Installation, Operation, and Maintenance Manual. NRF -25,36,45/NBF -25,36, and 45 Circulator

Similar documents
Automatic Water System Pump SERIES

Instruction Manual. Bell & Gossett ecocirc wireless Potable Hot Water Recirculation Kit

Installation and operating instructions. E.2 Series high efficiency circulator

E.2 series high efficiency circulator. Installation and operating instructions

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

569, 570, 571, 572 Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

OWNERS GUIDE TO INSTALLATION AND OPERATION

Flygt 3153, 3171, 3202, 3301, 3315, 5100, Replacing Cooling Liquid In Pumps with Cooling Jackets

568X, 587X, 588X Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

569, 570, 571, 572 Series

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

INSTALLATION INSTRUCTIONS

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INSTALLATION & OPERATING INSTRUCTIONS

INSTRUCTION AND REPAIR MANUAL

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

57" Fiberglass Exhaust Fan with Cone

C7 Series Split System Uncased Indoor Coils

QUICK PRIME INSTALLATION AND SERVICE MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

OPERATING AND INSTALLATION MANUAL

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Models Series Series

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

QUICK PRIME INSTALLATION AND SERVICE MANUAL

HIGH EFFICIENCY CIRCULATOR INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

Inverted Bucket Steam Traps

Astro 2 circulator models. Installation and operating instructions

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

INSTALLATION INSTRUCTIONS

OPERATING AND INSTALLATION MANUAL

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

INSTALLATION INSTRUCTIONS

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

LS Condensate Removal Pump Installation, Operation and Service Instructions

SuperKlean Washdown Products

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Panel Fan Series Operators Manual (Galvanized and Polymer)

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

INSTRUCTION MANUAL DN0136 REVISION D

Refrigerant Recovery Machine. Model No Operating Manual

20-GALLON PARTS WASHER OWNER S MANUAL

CHAMPION PUMP OWNER S MANUAL

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Manual CARBONATOR With Plain-Water Booster

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

LC Series - Light Commercial Pump Station Installation and Operation Manual

TITAN FLOW CONTROL, INC.

Instruction Manual Hydraulic Crimping Tool

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

USER MANUAL UN-200V / UN-200VH

Models Series Series

SECTION STEAM CONDENSATE PUMPS

Installation and Operating Instructions for Davey BF Series Pressure Booster Systems with Flow Switch Control

Elite Primer Baldor Series External Pond Pump

IMpORTANT SAFETy INSTRUcTIONS

SMF PUMP OWNER S MANUAL

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

22In. Oscillating Pedestal Fan. Owner s Manual

3.5-GALLON PARTS WASHER OWNER S MANUAL

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

Panel Fan Series Operators Manual (Galvanized and Polymer)

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Operating instructions

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

High-Velocity Floor Fan

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

HYDROGEN SULFIDE REMOVAL SYSTEMS

Grinding mill MISTRAL 50L (art. 650P)

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

Transcription:

Installation, Operation, and Maintenance Manual NRF -25,36,45/NBF -25,36, and 45 Circulator

Table of Contents Table of Contents Introduction and Safety...2 Introduction...2 Requesting other information...2 Safety...2 Safety terminology and symbols...3 User safety...3 Environmental safety...5 Product warranty...5 Transportation and Storage...7 Inspect the delivery...7 Inspect the package...7 Inspect the unit...7 Pump storage requirements...7 Product Description...8 General description...8 Operational specifications...8 Installation...9 Pump location guidelines...9 Pump orientation...9 Change the conduit position...9 Install suction and discharge flange connectors on the pipe ends...1 Connect the wiring...1 Wiring diagram...11 Install a check valve...12 Commissioning, Startup, Operation, and Shutdown...13 Pump operation precautions...13 Prepare the system...13 Start the pump...13 Select the speed...13 Performance characteristic curve...14 Maintenance...16 Periodic inspection...16 Remove the pump from an existing system...16 Troubleshooting...17 Pumping system troubleshooting...17 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 1

