MEDI-LINK USER MANUAL

Similar documents
CORPORATION PTY LTD MEDI-LINK

MEDI-MINDER USER MANUAL

MEDI-MINDER USER MANUAL

Medi-Minder Guardian USER MANUAL

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Wireless Call Point ( )

NON-MONITORED EMERGENCY CALL SYSTEMS

SMARTWALK DEMENTIA WANDERING SYSTEM

Wander-Alarm DOORWAY SENSORS

Installation and user guide

Tunstall Vi+ User Guide

TYNETEC. Telecare for independent living THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MOBILE NETWORK

MK9 series CarePhone. Installers Mauual

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Smart Hub. User & Installation Guide

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

A Complete Smart Care Solution

MEDICAL ALERT SETUP GUIDE

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

Your Lifeline Vi+ home unit. Your MyAmie pendant

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

ERS-3600B. PERS-3600B Personal Emergency Reporting System

BURGLAR ALARM PANEL BS-468

NetworX NX-8V2. LED Keypad User Manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

Version 1.03 January-2002 USER S MANUAL

Automation. Smartphone Operation. Ness D8x / D16x alarm control panel. User's MANUAL. Revision 7.8.2

1. Introduction. 2. Product overview

USER GUIDE HARDWIRED CONTROL PANELS

NETWORX TM. User manual NX-4

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

User Guide. Contents. About this guide. i-on Style Security System

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

System. For a better understanding of this product, please read this user manual thoroughly before using it.

JA-63 Profi User manual

How to Build Visonic PowerMaster Wireless Alarm Systems

169MHz Telecare Devices Universal Transmitter

Wireless Keypads LKP(E)S8M Series

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

SECURITY SYSTEM NOTES

SA 2650 Kit User Manual

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

Watchguard Digital V2 Back-To-Base Monitored Alarm System with Wireless Detectors, Remote Controls & Wireless External Siren

A Complete Smart Care Solution

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Telecare User Guidance

Frequently Asked Questions

SAT-3 Room Temperature Controller

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

ezone Alert System ezone is a UK designed and manufactured care alerting system unlike any other comparably priced system.

HILLS Series LED Code Pad User Manual

Lifeline Vi Clever, not complicated

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Valet Digital Back-To-Base Monitored Alarm System with Wireless Detectors, Remote Controls & External Siren

USER & INSTALLATION GUIDE

Contents. Glossary

communicall connect solutions sheet What is Communicall Connect? Who is it for? What does it consist of?

PiSector GSM Cellular Wireless Alarm System

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

HOME MANAGEMENT GATEWAY

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L

Wireless Keypad GKP-S8M

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

Destiny Destiny Owners Manual

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Security System. User Guide for the LED Command Center

SMS8 Alarm Control Panel

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

HG Home Guardian Advanced Home Energy, Safety and Security Management

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

The complete wirefree security alarm solution

DET-RWATER Flood Detector Installation Guide

Solution Ultima 862 Operators Manual ISSUE 1.10

MOBILE CALL GSM Alarm System User s Manual

USER'S OPERATING INSTRUCTIONS

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

1126 Series Ceiling Mount PIR Motion Detector

Ness D8x / D16x ALARM CONTROL PANEL USER'S MANUAL. Revision 5.0 A$15.00

TABLE OF CONTENTS. Your Northwood Intouch Unit (Diagram)...1. How to use your Emergency Response System... 2

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

NetworX Series NX-1500E LED Keypad

WiFi GSM APP Smart Home Security System

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Transcription:

MEDI-LINK USER MNUL Medi-Link User Manual Rev1.2

division of NESS CORPORTION PTY LTD November 2015 Unit 4/56 Norcal Rd, Nunawading VIC 3131 ustralia Tel: +61 3 9875 6400 Facsimile: +61 3 9875 6422 Email: smartlink@ness.com.au Web Site: www.smartlink.com.au SmartLink Medi-Link User Manual Rev 1.2 Document Part Number: 890-382 For Products: Medi-Link Unit Ness Corporation Pty Ltd BN 28 069 984 372 Specifications may change without notice. Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and diligence has been applied during manufacture to ensure the reliable operation of this product. However there are various external factors that may impede or restrict the operation of this product in accordance with the product s specification. These factors include, but are not limited to: 1. Erratic or reduced radio range. Ness radio products are sophisticated low power devices, however the presence of in-band radio signals, high power transmissions or interference caused by electrical appliances such as wireless routers, cordless phones, computers, TVs and other electronic devices may reduce the range performance. While such occurrences are unusual, they are possible. In this case it may be necessary to either increase the physical separation between the Ness receiver and other devices or if possible change the radio frequency or channel of the other devices. 2. Unauthorised tampering, physical damage, electrical interruptions such as mains failure, electrical spikes or lightning. 1

TBLE OF CONTENTS INTRODUCTION...2 MEDI-LINK FETURES... 3 USING YOUR MEDI-LINK... 5 SETTING THE TIME & DTE... 5 TO CLL FOR HELP...6 SPECIL FUNCTIONS...7 DISPLYS & WRNINGS... 9 FQ S... 10 SPECIFICTIONS...11 INTRODUCTION Your Medi-Link unit has been designed to provide you with the freedom and peace of mind in that, should you need assistance or HELP, it is available to you 24 hours a day with the simple press of a Button. The modern design of the Medi-Link unit allows it to be installed unobtrusively anywhere and is ready when you need help. HELP can be summonsed by pressing a Button on your personal Pendant or Wristwatch, which you can wear both inside your home or outside in the garden, ready for any emergency, giving you the freedom you enjoy for total control at all times. The Medi-Link unit has been built to the highest of technical standards for the protection of people and property and manufactured to ustralian and International quality standards. Your Medi-Link unit can be supplied with additional fixed or portable Radio Key Pendants, which can be worn or placed around the home as needed. Please contact your supplier for more information. 2

MEDI-LINK FETURES 12V 800mH Rechargeable Battery Lead cid (Part No. 142-014) 3

RDIO KEY PENDNTS Wristwatch, Neck Chain or Fixed Waterproof Pendants 2 Way Long Range Pendants (106-183) Man - Down (Fall Pendant) Wall Mounted Call Points (Wireless) Dementia Radio Proximity Key (100-794) (100-698) (100-821) (100-677) NB: for 2 Way Long Range Medi Diallers only. (915.8MHz to 927.2 MHz) RDIO DETECTORS & WIRELESS KEYPD Universal Reed Switch (Inactivity) (100-529) LUX PIR with inbuilt LED Night Light (Inactivity) (106-174) Wireless Radio Keypad (100-001) WIRELESS PS 240VC SMOKE DETECTORS Wireless PS 240VC Smoke Detector With 9V Rechargeable Backup Battery (100-054) Wireless Interface (for PS 240VC Smoke Detector) (106-177) 4

USING YOUR MEDI-LINK NORML OPERTION Your Medi-Link unit will normally look like this: The MINS ON Light & the CNCEL (GREEN) BUTTON should be ON. The current Day and Time is also display on the LCD display. SETTING THE TIME & DTE The Medi-Link unit has an inbuilt Clock and Calendar that is backed up by the system battery and will remain even in the event of a power failure. If you require the time and day to be changed for any reason then perform the following steps: 1. While the Medi-Link unit is in standard operation mode, press and hold down the CNCEL Button for 10 seconds until Set Time is displayed. 2. Press the HELP Button until the correct hour is displayed. Once the hour is set, press the CNCEL Button to begin setting the minutes. In a similar fashion press the HELP Button until the correct minutes are displayed. 3. fter the minutes have been set, press the CNCEL Button to move onto setting the Year, Month and Day. 4. While in the Set Date menu, press the HELP Button until the correct year is selected. fter the year has been set, press the CNCEL Button to move onto setting the month. Press the HELP Button until the correct month is selected. fter the month has been set, press the CNCEL Button to move onto setting the day. Press the HELP Button until the correct day is selected. 5. Finally, press the CNCEL Button to Exit the Menu and save changes. 5

TO CLL FOR HELP You can make your Medi-Link unit Call for Help by either: Pressing the HELP (RED) BUTTON on the Medi- Link unit. OR 2 The HELP (RED) BUTTON will FLSH rapidly and the Medi-Link unit will start beeping. This is a Pre-larm warning; while this is sounding you can Cancel the Help alarm by pressing the CNCEL (GREEN) BUTTON on the Medi-Link unit. 1 Pressing the Large HELP (RED) BUTTON on your Pendant for 2 Seconds. OR Pressing the front or Side Lever HELP (Panic) Button(s) on your Box Style Pendant for 2 Seconds. 3 If the CNCEL (GREEN) BUTTON is not pressed within the pre-alarm time (10 seconds), then your Medi-Link unit will dial your Monitoring Centre using the telephone line. (NOTE: Your Medi-Link unit will cut off your telephone for the duration of the call to ensure that there is no interference to the call, this will normally take about 15 seconds). When your Monitoring Centre has received the Call, your Medi-Link unit will beep 7 times to let you know that the Call has been received. The HELP (RED) BUTTON will now FLSH slowly every 4 seconds to indicate that your Medi-Link unit has called for Help. 6

SPECIL FUNCTIONS Your Medi-Link unit may have been programmed with one or more special features by your installer, these are described below, check with your Monitoring Company if you have any queries about these or other features. PILL REMINDER Your Medi-Link unit has an inbuilt Clock and Calendar that is backed up by the system battery and will remain even in the event of a power failure. Your Medi-Link unit can be programmed to produce regular warning (Voice Prompt) such as a Medication reminder at a specific time. When the Pill Reminder Timer is active, it will be pre-set by your Installer to provide a warning (Voice Prompt (Chime), This is a personal task reminder from your unit. I repeat, this is a personal task reminder from your unit ), flashes the CNCEL (GREEN) BUTTON for 5 minutes and displays Pill Reminder as a reminder to take your Medication. Pill Reminder Mon, 9:00 You can stop the warning by pressing the CNCEL (GREEN) BUTTON. NOTE: There is no Help message sent to your Monitoring Centre; the warning is a reminder for you only. If you do not press the CNCEL (GREEN) BUTTON, the Pill Reminder will stays on the LCD display. Timer will de-activate and it will not restart until the CNCEL (GREEN) BUTTON is pressed again. You can use this as a useful feature if you wish to change the timer to commence at a different time. If you wish to change the timer to a different interval e.g. Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday to Everyday, then your Monitoring Centre may be able to change this time over the phone or your Installer can change it for you. 7

MINS FIL CHECK POWER Mon, 3:00 MINS FIL Mon, 3:00 Your Medi-Link unit also has a special feature designed to alert you if the power outlet has been knocked out of the socket accidentally. Within 10 seconds of the power outlet being removed, your Medi-Link unit will give 2 warnings (Voice Prompt (Chime), Power to your unit is disconnected. Please check powerpoint connections and switch ) advising that the power has been interrupted or disconnected and needs to be reconnected. SYSTEM CLL REMINDER Your Medi-Link unit also has a System Call Reminder designed to alert you, however should you forget to test your Medi-Link unit. When the System Call Timer is active, it will be pre-set by your Installer to remind you. (Voice Prompt (Chime), Your unit is now due for testing. Please activate your unit to notify us all is well. ). If you wish to change the timer to a different interval e.g. Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday to Everyday, then your Monitoring Centre may be able to change this time over the phone or your Installer can change it for you. INCTIVITY MONITOR Your Medi-Link unit may have been programmed by your Installer to ensure that you have not had an accident and are unable to move and you do not have a Pendant with you to call for Help. The Inactivity Monitor, after a fixed period of time without any activity, will automatically send a Help message to your Monitoring Centre. The Medi-Link unit will produce warning beeps and flash the HELP (RED) BUTTON. 8

DISPLYS & WRNINGS HELP (RED) BUTTON FLSHING QUICKLY WHILE BEEPING Your Medi-Link is about to send a Help message to your Monitoring Centre. HELP (RED) BUTTON FLSHING SLOWLY Your Medi-Link unit has sent a Help message to your Monitoring Centre and is waiting to send the I m O.K message. The CNCEL (GREEN) BUTTON will need to be pressed to send the I m O.K message. FULT DISPLYS CHECK POWER Mon, 3:00 LOW BTTERY Unit LOW BTTERY Pendant No.1 Check Power or Mains Fail - Check and make sure that the MINS Power Pack is plugged in and turned ON at the Power Point. Power has been OFF for too long and Battery is Low/Faulty or the Battery Switch has been Switched OFF - Contact your Installer or Monitor Centre. Pendant No.1 to No.8 Low Battery - Contact your Installer or Monitoring Centre. LOW BTTERY Detector No.1 REPORT FIL Unit LINE FIL Mon, 3:00 CHECK LINE Mon, 3:00 CHECK MOBILE Mon, 3:00 Detector No.1 to No.8 Low Battery - Contact your Installer or Monitoring Centre. Failed to Send/Report a message to your Response Centre - Check and make sure that the telephone lead is plugged in and all normal telephones are working. Contact your Installer or Monitoring Centre. The Telephone Line has failed - Check and make sure that the telephone lead is plugged in and all normal telephones are working (Your Medi-Link Unit will also beep for 25 seconds). Contact your Installer or Monitoring Centre. The Telephone Line has failed - Check and make sure that the telephone lead is plugged in and all normal telephones are working (Your Medi-Link Unit will also beep for 25 seconds). Contact your Installer or Monitoring Centre. The Mobile has failed (NB: Medi-Link Cellular unit only) - Check Sim Card, ntenna and make sure that it is plugged in properly. Check Signal Strength and make sure that it is displaying 1 to 9 on the top right hand corner of the Medi- Link LCD. Contact your Installer or Monitoring Centre. 9

Q Q Q Q Q Q Q FQ S re Pendants Water resistant and can I still shower or bath with them on? Yes - The standard Pendant is not only water resistant but also completely waterproof to IP67 Ratings, far exceeding the required specifications. (Other specialty Pendants may only be water resistant) Should the Medi-Link unit be tested? Yes - Refer to your Installer or the Monitoring Centre. How long does the Pendant s battery last? Pendants use a lithium battery, which lasts between 5 to 7 years under normal conditions with a 10 year shelf life. Can I change the types of Pendants I have installed? Yes - Pendants can be easily changed to suit your wants or needs. Simply refertoyourinstallerorthemonitoring Centre and they can arrange for your Pendant type to be changed. If Mains Power is disconnected, will my Medi-Link unit and normal telephone still operate? Yes - all telephones will still operate normally with a Medi-Link unit; and more importantly, unlike some other products, the emergency open voice will still be fully operational. How long does the Medi-Link unit s Back Up Battery last if Mains Power is disconnected? The Medi-Link unit s Back Up Battery, under normal operating conditions, can last up to 1000 hours (non rechargeable models) and 200 hours (rechargeable models) far exceeding the capacity of some other products on the market (which can be as little as 30 hours). Should I wear my Pendant to bed? Yes - You should wear your Pendant at all times, including when you go to bed. 10

SPECIFICTIONS Medi-Link Unit Dimensions Weight Quiescent Current C Plug Pack (Part No. 840-030) Battery Backup (Part No. 142-014) Radio Receiver Sensitivity Range Transmitter Type Frequency Power Output Conforming Standards IS09001/2000 S4607 S/CIF S002 2005 PTC200 S/CIF S004 PSTN1 TBR21 S2201.4 (C2) S4268 S/NZSCISPR22 FCC 47 Part 15 EN301 489-3 EN55022 Class B EN300 220-1 V1.3.1 EN60950 S/NZS60950.2003 + 1 CE TI/EI/IS-968 IC CS-03 Issue 8 Part 1 235 x 95 x 150 mm 1300 grams (including battery) 5m 17V C 300m with integral earth 12V 800mH (Sealed Rechargeable Lead-cid Battery) Superheterodyne > -110 dbm 50 metres open air (subject to environmental conditions) SWR stabilised 304 MHz (ustralia & New Zealand) 315 MHz (Singapore, US & Canada) 434 & 868 MHz (UK & Europe) < 100 uw (or various international compliances) International Quality manufacturing Standards Personal Response Systems PSTN Interworking (ustralia) PSTN Interworking (New Zealand) Voice Frequency Performance (ustralia) Public Switched Telephone Network (Singapore) Public Switched Telephone Network (UK & Europe) Intruder larm Systems - Wireless Emissions (ustralia & New Zealand) EMC (ustralia & New Zealand) Emissions FCC (US, Canada & Singapore) Emissions EMC (UK & Europe) EMC (EU) Radio Device RF Performance (UK & Europe) Safety Requirements (UK & Europe) Electrical Safety (ustralia & New Zealand) UK Standards US FCC Dialler pprovals Canadian Dialler pprovals WRNING: For safety reasons, only connect equipment with a telecommunications compliance label. This includes customer equipment previously labelled permitted or certified. Copyright SmartLink Division of Ness Corporation Pty Ltd Email: smartlink@ness.com.au Web Site: www.smartlink.com.au To the best of our knowledge, the information contained in this manual is correct at the time of print. SmartLink division of NESS CORPORTION PTY LTD reserves the right to make changes to the features and specifications at any time without prior notice in the course of product development. 11