AC2000 Security Hub Security and Event Management System

Similar documents
Patriot Systems Limited

Patriot Systems Limited

Architectural and Engineering Specification for a Security Management System. StarNet 2

Recording Server PRELOADED

D-Link Central Management System

PotterNet Fire & Facility Supervising Station

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Building Integration System. Your platform for customized security and safety management.

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Complexity made simple

Access CONTROL. MANAGEMENT Software

BIS - Overview and basic package

System Description AutroMaster V Presentation System

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

GMS GRAPHICAL MANAGEMENT SYSTEM

MobiCall-Client PC Safety at work

Datasheet. Version 3.8. License Plate Recognition + Red Light Violation Detection. Datasheet LPR + RLVD Version

Avigilon Control Center System Integration Guide

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Ademco Vista Alarm Panel

X.90 Access Control System

Cardax System Comparison

USER S GUIDE. AXIS Cross Line Detection

Ion Gateway Cellular Gateway and Wireless Sensors

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Avigilon Control Center System Integration Guide

Before you install ProSeries Express Edition software for network use

Tyco Security Products Acquires Innometriks Deal strengthens TSP s Solutions in the Government Market

Datasheet Crowd Management

Access Professional Edition. The flexible access control system that grows with your business.

Introduction. Introduction

Milestone XProtect Alarm Matrix Integration 1.0

HWIN CCTV Camera Control Application

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Genesys the power to integrate A pioneer in integrated security management solutions

Success Story Claas. Ein WinGuard Reference Project

HikCentral Web Client. User Manual

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Aviation Solutions. Why Tyco for airports? Our systems help protect over 110 airports. Secures over 80% of UK Airports and more than 60 US Airports

Avigilon Control Center System Integration Guide

Table of Contents. i-vu CCN Standard 4.2

Network Hardware and wiring (quiz)...

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

HikCentral Web Client. User Manual

i-vu CCN 4.0 Owner s Guide

CompleteView SightLogix Sensor Setup Manual. CompleteView Version 4.7.1

This technical update applies to Pro-Watch Software Release 3.5 and later.

Compact Product Suite Compact HMI 6.0 Overview ABB

TruVision Navigator. Centralised video, access control and network management

Avigilon Control Center 5 System Integration Guide

Facility Commander Wnx

Pro-Watch Facility Manager

ONYXWORKS AND FIRSTVISION. Version 4

Supervisor Standard Edition

DATAssure. Laboratory wireless alarm & monitoring system

Oracle Communications Performance Intelligence Center

Perimeter Product Overview. Effective protection for your business

Avigilon Control Center 5 System Integration Guide

Datasheet Face Recognition [Genetec VMS]

Milestone XProtect. Central 3.7 User s Manual

Product Brief for Alarm Analytics V9.2 April 2010

Laptop / PC Programming Manual

Secure Your Way of Life. Now Compa ble With. Climax Home Portal Platform. Enable a Connected Future

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

Installing ProSeries 2005

Monitoring Operator Guide. Access Control Manager Software Version

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Milestone XProtect Alarm Matrix Integration 1.0

Before you install ProSeries software for network use

Product Brief for Alarm Analytics V9.3 October 2013

Gallagher System Integrations

GE Security. Wnx. Facility Commander. Integrated security management platform for Windows. Seamless. Effective. Efficient.

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

Net2. Total Access Control.

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

Course Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers

First day: SmartLink Web and SmartPager SmartLink and SmartPager installation Second day: SmartLink and SmartPager Configuration Alarms Management

MegaPower CPU ADMPCPU

Pocket CO2 Monitor & Data Logger SAN-0001

ACCESS CONTROL SOLUTIONS ACTEC SERIES

Before you install ProSeries software for network use

Integrated security management platform for Windows. Seamless. Effective. Efficient.

