Product Information Motor and machine protection

Similar documents
ANTI-CONDENSATION HEATERS

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Heaters for. Hot Runner Systems. COIL Heaters l MICRO TUBULAR COIL Heaters l. The first choice, to last...

Braided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding

Flexible Heaters. of Silicone Rubber & Kapton

Lexan* Resin 3412R Europe-Africa-Middle East: COMMERCIAL

SolderSleeve Shield Terminators

Lexan* Resin 121 Europe-Africa-Middle East: COMMERCIAL

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Application Engineering Note. Importance of Jacket Crimping

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

GLED INSTALLATION INSTRUCTIONS

Understanding Etched Foil Flexible Heaters

HEATERS & SENSORS INC. - CATALOG

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Mineral Insulated Band Heater

Mineral Insulated Band Heaters

GLED INSTALLATION INSTRUCTIONS

RG1,5SA Self Adhesive

CABLE & HOSE PROTECTION PRODUCT OVERVIEW

Energy Saving Band Heaters

High Performance Heater with More Efficient Heat

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

1SC-SSC Splice Connection Kit Installation Instructions

MARATHON HEATER. File # E Made in USA

temperature Controllers

HRS Hand Rail System 1

S1L Series: Metal Bottom

Kapton and Silicone Rubber Flexible Heaters

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

Silicone Rubber Heaters FLEXIBLE HEATERS

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Temperature rating. Printer information

CYLINDER PLASTICS CERAMIC BAND HEATERS. Main technical characteristics: Mechanics. Electrics

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

BAND HEATERS TYPICAL APPLICATIONS: SPECIAL OPTIONAL FEATURES: Plastic Injection Molding. Two piece construction. Plastic, Food, or Candy Extruders

Installation Procedure and Inspection Criteria for SolderSleeve Coaxial Cable Terminators on Coaxial Cables Rated For At Least 125 C.

Flame Retardant Polyethylene Tubing

Pneumatic Tubing POLYTUBING O.D. 5/32"

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

onlinecomponents.com 144

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

W A T L O W. Layers Of Dielectric Glass

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

Large-scale fire test for interior materials of the Korean high speed train

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

Beck. The differential pressure transmitter for air

Sensor and transducer cables

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR ELECTRIC DRIVING POWERED BY SILICONES

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

PIPE MANUFACTURING CO.

Lloyd s Register Type Approval System Test Specification Number 3

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type D)

3D Industries Aluhotends

Y S L V i z L i t e 3 0 2

Photovoltaic Cables EN H1Z2Z2-K

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

IPVB EC inline power venter

The Quality Connection. BETAflam Fire Resistant Safety Cables

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

Heating Tapes/Mats HEATING TAPES HEATING CORDS HEATING MATS DRUM HEATERS GREAT FOR HEATING SMALL TUBES! MOISTURE RESISTANT!

ENERVEX GSV GREASE FAN

Cartridge Heaters. Components. Application Guidelines

SolderSleeve Insulated Electrical Termination Devices

III.DRAINAGE. This section describes the use of geotextiles in underdrains for two different field conditions:

AWE Manhole size 500mm - mounted at pharmaceutical vessel

GSV 9-16 Grease Fan for Solid Fuel Applications. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

AlarmLine Addressable Linear Heat Detector

Stego accessories for cabinets

Heat Shrink/Cable Markers Performance Labels Self-Laminating Labels Pre-Printed Wire and Cable Markers

Traction Cable Radox 3 GKW

Heating Mats and Jackets. innovations in heat tracing

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867

Here Comes the Sun!!!

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Caledonian Flame Retardant Coaxial Cables

Descriptive Report and Test Results

Thermal Management Products & Accessories for Enclosures

Cartridge/Insertion Heaters

Flexible Heaters. Fullchhance Silicone Heater Fullchance Silicone Heater.

