Platen Heater Pad Replacement

Similar documents
Replacing a Gun Thermostat

NHR-25 Feed Hopper with Agitator

Non-RTD Hot Melt Hose Replacement

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

HR Powder Feed Hopper

Rhino AB Upper Check Valve Replacement

Audi-Larm Audible Alarm

ColorMax Cyclone Cleaning Kit

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

Basin Mixer. Installation & Aftercare Instructions. Please retain for future reference.

Pole Mounting System Installation & Certification Manual

569, 570, 571, 572 Series

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Heat Exchanger Block Replacement Instructions

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

Installation Instructions

569, 570, 571, 572 Series

STONE TROUGH CONSOLE SINK

BASIN MIXERS INSTALLATION & AFTERCARE INSTRUCTIONS

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

Single-Control Lavatory Faucet

RYLE WIDESPREAD FAUCET INSTALLATION

BMW E36 Thermostat Removal And Coolant Flush

KITCHEN FAUCET COS-KF222C

Operation, Maintenance and Installation Manual

TARVER SINGLE HOLE FAUCET INSTALLATION

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Installation Instructions Part No , Part No Part No

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with T-style cordsets.

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

PAGOSA SINGLE HOLE FAUCET INSTALLATION

INSTALLATION INSTRUCTIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Section 11. Electrical System. 42--CF200--MA--08 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

Crown Boiler Company

FOR USE BY QUALIFIED PERSONNEL ONLY

! WARNING. Before using product, read and understand instructions.

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

HDLV 55-Gallon Powder Drum Unloader

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

MAKAI WIDESPREAD FAUCET INSTALLATION

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

CBT Bowl & wrap replacement

Heat Exchanger Tube Change Procedure

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

TS-49 PART # DPEC DATE: REVISED:

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

DELEVINGNE WIDESPREAD FAUCET INSTALLATION

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Single-Control Bathroom Sink Faucet

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

INSTALLATION. Glass Panel Doors (select models) CAUTION

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

DRAIN WATER TEMPERING INSTALL

WATTS WALL-MOUNT WIDESPREAD BATHROOM FAUCET INSTALLATION

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

BROEG SINGLE HOLE FAUCET INSTALLATION

Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

TECHNICAL DATA. Wet 26a. February 22, 2009

User s Manual and Operating Instructions

Instant Hot Water Dispenser Owner s Manual

INSTALLATION INSTRUCTIONS

Installation Instructions

LUDGATE SINGLE HOLE FAUCET INSTALLATION

User s Manual and Operating Instructions

EDISON DUAL HANDLE VESSEL SINK FAUCET

HD Kompakt Service Manual

TECHNICAL INSTRUCTIONS

Model/Sprinkler Identification Numbers

INSTALLATION INSTRUCTIONS

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

INSTALLATION GUIDELINES

Installation Instructions

HE120, HE160 Humidifier Installation Kit

Installation Instructions

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

Light Duty Commercial Electric Voltage and Wattage Conversion Instructions

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

EUTECTIC EC-20 OIL-FIRED WATER BOILERS/NO. 2 OIL ASSEMBLY INSTRUCTIONS EUTECTIC EC-20 ASSEMBLY GUIDE

Handshower, Hose & Handshower Accessories

INSTALLATION INSTRUCTIONS

Installation Instructions

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

SWIVEL HEAD WASTE AND OVERFLOW INSTALL

CAOL VESSEL SINK FAUCET INSTALLATION

Spare parts list. Hydraulic compactor RC

Transcription:

Instruction Sheet P/N Platen Heater Pad Replacement WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. 1. Description The Nordson platen heater pads are an integral part of the 5000 Series Drum Melters. This instruction sheet describes the replacement of the platen heater pads. Six heater pads are mounted underneath the follower plate. It is recommended to review your 5000 Series Drum Melter manual before performing the following replacement procedure. CAUTION: Use only original Nordson replacement parts. The use of non-nordson platen heater pads may result in leakage. Material Required Gather the following items before replacing the platen heater pads: A piece of sheet metal or similar heat-resistant material at least the size of the platen diameter to protect the frame base plate. Wood blocks or similar items to secure and support the crossover in place. Nordson platen heater pads. For part number information, refer to the list of replacement platen heater pads in your system manual. TFE joint sealant (included with replacement heater pad) Heat conductive paste Never Seez Torque wrench If a material drum is installed on the unit, remove the drum as described in the Drum Changing section of your system manual. 1998 Nordson Corporation

2 Platen Heater Pad Replacement 2. Heater Pad Replacement Before replacing the heater pads, perform the following steps: 1. Place a piece of heat-resistant material on the frame or across the drum hold-down assembly under the platen to support the platen assembly. 2. Use the elevator control valve to lower the platen to within 12.7 cm (5 in.) of the heat-resistant material. 3. Secure the crossover in place. Cover Plate Removal See Figure 1. 2 3 2 3 1. If the defective heater pad (4) is on the pump/manifold side of the platen, remove both cover plates (1) by removing all hex head screws (2) and washers (3). 1 4 If the defective heater pad is on the opposite side of the platen, remove the hex head screws (2) and washers (3), securing that half of the cover plate (1) to the follower plate. 2. See Figure 2. Carefully remove the cover plate half (halves) to expose the wiring connections. Fig. 1 Cover Plate Removal 1. Cover plate 2. Hex head screw 3. Washer 4. Heater pad 4601118 If the defective heater pad (7) is on the pump/manifold side of the platen, loosen the manifold clamp nut and remove or reposition the clamp as necessary (not shown). Use a flat blade screwdriver or similar tools to pry the pump manifold up slightly. 3. Remove the thermostat (1) and the securing screws, if the thermostat is located on a defective heater pad (7). 4. Remove the RTD sensor (2), its cover plate, and securing screws, if the sensor is located on a defective heater pad. 1998 Nordson Corporation

