Printing works and warehouse area Press Lane, 21 Ink Street, Presstown. PR3 3SS Postcode: Assessor signature:

Similar documents
Record of fire safety risk assessment

Fire Risk Assessment - HMO (including accommodation with integrated fire systems)

Fire Risk Assessment. Assessor: Brian Urquhart & Valerie Newton Date 09/11/2016. The Ashvale Fish Restaurant Trinity Rd Brechin DD9 6BE

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

FIRE RISK ASSESSMENT Self Assessment

Assessment details. You can use this form to record a fire safety assessment of simple premises. Address. 123 Station Rd Brigadoon

Fire Risk Assessment Case Study

5 Key Stages to Risk Assessment

Fire Risk Assessment

Fire risk management plan. MH/05/Revised/06/17

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

Fire Safety Checklist

Fire Risk Assessment

Fire Risk Assessment Safety Checklist

FIRE SAFETY POLICY Revised March 2013

FIRE SAFETY RISK ASSESSMENT

Byker Various post codes. Your Homes Newcastle Health and Safety (fire) Officer Date of Fire Risk Assessment 18 th February nd October 2014

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Fire Safety. A TUC guide for trade union activists

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

FIRE RISK ASSESSMENT

A basic guide to... Fire Safety for Scout Premises

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Fire Risk Assessment (FRA) Checklist

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

- CONSTRUCTION FIRE SAFETY STANDARDS

Fire Risk Assessment Report - Initial. 23 Newhaven Court, Nantwich, CW5 5GT

Arbour House. Fire Policy and Procedures

SPONSORED BY SOLUTIONS FIRE SAFETY AN INTRODUCTION

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

FIRE PROCEDURES 1. APPOINTMENTS

- CONSTRUCTION FIRE SAFETY STANDARDS

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

Fire Safety Policy 2018/19

FIRE RISK ASSESSMENT

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Millfield Schools Fire Risk Prevention Policy

Why is this important?

If there are more than ten people working other than on the ground floor,

1.0 INTRODUCTION 2.0 FIRE SAFETY TRAINING 3.0 FIRE SAFETY RISK ASSESSMENT

Fire Safety Policy Date: 0

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL

Fire Risk Management Policy. UK September 2017

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

CYNGOR SIR POWYS COUNTY COUNCIL

FIRE SAFETY RISK ASSESSMENT

NOTTINGHAM CITY HOMES

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

FIRE SAFETY AWARENESS

UNIVERSITY OF OXFORD FIRE RISK ASSESSMENT

Fire Risk Assessment 2017

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Fire Risk Assessment Keys Meadow Primary School

FIRE SAFETY AND PREVENTION POLICY

Fire Risk Assessment 2016

Fire Risk Assessment Guidance

Fire Safety Awareness Workbook

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Risk Assessment

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report

H&S Forum. Fire Safety Policy Glascote Academy

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

FIRE SAFETY PRACTICES AND PROCEDURES

fire risk assessment For use by landlords of small premises Premises Address

Wellsprings Primary School. Fire Emergency Evacuation Plan

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Management Standard: Fire Safety

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

Emergency Evacuation Plan South Patterson Building (SPB)

LYHA Fire Safety Policy

NOT PROTECTIVELY MARKED. Fire Legislation

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Fun Foundations Day Nursery Fire Safety Risk Assessment

ST Edmunds Scout and Guide Headquarters. Fire Risk Assessment

A PRACTICAL FIRE SAFETY GUIDE FOR SMALL SELF-CATERING PREMISES

FIRE RISK ASSESSMENT

EVACUATION PROCEDURES IN EDUCATION PREMISES

Fire Safety Workbook

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

Fire Safety in Communal Areas Policy

Fire Safety Risk Assessment Large Premises

LOVE THE OCEANS 2018 EXPEDITIONS FIRE RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Model Fire Risk Assessment

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

Fire Prevention STANDARD. LME-12: Uen Rev A

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire Safety Risk Assessment. Healthcare Premises

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

FIRE RISK ASSESSMENT CHECKLIST

Transcription:

RECORD OF FIRE SAFETY RISK ASSESSMENT Building Name & Use: Address: Printing works and warehouse area Press Lane, 21 Ink Street, Presstown. PR3 3SS Postcode: Name of person(s) with fire safety duties: Name and contact details of assessor: Mr T Jones (Managing ) Mr T Jones (Managing ) as above Date of Assessment: 3 rd April 2011 Assessor signature: STEP 1 IDENTIFY FIRE HAZARDS (see list on back page) Sources of ignition, e.g. electrical fittings, smoking, heating, open flames Electrical appliances, printing machinery, dryers. Gas heating system (covered by maintenance contract). LPG powered forklift truck (covered by maintenance contract). Hot works. Smoking. Deliberate fire setting. Sources of fuel, eg, furniture, textiles and fabrics Large quantities of paper and flammable liquids. Sources of oxygen, eg, ventilation Normal ventilation in office area. Roller shutter door in warehouse area. STEP 2 IDENTIFY PEOPLE AT RISK List all persons potentially at risk from fire, including employees, tenants, visitors and contractors At time of assessment 18 employees, 12 in warehouse and 6 in office. Working hours from 0800 to 1800. (Occasionally requirement to work late). All employees familiar with the area, none have any impairments that need any special consideration in relation to this assessment. Occasionally contractors and maintenance staff would carry out inspections and maintenance. 1 of 7

