is required. To maintain appropriate airflow, the ovens must be installed into one opening. Any cosmetic or structural material placed between the ovens will impede airflow and is not recoended. Refer to illustrations on the following pages. The dual installation kit is available through an authorized Wolf dealer. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit. Performance may be compromised if the electrical supply is less than 220 volts. The oven is supplied with a single phase and 3-phase convertible power inlet box. The wiring diagram covering the control circuit is provided with the oven. LCTRICAL RQUIRMNTS SINGL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 4.2 4.8 kw 3.0 3.6 kw DOUBL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 8.4 9.6 kw 4.2 4.8 kw 8 nglish

M SRIS OVNS M Series Single Oven STANDARD INSTALLATION SID VIW NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. OPNING WIDTH 699 OPNING HIGHT 76 cm Model 724 W TOP VIW FRONT VIW 591 OPNING DPTH 127 W OPNING WIDTH 102 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 9

M SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS M Series Double Oven STANDARD INSTALLATION SID VIW NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. OPNING WIDTH 1267 OPNING HIGHT 432 TYPICAL 76 cm Model 724 W TOP VIW FRONT VIW 591 OPNING DPTH 127 W OPNING WIDTH 102 10 nglish

M SRIS OVNS M Series Single Oven FLUSH INST INSTALLATION SID VIW *25 minimum depth. Shaded areas will be visible and should be finished to match cabinetry. **22 for professional and transitional models and 25 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. FLUSH INST WIDTH 730 FLUSH INST HIGHT*** 76 cm Model 765 W 22 OR 25 ** 21 TOP VIW 29 3 FRONT VIW 610 FLUSH INST DPTH W FLUSH INST WIDTH*** 127 102 FINISHD CLATS* BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 11

M SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS M Series Double Oven FLUSH INST INSTALLATION SID VIW *25 minimum depth. Shaded areas will be visible and should be finished to match cabinetry. **22 for professional and transitional models and 25 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. FLUSH INST WIDTH 1299 FLUSH INST HIGHT*** 432 TYPICAL 76 cm Model 765 W 22 OR 25 ** 21 TOP VIW 29 3 FRONT VIW 610 FLUSH INST DPTH W FLUSH INST WIDTH*** 127 102 FINISHD CLATS* 12 nglish

WATR LIGHT TMP MOD OK TIMR TIM OFF WARM LIGHT TMP MOD OK TIMR TIM OFF SRIS OVNS Series Built-In Ovens Stainless models feature a redesigned stainless steel touch-action control panel, helping to create great meals with ease, as well as adding a striking design feature to the kitchen. Smart technology gives the series ten cooking modes, with Wolf s innovative dual convection in single ovens and in the upper unit of double ovens. Wolf series ovens are crafted of stainless steel. Tubular handles have been updated to match the rest of the new Wolf cooking appliance offering, providing a more cohesive look. series ovens can be installed in a standard or flush inset application. SRIS OVNS TRANSITIONAL ICBSO2418T/S/TH ICBSO30T/S/TH PROFSSIONAL ICBSO30P/S/PH CONTMPORARY ICBSO30C/B/TH ICBSO24T/S/TH ICBDO30T/S/TH ICBDO30P/S/PH ICBDO30C/B/TH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 13

WATR LIGHT TMP MOD OK TIMR TIM OFF WARM LIGHT TMP MOD OK TIMR TIM OFF SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 60 cm Series Ovens MODL ICBSO2418T/S/TH TRANSITIONAL SINGL OVN MODL ICBSO24T/S/TH TRANSITIONAL SINGL OVN 597 454 597 64 22 597 64 546 BHIND FRAM 22 546 BHIND FRAM 446 591 538 OPN OVN DOOR 559 OPN OVN DOOR 360 460 14 nglish

SRIS OVNS 76 cm Series Ovens TRANSITIONAL SINGL OVN 759 25 708 70 TRANSITIONAL DOUBL OVN 25 1280 759 70 76 CONDUIT CHANNL 689 603 BHIND FRAM 76 CONDUIT CHANNL 603 BHIND FRAM 1261 225 718 OPN OVN DOOR 225 718 OPN OVN DOOR 244 244 559 559 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 15

SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 76 cm Series Ovens PROFSSIONAL SINGL OVN 759 25 708 86 PROFSSIONAL DOUBL OVN 759 25 1280 86 76 CONDUIT CHANNL 689 603 BHIND FRAM 76 CONDUIT CHANNL 603 BHIND FRAM 1261 225 718 OPN OVN DOOR 225 718 OPN OVN DOOR 244 244 559 559 16 nglish

SRIS OVNS 76 cm Series Ovens CONTMPORARY SINGL OVN 759 32 708 76 CONTMPORARY DOUBL OVN 32 1280 759 76 76 CONDUIT CHANNL 603 BHIND FRAM 76 CONDUIT CHANNL 603 BHIND FRAM 687 1257 225 718 OPN OVN DOOR 225 718 OPN OVN DOOR 244 244 559 559 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 17

SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information The series oven can be installed in a standard or flush inset application. If a cooktop is being installed above an oven, a minimum of 6 is required between units. Location of the electrical supply within the oven opening may require additional cabinet depth. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 6 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT MIN 60 cm Single Oven 68 kg 76 cm Single Oven 115 kg 76 cm Double Oven 181 kg TRIM OVRLAP 60 cm MODL 76 cm MODL Top 6 13 Bottom 0 3 Sides 17 17 LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the back wall and within the shaded area shown in the illustration for your specific installation on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit. The 76 cm units are supplied with terminal box convertible to single or 3-phase. The wiring diagram covering the control circuit is provided with the oven. LCTRICAL RQUIRMNTS 60 cm SINGL OVN lectrical Supply Service Receptacle Power Cord LCTRICAL RQUIRMNTS 220-240 V AC, 50 Hz 3400 W grounding-type (earthed) 1.8 m 76 cm SINGL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Max Connected Load 4.4 kw 4.4 kw Total Amps 19 19 76 cm DOUBL OVN SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Max Connected Load 7.4 kw 5.1 kw Total Amps 32 22 18 nglish

SRIS OVNS 60 cm Series Oven STANDARD INSTALLATION SID VIW NOT: lectrical supply must be located in adjacent cabinet within.9 m of opening. OPNING HIGHT Model ICBSO2418T/S/TH Model ICBSO24T/S/TH H OPNING HIGHT H 449 591 TOP VIW FRONT VIW 572 OPNING DPTH 562 OPNING WIDTH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 19

SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 76 cm Series Single Oven STANDARD INSTALLATION SID VIW 692 OPNING HIGHT NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. TOP VIW FRONT VIW 610 OPNING DPTH 127 724 OPNING WIDTH 102 20 nglish

SRIS OVNS 76 cm Series Double Oven STANDARD INSTALLATION SID VIW 1264 OPNING HIGHT 432 TYPICAL NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. TOP VIW FRONT VIW 610 OPNING DPTH 127 724 OPNING WIDTH 102 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 21

SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 60 cm Series Oven FLUSH INST INSTALLATION SID VIW *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: lectrical supply must be located in adjacent cabinet within.9 m of opening. FLUSH INST HIGHT Model ICBSO2418T/S/TH Model ICBSO24T/S/TH H FLUSH INST HIGHT** H 467 610 22 24 TOP VIW 13 6 610 FLUSH INST WIDTH** FRONT VIW 584 FLUSH INST DPTH FINISHD CLATS* 22 nglish

SRIS OVNS 76 cm Series Single Oven FLUSH INST INSTALLATION SID VIW 721 FLUSH INST HIGHT*** 981 TYPICAL *Will be visible and should be finished to match cabinetry. **25 for professional and transitional models and 32 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. 25 OR 32 ** 24 TOP VIW 19 10 FRONT VIW 635 FLUSH INST DPTH 772 FLUSH INST WIDTH*** 127 102 FINISHD CLATS* BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 23

SRIS OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 76 cm Series Double Oven FLUSH INST INSTALLATION SID VIW 1292 FLUSH INST HIGHT*** 432 TYPICAL *Will be visible and should be finished to match cabinetry. **25 for professional and transitional models and 32 for contemporary model. ***Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. Dashed line represents profile of unit. 25 OR 32 ** 24 TOP VIW 19 FRONT VIW 635 FLUSH INST DPTH 772 FLUSH INST WIDTH*** 10 127 102 FINISHD CLATS* 24 nglish

WATR LIGHT TMP MOD OK TIMR TIM OFF CONVCTION STAM OVNS Convection Steam Ovens The legacy of the combination oven goes back decades, to innovative chefs in America and urope who embraced the combination of air movement with superheated steam to achieve superior results from breads and roasts to delicate fishes, seafood and vegetables. Wolf combines the benefits of convection and steam for the most innovative steam oven on the market today. Virtually any dish prepared in a conventional oven, range or microwave can also be prepared in the Wolf convection steam oven with more control. Two widths and three distinct styles compliment the look of Wolf ovens, ranges and cooktops. Convection steam ovens can be installed in a standard or flush inset application. CONVCTION STAM OVNS TRANSITIONAL ICBCSO24T/S/TH ICBCSO30TM/S/TH PROFSSIONAL ICBCSO30PM/S/PH ICBCSO30P/S/PH CONTMPORARY ICBCSO30CM/B/TH ICBCSO30T/S/TH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 25

CONVCTION STAM OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Convection Steam Ovens TRANSITIONAL WIDTH W WIDTH PROFSSIONAL 454 64 454 22 546 BHIND FRAM 60 cm Model 597 76 cm Model 759 22 759 83 546 BHIND FRAM CONTMPORARY 759 454 64 22 546 BHIND FRAM 446 W 446 446 538 OPN OVN DOOR 538 OPN OVN DOOR 538 OPN OVN DOOR 360 360 360 26 nglish

CONVCTION STAM OVNS Planning Information The convection steam oven can be installed in a standard or flush inset application. The electrical supply for the oven must be located in an adjacent cabinet. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Convection Steam Oven MIN 45 kg TRIM OVRLAP 60 cm MODL 76 cm MODL Top 5 5 Bottom 0 0 Sides 18 98 LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. Performance may be compromised if the electrical supply is less than 220 volts. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle Power Cord 220-240 V AC, 50 Hz 3800 W grounding-type (earthed) 1.8 m BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 27

CONVCTION STAM OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Convection Steam Oven STANDARD INSTALLATION SID VIW 449 OPNING HIGHT NOT: Both 60 cm and 76 cm models require the same opening dimensions. lectrical supply must be located in adjacent cabinet within.9 m of opening. Dashed line represents profile of unit. OPNING WIDTH 60 cm Model 562 76 cm Model 562 W TOP VIW FRONT VIW 548 OPNING DPTH W OPNING WIDTH 28 nglish

CONVCTION STAM OVNS Convection Steam Oven FLUSH INST INSTALLATION SID VIW 460 FLUSH INST HIGHT** *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: lectrical supply must be located in adjacent cabinet within.9 m of opening. Dashed line represents profile of unit. FLUSH INST WIDTH W A 60 cm Model 603 21 76 cm Model 765 102 A 25 TOP VIW 8 3 W FLUSH INST WIDTH** FRONT VIW 584 FLUSH INST DPTH FINISHD CLATS* BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 29

MICROWAV OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Microwave Ovens As true cooking instruments, Wolf microwave ovens have features that make fast meals better meals. New drop down door microwaves feature a door that hinges at the bottom. Drop down door microwaves are designed to match Wolf transitional, professional and contemporary products. Microwave ovens can be installed in a standard or flush inset application. DROP DOWN DOOR MICROWAVS TRANSITIONAL ICBMDD24T/S/TH ICBMDD30TM/S/TH PROFSSIONAL ICBMDD30PM/S/PH ICBMDD30P/S/PH CONTMPORARY ICBMDD30CM/B/TH ICBMDD30T/S/TH 30 nglish

MICROWAV OVNS Drop Down Door Microwave Ovens TRANSITIONAL WIDTH W WIDTH 454 64 22 538 546 BHIND FRAM 60 cm Model 597 76 cm Model 759 PROFSSIONAL 454 759 83 546 BHIND FRAM CONTMPORARY 759 454 64 22 546 BHIND FRAM 446 W 446 OPN OVN DOOR 538 OPN OVN DOOR 22 538 446 OPN OVN DOOR 360 360 360 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 31

MICROWAV OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information DROP DOWN DOOR MICROWAV The drop down door microwave oven can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the door is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Drop Down Door Microwave MIN 57 kg TRIM OVRLAP 60 cm MODL 76 cm MODL Top 5 5 Bottom 0 0 Sides 18 98 lectrical Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. The receptacle may also be located in an adjacent cabinet within reach of the power cord. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. Refer to the illustration below for minimum power cord plug clearance. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle 220-240 V AC, 50/60 Hz 1600 W grounding-type (earthed) 32 nglish

MICROWAV OVNS Drop Down Door Microwave Oven STANDARD INSTALLATION SID VIW NOT: Both 60 cm and 76 cm models require the same opening dimensions. Dashed line represents profile of unit. OPNING WIDTH 449 OPNING HIGHT 60 cm Model 562 76 cm Model 562 W TOP VIW FRONT VIW 548 OPNING DPTH W OPNING WIDTH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 33

MICROWAV OVNS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Drop Down Door Microwave Oven FLUSH INST INSTALLATION SID VIW 460 FLUSH INST HIGHT** *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: Dashed line represents profile of unit. FLUSH INST WIDTH W A 60 cm Model 603 21 76 cm Model 765 102 A 25 TOP VIW 8 3 W FLUSH INST WIDTH** FRONT VIW 584 FLUSH INST DPTH FINISHD CLATS* 34 nglish