SECTION PLUMBING EQUIPMENT

Cartridge Heaters. Hi-Density Cartridge Heaters. Features. To order, call or shop online at omega.com SM

Transcription:

- Basic information The REISSMANN Sensortechnik heater bands were specifically designed for the electric motor industry. These heater bands are delivered as a finished product, in various combinations, of length and power output. - Application The heater bands prevent condensation in electric motors and also protect against frost damage. If condensation occurs inside the motor, creepage currents and short circuits may occur. - Advantages exclusive usage of silicone-free material prevention of outgassing of silicone protection of people and equipment, from dangerous gases very flexible design facilitates the matching of product to application Fig. 1: heater band type C - Construction The carrier material consists of a glass yarn and a resistance wire that is wound round the glass yarn. Afterwards the glass yarn is insulated by Teflon (Fig. 2). The junction between the lead-in and the resistance wire are insulated on both sides with shrink tubes. For protection against damage, from external sources, the entire heater band system is sewn into a fiberglass hose or sleeve (Fig. 1 and 3). The sewing in of the lead-in, at the end of the fiberglass hose, gives additional strain relief at the junction between the Teflon insulated resistance winding and the lead-in. - Certification VDE: 40029602 UL: E325880 Fig. 2: heater band type A 1-5

- Technische Daten Rated supply voltage 110 VAC/230 VAC 1) Insulation of the resistance winding Outer insulation fiber glass hose (mechanical protection) Testing of insulation 1) several currents available on demand Teflon (PTFE), 52% overlap, Wall thickness 0,20 mm fiber glass hose, wall thickness about 0.30 mm 2,5 kv/50 Hz; optional 8KV (type A) Rated temperature - 55 C bis + 180 C Alloy of the resistance resistance wire NiCr alloy Tolerance ± 10% tolerance of power Lead-in: length: variable in mm Teflon-strand; UL File 1199 max. operation voltage 600 V AWG 20/7 end connections are 10 mm partially bared Insulation of the junction of resistance winding and the lead-in: Kynar shrink tube; strengthened wall thickness after shrinking 0.5 mm, self-extinguishing according to UL 224, VW-1; MIL-I-23053/5 class 8; dielectric strength 43 kv/mm Resistance wire: NiCr 80/20 pure according to DIN 17470 material 2.4869 melting temperature 1400 C Contact: material: nickeled steel temperature limit T = 300 C manufactured according to DIN 46228 T2 B 1,5-7 Fig. 3: heater band type C Carrier material/fiber glass filament: fiber type E-Glas (Textilglas) application temperature limit at 450 C reaction to fire according to DIN 4102 noncombustible 2-5

Standard Standard types: types: length of bands / m voltage U/V power P/W 0,203 110 8 0,203 230 8 0,305 110 22 0,305 230 25 0,432 110 27 0,432 230 26 0,686 110 21 0,686 230 21 0,686 110 40 0,686 230 40 0,762 110 25 0,762 230 26 1,016 110 39 1,016 230 42 1,067 110 50 1,067 230 54 1,473 110 67 1,473 230 65 1,702 110 103 1,702 230 99 Insulation of the resistance winding: material: PTFE specific density 1.6-1.8 g/cm³ working temperature: -270 C up to +260 C thermal stability: up to +320 C thickness 0.1 mm flame retardant according to UL 94 V-0 Fiber glass hose: consists of silicate glass non-alkaline high mechanical tensile strength non-combustible, softening point +550 C UL File 151092 self-extinguishing according to UL 1441 VW-1 Sewing thread 1: meta-aramid (Nomex) highly temperature-resistant short-term up to + 360 C applicable, not melting non-flammable, self-extinguishing Sewing thread 2: glass sewing consisting of 100% glass fiber Teflon coating Heater band classes: length of heater bands from 0.2 m to 2 m for design B and C length of heater bands from 0.2 to 7.5 m for design A heating power from 8 W to 110 W for design B and C heating power from 4 W to 300 W for design A rated supply voltage of the heater bands according to the heating power 230 VAC, 110 VAC or 440 VAC Value of resistance calculated from the requested heating power. 3-5

Product Information Order nomenclature: H 23/ 040/ 068 Heater band type: Identification max. rated input AC voltage: 11 = 11 0V 23 = 230V 44 = 440 V Max. power P = 8 W up to 110 W valid for design B and C P = 4 W up to 300 W valid for design A 040 = power = 40W length of heater band: 203 mm up to 2000 mm for design B and C 203 mm up to 7500 mm for design A length x 10 [mm]: 068 -> length = 680mm Design: A: single folded insulated heating pipe, radial non heating ends lead-in on opposite sides B: twice folded insulated heating pipe, radial non heating ends lead-in on same side C: triple folded insulated heating pipe, axial non heating ends lead-in on opposite sides length of non-heating ends 500 mm up to 999mm length x 100 [mm]: 05 -> length = 500mm C 05 4-5

Responsibility: No responsibility will be accepted for thermistors which have not been installed and tested according to the relevant standards as previously listed in our data sheet. Due to the ongoing research and development program, product specification may be subject to change, at the manufacturers discretion. For further advice and information contact: 5-5