An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

Similar documents
A Literature Review On Heat Exchanger Air Side Fouling In Heating, Ventilation And Airconditioning

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Design and performance evaluation of vacuum cleaners using cyclone technology

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Evaluation the Effect of Washing on the Heat Transfer Capacity and Air-Side Flow Resistance of Air Cooled Condensers

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Purdue e-pubs. Purdue University

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Purdue e-pubs. Purdue University. Ian H. Bell Purdue University. Eckhard A. Groll Purdue University

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

The Effects of Hydrophilicity on Water Drainage and Condensate Retention on Air-Conditioning Evaporators

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Air-Cooled Heat Exchanger Performance for R410A

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Sub-Critical Operation of the CO2 Expander/ Compressor

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Low GWP Refrigerants for Air Conditioning Applications

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Experimental Investigation of Purification Function of Air Conditioner

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Efficiency of Non-Azeotropic Refrigerant Cycle

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Effect of Inclination Angle on the Air-Side Performance of Aluminum Parallel Flow Heat Exchangers Under Wet Conditions

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Study of R161 Refrigerant for Residential Airconditioning

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

The Use Of Attic Space For Cooling and Dehumidification

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

R32 Compressor for Air conditioning and Refrigeration applications in China

High Efficiency R-134a Compressor for Domestic Refrigerator

Development of HFC-134a Compressor for Domestic Refrigerator

Key words: heat exchanger, fouling, pressure drop

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Screw Compressor For Ammonia-Water Heat Pump Lubricated By The Process Mixture

Performance of CO2 Cycles with a Two-Stage Compressor

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Experimental and Numerical Study on a Dryexpansion Shell-and-Tube Evaporator Used in Wastewater Source Heat Pump (WWSHP)

Real Time Upright Freezer Evaporator Performance Under Frosted Conditions

Compressor Capacity Control

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Developing Two-Phase Flow Distribution in Horizontal Headers With Downward Minichannel-Branches

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Leakage of Mildly Flammable Refrigerants into a Room

Heat transfer property of refrigerant-oil mixture in a flooded evaporator: The role of bubble formation and oil retention

Experimental Study of Two-phase Seperators for Vapor Compression Systems in Household Appliances

Evaluation of Mechanical Dehumidification Concepts (Part 2)

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

A New Control Approach for a Direct Expansion (DX) Air Conditioning (A/C)System with Variable Speed Compressor and Variable Speed Supply Fan

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners Youngchull Ahn Pusan National University Seongir Cheong Pusan National University Youngman Jung Pusan National University JaeKeun Lee Pusan National University Follow this and additional works at: http://docs.lib.purdue.edu/iracc Ahn, Youngchull; Cheong, Seongir; Jung, Youngman; and Lee, JaeKeun, "An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners" (2006). International Refrigeration and Air Conditioning Conference. Paper 818. http://docs.lib.purdue.edu/iracc/818 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