WARMING DRAWRS Warming Drawers Wolf warming drawers are designed to take care of prepared foods until it s time to serve them. You can adjust the temperature, keeping moist foods moist and crisp foods crisp. Warming drawers are ideal for proofing dough. Drawer fronts are available to match the look of Wolf ovens and sealed burner rangetops. The integrated drawer front allows for a custom panel and handle. WARMING DRAWR FRONTS M SRIS TRANSITIONAL PROFSSIONAL INTGRATD CUSTOM PANL CONTMPORARY BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 35

WARMING DRAWRS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Warming Drawers DRAWR FRONT OPTIONS Wolf warming drawer fronts allow for many design options, but the warming drawer itself will be the same for all applications. A panel mounting kit is required when installing a custom panel. The panel mounting kit is available through an authorized Wolf dealer. The 51 thick drawer front, in 76 cm and 91 cm widths, is designed to be installed below a sealed burner rangetop, so the panel aligns properly with the front of the rangetop. Dimensions for the warming drawer remain the same, even though the drawer front may be wider to match a Wolf 91 cm oven or sealed burner rangetop. DIMNSIONS W WIDTH 718 OPN DRAWR DRAWR FRONT 264 546 B A 578 229 MODL W 76 cm Drawer Front 759 91 cm Drawer Front 911 M SRIS A B Transitional Professional 22 83 Contemporary 25 86 SRIS A B Transitional Professional 29 89 Professional (51 thick) 54 114 Contemporary 35 95 INTGRATD DRAWR FRONT CUSTOM PANL W H D Typical Dimensions 759 264 19 Min Thickness 16 36 nglish

WARMING DRAWRS Planning Information The warming drawer must be installed with a Wolf drawer front, avail able through an authorized Wolf dealer. Specific installation instructions are included with the drawer front. The warming drawer can be installed in a standard or flush inset application. For a standard installation, the drawer collar and front panel sit proud of the cabinet face frame. A recessed installation requires the cabinetry be recessed by 5 so the collar is flush with the cabinet face frame but the drawer front will sit proud. A flush inset installation requires the drawer collar and front panel be recessed to be flush with surrounding cabinetry. Refer to illustrations on the following pages for minimum cabinet dimensions for your specific installation. Finish the edges of the opening. They may be visible when the drawer is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Warming Drawer TRIM OVRLAP Top, Bottom and Sides MIN 90 kg 16 LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the warming drawer can be placed in an adjacent cabinet within reach of the power cord. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle Power Cord 220-240 V AC, 50/60 Hz 850 W grounding-type (earthed).9 m BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 37

WARMING DRAWRS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Warming Drawer STANDARD INSTALLATION SID VIW ANTI-TIP BLOCK 232 OPNING HIGHT NOT: Location of electrical supply within opening may require additional cabinet depth. TOP VIW 727 OPNING WIDTH FRONT VIW 584 OPNING DPTH 38 nglish

WARMING DRAWRS Warming Drawer FLUSH INST INSTALLATION SID VIW ANTI-TIP BLOCK 270 FLUSH INST HIGHT** *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: Location of electrical supply within opening may require additional cabinet depth. DRAWR FRONT DPTH (A) M SRIS SRIS Transitional Professional 22 29 Professional (51 thick) NA 54 Contemporary 25 35 Custom front panel depth is dependent on panel thickness. A DRAWR FRONT DPTH 19 TOP VIW 19 FRONT VIW 610 FLUSH INST DPTH 19 765 FLUSH INST WIDTH** FINISHD CLATS* BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 39

INDUCTION COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Induction Cooktops Almost instantaneous temperature response. Practically no wasted heat. Induction cooking has been popular among uropean chefs and homeowners for decades. Now Wolf leads the way in bringing this remarkable technology to North American kitchens. Its secret is magnetism. lectromagnetic elements cause iron and magnetic stainless cookware to heat up instantly and with perfectly distributed heat. Heat generation stops the instant you turn off the element or remove the pan. The cooktop s surface remains cool. Your kitchen stays cooler too. Transitional models have a brushed stainless steel trim. Contemporary models can be mounted flush with the countertop. The following models have the same stainless steel frame as our module cooktops for paired installations: ICBCI152TF/S, ICBCI243TF/S, ICBCI304TF/S, and ICBCI365TF/S. INDUCTION COOKTOPS TRANSITIONAL ICBCI152TF/S ICBCI243TF/S ICBCI365TF/S ICBCI304T/S ICBCI365T/S CONTMPORARY ICBCI243C/B ICBCI304C/B ICBCI304TF/S ICBCI365C/B 40 nglish

INDUCTION COOKTOPS Induction Cooktops 38 cm TRANSITIONAL 32 381 CONDUIT 22 533 51 91 cm TRANSITIONAL 600 32 914 CONDUIT 22 32 CONDUIT 22 60 cm CONTMPORARY 533 64 533 51 60 cm TRANSITIONAL 600 32 CONDUIT 22 76 cm CONTMPORARY 762 32 533 51 CONDUIT 22 533 64 76 cm TRANSITIONAL 762 32 CONDUIT 22 533 51 91 cm CONTMPORARY 914 32 CONDUIT 22 533 64 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 41

INDUCTION COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Induction Cooktops LMNT RATING 38 cm COOKTOP W 216 2300 3150 boost 152 1400 60 cm COOKTOP W 279 2600 3150 boost 203 2100 203 2100 3000 boost 76 cm COOKTOP W 279 2600 3150 boost 203 2100 203 2100 3000 boost 152 1400 91 cm COOKTOP W 279 2600 3700 boost (2) 203 2100 (2) 203 2100 3000 boost Planning Information A minimum height clearance of 159 is required from the top of the countertop to any combustible surface directly below the cooktop. Contemporary induction cooktops can be mounted flush with the top of the countertop, or as a frameless standard installation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cut-out must be provided. Wolf downdraft systems cannot be used with contemporary induction cooktops. IMPORTANT NOT: Flush mount installations are intended for granite, solid surface or stone countertop surfaces only. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. Performance may be compromised if the electrical supply is less than 220 volts. The cooktop is supplied with a single phase and 3-phase convertible power inlet box. LCTRICAL RQUIRMNTS INDUCTION COOKTOPS SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 380-415 V AC 50/60 Hz 50 Hz TOTAL AMPS SINGL PHAS 3-PHAS 38 cm Induction 16 16 60 cm Induction 30 16 76 cm Induction 32 16 91 cm Induction 48 16 42 nglish

INDUCTION COOKTOPS 38 cm Induction Cooktop STANDARD INSTALLATION 330 SID VIW 914 min FLOOR TO COUNTRTOP 457 51 356 COUNTRTOP CUT-OUT 762 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 64 495 64 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 43