Introduction and Safety Introduction and Safety Introduction Purpose of this manual The purpose of this manual is to provide necessary information for: Installation Operation Maintenance CAUTION: Read this manual carefully before installing and using the product. Improper use of the product can cause personal injury and damage to property, and may void the warranty. NOTICE: Save this manual for future reference, and keep it readily available at the location of the unit. Requesting other information Special versions can be supplied with supplementary instruction leaflets. See the sales contract for any modifications or special version characteristics. For instructions, situations, or events that are not considered in this manual or in the sales documents, please contact the nearest Xylem representative. Always specify the exact product type and identification code when requesting technical information or spare parts. Safety The operator must be aware of safety precautions to prevent physical injury. Any pressure-containing device can explode, rupture, or discharge its contents if it is over-pressurized. Take all necessary measures to avoid over-pressurization. Operating, installing, or maintaining the unit in any way that is not covered in this manual could cause death, serious personal injury, or damage to the equipment. This includes any modification to the equipment or use of parts not provided by Xylem. If there is a question regarding the intended use of the equipment, please contact an Xylem representative before proceeding. This manual clearly identifies accepted methods for disassembling units. These methods must be adhered to. Trapped liquid can rapidly expand and result in a violent explosion and injury. Never apply heat to impellers, propellers, or their retaining devices to aid in their removal. Do not change the service application without the approval of an authorized Xylem representative. CAUTION: You must observe the instructions contained in this manual. Failure to do so could result in physical injury, damage, or delays. 2 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Introduction and Safety Safety terminology and symbols About safety messages It is extremely important that you read, understand, and follow the safety messages and regulations carefully before handling the product. They are published to help prevent these hazards: Personal accidents and health problems Damage to the product Product malfunction Hazard levels Hazard level Indication DANGER: A hazardous situation which, if not avoided, will result in death or serious injury A hazardous situation which, if not avoided, could result in death or serious injury CAUTION: A hazardous situation which, if not avoided, could result in minor or moderate injury NOTICE: A potential situation which, if not avoided, could result in undesirable conditions A practice not related to personal injury Hazard categories Hazard categories can either fall under hazard levels or let specific symbols replace the ordinary hazard level symbols. Electrical hazards are indicated by the following specific symbol: Electrical Hazard: These are examples of other categories that can occur. They fall under the ordinary hazard levels and may use complementing symbols: Crush hazard Cutting hazard Arc flash hazard User safety General safety rules These safety rules apply: Always keep the work area clean. Pay attention to the risks presented by gas and vapors in the work area. NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 3

Introduction and Safety Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash hazards. Always bear in mind the risk of drowning, electrical accidents, and burn injuries. Safety equipment Use safety equipment according to the company regulations. Use this safety equipment within the work area: Hard hat Safety goggles, preferably with side shields Protective shoes Protective gloves Gas mask Hearing protection First-aid kit Safety devices Electrical connections Precautions before work Wash the skin and eyes NOTICE: Never operate a unit unless safety devices are installed. Also see specific information about safety devices in other chapters of this manual. Electrical connections must be made by certified electricians in compliance with all international, national, state, and local regulations. For more information about requirements, see sections dealing specifically with electrical connections. Observe these safety precautions before you work with the product or are in connection with the product: Provide a suitable barrier around the work area, for example, a guard rail. Make sure that all safety guards are in place and secure. Make sure that you have a clear path of retreat. Make sure that the product cannot roll or fall over and injure people or damage property. Make sure that the lifting equipment is in good condition. Use a lifting harness, a safety line, and a breathing device as required. Allow all system and pump components to cool before you handle them. Make sure that the product has been thoroughly cleaned. Disconnect and lock out power before you service the pump. Check the explosion risk before you weld or use electric hand tools. Follow these procedures for chemicals or hazardous fluids that have come into contact with your eyes or your skin: Condition Chemicals or hazardous fluids in eyes Action 1. Hold your eyelids apart forcibly with your fingers. 2. Rinse the eyes with eyewash or running water for at least 15 minutes. 3. Seek medical attention. 4 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Introduction and Safety Condition Chemicals or hazardous fluids on skin Action 1. Remove contaminated clothing. 2. Wash the skin with soap and water for at least 1 minute. 3. Seek medical attention, if necessary. Environmental safety The work area Always keep the station clean to avoid and/or discover emissions. Waste and emissions regulations Observe these safety regulations regarding waste and emissions: Appropriately dispose of all waste. Handle and dispose of the processed liquid in compliance with applicable environmental regulations. Clean up all spills in accordance with safety and environmental procedures. Report all environmental emissions to the appropriate authorities. Do NOT send the product to the Xylem manufacturer if it has been contaminated by any nuclear radiation. Inform Xylem so that accurate actions can take place. Electrical installation For electrical installation recycling requirements, consult your local electric utility. Recycling guidelines Always follow local laws and regulations regarding recycling. Product warranty Coverage Limitations Xylem undertakes to remedy defects in products from Xylem under these conditions: The faults are due to defects in design, materials, or workmanship. The faults are reported to an local sales and service representative within the warranty period. The product is used only under the conditions described in this manual. The monitoring equipment incorporated in the product is correctly connected and in use. All service and repair work is done by Xylem authorized personnel. Genuine Xylem parts are used. Only Ex-approved spare parts and accessories authorized by an EX-approved Xylem representative are used in Ex-approved products. The warranty does not cover defects caused by these situations: Deficient maintenance Improper installation Modifications or changes to the product and installation made without consulting an Xylem authorized representative Incorrectly executed repair work Normal wear and tear NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 5