An Experimental Study of the Air-side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners Young Chull AHN* 1, Seong-Ir CHEONG 2, Young Man JUNG 2, Jae Keun LEE 2 R020, Page 1 1 Research Institute of Mechanical Technology, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan, 609-735, Korea, Tel: +82-51-510-2492, Fax: +82-51-512-9835, E-mail: ycahn@pusan.ac.kr 2 School of Mechanical Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan, 609-735, Korea Tel: +82-51-510-2455, Fax: +82-51-512-5236, E-mail: jklee@pusan.ac.kr ABSTRACT An experimental study is conducted to investigate the chronological performance variation such as pressure drop across a heat exchanger and cooling capacity due to the air-side particulate fouling of fin-and-tube heat exchangers for air conditioner evaporators used. 30 samples of air conditioners used in the field such as inns, restaurants, and offices are collected in chronological used order. This study is intended to provide factual long-term fouling data under actual operating conditions. It is found that the important parameters to influence the fouling of heat exchangers are the concentration and size of indoor pollutants, the filter efficiency, hydrophilicity of fin surfaces and fin spacing. The pressure drop of heat exchangers increases due to the deposition of indoor pollutants larger than 1 μm in size and increases up to 44% in the samples used for 7 years. The air-side particulate fouling degrades the cooling capacity by 10-15% in the samples. 1. INTRODUCTION Fouling may be defined as the accumulation of unwanted deposits on the surfaces of heat exchangers. The presence of these deposits reduces the heat transfer, increases the pressure drop across a heat exchanger, and increases the maintenance cost of cleaning. The foulant may be crystalline, biological material, the products of chemical reactions including corrosion or particulate matter (Bott, 1995). Fouling of heat exchangers used in heating, ventilating, and air conditioning (HVAC) system is important because of their widespread use in commercial, residential and industrial HVAC applications. Indoor and outdoor air contaminants foul these heat exchangers. The air-side fouling of air conditioners, the deposition of indoor dusts and other particulate matters on evaporator heat exchangers, increases system pressure drop, decreases system air flow and air conditioner performance. Moreover because the fouling materials act as bacteria cultivator, the fouling must be prevented and eliminated in the indoor heat exchangers in the HVAC applications (Ahn et al., 2002). Air-side particulate fouling can be described as the accumulation of solid particles suspended in the air onto a heat transfer surface. In HVAC system, dust particles carried forward in the air are potential foulants for the heat exchangers. The theory associated with the transport of particles towards and onto surfaces is extensive and complex (Epstein, 1988). Transport of particles to the heat exchanger surfaces in the particulate fouling can occur by Brownian or laminar diffusion, turbulent diffusion, gravitational settling, inertial impaction, thermophoresis, or electrophoresis. In actual practice, two or more of these mechanisms will probably occur simultaneously. The sizes of particles have a large influence on the dominant mechanism. For instance, very small particles would be expected to be subject to Brownian diffusion and turbulent diffusion whereas the larger particles due to their mass would move under inertia impaction. Having arrived at the surface the particle must stick or adhere if it is to be regarded as part of the foulant layer residing on the surface. The purpose of this study is to investigate the chronological performance variation such as pressure drop and cooling capacity due to the air-side particulate fouling of fin-and-tube heat exchangers for air conditioner evaporators used.

R020, Page 2 30 samples of air conditioners used in the field such as inns, restaurants, and offices are collected in chronological used order. The psychrometric calorimeter for measuring the cooling capacity and pressure drop of heat exchangers in the air conditioners is used in this study. 2. EXPERIMENTAL Fig. 1 shows a schematic diagram of the psychrometric calorimeter (3S System, 7,000 8,200 3,000 mm3 ) for measuring the pressure drop and the cooling capacity of HVAC heat exchangers. It consists of a constant temperature and humidity chamber, a wind tunnel for measuring the performance of heat exchangers, an isothermal water bath and a control panel. The constant temperature and humidity chamber is composed of a chiller, a heater, a humidifier, and an air-handling unit. It keeps the temperature and the humidity inside the calorimeter constant. The dry and the wet bulb temperatures inside the calorimeter are set at 27 and 19.5, respectively, based on the Korean Standard Air Conditioners (KS C 9306, 2002). The wind tunnel, (310 210 mm2 for window-type and 750 210 mm2 for wall-mounted type of air conditioners), is composed of the heat exchanger for testing, two couples of dry and wet bulb thermometer, an orifice and a suction fan. Two couples of dry and wet bulb thermometer measure the air temperature and humidity upstream and downstream of the test heat exchanger to obtain the air-side enthalpy variation. The air flow rate is monitored by the pressure drop of the orifice(65 ~ 150 mm in diameter) and can be controlled by adjusting the electric frequency of the suction fan motor. CHILLER/HEATER HUMIDIFIER TURBO FAN AIR HANDLING UNIT ÄP TEST HEAT EXCHANGER AIR ORIFICE AIR TDO TWO AIR SAMPLING UNIT TDI TWI WIND TUNNEL CONDENSATE ISOTHERMAL WATER BATH PUMP FLOW METER DATA ACQUISITION SYSTEM CONTROL PANEL Figure 1: Schematic diagram of the psychrometric calorimeter for measuring the cooling capacity and the pressure drop of heat exchangers in the air-conditioner. The isothermal water bath contains distilled water as a working fluid and the constant temperature (5 ) water is supplied by pump to the heat exchanger at the flow rate of 430 kg/hr. The water-side enthalpy variation can be calculated because the temperature of the return water changes due to the heat exchange with the air stream. The deviation between the values of the air-side and the water-side enthalpy for measuring the cooling capacity of the heat exchanger maintains within ±3% in order to stabilize the equipment and to give reliability. The heat exchanger used in this study is the evaporator of the air conditioner which consists of a compressor, a condenser, an expansion device, and the evaporator. The evaporator heat exchangers used in this study is the finand-tube types with 15 ~ 18 fins per inch and the diameter of tubes is 7 ~ 9 mm. Table 1 shows specifications of the evaporators tested in this study. The face velocity of the heat exchanger is set at 1 m/sec for measuring the pressure drop. On the other hand, the cooling capacity is measured at the initial pressure drop of the new heat exchanger. In that condition for measuring pressure drop across the heat exchanger, the face velocity is slightly slower than 1 m/sec. That is, the higher the

R020, Page 3 pressure drop, the slower the face velocity to have the same pressure drop as the initial value of the clean heat exchanger. Table 1: Specifications of the test heat exchangers used Fin shape Fins/Inch Tube Diameter Arrangement 3 Slitted plate 18 7 mm Staggered 4 Slitted plate 18 7 mm Staggered 6 Slitted plate 18 7 mm Staggered 7 Slitted plate 18 7 mm Staggered 9 Slitted plate 18 7 mm Staggered 13 Louvered plate 16 9 mm Staggered 14 Louvered plate 16 9 mm Staggered 15 Plane plate 15 9 mm Staggered 3. RESULTS AND DISCUSSIONS 3.1 Analysis of fouling particles Fig. 2 shows photographs of the fouled evaporator heat exchangers used in seaside inns for 6 and 14 years, respectively. The fouling materials consist of particulates and fibers. The particulates are mainly originated from indoor dusts and the fibers are separated from clothes, bedclothes, papers, and fur of pets. In general, the evaporator heat exchanger in the air conditioner repeats wet and dry cycles. The wet cycle ( ON mode of air conditioners) means the operation that the evaporator has condensed water on the fin surfaces of the heat exchanger by the circulation of refrigerants, while the dry cycle (no refrigerant circulation and fan operation only) means the operation that the evaporator doesn t have condensed water on the heat exchanging surfaces. When the air conditioner repeats wet and dry cycles, the fouling particles agglomerate with adjacent particles and grow by condensation. (a) (b) Figure 2: Photographs of fouled evaporator heat exchangers. (a) Used for 6 years, (b) Used for 14 years The size of the fouling particles on the evaporator heat exchangers used in the office, the restaurant and the inn is analyzed using a particle analyzer (API, Aerosizer). The mean sizes of the fouling particles collected in the office, the restaurant, and the inn are 6.6, 9.8, and 20.9 μm, respectively. The particle size of the inn sample is the largest one because the air conditioner installed in the inn has been exposed to somewhat high dust concentration and particle agglomeration due to long operation time. The air conditioners sampled from the inn are window-type, while those of the office and the restaurant are wall-mounted type. Actually the window-type air conditioner is installed 1.5 m above the floor and the wall-mounted air conditioner is installed 2 ~ 2.5 m above the floor. There exists a significant difference of the suspended dusts concentration due to the human activity. Thatcher and Layton (1995) investigated deposition and suspension of particles within a residence and showed that even light activity can have a significant impact on the concentration of airborne particles with diameters greater than 5 μm. These particle sizes also contribute the majority in the size distribution of indoor air quality based on particle mass. Therefore the

R020, Page 4 window-type air conditioner is exposed to relatively high dust concentration and shows the largest size of fouling particles. 3.2 Chronological variations of pressure drop Fig. 3 represents chronological variations for the pressure drop across the evaporator heat exchanger in airconditioners used in the seaside inn. For the wet cycle ( ON mode with refrigerant circulation), the pressure drop increases up to 145% compared with the initial pressure drop and shows the asymptotic increase. The pressure drops in the wet cycle are higher than those of dry cycle (no refrigerant circulation and fan operation only). It is believed that the water condensates formed on the fin and tube surfaces by condensing during the wet cycle result in flow resistances. 150 Variations of pressure drop (%) 140 130 120 110 Wet Cycle Dry Cycle Dry/Wet bulb : 27 É/19.5 É Face velocity : 1 m/sec 0 1 2 3 4 5 6 7 8 9 Figure 3: Chronological variations for the pressure drop of evaporator heat exchangers in air-conditioners used in the seaside inn (wet cycle: ON mode of air conditioners, dry cycle: no refrigerant circulation and fan operation only). Table 2 shows variations of static contact angles in the fin surface of heat exchangers in the chronological order. Contact angle of fin surfaces influence the cooling capacity and pressure drop across the heat exchanger. Most heat exchangers of air conditioner evaporators have hydrophilic fin surfaces at the beginning due to hydrophilic coating. If the fin has hydrophilic surface, the condensed water flows down freely and the increase of the pressure drop across the heat exchanger can be minimized. However, the hydrophilic coating cannot sustain the hydrophilicity for long time due to fouling. The initial contact angle is 20 ~ 30 and shows good hydrophilicity, but the hydrophilicity becomes weak by the repetition of wet and dry cycle. Finally, the contact angle of fin surfaces increases up to. Table 2: Static contact angles of the fin surfaces in the evaporator heat exchanger used Type Static contact angle( ) Initial - 20 ~ 30 3 Window 47 ~ 67 6 Window 81 ~ 88 6 Wall-mounted 61 ~ 64 7 Window 63 ~ 78 9 Wall-mounted 58 ~ 72 13 Wall-mounted 53 ~ 60 14 Window 45 ~ 65 15 Wall-mounted 45 ~ 81 * Window-type collected from the seaside inn. * Wall-mounted type collected from the restaurant, office, and residence.

R020, Page 5 Fig. 4 shows the test summary of chronological variations for the pressure drop across the evaporator heat exchanger taking account into the decrease of hydrophilicity in the fin surface. The square symbols represent the pressure drop across the heat exchanger used for a few years divided by the pressure drop of the heat exchanger at the initial condition. The circle symbols represent the pressure drop across the used heat exchanger divided by the one across the heat exchanger cleaned from the used heat exchanger. Therefore, data of square symbols mean the effects of the particulate fouling and the decrease of hydrophilicity due to the repeated use in the field application, while data of circle symbols mean only the particulate fouling effects. The pressure drop due to the decrease of hydrophilicity in the fin surface contributes more than 10 ~ 30% of the total pressure drop. For preventing the deterioration of evaporator heat exchangers, the longer lasting hydrophilicity as well as the prevention of fouling is very important. 150 Variations of pressure drop (%) 140 130 120 110 70 Face velocity : 1 m/sec Fouling + Decrease of hydrophilicity 60 Fouling only 50 0 2 4 6 8 10 12 14 16 Figure 4: Test summary of chronological variations for the pressure drop of evaporator heat exchangers in airconditioners with and without the decrease of hydrophilicity. 3.3 Chronological variations of cooling capacity Fig. 5 shows the summary of chronological variations for the cooling capacity of evaporator heat exchangers in the air-conditioner at the face velocity of 1 m/sec being a representative velocity for the air conditioner initially. As explained in Fig. 4, data of the square symbols represent the cooling capacity due to the effect of particulate fouling in addition to that of hydrophilicity decrease. Data of the circle symbols represent the effect of particulate fouling only. The variations of the cooling capacity show no tendency even somewhat large deviations from %. It is believed that some amounts of particulate deposits on the surface of fins enhance the cooling capacity due to the increase of flow turbulence intensity. Even the dropwise condensations, formed by the decrease of hydrophilicity, have the larger heat transfer capacity than filmwise condensation when the pressure drop is neglected and the flow rate is constant [Incropera and DeWitt, 1996]. Therefore the decrease of the hydrophilicity in the fin surfaces doesn t affect directly to the decrease of cooling capacity unless the air flow rate reduces. However, in case the deposits become thick enough to change substantially the flow pattern across the fins, the particulate fouling degrade the cooling capacity due to increasing the heat resistance of heat transfer.

R020, Page 6 Cooling capacity (%) 110 105 95 85 75 70 V = Constant (1m/sec) Fouling + Decrease of Hydrophilicity Fouling Only 65 0 2 4 6 8 10 12 14 16 18 Figure 5: Test summary of chronological variations for the cooling capacity of evaporator heat exchangers at the face velocity of 1 m/sec. Fig. 6 shows variations of cooling capacity for the evaporator heat exchangers used in the various application fields. The face velocity decreases with increasing operation time from year to year due to the air-side particulate deposition. This result is intended to provide the cooling capacity in the factual pressure drop data under actual operating conditions. In Fig. 6, the measurements of the cooling capacity are carried out at the same pressure drop across initially designed heat exchangers. All the samples are used for 6 years. The cooling capacities of the evaporator heat exchanger used in the seaside inn, the restaurant, the office and the residence are decreased by 14, 12, 7, and 4%, respectively. The evaporator heat exchanger used in the seaside inn shows maximum decrease of cooling capacity, because it has been exposed to somewhat high dust concentration and long operation time. The air conditioner used in the seaside inn is a window-type and the others are wall-mounted types. Generally, the windowtype is installed 1.5 m above the floor and the wall-mounted type is installed 2 ~ 2.5 m above the floor. There exists a significant difference of the suspended dusts concentration due to the human activity. The window-type is more affected by the suspended particles due to the installation height. Variations of cooling capacity (%) 95 85 75 70 6 years used Dry/Wet bulb : 27 É /19.5 É Seaside Inn Restaurant Office Residence Figure 6: Variations of cooling capacity for the evaporator heat exchangers used in various places at the same pressure drop of initial heat exchangers. Fig. 7 shows chronological variations for the cooling capacity of the evaporator heat exchangers in air-conditioners used in the seaside inn at the same pressure drop of the initial heat exchangers. In 7 years, the cooling capacity decrease down to 84% compared with the initial value. The cooling capacity decreases from year to year. It is believed that the deposition of indoor pollutants and the decrease of system flow rate due to increasing pressure drop degrade the cooling capacity of evaporator heat exchangers.

R020, Page 7 Variations of cooling capacity (%) 105 95 85 Dry/Wet bulb : 27 É /19.5 É 0 1 2 3 4 5 6 7 8 9 Figure 7: Chronological variations for cooling capacity of evaporator heat exchangers in air-conditioners used in the seaside inn at the same pressure drop of initial heat exchangers. Fig. 8 shows chronological variations for the cooling capacity of the air conditioner sets including the evaporator, the compressor, the condenser, and the air handling unit at the same pressure drop of the initial heat exchangers. Data of the solid symbols represent the cooling capacity due to the effect of particulate fouling in addition to that of hydrophilicity decrease, while the open symbols represent the effect of particulate fouling only. The cooling capacities due to the effect of particulate fouling in addition to that of hydrophilicity decrease (solid symbols) show larger degradations compared with those of particulate fouling (open symbols). It is believed that the higher pressure drop due to the decrease of hydrophilicity in the fin surfaces causes the air flow rate to be reduced and the cooling capacity to be decreased. The square symbols represent the window-type, while the circle symbols represent the wall-mounted type. The window-type air conditioners show large degradations in cooling capacity compared with the wall-mounted types because the window-types are more affected by the suspended dusts as explained in Fig. 6. The cooling capacity of the air conditioner sets which can be shown from data of solid and square symbols, compared with the results of evaporator heat exchangers as shown in Fig. 7, shows somewhat larger degradations because the performance deteriorations of the fan, the compressor, and evaporators including the inside and outside tube fouling occur simultaneously. Cooling capacity (%) 110 105 95 85 75 70 65 Window-Type, Fouling + Decrease of Hydrophilicity Wall-Mounted Type, Fouling + Decrease of Hydrophilicity 60 Window-Type, Fouling Only 55 Wall-Mounted Type, Fouling Only 50 0 2 4 6 8 10 12 Figure 8: Test summary of chronological variations for the cooling capacity of air-conditioner sets. 4. CONCLUSIONS The chronological performance such as pressure drop and cooling capacity due to the air-side particulate fouling of fin-and-tube heat exchangers for the used air conditioner evaporators is investigated using the psychrometric

R020, Page 8 calorimeter. 30 samples of air conditioners used in the field such as inns, restaurants, and offices are collected in chronological used order. This study is intended to provide factual long-term fouling data under actual operating conditions. Fouling of heat exchangers causes the decrease of cooling capacity and the increase of pressure drop as well as indoor air quality problems. The pressure drop of heat exchangers increases from year to year due to the deposition of indoor pollutants larger than 1 m in size and increase up to 44% in the samples used for 7 years. The pressure drop due to the decrease of hydrophilicity in the fin surface contributes more than 10 ~ 30% of the total pressure drop. Also the air-side particulate fouling degrades the cooling capacity by 10-15% in the samples used for 7 years. It is found that the important parameters to influence the fouling of heat exchangers are the concentration and size of indoor pollutants, the hydrophilicity of fin surfaces, and the structure of heat exchangers. For preventing the deterioration of evaporator heat exchangers, the longer lasting hydrophilicity as well as the prevention of fouling is very important. REFERENCES Ahn, Y. C., Han, J. G., Cho, J. M., Ock, J. H., Lee, H. W., Ahn, S. P., Youn, D. H., and Lee, J. K., 2002, An Experimental Study of the Air-side Fouling in Heat Exchangers of Air Conditioners, Proceedings of the 3rd Korean Conference on Aerosol and Particle Technology, p. 159-160. Bott, T. R., 1995, Fouling of Heat Exchangers, Elsevier, Amsterdam, Netherlands, 497 p. Epstein N., 1988, Fouling Science and Technology - Particulate Fouling of Heat Transfer Surfaces: Mechanisms and Models, Kluwer Academic Publishers, Dordrecht, Netherlands, 143 p. Incropera, F. P., and DeWitt, D. P., 1996, Fundamentals of Heat and Mass Transfer 4th ed., John Wiley & Sons, New York, U.S.A., 568 p. Korean Standard, 2002, Air Conditioners, KS C 9306. Marner, W. J., MacDavid, K. S., and Muzio, L. J., 1989, Development of a Gas Side Fouling Measuring Device, National Heat Transfer Conference, no. 108, p. 305. Siegel, J. A., 2002, Particulate Fouling of HVAC Heat Exchangers, Ph. D. Thesis, University of California, Berkeley, U.S.A. Thatcher, T. R., and D. W. Layton, 1995, Deposition, Resuspension, and Penetration of Particles within a Residence, Atmospheric Environment, vol. 29, no. 13: p. 1487. ACKNOWLEDGEMENT The authors wish to thank the LG Electronics Inc. for its financial support to this research.