INDUCTION COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 60 cm 76 cm 91 cm Induction Cooktop STANDARD INSTALLATION 330 SID VIW COUNTRTOP CUT-OUT 762 89 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. lectrical supply location only applies to installations with built-in oven. CUT-OUT WIDTH 914 min FLOOR TO COUNTRTOP 457 51 60 cm Cooktop 562 76 cm Cooktop 737 91 cm Cooktop 889 W W WIDTH 114 254 64 495 64 44 nglish

INDUCTION COOKTOPS 60 cm 76 cm 91 cm Induction Cooktop FLUSH INSTALLATION 330 SID VIW 22 MAX COUNTRTOP PROFIL 8 914 min FLOOR TO COUNTRTOP 537 RCSS 40 min 457 51 W CUT-OUT WIDTH A RCSS COUNTRTOP CUT-OUT 762 89 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. lectrical supply location only applies to installations with built-in oven. Outside corner radius 11. CUT-OUT WIDTH W A 60 cm Cooktop 562 603 76 cm Cooktop 737 765 91 cm Cooktop 889 918 114 254 64 495 64 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 45

GAS COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Gas Cooktops Like their oven counterparts, the new generation of Wolf gas cooktops features three new looks transitional, professional and contemporary. New performance enhancements make delicious results even more of a certainty than ever. Multiple sizes, choice of knob colors and distinctly different grates the new gas cooktops offer exceptional design flexibility. For a striking, low-profile look, the contemporary gas cooktop fits flush to the countertop with front-mounted controls that integrate directly into cabinetry below. GAS COOKTOPS TRANSITIONAL ICBCG152TF/S ICBCG304T/S PROFSSIONAL ICBCG304P/S ICBCG365P/S CONTMPORARY ICBCG365C/S ICBCG365T/S 46 nglish

GAS COOKTOPS Gas Cooktops 38 cm TRANSITIONAL 381 22 762 533 102 76 cm PROFSSIONAL 22 91 cm CONTMPORARY 913 22 533 102 532 171 76 cm TRANSITIONAL 762 22 533 102 91 cm PROFSSIONAL 914 22 BURNR RATING 533 102 91 cm TRANSITIONAL 914 22 533 102 38 cm TRANSITIONAL kw Medium 3.5 Small 2.7 76 cm TRANSITIONAL PROFSSIONAL kw Large 5.3 Medium 3.5 (2) Small 2.7 91 cm TRANSITIONAL PROFSSIONAL kw Large 5.3 Medium 3.5 (3) Small 2.7 91 cm CONTMPORARY kw Large 5.9 (2) Medium 3.5 (2) Small 2.7 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 47

GAS COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information A minimum 51 is required from the bottom of the cooktop to combustible materials. If a cooktop is installed above an oven, a minimum of 6 is required between units. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustration on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle Power Cord 220-240 V AC, 50/60 Hz 0.2 A grounding-type (earthed) 1.8 m GAS SUPPLY A gas supply line of 19 rigid pipe must be provided to the cooktop. If local codes permit, a certified,.9 m long, 13 or 19 ID flexible metal appliance connector is recoended to connect the units ISO 7/1-14 male inlet to the gas supply line. 76 cm and 91 cm gas cooktops contain a regulator for natural gas and LP gas. Wolf natural gas cooktops will function up to 3124 m in altitude without adjustment and LP gas cooktops will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit. 38 cm COOKTOP GAS RQUIRMNTS NATURAL GAS Supply Pressure LP GAS Supply Pressure 76 cm 91 cm COOKTOP GAS RQUIRMNTS NATURAL GAS Supply Pressure Min Line Pressure Max Regulator Pressure LP GAS Supply Pressure Min Line Pressure Max Regulator Pressure WC 25 mbar WC 37 mbar WC 12.5 mbar 17.5 mbar 100 mbar WC 25 mbar 27.4 mbar 100 mbar 48 nglish

GAS COOKTOPS 38 cm Transitional Gas Cooktop STANDARD INSTALLATION 330 SID VIW 457 178 356 COUNTRTOP CUT-OUT 762 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. G 64 495 64 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 49

GAS COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 76 cm 91 cm Transitional Professional Gas Cooktop STANDARD INSTALLATION 330 SID VIW COUNTRTOP CUT-OUT 89 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. lectrical and gas supply location only applies to installations with built-in oven. CUT-OUT WIDTH 457 229 76 cm Cooktop 737 91 cm Cooktop 889 W W WIDTH 762 102 G 254 64 495 64 50 nglish

GAS COOKTOPS 91 cm Contemporary Gas Cooktop STANDARD INSTALLATION 330 SID VIW 51 MIN 127 MAX 457 229 762 889 CUT-OUT WIDTH COUNTRTOP CUT-OUT 127 254 C L FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Maximum facade thickness 25. 32 DIAMTR G 64 508 4" 98 (102) MIN 130 MAX C L BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 51

MODUL COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS 91 cm Contemporary Gas Cooktop FLUSH INSTALLATION 330 SID VIW 13 MAX COUNTRTOP PROFIL 2 51 MIN 127 MAX 457 533 MIN RCSS 229 762 889 CUT-OUT WIDTH 914 MIN RCSS COUNTRTOP CUT-OUT 127 254 C L FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. Maximum facade thickness 25. Outside corner radius 10. 32 DIAMTR G 64 508 4" 98 (102) MIN 130 MAX C L 52 nglish

MODUL COOKTOPS Module Cooktops Wolf 38 cm modules have been redesigned to match the updated lines of Sub-Zero and Wolf. Controls, grates and trim allow them to integrate perfectly with their larger counterparts and deliver equal performance. Combine modules à la carte-style to create a custom cooktop, or add specialty functions alongside an existing cooktop. Full-size cooktops including CI243TF/S, CI304TF/S, and CI365TF/S feature the same brushed stainless frame making them ideal for pairing with modules. ADDITIONAL MODLS For additional 38 cm induction and gas cooktops, refer to the previous cooktop sections. MODUL COOKTOPS ICBSM15TF/S STAMR ICBGM15TF/S GRILL ICBTM15TF/S TPPANYAKI ICBMM15TF/S MULTIFUNCTION BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 53

MODUL COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Module Cooktops STAMR GRILL TPPANYAKI 22 381 DRAIN OUTLT 102 533 222 32 381 22 533 152 381 22 533 102 MULTIFUNCTION 381 22 533 127 54 nglish

MODUL COOKTOPS Planning Information IMPORTANT NOT: Wolf does not recoend the use of downdraft ventilation with the steamer or grill modules. A minimum 51 is required from the bottom of the module to combustible materials. For the teppanyaki module, a minimum 22 is required from the bottom of the unit to any material. Refer to illustrations on the following pages for installation of modules. For additional 38 cm induction, electric and gas cooktops, refer to the previous cooktop sections. When multiple modules are installed side by side, refer to the chart and illustration below for typical configurations. The cut-out dimensions provided will accoodate the use of an optional filler strip if desired. COUNTRTOP CUT-OUT W* (2) 38 cm Modules 737 (3) 38 cm Modules 1118 cm (4) 38 cm Modules 1505 cm (5) 38 cm Modules 1886 cm (6) 38 cm Modules 2267 cm *Dimensions apply to ICBCI152TF/S, ICBC152TF/S, ICBCG152TF/S, ICBSM15TF/S, ICBGM15TF/S, ICBTM15TF/S and ICBMM15TF/S. 64 * MIN 64 * MIN Countertop cut-out. W* CUT-OUT WIDTH FRONT OF COUNTRTOP 495 * CUT-OUT DPTH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 55

