Innovative. Efficient. Dependable. Dunkirk. Dunkirk H 2 O - Stainless Steel Single Indirect Water Heaters - Stainless Steel Storage Tanks - Stainless Steel Hydronic Buffer Tanks - Stainless Steel Single and Dual Solar Water Heaters
THE DUNKIRK H 2 O SERIES A complete line of Stainless Steel, Single and Dual Indirect Water Heaters, Storage Tanks, and Hydronic Buffer Tanks. Need An Easy Domestic Hot Water Solution With A Low Operating Cost and the Longevity Of Stainless Steel? Dunkirk H 2 O Stainless Steel Single Indirect Water Heaters Need A Hot Water Solution To Balance Input and Storage While Reducing Short Cycling? Dunkirk H 2 O Stainless Steel Storage Tanks Need A Hot Water Solution For Use With Chillers, Heat Pumps, and Low Mass Boilers? Dunkirk H 2 O Stainless Steel Hydronic Buffer Tanks Need A Hot Water Solution For Solar Applications Or Small Zones? Dunkirk H 2 O Stainless Steel Single & Dual Solar Water Heaters (Optional Electric Back-Up can heat the tank if solar heat is unavailable) STANDARD FEATURES Stainless Steel Single Indirect Water Stainless HeatersSteel Single Indir Water Heate Capacities (Gallons) 30, 40, 40L, 50, 60, 60L, 80, 85* & 115 316L Stainless Steel Construction Top Connections (For Easy, Neat, Clean Installation) Welded Stainless Steel Dip Tube (Factory installed) Thermoplastic Jacket (Won t dent, scratch or corrode) Low Drop (Ideal For Low Mass Boilers) Magnesium Anode Rod T & P Valve (Factory installed except on 85 & 115XHOC) Aquastat and Drain Valve Provided 2.25 EPS Insulation (Provides Less Than.5 F Per Hour Standby Loss) Large Diameter, Smooth Heat Exchangers - Prevent Buildup (Stainless Steel s Are 25 to 30 Long and 1-1/8 in Diameter) Honeywell L4080B (Shipped Loose) Made in the USA WARRANTY Limited Lifetime Warranty (Residential), 5 Yr. (Commercial) 15 Year Warranty (Residential) OPTIONS Low Profile High Output Extra High Output Electric Back-Up Commercial Connections (For increased DHW flow) *Only offered in Extra High Output models. 40L & 60L Capacities 80 & 115 Capacities 85 & 115 Capacities 60, 80 & 115 Capacities 80 & 115 Capacities ( Dom., Blr.)
rs ect Stainless Steel Storage Tank Stainless Steel Buffer Stainless Tanks Steel Buffer Tanks Stainless Steel Dual Solar Water Stainless HeatersSteel Dual Solar Water Heaters 30, 40, 60, 60L, 80 & 115 22, 40, 60, 80 & 115 60, 80 & 115 * 60L Capacities 60, 80 & 115 Capacities 80 & 115 Capacities ( ) 40, 60, 80 & 115 Capacities (,, 2 ) 22 Capacity ( only) 22, 40, 60, 80 & 115 Capacities
Dunkirk H 2 O Stainless Steel Single Indirect Water Heaters Illustrations STANDARD AND HO UNITS HOC UNITS XHOC EXTRA HIGH OUTPUT UNITS Storage Volume Heating Surface Dimensions Gallons Square Feet Height Diameter Piping Connections N.P.T. Domestic Water In/ Out Boiler Water In/ Out Max. Tank Working Max. Working Approx. Shipping Wgt. (psi) (psi) (lbs.) H2OI30DK 30 7.3 34.0 23.5 3/4 1 150 90 85 H2OI40DK 40 7.7 44.0 23.5 3/4 1 150 90 100 H2OI40LDK 42 7.4 36.0 28.0 3/4 1 150 90 100 H2OI50DK 50 8.2 54.0 23.5 3/4 1 150 90 110 H2OI60DK 60 8.6 62.0 23.5 3/4 1 150 90 125 H2OI60LDK 60 7.7 46.0 28.0 3/4 1 150 90 120 H2OI80DK 80 8.2 56.0 28.0 1 1 150 90 140 H2OI115DK 115 9.1 74.0 28.0 1 1 150 90 175 High Output Units H2OI60HODK 60 15.1 62.0 23.5 1 1 150 90 145 H2OI80HODK 80 14.8 56.0 28.0 1 1 150 90 155 H2OI80HOCDK 80 14.8 56.0 28.0 150 90 155 H2OI115HODK 115 15.6 74.0 28.0 1 1 150 90 190 H2OI115HOCDK 115 15.6 74.0 28.0 150 90 190 Extra High Output Units 85-XHO and 115-XHO H2OI85XHOCDK 87 28.7 64.0 28.0 150 90 215 H2OI115XHOCDK 115 28.7 74.0 28.0 150 90 240 General Information (See Installation, Operation and Maintenance Manual for complete instructions) Max. First Hour Rating Continuous Rating Boiler Output Needed Boiler Water Flow Through Drop Through Gal./Hr. @ Gal./Hr. @ 140 F 115 F 140 F 115 F (BTU/Hr) (Gal./Min.) (Ft. Water) H2OI30DK 202 269 175 242 131,250 14.0 5.3 H2OI40DK 221 292 185 256 138,670 14.0 5.7 H2OI40LDK 212 251 176 215 132,000 14.0 5.3 H2OI50DK 223 291 178 246 133,280 14.0 6.0 H2OI60DK 262 342 208 288 155,700 14.0 6.2 H2OI60LDK 239 310 185 256 138,570 14.0 5.7 H2OI80DK 271 248 199 276 149,390 14.0 6.0 H2OI115DK 324 409 221 306 165,750 14.0 6.6 High Output Units 60-HO, 80-HO, and 115-HO H2OI60HODK 406 541 352 478 263,600 14.0 10.1 H2OI80HODK 418 551 346 479 259,640 14.0 9.9 H2OI80HOCDK 442 584 370 512 277,070 21.0 10.5 H2OI15HODK 467 607 364 504 273,100 14.0 15.8 H2OI115HOCDK 479 623 376 520 281,800 21.0 16.7 Extra High Output Units 85-XHO and 115-XHO H2OI85XHOCDK 738 992 660 914 495,000 28.0 13.0 H2OI115XHOCDK 763 1017 660 914 495,000 28.0 13.0 Note: All ratings are based on 200 F boiler water supply and 50 F cold water inlet. See installation manual for ratings at different temperatures and flow rates. Specifications subject to change without notice. Equipment Options Certification/ Decoding Smooth stainless steel coil, magnesium anode rod, factory installed stainless steel aquastat well, T & P and drain valve, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat shipped loose for field installation. (L) Low profile models for applications with low clearances. (C) Commercial models with larger tappings for higher flow rates. (HO) High Output models available to meet greater demand. (XHO) Extra High Output models. H2O I=Indirect Capacity: 30=30 Gals. 40=40 Gals. 50=50 Gals. L=Lowboy C=Commercial HO=High Output HOC=High Output 60=60 Gals. Commercial 80=80 Gals. XHO = Extra High 85=87 Gals. Output 115=115 Gals. L DK DK=Dunkirk Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94
Dunkirk H 2 O Stainless Steel Storage Tanks Piping Connections NPT Dimensions/Weights Storage Capacity (Gals.) Cold/Hot Supply/Return Heat Source SUPPLY TO HEAT SOURCE 8.0 T+P VALVE RETURN FROM HEAT SOURCE H2OST30DK 30 1 1 H2OST40DK 40 1 1 H2OST60DK 60 1 1 8.0 H2OST60LDK 60 1 1 H2OST80DK 80 1 1 COLD WATER INLET HOT OUTLET H2OST115DK 115 1 1 TOP CONNECTIONS ALL 1" NPT H2OST80CDK 80 1 H2OST115CDK 115 1 Note: Max. Working pressure 150 psi for all capacities. 3/4" NPT RECIRC. PORT 1 1/2" NPT HOT OUTLET AQUASTAT WELL DRAIN STANDARD UNITS 8.0 T+P VALVE General Information (See Installation, Operation and Maintenance Manual for complete instructions) Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (L) Low profile models for applications with low clearances. (C) Commercial models available for applications with larger connections. H2O ST=Storage ST Tank Capacity: L=Lowboy 30=30 Gals. C=Commercial 40=40 Gals. 60=60 Gals. 80=80 Gals. 115=115 Gals. L DK DK=Dunkirk 8.0 1" NPT SUPPLY TO HEAT SOURCE 1" NPT RETURN FROM HEAT SOURCE Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94 1 1/2" NPT COLD INLET AQUASTAT WELL Schematic Diagram (Typical Installation) 9.5 DRAIN COMMERCIAL UNITS s Dimensions & Weights Height Dia. Shp. Wgt. (Lbs.) H2OST30DK 34.0 23.5 75 H2OST40DK 44.0 23.5 90 H2OST60DK 62.0 23.5 115 H2OST60LDK 46.0 23.5 110 H2OST80DK 56.0 28.0 140 H2OST115DK 74.0 28.0 175 H2OST80CDK 56.0 28.0 140 H2OST115CDK 74.0 28.0 175
Dunkirk H 2 O Stainless Steel Buffer Tanks Dimensions/Weights Storage Capacity (Gals.) Piping Connections NPT H2OBT22114DK 22 H2OBT40114DK H2OBT40112DK 40 H2OBT402DK 2 H2OBT60114DK H2OBT60112DK 60 H2OBT602DK 2 H2OBT80112DK H2OBT80114DK 80 H2OBT802DK 2 H2OBT115114DK H2OBT115112DK 115 H2OBT1152DK 2 H2OBT40114WCDK H2OBT40112WCDK 40 H2OBT402WCDK 2 H2OBT60114WCDK H2OBT60112WCDK 60 H2OBT602WCDK 2 H2OBT80114WCDK H2OBT80112WCDK 80 H2OBT802WCDK 2 H2OBT115114WCDK H2OBT115112WCDK 115 H2OBT1152WCDK 2 Note: Max. Working pressure 60 psi for all capacities. Dimensions & Weights Height A B C H2O22BT114DK 24.5 15.0 8.0 H2O40BT114DK H2O40BT112DK H2O40BT2DK H2O60BT114DK H2O60BT112DK H2O60BT2DK H2O80BT114DK H2O80BT112DK H2O80BT2DK H2O115BT114DK H2O115BT112DK H2O115BT2DK 42.0 29.0 9.0 42.0 29.5 9.5 52.0 39.5 9.5 72.0 59.5 9.5 Shp. Wgt. (Lbs.) 35 (45 WC) 87 (97 WC) 115 (125 WC) 125 (135 WC) 160 (170 WC) General Information (See Installation, Operation and Maintenance Manual for complete instructions) Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (WC) With H2O BT=Buffer BT 40 Tank Capacity: 22=22 Gals. 40=40 Gals. 60=60 Gals. 80=80 Gals. 115=115 Gals. 114 114= NPT WC=With 112= NPT 2=2 NPT WC DK DK=Dunkirk Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94
DUNKIRK H 2 O STAINLESS STEEL BUFFER TANKS Reduces chiller or boiler short cycling (Short cycling results in reduced operating efficiency and shorter equipment life) Used in systems having several low BTU cooling or heating loads calling at different times Full size tappings on buffer tank for peak performance (,, and 2 ) Used in systems operating below the design load condition, which is most of the time. H 2 O HYDRAULICALLY DECOUPLED To/From Boiler/Chiller/Heat-Pump To/From System Buffer Tanks Buffer Tank Sizing - Calculating Capacity Dunkirk H 2 O buffer tanks are a simple, cost effective way to improve overall system efficiency by reducing unnecessary equipment short cycling. The recommended capacity or volume of a buffer tank is based on four variables. 1) The duration of the heating or cooling source on time (minutes). The desired length of on time for each run cycle depends on the type of equipment used. Heat pump and chiller manufacturers typically recommend a minimum of 5 to 10 minutes on time, and boiler manufacturers may recommend a minimum of 10 minutes on time. Check with your equipment manufacturer. Generally, the longer the on time, the higher the overall operating efficiency. 2) The minimum rate of heat input (BTU/HR). This is based on the heat pump or chiller output, or the boiler output at the minimum firing rate if the boiler has a variable input system that ramps input down as the demand decreases. 3) The minimum system load (BTU/HR). This is the demand placed on the system with the smallest zone calling for heat. 4) The allowable tank temperature rise (deg. F). This varies depending on the type of heating or cooling system used, and on the design of the distribution system. Chillers may require a tight, (6 deg. F), differential to assure good dehumidification and prevent freezing, heat pumps may require a (10 deg. F) differential to maintain a high COP, and boilers with hydronic heating distribution systems may require a differential anywhere between 10 to 40 deg. F depending on the application. The following formula determines the tank volume: V = T X ( Q heat input - Q min. heat load) Tank temp. rise X 500 V = Buffer tank volume (gallons) Q heat source = heat source output (BTU/HR) Tank temp rise (deg. F) T = desired heat source on cycle (min.) Q min. heat load = heat output to minimum load Water to Water Heat Pump Example: Town and Country Mechanical wants a minimum heat pump on time of 10 minutes. The heat pump output is 46,500 BTU/HR. The smallest zone is a 7,000 BTU/HR bathroom. The allowable temperature differential is 90 to 100 deg. F for the radiant heat zones. 10 x (46,500 V = - 7,000) = 79.0 Gallons minimum volume. Choose the H2O80BT buffer tank. (100-90) x 500