Introduction and Safety Warranty claim Xylem assumes no liability for these situations: Bodily injuries Material damages Economic losses Xylem products are high-quality products with expected reliable operation and long life. However, should the need arise for a warranty claim, then contact your local sales and service representative. 6 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Transportation and Storage Transportation and Storage Inspect the delivery Inspect the package Inspect the unit 1. Inspect the package for damaged or missing items upon delivery. 2. Note any damaged or missing items on the receipt and freight bill. 3. File a claim with the shipping company if anything is out of order. If the product has been picked up at a distributor, make a claim directly to the distributor. 1. Remove packing materials from the product. Dispose of all packing materials in accordance with local regulations. 2. Inspect the product to determine if any parts have been damaged or are missing. 3. If applicable, unfasten the product by removing any screws, bolts, or straps. For your personal safety, be careful when you handle nails and straps. 4. Contact your sales representative if anything is out of order. Pump storage requirements Storage requirements depend on the amount of time that you store the unit. The normal packaging is designed only to protect the unit during shipping. Length of time in storage Upon receipt/short-term (less than six months) Long-term (more than six months) Storage requirements Store in a covered and dry location. Store in a covered and dry location. Store the unit free from heat, dirt, and vibrations. NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 7

Product Description Product Description General description Pump application The NRF/NBF circulator pump has these features: System liquid lubricated bearings Non-overloading permanent split capacitor motor with thermal or impedance protection Quiet operation Nonsubmersible California Proposition 65 warning! This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. You can use this pump for these types of applications: Water circulating applications in hydronic and solar systems. Indoor use only Do not use in swimming pools and marine areas. Xylem recommends that you use bronze or stainless steel booster pumps for pumping potable water. For other applications, contact your local Xylem representative. Operational specifications Operational Limits These pumps are designed to pump liquids compatible with their iron or bronze body constructions. Parameter Value Maximum operating pressure Maximum operating temperature 15 PSI (1 bars) 225 F (17 C) Electrical Rating 115V, 6Hz, 1Ø; 23V, 6Hz, 1Ø (single phase power) 8 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Installation Installation Pump location guidelines Guideline Make sure that the space around the pump is sufficient. Explanation/comment This facilitates ventilation, inspection, maintenance, and service. Xylem recommends that the service valves on the suction and discharge of all circulators are installed so they can be serviced or replaced without draining the system. Pump orientation You can install this pump to discharge up, down, left, or right. However, make sure that you install the pump according to these pump orientation guidelines: Only install the pump with the motor shaft horizontal. The arrow on the pump body must point in the direction of the flow. You must position the conduit box on the top or to the side of the motor housing. If you need to change the position of the conduit box, change it before you start the installation. If the pump is already installed, see Remove the pump from an existing system (page 16) before proceeding. Change the conduit position CAUTION: Burn or projectile hazard. Make sure the power is turned off before placing anything inside the discharge opening to move the impeller. Figure 1: Conduit box position 1. While supporting the motor assembly, use a 3/16 wrench in order to remove the four 1/4-2 Allen screws. 2. Remove the motor assembly from the pump body and rotate it to the desired position. 3. Replace the Allen screws and tighten them evenly in a diagonal method to 6 in-lbs. 4. Check to see that the impeller turns freely. Insert your finger in the discharge port of the pump body until you can feel the impeller and rotate it with your fingertip. The arrow on the pump body points in the direction of the discharge. If the impeller does not turn easily, repeat the disassembly/ reassembly process. NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 9