MODUL COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. When multiple cooktops or modules are installed side by side, each must have its own separate electrical supply. LCTRICAL RQUIRMNTS LCTRIC MODULS lectrical Supply Steamer Grill Teppanyaki GAS MODULS lectrical Supply Service Receptacle Power Cord DRAIN OUTLT 220-240 VAC, 50/60 Hz 2700 W 2800 W 2800 W 220-240 VAC; 50/60 Hz 0.2 A 3-prong grounding-type 1.8 m Steamer modules require a method for draining hot water. Options include connecting a drain hose from the 16 outlet tied into an existing drain, a separate drain with freefall or placing a heat-resistant receptacle under the drain outlet. GAS SUPPLY Installation must conform with all applicable gas codes. For the multifunction module, a gas supply line of 19 rigid pipe must be provided to the module. If local codes permit, a certified,.9 m long, 13 or 19 ID flexible metal appliance connector is recoended to connect the units ISO 7/1-14 male inlet to the gas supply line. When multiple gas cooktops or modules are installed side by side, they can receive their gas supply from a coon line. However, each unit must have its own regulator installed between the mainline and the cooktop or module. Wolf natural gas cooktops will function up to 3124 m in altitude without adjustment and LP gas cooktops will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit. GAS RQUIRMNTS NATURAL GAS Supply Pressure LP GAS Supply Pressure WC 25 mbar WC 37 mbar 56 nglish

MODUL COOKTOPS Steamer Module STANDARD INSTALLATION 330 SID VIW 200 457 178 COUNTRTOP CUT-OUT 314 356 762 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 152 DRAIN OUTLT 64 MIN 495 64 MIN BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 57

MODUL COOKTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Grill Teppanyaki Module STANDARD INSTALLATION 330 SID VIW 457 178 356 COUNTRTOP CUT-OUT 762 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 64 MIN 495 64 MIN 58 nglish

MODUL COOKTOPS Multifunction Module STANDARD INSTALLATION 330 SID VIW 457 178 356 COUNTRTOP CUT-OUT 762 FRONT VIW NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. G 64 MIN 495 64 MIN BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 59

COFF SYSTMS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Coffee Systems Make professional-quality coffee, espresso, cappuccino, latte and more. The Wolf coffee system automatically steams and foams the milk perfectly. Water temperature and brew strength are adjustable. Uses either whole-bean or ground coffee. The design pairs beautifully, either sideby-side or in a tower application, with other Wolf products such as the convection steam oven. Coffee systems can be installed in a standard or flush inset application. All 76 cm trim options are based on model ICBC24/B. COFF SYSTMS 60 cm MODLS ICBC24/B ICBC24/S TRANSITIONAL 76 cm M SRIS TRIM 76 cm SRIS TRIM PROFSSIONAL 76 cm M SRIS TRIM 76 cm SRIS TRIM CONTMPORARY 76 cm M SRIS TRIM 60 nglish

COFF SYSTMS Coffee System DIMNSIONS WIDTH W WIDTH 454 22 394 BHIND FRAM 60 cm Model 597 76 cm Trim 759 W UNIT FULL XTNSION 464 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 61

COFF SYSTMS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information The coffee system can be installed in a standard or flush inset application. All 76 cm trim options are based on model ICBC24/B. The sides of the cabinetry opening must be adequate to support installation of the mounting slides. Refer to the illustration below. Finish the edges of the opening. They may be visible when the unit is slid forward. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. INSTALLATION RQUIRMNTS BAS SUPPORT Coffee System MIN 45 kg TRIM OVRLAP 60 cm MODL 76 cm TRIM Top 5 5 Bottom 0 0 Sides 18 98 COMBINATION INSTALLATION To install a coffee system above a cup warming drawer, one opening for both units must be specified. To achieve the minimum reveal between units, place the coffee system support rails on top of the cup warming drawer, then secure the rails to the sides of the cabinet. Any material between the units will increase the horizontal reveal. 356 19 TYPICAL Side support. 254 LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle 220-240 V AC, 50/60 Hz 1350 W grounding-type (earthed) 62 nglish

COFF SYSTMS Coffee System STANDARD INSTALLATION SID VIW SLID SUPPORT 449 OPNING HIGHT SLID SUPPORT NOT: 60 cm model and model with 76 cm trim require the same opening dimensions. Dashed line represents profile of unit. OPNING WIDTH 60 cm Model 562 76 cm Trim 562 W TOP VIW FRONT VIW 548 OPNING DPTH W OPNING WIDTH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 63

COFF SYSTMS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Coffee System FLUSH INST INSTALLATION SID VIW SLID SUPPORT 460 FLUSH INST HIGHT** *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. Dashed line represents profile of unit. SLID SUPPORT FLUSH INST WIDTH W A 60 cm Model 603 21 76 cm Trim 765 102 A 25 TOP VIW 8 3 W FLUSH INST WIDTH** FRONT VIW 584 FLUSH INST DPTH FINISHD CLATS* 64 nglish

CUP WARMING DRAWR Cup Warming Drawers Wolf cup warming drawers preheat cups so hot beverages stay hot longer. The temperature is adjustable. Two model options match the look of Wolf stainless and black coffee systems. Cup warming drawers can be installed in a standard or flush inset application. CUP WARMING DRAWRS ICBCW24/S STAINLSS ICBCW24/B BLACK DIMNSIONS 597 DRAWR FULL XTNSION 140 483 22 533 BHIND FRAM BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 65

CUP WARMING DRAWR VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information The cup warming drawer can be installed in a standard or flush inset application. Finish the edges of the opening. They may be visible when the drawer is open. For standard installations, face trim will overlap stiles and rails. Refer to the chart below. For flush inset installations, a minimum 3 reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90. An anti-tip block must be installed to prevent the cup warming drawer from tipping forward when opened. INSTALLATION RQUIRMNTS BAS SUPPORT Cup Warming Drawer TRIM OVRLAP Top Bottom Sides COMBINATION INSTALLATION MIN 34 kg 0 0 18 To install a cup warming drawer below a coffee system, one opening for both units must be specified. To achieve the minimum reveal between units, place the coffee system support rails on top of the cup warming drawer, then secure the rails to the sides of the cabinet. Any material between the units will increase the horizontal reveal. Installation of an anti-tip block is not necessary when the cup warming drawer is installed below a coffee system. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle 220-240 V AC, 50/60 Hz 550 W grounding-type (earthed) 66 nglish