Platen Heater Pad Replacement 3 1 2 9 3 WARNING TAG 4 8 5 6 7 Fig. 2 Platen Assembly and Heater Pad 1. Thermostat 2. RTD sensor 3. Column support 4. Hex head screw 5. Cover plate 6. Follower plate 7. Heater pad 8. Heater wire connecting posts 9. Joint sealant 4601120 Heater Pad Removal Before removing the defective heater pad, make sure the heater plate is supported from beneath. 1. Disconnect the wires from the heater wire connecting posts (8). 2. Remove the three socket head cap screws (not shown) that secure the heater pad (7) to the follower plate (6). 3. Lower the defective heater pad away from the follower plate. 4. Remove traces of joint sealant (9) from the bottom of the follower plate (6) where the defective heater pad was in place. 5. Repeat the above steps for each defective heater pad. 1998 Nordson Corporation

4 Platen Heater Pad Replacement Heater Pad Installation To install the new heater pad, perform the following steps: 1. Apply fresh joint sealant (9) to the top surface of the new heater pad (7), creating a completely sealed ring where it mates with the follower plate (6). 2. Position the new heater pad (7) in place under the follower plate (6), aligning the holes in the heater pad and the follower plate. 3. Apply Never Seez to the threads of the three socket head cap screws (not shown), securing the heater pad in place. Tighten screws to 41 Nm (30 ft-lb). Attach the ceramic washers, lock washers and nuts to the heater wire connecting posts (8). 4. Apply Loctite to the lower nuts and let the Loctite cure before attaching the top nut. 5. Connect the wires to the connecting posts (8) and attach the top nuts and washers. Hold the lower nut with a wrench while tightening the top nut to 2.7 + 0.2 Nm (24 + 2 in.-lb). 6. If the thermostat (1) was removed earlier, coat its mating surface with heat conductive paste and secure the thermostat to its heater pad. 7. If the RTD sensor (2) was removed earlier, coat it with heat conductive paste and secure it to its heater pad. 8. Repeat the above steps for each new heater pad. Cover Plate Installation See Figure 1. To install the cover plate, perform the following steps: 1. Remove traces of old joint sealant from the top of the follower plate and from the top surface of the column support flange where they mate with the cover plate (1). 2. Apply fresh joint sealant to the top surface of the follower plate, forming a completely sealed ring where it mates with the cover plate. 3. Apply fresh sealant to the top surface of the column support flange, forming a completely sealed ring where it mates with the cover plate. 4. Apply Never Seez to the threads of the hex head screws, securing the cover plate halves in place. Tighten the hex head screws. NOTE: If the cover plate on the manifold half of the platen was removed, use a screw driver or similar tool to pry the pump manifold up slightly so the cover plate half can be installed. 1998 Nordson Corporation

Platen Heater Pad Replacement 5 3. Parts See Figure 3. Table 1 Platen Heater Pads Replacements, Model 5530 273 793 0.5 in. pins, non-ptfe coated 200/208/380/415 V units 1 273 795 0.5 in. pins, non-ptfe coated 240/480 V units 1 273 797 0.5 in. pins, non-ptfe coated 575 V units 1 115 926 0.5 in. pins, PTFE coated 200/208/380/415 V units 1 115 925 0.5 in. pins, PTFE coated 240/480 V units 1 117 384 0.5 in. pins, PTFE coated 575 V units 1 Table 2 Platen Heater Pads Replacements, Model 5540 273 792 3 in. fins, non-ptfe coated, 200/208/380/415 V units 1 273 794 3 in. fins, non-ptfe coated, 240/480 V units 1 273 798 3 in. fins, non-ptfe coated, 575 V units 1 117 383 3 in. fins, PTFE coated, 200/208/380/415 V units 1 112 781 3 in. fins, PTFE coated, 240/480 V units 1 112 782 3 in. fins, PTFE coated, 575 V units 1 Table 3 Platen Heater Pads Replacements, Model 5506 102 113 Smooth, PTFE coated 200/208/380/415 V units 1 102 114 Smooth, PTFE coated 240/480 V units 1 102 115 Smooth, PTFE coated 575 V units 1 1998 Nordson Corporation

6 Platen Heater Pad Replacement 3. Parts (contd.) Table 4 Platen Seals Replacements, Models 5530/5540/5506 271 576 Seal, rubber (non-ptfe coated) 1 276 977 Seal, PTFE coated 1 4601119 Fig. 3 Heater Pad Original copyright date 1998. Nordson and the Nordson logo are registered trademarks of Nordson Corporation. Loctite is a registered trademark of Loctite Corporation. Never Seez is a registered trademark of Bostik Corporation. 1998 Nordson Corporation