Installation Install suction and discharge flange connectors on the pipe ends Burn hazard. Make sure that each flange gasket remains seated in the flange groove during and after installation. Burn hazard. Do NOT re-use old gaskets. When disassembling a gasketed joint, always use a new gasket upon reassembly. 1. Use pipe hangers near the pump in order to support the suction and discharge piping. This minimizes pipe strain on the pump. 2. Install the flange gaskets between the pump body flanges and the suction and discharge pipe flanges. Use a 7/16 in. x 1-1/2 in. capscrew and a matching nut in order to connect the pump to the flanges. The use of PTFE tape sealer or a high quality thread sealant is recommended. CAUTION: Burn hazard. The use of PTFE impregnated pipe and PTFE tape on pipe threads provides lubricity which can lead to overtightening and breaks. Do not overtighten. 3. Line up the vertical and horizontal piping so that the bolt holes in the pump flanges match the bolt-holes in the pipe flanges. NOTICE: Do not attempt to spring the suction or discharge lines in position. This may result in unwanted stress in the pump body, flange connections and piping. The code for Pressure Piping (ANSI B31.1) lists many types of supports available for various applications. 4. Evenly torque the suction and discharge flange bolts to 115 in-lbs (12 Nm). Burn hazard. Make sure that the flange bolts or ring nuts have been properly tightened and that the solder connections do not leak. Connect the wiring Disconnect and lock out electrical power before installing or servicing the pump. Electrical Hazard: Make sure that all connections are secure and the conduit box cover is closed before you connect the electrical power. 1 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Installation CAUTION: Make sure that all wiring is rated to withstand at least 194 F (9 C). 1. Remove the screws that secure the conduit box cover. 2. Lift off the cover. 3. Attach the appropriately sized connector to the hole in the side of the conduit box. 4. Wire the motor to a single phase power source that matches the electrical rating on the pump nameplate. Use a minimum of 14 AWG copper electrical wire in order to accomplish this. Refer to your local code for wiring restrictions. Use the size of electrical wire as dictated by local code. 5. Connect the earth (ground) wire to the inside of the conduit box with one of the green screws provided inside the box. Electrical Hazard: Make sure that the equipment is properly grounded. Use a grounded metal conduit, or ground the pump back to the service using a correctly sized copper conductor. Connect the ground wire to the green grounding screw in the wiring compartment. The circulators are thermally protected by impedance or on-winding thermal protectors and do not require external overload protection. Wiring diagram S 1 4 L N 3 2 1. Fusible disconnect or circuit breaker by others 2. Pump motor thermally protected 3. Pump motor 4. To remote control, if required Figure 2: Typical wiring installation schematic (1Ø power source) NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 11

Installation 1 2 1. Line lead 2. Green ground screw Figure 3: Conduit box wiring detail Install a check valve The NRF/NBF-25 pump discharge nozzle is machined to accept check valve P/N P86596. 1. Insert the O-ring end of the check valve into the discharge port of the pump body. 2. Hand press the check valve body into place until it snaps into position. 12 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Commissioning, Startup, Operation, and Shutdown Pump operation precautions Commissioning, Startup, Operation, and Shutdown Do NOT exceed the maximum working pressure of the pump. This information is listed on the nameplate of the pump. The heating of water and other fluids causes volumetric expansion. The associated forces can cause the failure of system components and the release of high-temperature fluids. In order to prevent this, install properly sized and located compression tanks and pressure-relief valves. Failure to follow these instructions can result in serious personal injury or death, or property damage. Make sure that all components are properly guarded or insulated when operating at extremely high or low temperatures. Electrical connections must be made by certified electricians in compliance with all international, national, state, and local rules. Electrical Hazard: Do NOT install this pump in swimming pools or marine areas. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Prepare the system 1. Clean and drain closed heating and cooling systems. 2. Refill the system with clean water. Start the pump The system fluid ph must be maintained between 7 and 9. Pressurize the pump body slowly while you check for leaks at all gasketed joints and solder connections. Do not start pump until you fill and vent the system. 1. Vent air from the system by means of an air vent located at a high point in the system. The system must be completely vented prior to pump operation. 2. Make sure the pump is filled with clean water. Do not run the pump dry. Pump operation without water circulation can result in pump and motor damage. Select the speed The pump can be run at different speeds to suit the required operating conditions. Select the speed by adjusting the three-position switch on the side of the terminal box. NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 13

Commissioning, Startup, Operation, and Shutdown 1. Minimum speed 2. Medium speed 3. Maximum speed Performance characteristic curve Select the speed that best matches the design performance for the system or loop for which you are installing the pump. (kpa) (M) (FT) 4 CENTRIFUGAL PUMP SERIES NRF-36 1 1 3 SPEED 3 2 SPEED 2 5 5 1 SPEED 1 1 2 3 4 5 6 (gpm) 5 1 (m3/hr) 1 2 Figure 4: Centrifugal pump series NRF-36 3 (l/s) (kpa) (M) (FT) 4 1 1 3 SPEED 3 2 SPEED 2 5 5 SPEED 1 1 1 2 3 4 5 6 5 1 (gpm) (m3/hr) 1 2 Figure 5: Centrifugal pump series NRF-45 3 (l/s) 14 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Commissioning, Startup, Operation, and Shutdown (kpa) (M) (FT) 4 CENTRIFUGAL PUMP SERIES NRF-36 1 1 3 2 5 5 SPEED 3 1 SPEED 2 SPEED 1 1 2 3 4 5 6 5 1 (gpm) (m3/hr ) 1 2 3 Figure 6: Centrifugal pump series NRF-25 with check valve (l/s) (kpa) (M) (FT) 4 CENTRIFUGAL PUMP SERIES NRF-36 1 1 3 2 5 5 SPEED 3 1 SPEED 2 SPEED 1 1 2 3 4 5 6 5 1 (gpm) (m3/hr) 1 2 3 (l/s) Figure 7: Centrifugal pump series NRF-25 without check valve NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 15