MultiSite Manager. Setup Guide

Getting Started with Live Exceptions

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

OnGuard 7.2 Resolved Issues

Avigilon Control Center 5 System Integration Guide

P2000 and Metasys System Integration

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

P2000 and Metasys System Integration

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe)

TW-8000 TAUT WIRE FENCE

Datasheet Video Based Fire & Smoke Detection

ID2000. intelligent fire alarm panel

Transcription:

AC2000 Security Hub Security and Event Management System Features that make a difference: Centralised central alarm management application for Access Control, Video, Fire, Intruder and Building Management (Using External Application Feature) Advanced alarm processing capabilities Unlimited customisable alarm workflows for every alarm type Sophisticated alarm escalation feature with customisable time zones Real-time graphical map display that can be tailored to meet every operators requirements Oneshot and broadcast for remote opening and management of access control doors Dedicated video micro viewers for real-time and archived alarm monitoring Customisable device icon and alarm annunciation Advanced user restrictions for multi-user applications, restriction access to site maps, floor maps, devices and alarms. Dedicated alarm pop up window Inbuilt system reports for quick access to alarm, alarm escalation and user history Fully integrated guard tour events application Fully integrated cardholder trace feature Detailed in-app reports Configurable Map Zones Threat Levels indicator AC2000 Security Hub is the central alarm management platform for the AC2000 access control system. Leveraging client server architecture, the Security Hub application provides a powerful and versatile feature set, enabling system operators to configure, monitor and control their security system. The multi-user interface provides local or multi-site monitoring of access control, video, fire, intruder and building systems. Security Hub assists in reducing risk and cost while maximising efficiency, situation awareness and accountability. Central Alarm Monitoring and Management AC2000 Security Hub allows the monitoring and control of your site using one single unified platform which helps to keep operating costs low and ensures that alarms and events can be managed quickly and effectively. Alarms and Devices AC2000 Security Hub has an alarm application which displays information about the type of alarm, alarm description, device address, priority level, alarm time, state, associated video and alarm owner (for multi-user systems where more than one operator can be managing alarms). Operators can right click on any alarm and zoom directly into the device location on a graphical map, run a device report, or with the correct authorisation level isolate the device. Device isolation allows operators to inhibit any further alarms occurring on a particular device, which is ideal for device maintenance. Operators can select any alarm and initiate the alarm processing application which will provide them with a set of instructions they must follow to acknowledge an alarm and then reset if applicable. The AC2000 Security Hub also provides operators with a devices application which will display information about all devices connected to Security Hub such as Device Type, Device Description, Total Number of Alarms, First and Last alarm times and information on whether an alarm has been filtered or isolated giving operators a complete view of the status of all alarms and devices in real time. Alarm workflows Security Hub allows system operators, who have the correct authorisation level, to create a number of alarm workflows which consist of a set of instructions or actions that must be taken by the system operator before an alarm can be reset. Security Hub workflows, once created can be saved against an individual alarm or saved as a workflow template that can be assigned to any other alarm for ease of configuration. Once alarm workflows have been created and assigned they will then be available in the alarm processing application. www.cemsys.com