Dunkirk H 2 O Stainless Steel Dual and Single Solar Water Heaters Dimensions/Weights TOP COIL SUPPLY COLD WATER IN BOTTOM SOLAR COIL RETURN Dimensions & Weights s T+P VALVE Height SINGLE COIL Dia. Shp. Wgt. (Lbs.) H2OI60EDK 62.0 23.5 135 H2OI80EDK 56.0 28.0 145 H2OI115EDK 74.0 28.0 180 DUAL COIL TOP COIL RETURN HOT WATER OUT BOTTOM SOLAR COIL SUPPLY TOP COIL 3/8" ID THERMAL WELL 1/2" NPT RECIRC. RETURN PORT TOP HEATING COIL FOR BACKUP BOTTOM COIL 3/8" ID THERMAL WELL BOTTOM HEATING COIL FOR SOLAR DUAL COIL UNITS H2OI60DDK 62.0 23.5 165 H2OI80DDK 56.0 28.0 175 H2OI115DDK 74.0 28.0 205 H2OI60DEDK 62.0 23.5 175 H2OI80DEDK 56.0 28.0 185 H2OI115DEDK 74.0 28.0 215 1.5 4" X 10" ELECTRICAL BOX 3/8" ID THERMAL WELL DRAIN VALVE ELECTRIC BACKUP UNITS Storage Capacity (Gals.) Top Heating Surface Sq. Ft. SINGLE COIL Bottom Heating Surface Sq. Ft. Piping Connections NPT H2OI60EDK 60 8.3 1 H2OI80EDK 80 8.0 1 H2OI115EDK 115 8.9 1 DUAL COIL H2OI60DDK 60 7.4 8.3 1 H2OI80DDK 80 7.4 8.0 1 H2OI115DDK 115 7.4 8.9 1 H2OI60DEDK 60 7.4 8.3 1 H2OI80DEDK 80 7.4 8.0 1 H2OI115DEDK 115 7.4 8.9 1 Note: Max. Working pressure 150 psi for all capacities. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Max. First Hour Rating Gal./Hr. @ Continuous Rating Gal./Hr. @ Max. Rec. Top Max. Rec. Bottom Min. Boiler Water Flow Through Drop Through 140 F 115 F 140 F 115 F (Gal./Hr.) (Gal./Hr.) (Gal./Min.) (Ft. Water) SINGLE COIL H2OI60EDK 45.9 52.0 15.9 22.0 214 10.0 3.5 H2OI80EDK 55.9 62.0 15.9 22.0 214 10.0 3.6 H2OI115EDK 73.9 80.0 15.9 22.0 214 10.0 3.9 DUAL COIL H2OI60DDK 45.9 52.0 15.9 22.0 185 214 10.0 3.5 H2OI80DDK 55.9 62.0 15.9 22.0 180 214 10.0 3.6 H2OI115DDK 73.9 80.0 15.9 22.0 190 214 10.0 3.9 H2OI60DEDK 45.9 52.0 15.9 22.0 185 214 10.0 3.5 H2OI80DEDK 55.9 62.0 15.9 22.0 180 214 10.0 3.6 H2OI115DEDK 73.9 80.0 15.9 22.0 190 214 10.0 3.9 Note: All ratings are based on 180 F boiler water supply and 50 F cold water inlet. For Dual units, continuous ratings shown are for the lower coil only. Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory factory installed installed and pressure and pressure tested, Honeywell tested, Honeywell L4080B L4080B aquastat aquastat for field for installation field installation. (single coil only). Removable thermal well to accept a solar control thermostat or thermistor. Dual coil units equipped with two aquastat wells which control each coil independently and built-in recirculation tapping. tapping. Units Units with with Electric Electric Back-Up Back-Up are provided are provided with with 4 x 4 10 x electrical 10 electrical box box with with pre-wired pre-wired heating element, thermostat, and hi-limit. All electric back-up units provided with 240 volt AC, 3500 watt recirculation element. (E) Electric Back-Up models for supplemental heating. H2O 60 D I=Indirect Capacity: D=Dual E=Electrical DK=Dunkirk 60=60 Gals. Back up 80=80 Gals. (3500 Watts) 115=115 Gals. Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94 E DK PN 240009330 Rev. 8/16 Contractor Assistance: 800.325.5479 P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 fax: 315.797.3762 www.dunkirk.com