Maintenance Maintenance Periodic inspection It is recommended that periodic inspections be made to check for potential problems with the pump. If any leaks or evidence of leakage is present, repair or replace the unit. Remove the pump from an existing system Make sure that the pump is isolated from the system and that pressure is relieved before you disassemble the pump, remove plugs, open vent or drain valves, or disconnect the piping. Always disconnect and lock out power to the driver before you perform any installation or maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical injury. Burn hazard. Do NOT re-use old gaskets. When disassembling a gasketed joint, always use a new gasket upon reassembly. 1. Close the valves on the suction and discharge sides of the pump. If no valves are installed, you might need to drain the system. 2. Drain the system: Allow all system and pump components to cool before you handle them to prevent physical injury. a) Allow the water to cool to at least 1 F (38 C). b) Take precautions against water damage, and then open the drain valve. c) Leave the drain valve open until servicing is complete. Electrical Hazard: Make sure the electrical power is not present at the motor leads before continuing. 3. Loosen the screws on the conduit box and remove the cover. 4. Disconnect the electrical supply lines to the pump. 5. Relieve pressure in the pump body. Pressurized device. Relieve any contained pressure in the pump body by loosening the flange bolts and shifting the pump assembly slightly to allow the pressurized water to escape. 6. Remove the flange nuts and bolts or loosen the union ring nuts. Then remove the pump from the piping 16 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Troubleshooting Troubleshooting Pumping system troubleshooting Symptom Cause Remedy There is no circulation Air-bound system Vent the system The impeller or piping is clogged. The system valve is closed. The electrical circuit for the pump is broken. Locate and remove the obstruction. Open Check all related low and line voltage circuits. There is inadequate circulation. Air-bound system Vent the system. The impeller or piping is clogged. The impeller is damaged. The pump is too small. Partially air-bound pump Improper motor speed Locate and remove the obstruction. Replace pump. Replace the pump if single speed. If three speed switch to higher setting. Vent the pump casing. Check the wiring and the voltage. There is pump or system noise. Entrained air Vent the system. There is premature failure of pump components. Pump cavitation Excessive water velocity Pipe vibration Improper pump (size/type) Improper pump location Excessive water treatment Pump operating close to or beyond the end point of curve. Excessive piping load Lower the pump or raise pressure or relocate (see note below). Install balancing cocks or parallel piping. Provide adequate pipe support. Replace Relocate Check the manufacturer s instructions. Balance the system. Provide proper pipe support NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual 17

Troubleshooting Symptom Cause Remedy There are seal failures within a 1 year period or less in a closed system. Excessive dirt, sand and oxides Excessive or improper water treatment Clean the system. Check for proper water treatment recommendations from pump manufacturer. There is seal pitting, oxygen corrosion, magnetic iron oxide. Pump Cavitation: 1. Improper selection 2. Compression tank location Excessive temperatures Pumps run without fluid Caused by wear and excessive amounts of free oxygen. Fresh water feeding carries oxygen into the system. 1. Check pump operation on its curve overloading 2. High head pump must have compression tank on suction side of pump. Check the type of seal and maximum operating temperature from the manufacturer. Pumps must be primed before operation. Check if system has a constant leak. NOTICE: Cavitation is identified by low rumbling or sharp rattling noises. This situation is created by the lack of available net positive suction head (NPSH). The pressure at some point in the pump falls below the vapor pressure of the water causing flashing and the formation of bubbles, which are carried into the volute where the higher pressure causes them to implode. This can eventually destroy the pump. 18 NRF -25,36,45/NBF -25,36, and 45 Circulator Installation, Operation, and Maintenance Manual

Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We're 12,5 people unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 15 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Xylem Inc. 82 N. Austin Avenue Morton Grove, IL 653 Tel. 1-847-966-37 Fax 1-847-965-8379 www.xyleminc.com/brands/ bellgossett Visit our Web site for the latest version of this document and more information The original instruction is in English. All non- English instructions are translations of the original instruction. 212 Xylem Inc. Bell & Gossett is a trademark of Xylem Inc or one of its subsidiaries. P8623_E_en.US_212-9_IOM.NRF