Alarm Escalation AC2000 Security Hub alarm escalation is a method in which an alarm can increase in priority overtime when not acknowledged by a system operator. Alarm escalation is an important component for any security management system. Security Hub alarm escalation is highly configurable and alarms of low priority can be automatically escalated to a higher priority level if not acknowledged within a defined time period. The levels at which an alarm can increase have a user defined incremental value. The alarm escalation rules can be applied based on specific alarm types as well as time zones. The alarm escalation window is system check pointed so only operators with the correct authorisation level will be able to view escalated alarms i.e. system supervisors. For multi-user sites information will be available to each system operator which will detail the current alarm Owners (person who is actively processing the alarm) and also what operator is currently viewing the alarm. These operators can use the inbuilt alarm and device notes feature to send notes to each other in real time or save notes for system operator to view at a later date. Alarm pop-up The Security Hub application has an additional feature where a small interactive alarm pop-up window will display in the bottom right hand of the screen. This is ideal for situations were an operator is viewing another application outside of the security hub application and ensure there are multiple levels of notification with the security system. Alarm Actions AC2000 Security Hub alarm actions allows a system operator with the correct authorisation level to setup and link any system alarm from any device type and initiate a 3rd party application and pass parameters to this application if applicable. This feature is particularly important during emergency situations such as fire evacuations. Any 3rd party fire system that can be connected to a CEM systems device can then be used to trigger emergency muster report printouts in an available emergency situation. Video Micro-Viewer The Security Hub video micro viewer feature allows the system operator to view live and recorded footage, simultaneously as they process alarms within the Security Hub alarm processing application. The video micro viewers can be launched via the video tab from within Security Hub or from the associated alarm processing application. If more than one camera has been assigned to an alarm or device; an option is available to select each camera view for both recorded and live viewing as required. The video micro viewers are only accessible with systems that have a fully interfaced video integration (Please contact CEM Systems for further information). Alarm Processing The Alarm Processing application is a user friendly window for system operators to view detailed information about system alarms and process these alarms in order for them to be acknowledged and reset. System operators can view multiple alarms in different tabs within the alarm processing application and will be presented with information about the alarm type, date/time stamp of occurrence, priority level and location (a map tab is available to show a snapshot of the device location on the graphical maps if applicable). Information about the devices history will display all active alarms for that device providing real-time status of the security systems alarm states. If Alarm workflows have been defined, these will also be presented to system operators all within the one active display screen.

Alarm Priority banner AC2000 Security Hub has a dedicated alarm priority banner that will always display the highest priority alarm across the top of the Security Hub system to ensure the most critical system alarms are processed as quickly as possible. Each user has the ability to configure the alarm priority banner to display either the latest alarms first or the oldest alarms first based on their preferences. It is also possible to further configure the alarm banner so only the highest user defined priority alarms are displayed within the priority banner. One-shot and Broadcasts AC2000 Security Hub provides system operators with the ability to control all system devices connected to the AC2000 system. Operators can open access controlled doors directly via device icons that can be placed on the graphical maps or launched from the Security Hub tab menu. There is also the ability to send broadcast commands which can open all or a group of doors from directly within the one unified security platform. This is ideal for situations where cardholders have forgotten their passes or in emergency situations where free access is critically required. Graphical Maps Once configured, the AC2000 Security Hub Maps application displays a user friendly graphical overview of the alarms and devices contained within your security management system, detailing specific information about a device, input or alarms location. Maps are added to Security Hub in a tree based system, comprising of overview, sites and floor maps. Each map can be nested on top of each other in an unlimited tree based structure. Note maps can be uploaded in the following formats:.jpeg.png.bmp.gif.tif Device icons and inputs can then be dragged and dropped onto their relevant location within the uploaded maps. Icons can then be configured to a specific size as required. Further to this it is also possible to define the alarm annunciation area (area that will display a flashing indication of an alarm) of each device or input icon creating a highly customisable security management system application. Layout Management AC2000 Security Hub provides operators with the ability to open a set of applications and create floating windows that can then be grouped together into a customised screen layout across single or multi-monitored system. The customised layouts are saved against the user and not the workstation meaning that the same layout will be presented to the operator every time they login to a client workstation. Layouts can be configured to display Maps, Alarms, Video and alarm processing in a layout that can help improve the ergonomics of the system operators. External Applications and Command Buttons AC2000 Security Hub external applications features allows any 3rd party application to be added to the Security Hub window bar; providing a seamless low level interface to any 3rd party system. By providing the ability to launch 3rd party applications from directly within Security Hub it ensures system operators have quick access to key systems packages that are required for day to day operation of the security system. For example HVAC, Intelligent lighting, Video and CRM systems to name a few. Additionally command button icons can be created and placed directly on any graphical map. This enables them to launch application and pass parameters to control 3rd party systems such as lighting, HVAC and access control doors and video systems, making it easier for system operators to control and manage the entire security system from directly within AC2000 Security Hub. Guard Tour Events AC2000 Security Hub has an inbuilt guard tour events application which displays all event and notifications of an upcoming and in progress guard tour. The information displayed to a system operator includes the guard tour name, event type, date/ time, name of guard, device address and description along with the active guard tour input. Guard tours can be setup and managed from within the AC2000 guard tour application and monitored directly within Security Hub providing a single unified view of the security management system. Trace Events AC2000 Security Hub has an inbuilt cardholder trace feature which allows a system operator to follow and track any cardholder who has been perceived to be either a threat or a possible liability to the security or the safety of the facility and people within it. Threat Levels AC2000 Security Hub allows the security operator to view and set threat levels directly from within the application and the current status is displayed in the main status bar.