STEP 3 EVALUATE, REMOVE, REDUCE AND PROTECT FROM RISK Likelihood of a fire starting Printing machinery can become very hot during high production times. Lack of maintenance to dryers could lead to increased fire risk. Flammable liquids stored in lockable cabinet. Only small amounts used at a time, although soaked rags kept beside machinery are not being disposed of properly. Some hot works carried out by contractors on an intermittent basis, no procedures in place to manage this work. Evaluate the risk to people Some pallets awaiting uplift were partially blocking the rear fire exit. Areas at bottom of fire escape stairs being used to store paper and cardboard boxes. Some local knowledge of deliberate fire setting in area. Site has uncovered skips but as they are situated well away from the building, reduces potential for fire spread. STEP 4 RECORD, PLAN, INFORM, INSTRUCT AND TRAIN Fire Safety Policy (Further guidance on Fire Safety Policy in Part Two of guide) No fire management policy. A No smoking policy in place. Smoking shelter approx 10 metres from building. Emergency fire action plan Staff fire evacuation procedures are in place but no record of last fire drill was evident. Fire safety information and training Staff given general fire safety training on induction, but no refresher training being carried out. Staff not trained in use of extinguishers. 2 of 7

STEP 4 RECORD, PLAN, INFORM, INSTRUCT AND TRAIN (continued) Fire Drills No records of staff evacuation drills are being kept. Maintenance of safety measures (For further guidance see Appendix A of relevant Risk Assessment guide) Fire alarm system installed but no records of testing and maintenance. Fire exit routes not clearly indicated with signs. Sufficient provision of fire extinguishers but some not wall mounted or on suitable stands. Emergency lighting not provided in rear fire escape stairway. Spare LPG cylinder kept in external locked cage. Sufficient provision of escape routes, however two existing doors opening into main fire escape staircase are not fire resisting. Recording information and keeping records All electrical appliances inspected and tested in 2010. Records kept and available for heating system maintenance. Records kept and available for forklift maintenance. Records kept and available for maintenance of printers and dryers. Staff training records available for induction but none available for refresher training. No evidence of fire evacuation drills. 3 of 7

The assessor completing the following section should prioritise remedial measures, based on the level of risk. Priority ratings and suggested timescales: Low (L) 3 6 months Medium (M) Up to 3 months (H) As soon as possible STEP 4 ACTION POINTS Priority Person responsible Completion date Introduce system for hot working by contractors. Consider hot work permit system. Implement inspection and maintenance programme for dryers. Review storage of flammable liquids & disposal of soaked rags. Clear any pallets, paper & cardboard from fire exits and keep area clear at all times. A Fire Management policy is required to identify persons with responsibilities. Fit two fire resisting doors with self closures. Managing Provide emergency lighting as required to rear escape stairway. Medium July 2011 Note: Please print additional sheet if required 4 of 7

The assessor completing the following section should prioritise remedial measures, based on the level of risk. Priority ratings and suggested timescales: Low (L) 3 6 months Medium (M) Up to 3 months (H) As soon as possible STEP 4 ACTION POINTS Priority Person responsible Completion date Provide fire exit signage to clearly identify exit routes. Medium Managing July 2011 Carry out and record details of regular tests of fire alarm. Carry out and record details of fire evacuation drills to determine suitability of arrangements. Provide refresher training to all staff to bring to their attention the fire precautions and evacuation procedures for the premises. Keep records of training. Managing Provide wall mounts or suitable stands for fire extinguishers. Medium July 2011 Consider training some employees in the use of fire extinguishers. Medium Managing July 2011 Note: Please print additional sheet if required 5 of 7

Review the fire risk assessment if there is a reason to suspect it is no longer valid or if there has been a significant change in the matters to which it relates. Reference Part One of the relevant sector specific, fire safety risk assessment guide STEP 5 ASSESSMENT REVIEW Review date April 2012 Review by Reason for review: Annual review. Outcomes of review 6 of 7

FIRE SAFETY RISK ASSESSMENT GUIDES The following premises guides are available from Northern Ireland Fire & Rescue website www.nifrs.org. Follow the Make sure you re Fire Safe link and go to Guidance Documents. These can be downloaded from the Communities and Local Government section. 1 Offices and Shops; 2 Factories and Warehouses; 3 Sleeping Accommodation; 4 Residential Care Premises; 5 Educational Premises; 6 Small and Medium Places of Assembly; 7 Large Places of Assembly; 8 Theatres, Cinemas and Similar Premises; 9 Open Air Events and Venues; 10 Healthcare Premises; 11 Transport Premises and Facilities; 12 Animal Premises and Stables; 13 Means of Escape for Disabled People (Supplementary Code); and 14 Reducing the Number of False Alarms from Detection and Alarm Systems. Adapted from original materials created by the Scottish Centre for Healthy Working Lives and the Scottish Fire and Rescue Services 7 of 7