CUP WARMING DRAWR Cup Warming Drawer STANDARD INSTALLATION SID VIW ANTI-TIP BLOCK 140 OPNING HIGHT NOT: Dashed line represents profile of unit. TOP VIW FRONT VIW 572 OPNING DPTH 562 OPNING WIDTH BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 67

CUP WARMING DRAWR VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Cup Warming Drawer FLUSH INST INSTALLATION SID VIW ANTI-TIP BLOCK 146 FLUSH INST HIGHT** *Will be visible and should be finished to match cabinetry. **Dimension provides minimum reveals. NOT: Dashed line represents profile of unit. 25 21 TOP VIW 3 597 FLUSH INST DPTH FRONT VIW 3 603 FLUSH INST WIDTH** FINISHD CLATS* 68 nglish

DUAL FUL RANGS Dual Fuel Ranges Discover a new world of cooking the best of two worlds, actually with a Wolf dual fuel range. Topside, gas cooking in all its glory, with the fine control of dual-stacked, sealed burners and options that include the remarkable French top. Below, that marvel of culinary technology, the Wolf convection electric oven. Its two fans and four heating elements let you select from 10 cooking modes so you can choose the one precisely suited to the dish you re preparing. Ovens are self-cleaning. With a variety of range widths to choose from, kitchens large and small become gateways to the exciting new world of dual fuel cooking. All models are constructed of stainless steel and can be ordered in natural or LP gas. CONFIGURATIONS 76 cm RANG 122 cm RANG ICBDF304 ICBDF486C 91 cm RANG ICBDF486G ICBDF366 ICBDF484CG ICBDF364C ICBDF484F ICBDF364G 152 cm RANG ICBDF606CG ICBDF604CF BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 69

DUAL FUL RANGS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Dual Fuel Ranges 76 cm RANG 91 cm RANG 759 152 cm RANG 1527 929 * 911 929 * 929 * 911 122 cm RANG 749 699 613 635 664 1194 235 *929 MIN TO 983 MAX. 1216 SID VIW ALL RANGS 1419 1165 1038 937 * 929 * 70 nglish

DUAL FUL RANGS Dual Fuel Ranges BURNR RATING kw SURFAC BURNR SIM HI Large.3 4.8 Small.1 2.7 FATUR NATURAL LP Charbroiler 5.6 5.2 Griddle 5.6 5.2 French Top 4.8 4.0 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 71

DUAL FUL RANGS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information When installing against a combustible surface, a minimum 254 riser is required for a 91 cm dual fuel range with charbroiler or griddle and all 122 cm and 152 cm models. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. A Wolf pro ventilation hood is recoended with the dual fuel range. Refer to page 87 for pro ventilation. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply flush with the wall or floor and within the shaded area shown in the illustration on the following page. A separate circuit, servicing only this appliance is required. Wolf dual fuel ranges have a terminal block that allows for a 3-wire or 4-wire installation. Performance may be compromised if the electrical supply is less than 220 volts. The range is supplied with a single phase and 3-phase convertible power inlet box. The wiring diagram covering the control circuit is provided with the oven. LCTRICAL RQUIRMNTS SINGL OVN RANG SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 19 A 18 A DOUBL OVN RANG SINGL PHAS 3-PHAS Required Power Supply 220-240 V AC 50/60 Hz 380-415 V AC 50 Hz Maximum Connected Load 35 A 18 A GAS SUPPLY Installation must conform with all applicable gas codes. A gas supply line of 19 rigid pipe must be provided to the range. If local codes permit, a certified,.9 m long, 13 or 19 ID flexible metal appliance connector is recoended to connect the units ISO 7/1-14 female inlet to the gas supply line. Wolf natural gas ranges will function up to 3124 m in altitude without adjustment and LP gas ranges will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit. GAS RQUIRMNTS NATURAL GAS Supply Pressure LP GAS Supply Pressure WC 25 mbar WC 37 mbar 72 nglish

DUAL FUL RANGS Dual Fuel Range INSTALLATION 330 LOCATION OF GAS AND LCTRICAL XTNDS ON FLOOR 57 SID VIW 937 TO COOKING SURFAC 457 FRONT VIW 152 *Without ventilation hood, 914 minimum clearance countertop to combustible materials, 118 for charbroiler. NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. For island installation, 305 minimum clearance back of range to combustible rear wall above countertop. OPNING WIDTH W A 76 cm Model 762 216 91 cm Model 914 343 122 cm Model 1219 610 152 cm Model 1530 787 A 762 TO 914 TO BOTTOM OF VNTILATION HOOD* W OPNING WIDTH 254 GAS G 330 LCTRICAL 83 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 73

SALD BURNR RANGTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Sealed Burner Rangetops Wolf sealed burner rangetops incorporate all the gas cooking features of a Wolf dual fuel range. Customize your rangetop with your preferred combination of burners (from four to six), infrared griddle or charbroiler, or the remarkable French top. Compared with conventional electric elements, the infrared elements of the charbroiler and griddle are a revelation. They preheat almost instantly, distribute heat more evenly and deliver fast temperature recovery after food is placed on the surface. All sealed burner rangetop models are constructed of stainless steel and can be ordered in natural or LP gas. CONFIGURATIONS 76 cm RANGTOP 91 cm RANGTOP 122 cm RANGTOP ICBSRT304 ICBSRT364C ICBSRT364G ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F 74 nglish

SALD BURNR RANGTOPS Sealed Burner Rangetops 76 cm RANGTOP 759 91 cm RANGTOP 911 122 cm RANGTOP 1216 BURNR RATING kw 208 208 208 191 SURFAC BURNR SIM HI Large.9 4.6 Small.6 2.8 FATUR NATURAL LP Charbroiler 5.8 5.3 Griddle 5.5 4.7 French Top 4.6 4.0 724 613 664 235 699 445 318 216 SID VIW ALL RANGTOPS BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 75

SALD BURNR RANGTOPS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information The platform to support the sealed burner rangetop must include a cut-out for electrical and gas supply connections. Refer to the chart below for minimum base support. When installing against a combustible surface, a minimum 254 riser is required for 91 cm and 122 cm sealed burner rangetops with a charbroiler or griddle. Follow all minimum clearances to combustible surfaces shown in the illustration on the following page. A Wolf pro ventilation hood is recoended with the sealed burner rangetop. Refer to page 87 for pro ventilation. A downdraft can be used with model ICBSRT304. An accessory trim kit is necessary for this installation. Contact an authorized Wolf dealer for details. INSTALLATION RQUIRMNTS PLATFORM Thickness 19 BAS SUPPORT MIN 76 cm Rangetop 91 kg 91 cm Rangetop 113 kg 122 cm Rangetop 136 kg LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply within the shaded area shown in the illustration on the following page. A separate circuit, servicing only this appliance is required. LCTRICAL RQUIRMNTS lectrical Supply grounded, 220-240 VAC; 50/60 Hz Service 0.2 A Receptacle 3-prong grounding-type Power Cord 2 m GAS SUPPLY Installation must conform with all applicable gas codes. A gas supply line of 19 rigid pipe must be provided to the rangetop. If local codes permit, a certified,.9 m long, 13 or 19 ID flexible metal appliance connector is recoended to connect the units ISO 7/1-14 female inlet to the gas supply line. Wolf natural gas rangetops will function up to 3124 m in altitude without adjustment and LP gas ranges will function up to 2621 m. If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit. GAS RQUIRMNTS NATURAL GAS Supply Pressure LP GAS Supply Pressure WC 25 mbar WC 37 mbar 76 nglish

SALD BURNR RANGTOPS Sealed Burner Rangetop INSTALLATION 330 SID VIW 610 MAX PLATFORM 191 OPNING HIGHT 457 152 762 TO 914 TO BOTTOM OF VNTILATION HOOD* W OPNING WIDTH PLATFORM PLATFORM TOP VIW 102 FRONT VIW BACK WALL G 406 LCTRICAL AND GAS *Without ventilation hood, 914 minimum clearance countertop to combustible materials, 118 for charbroiler. NOT: Shaded area above countertop indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. lectrical and gas supply located through bottom of platform. For island installation, 305 minimum clearance back of range to combustible rear wall above countertop. OPNING WIDTH 76 cm Model 762 91 cm Model 914 122 cm Model 1219 W BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 77

COOKTOP HOODS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Cooktop Ventilation Hoods The new generation of Wolf cooktop ventilation hoods feature three new looks black, stainless and glass. Brilliant LD lighting illuminates your cooking surface while powerful multi-speed blowers whisk away smoke and odors. Dishwasher-safe filters can be removed easily for cleaning. Wall-mount and island hoods are crafted of stainless steel. COOKTOP VNTILATION HOODS BLACK ICBVW30B WALL ICBVW36B WALL ICBVW45B WALL ICBVI42B ISLAND STAINLSS ICBVW30S WALL ICBVW36S WALL ICBVI42S ISLAND GLASS ICBVW36G WALL ICBVW45G WALL ICBVI45G ISLAND 78 nglish

COOKTOP HOODS Cooktop Ventilation Hoods WALL HOODS BLACK 298 W WIDTH 740 TO 997 * 57 *1248 to 1505 with accessory flue extension. WIDTH ICBVW30B ICBVW36B ICBVW45B ISLAND HOOD BLACK 349 540 591 TO 813 * 57 600 489 260 286 1067 673 *1175 to 1397 with accessory flue extension. W 762 914 1143 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 79

COOKTOP HOODS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Cooktop Ventilation Hoods WALL HOODS STAINLSS 298 W WIDTH 740 TO 997 * 152 *1248 to 1505 with accessory flue extension. WIDTH ICBVW30S ICBVW36S ISLAND HOOD STAINLSS 349 591 TO 813 * 152 540 559 600 260 286 1067 673 *1175 to 1397 with accessory flue extension. W 762 914 80 nglish

COOKTOP HOODS Cooktop Ventilation Hoods WALL HOODS GLASS 298 W WIDTH 740 TO 997 * 57 *1248 to 1505 with accessory flue extension. WIDTH ICBVW36G ICBVW45G ISLAND HOOD GLASS 349 540 591 TO 813 * 57 489 600 260 286 1143 673 *1175 to 1397 with accessory flue extension. W 914 1143 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 81

COOKTOP HOODS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information Wolf cooktop ventilation hoods are recoended for use with Wolf induction, electric and gas cooktops and modules. For ranges and rangetops, a Wolf pro ventilation hood is recoended. These hoods have a telescopic chimney flue. A flue extension is available through an authorized Wolf dealer. Installation of the cooktop hood should be 762 to 914 from the bottom of the hood to the countertop. Wall and island hoods require an internal or remote blower assembly, avail able through an authorized Wolf dealer. Refer to ventilation suggestions on page 91. Cooktop hoods have a vertical discharge with 152 round duct. Consult a qualified HVAC professional for specific installation and ducting applications. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). For wall hoods, locate the electrical supply within the shaded area shown in the illustration below. For island hoods, locate the electrical supply on the ceiling inside the top of the hood. A separate circuit, servicing only this appliance is recoended. LCTRICAL RQUIRMNTS lectrical Supply Service 457 lectrical location all wall hoods. 762 TO 914 BOTTOM DG TO COUNTRTOP 220-240V, 50 Hz 220V, 60 Hz 419 W 82 nglish

DOWNDRAFT SYSTMS Downdraft Ventilation Constructed of heavy duty stainless steel, the Wolf downdraft rises from the countertop to whisk away odor and smoke into stainless steel, mesh filters and can be lowered beneath the countertop when not in use. Downdrafts integrate perfectly with transitional induction cooktops, gas cooktops and some modules, they can also be installed with certain sealed burner rangetops. DOWNDRAFTS ICBDD30 ICBDD45 ICBDD36 Downdraft DIMNSIONS W DOWNDRAFT WIDTH 330 A CHIMNY WIDTH 381 330 356 730 51 254 64 172 60 NOT: Shown with front mounted internal blower with 152 round discharge, dashed line represents rear mount. WIDTH W A ICBDD30 762 673 ICBDD36 914 826 ICBDD45 1143 978 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 83

DOWNDRAFT SYSTMS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Planning Information Wolf downdrafts can be installed with most Wolf cooktops, but are not compatible with contemporary induction cooktops and the grill, steamer and fryer modules. Downdrafts can be installed with sealed burner rangetop model ICBSRT304. An accessory trim kit is necessary for this installation. Contact an authorized Wolf dealer for details. The remote-mounted control module must be located within 2.7 m of the downdraft assembly and a minimum 76 from the edge of the cooktop cut-out. Internal and remote blowers are available through an authorized Wolf dealer. Refer to ventilation suggestions on page 91. Internal blowers include a 152 round discharge and can be front or rear mounted. It can be discharged in any direction by rotating the blower box. Remote blowers include a 254 discharge and can be discharged from the front or rear. Consult a qualified HVAC professional for specific installation and ducting applications. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recoended and may cause interruption of operation. Certain installations may require that the electrical supply be placed in an adjacent cabinet. LCTRICAL RQUIRMNTS lectrical Supply Service Receptacle 220-240 V AC, 50 Hz 220 V AC, 60 Hz 415 W grounding-type (earthed) 84 nglish

DOWNDRAFT SYSTMS Downdraft INSTALLATION WITH COOKTOP 210 * SID VIW 540 68 *152 back from countertop cut-out when internal blower is rear mounted. COOKTOP CUT-OUT FRONT VIW NOT: Internal blower 152 round, side, rear or bottom discharge. Remote blower 254 round, rear discharge. Centerline indicates center of downdraft cut-out. CUT-OUT WIDTH ICBDD30 ICBDD36 ICBDD45 W 699 851 1003 W DOWNDRAFT CUT-OUT WIDTH 540 TOP VIW 210 * 594 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 85

DOWNDRAFT SYSTMS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Downdraft INSTALLATION WITH SALD BURNR RANGTOP 210 * SID VIW 483 PLATFORM DPTH 540 68 *152 back from countertop cut-out when internal blower is rear mounted. W DOWNDRAFT CUT-OUT WIDTH TOP VIW FRONT VIW 210 * RANGTOP OPNING NOT: Internal blower 152 round, side, rear or bottom discharge. Remote blower 254 round, rear discharge. Centerline indicates center of downdraft cut-out. CUT-OUT WIDTH ICBDD30 ICBDD36 W 699 851 540 594 86 nglish

PRO VNTILATION Pro Ventilation Hoods Professional heritage shines through in Wolf professionalstyle ventilation. xteriors are heavy-duty, welded stainless steel, so finely hand-finished that they appear seamless. Pro wall hoods are available in a variety of widths. Stainless steel baffle filters and halogen lighting extend the professional look and back it up with pro-level performance. All pro ventilation hoods are crafted of stainless steel. PRO HOODS WALL HOODS 61 cm 69 cm DP BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 87

PRO VNTILATION VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Pro Hoods 61 cm DP WALL HOOD 69 cm DP WALL HOOD WIDTH W WIDTH W WIDTH 457 457 61 cm DP WALL HOOD W 76 cm, 91 cm, 107 cm, 122 cm, 152 cm 69 cm DP WALL HOOD W 76 cm, 91 cm, 107 cm, 122 cm, 152 cm 305 305 610 686 102 102 88 nglish

PRO VNTILATION Planning Information Pro ventilation hoods are recoended for use with all Wolf cooking appliances. Wall hoods should be at least as wide as the cooking surface. For optimal performance in wall hood applications, a pro 69 cm deep wall hood is recoended for use with ranges and rangetops with a charbroiler or griddle. Installation of the hood should be 762 to 914 from the bottom of the hood to the countertop. Pro hoods are shipped without a blower assembly. Internal and remote blowers are available through an authorized Wolf dealer. The blower will vary in size and is dictated by the cooking unit, volume of air and length of the duct run. Refer to ventilation suggestions on page 91. Pro hoods accoodate a 254 round duct and have a vertical discharge. For the 61 cm and 69 cm deep wall hoods, a horizontal discharge kit is available through an authorized Wolf dealer. Consult a qualified HVAC professional for specific installation and ducting applications. Optional stainless steel duct covers in a variety of heights are available for pro wall hoods through an authorized Wolf dealer. LCTRICAL Installation must comply with all applicable electrical codes and be properly grounded (earthed). Locate the electrical supply within the shaded area shown in the illustration on the following page. Allow a minimum 305 electrical cable for connection. A separate circuit, servicing only this appliance is required. LCTRICAL RQUIRMNTS lectrical Supply 220-240V, 50Hz 220V, 60Hz Service 1.9A RCIRCULATING INSTALLATION 61 cm and 69 cm deep wall hoods with an internal blower (1014 CMH or less), 76 cm and 91 cm widths only, can be used in a non-ducted application with a recirculating filter. In this installation, kitchen air is purified through filters and returned as clean air into the room. A recirculation kit, available through an authorized Wolf dealer is required. BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 89

PRO VNTILATION VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Installation 61 cm 69 cm DP WALL HOODS 127 762 TO 914 BOTTOM DG TO COUNTRTOP 152 90 nglish

VNTILATION SUGGSTIONS Blower Assemblies For Wolf ventilation hoods and downdrafts that do not include a blower assembly, an internal or remote blower assembly must be selected to accoodate the cooking appliance, CMH requirements and homeowner preferences. Internal and remote blowers are avail able through an authorized Wolf dealer. 718 394 254 DIAMTR 356 629 527 622 121 749 375 254 DIAMTR 257 559 Ventilation suggestions on the following pages provide Wolf product CMH and blower options for each ventilation hood and downdraft. Refer to the illustrations below for dimensions of Wolf remote blowers. Installation instructions shipped with each Wolf ventilation product provide detailed specifications. 1528 CMH RMOT 2028 CMH RMOT 2535 CMH RMOT 457 254 749 184 749 375 254 DIAMTR 264 635 533 254 749 184 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 91

VNTILATION SUGGSTIONS VNTILATION RANGS RANGTOPS COOKTOPS COFF BUILT-IN OVNS Wolf Product CMH CMH MODL COOKTOP HOOD DOWNDRAFT PRO HOOD COOKTOP MODUL ICBCI152TF/S ICBCG152TF/S 900 900 1014 ICBSM15TF/S ICBGM15TF/S 900 1014 ICBTM15TF/S ICBMM15TF/S 900 900 1014 ICBCI243C/B 900 1014 ICBCI304TF/S ICBCI304T/S 900 900 1014 ICBCI304C/B 900 1014 ICBCG304T/S ICBCG304P/S 900 900 1014 ICBCI365TF/S ICBCI365T/S 900 900 1014 ICBCI365C/B 900 1014 ICBCG365T/S ICBCG365P/S 900 900 1014 ICBCG365C/S 900 1014 DUAL FUL RANG ICBDF304 ICBDF366 1014 ICBDF364C ICBDF364G 1528 ICBDF486C ICBDF486G ICBDF484CG ICBDF484F 1859 ICBDF606CG ICBDF604CF 1859 SALD BURNR RANGTOP ICBSRT304 900 1014 ICBSRT364C ICBSRT364G 1528 ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F 1528 92 nglish

VNTILATION SUGGSTIONS Wolf Ventilation Blower Options BLOWR INTRNAL RMOT CMH 900 1014 1528 1859 1528 2028 2535 COOKTOP HOOD ICBVW30B ICBVW36B ICBVW45B ICBVI42B ICBVW30S ICBVW36S ICBVI42S ICBVW36G ICBVW45G ICBVI45G DOWNDRAFT ICBDD30 ICBDD36 ICBDD45 PRO 61 cm DP WALL HOOD ICBPW362418 ICBPW482418 PRO 69 cm DP WALL HOOD ICBPW302718 ICBPW362718 ICBPW422718 ICBPW482718 ICBPW602718 BUILT-IN OVNS COOKTOPS COFF RANGS RANGTOPS VNTILATION wolfappliance.com 93

Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design, are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries. 94 nglish

Wolf Appliance International Limited Warranty FOR RSIDNTIAL US FULL TWO YAR WARRANTY* For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. LIMITD THIRD THROUGH FIFTH YAR WARRANTY For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours. For more information regarding your Wolf product warranty, contact your authorized Wolf dealer. Warranties must comply to all country, state, city, local and or ordinance. *Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.

W O L FA P P L I A N C. C O M