In App Reports AC2000 Security Hub features wide range of in-app reports which provide information about alarms, alarm escalation, alarm priorities, users, device transactions**, traces** or version numbers**. Each report can be setup and run based on time and dates, devices, alarm priorities and even users. Each report can be printed directly from within the security application or exported in either XPS or PDF formats.or a possible liability to the security or the safety of the facility and people within it. Map Zones** AC2000 Security Hub Maps allows drawing a zone in the section of the map by adding points in desired area, which in turn creates lines. Each zone can be easily adjusted by moving zone points and changing the shape of the zone. Devices can now be placed onto the maps and into the individual zones. User Restrictions The AC20000 Security Hub application has been designed for multi-user purposes and can be highly customised and restricted based on a user s specific requirements. To allow for this the Security Hub user restrictions features allows administrators to create and assign user restriction templates that restrict access to individual site maps, floors plans, devices, inputs and also restrict access to all of the Security Hub default and user defined alarm types. Customisation Settings The AC20000 Security Hub application is a highly flexible and customisable application. Security Hub provides operators with the ability to use default system icons or use their own custom icons. The Security Hub customisation settings also allow operators to define an icons size, angle, annunciation area as well as a custom colour for each alarm type using an integrated colour palette. These settings can then be saved against a device template which can be used for other device configurations to reduce set up time. There is also a further option to configure custom sounds for each specific alarm type as required. These templates can then be assigned to specific users that have been created within the AC2000 software platform. This is an ideal SMS feature were system operators are managing the security across multiple buildings, regional and global locations and ensures access to important alarm information can be controlled at a centralised level.

Minimum Requirements Security Hub Workstation Model Dell OptiPlex 7010 DT Desktop Computer Processor Type 3 rd Gen Intel Core i5-3470 Processor Processor Speed Quad Core, 3.20GHz Turbo Internal cache Standard Memory 4GB (2X2GB) 1600 MHz DDR3 Non-ECC Internal Hard Drive 250GB 3.5 SATA Hard Drive Controller NO RAID Optical Drive Type Optical Drive : 16XDVD+/-RW Drive Other Drives None Monitor 17 LCD for Workstation & VIPPS, 19 LCD for AED. Chassis Type Desktop PSU Single Dimensions 36.0 x 17.5 x 41.7 Requirements AC2000 v7.1 software & upwards AC2000 Airport v7.1 software & upwards AC2000 Lite v7.1 software & upwards For Graphical Maps AC2000 Security Hub Maps License For Video Micro viewer A supported video interface license * AC2000 Security Hub is a new application within the AC2000 software suite. For existing customers who would like to upgrade and use AC2000 Security Hub it will require that all existing AED configurations be re-configured manually within the new Security Hub application. ** Features available from AC2000 v8.0 onwards Ordering Information Product Code Description SWA2SECHUB AC2000 Security Hub Graphical Maps Utility (Global) Related Products AC2000 AC2000 Airport AC2000 Lite www.cemsys.com 2017 Tyco Security Products. All Rights Reserved. CEM/B/372 Rev C Tyco and the product names listed above are marks and/or registered marks. Unauthorized use is strictly prohibited. Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative.