NEW. Quality and efficiency made of experience! Oil- and gas heated boilers for the professionals manifold proven.

Similar documents
AquaMobil. Mobile shower, decontamination and heating systems SWINGTEC

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

Installation & Maintenance Manual

CITY OPEN - CITY BOX from 25 to 35 kw

ENERGY TOP. Condensing boiler solutions

C Tahiti. condensing

Eco Angus Wood Pellet Boilers

Condensing, pre-mixed, wall-hung gas boilers with water tank

Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Heating Systems. An ideal temperature in every pig house

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

INSTALLATION AND OPERATION MANUAL

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

1 - High-velocity gas burners

Since 1983 Nuova COTERM has developed a wide range of water heaters.

RIELLO 40 GS/M SERIES

INSTRUCTION MANUAL FOR OIL BURNER MODELS

We offer ceramic radiant heaters and infra-red radiant tubes.

ST 40 Oil Burner. Installation & Maintenance Manual

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

Washer Extractors TWE 10-15

Seradens Super Seradens Super Plus

MOBILE HOT AIR HEATING SYSTEMS

RHC GAS FIRED HEATING COILS

English. Heating with logs & wood pellets 20-40

PCH/new Series. High performance, total flexibility

Concrete Applications

GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND

Max-3 Steel Shell Boiler

Heat Exchanger Module for Industrial Applications

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

1. GENERAL SAFETY RULES

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

1 VICTRIX ZEUS Superior kw I features

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

REMKO CLK Mobile automatic heater

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Light oil / kerosene burner

ELECTRIC HEATERS. Fireball Electric Heaters. 10,200btu HEAT OUTPUT. heating. 30,706btu HEAT OUTPUT. 9,600btu. sales hotline

ACCUMULATION OF EUROPEAN CLASS

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

"HC" AIRFLO. In-duct firing line burner

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

Light oil - kerosene burner

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R

DH-Direct Fired Poultry Farm Diesel Heater

The iqe Boiler Range. Combination and System T Boilers.

Industrial Applications

The WCGH High Efficiency Commercial Water Heater with Storage Tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

VORTEX BLUE OIL RANGE

VORTEX BLUE OIL RANGE

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

advanced : technology

INSTRUCTION MANUAL FOR OIL BURNER MODELS

10 : 1 Turndown Ratio

Propane Heater REMKO PGM 30 REMKO PGM 60

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

LOW NOx MODULATING GAS BURNERS

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

AHE S -12 VDC AHE S - 24 VDC

GAS AND PELLET BURNERS

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Universal oil burner G

en Direct oil-fired space heaters HD... Operator's manual

4111 Cab Parking Heater Affects: Related:

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

WOLF GAS CONDENSING BOILERS COMFORTLINE

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

SPECIFICATIONS - NIKE

HIGH OUTPUT. Skin design RANGE

MOBILE HOT AIR HEATING SYSTEMS

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Electronic Ignition Water Heater

Light oil burners. One stage operation

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

PRO JET RANGE FOR A PRODUCTIVE, CLEAN & HEALTHY WORK ENVIRONMENT

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

The ultimate in air handling units: directly and indirectly fired

Transcription:

Quality and efficiency made of experience! Oil- and gas heated boilers for the professionals manifold proven. A compact unit with integrated vertical burner. Water under high pressure will be heated quickly to the required temperature, adjusted by the thermostat. Outstanding features: No downtime losses because hot water is available in seconds. No preheat time. There is no need that hot water is transported through the pump: The water is compressed before and will be heated then. The durability of the pump can be extremely extended by that. Reduce investment costs. Reduce assembly costs. The efficiency can be multiplied by parallel connection of several boilers. High efficiency and low consumption of fuel (equal efficiency compared to modern reservoir systems). EC-Type examination manufatured boiler. Easy maintainance. Biodiesel proofed (requires modifications)*. *Notice when biodiesel is used: All fuel leading parts have to be exchanged for those that are tested and proved for biodiesel. The capacity improves by 3-4 % in comparison to normal oil. We could provide a conversion kit for delivered boilers. Application areas: Cleaning techniques: factories, petrol stations, car washs, airports. Hygenic techniques: slaughterhouses, meat manufactories, dairies, breweries, filling factories (water & juice), fast food industry. Cleaning buildings: facades, roofs and floors. Renovation: concrete, marine (shipbuilding industry), large scale plants, tasks for environmental damages and sewer rehabilitation. Supply of process heat in manufacturing i.e. degreasing machines. Tuning set for oil burner A patent protected diffusor, which can be modified subsequently, provides even under difficult conditions a clean and soot free burning. The maintenance intervals of burners that are subject to permanent starts and stops can be postponed enormously. A positive side effect is a higher degree of efficiency up to 3 %. Digital thermostat A digital control is available for a surcharge. The PTC sensor responds much faster than the standard capillary tube sensor in a onestep system if the burner switches off, and activates the system again. This is an advantage if high and constant temperatures are required. NEW Mixing unit Delta oil pump 2 Störk digital thermostate Surcharge MP10400972-2 Safety equipment

Sectioning Pressure flow heater, 110 / 230V, oil- and gas heated, type BR P. Description 1 Chimney 2 Boiler 3 Outer casing 4 Mixing unit 5 Flame tube 6 Inner casing 7 Pressure switch 8 Flow switch 9 Safety valve 10 Water inlet 11 Fastening shackle 12 Insulating plate (oxide ceramics) 13 Oilpump (obsolete for gas operated machine) 14 Fan motor 15 Heating coil 16 Inner lid 17 Outer lid 18 Photocell 19 Exhaust temperature limiter X Y When using the BR1000G the burner, oil specific control and safety devices will be exchanged against gas specific parts Blue arrow fresh air, red arrow exhaust gas t ( C) 100 80 60 40 20 Temperature Effective temperature diagram diagram BR600-BR1000 8 10 12 14 16 18 20 22 24 BR1000 ECO PLUS BR1000 BR900+BR1000G BR750 BR600 26 (l/min) Range of efficiency of the different types: By varying the oil respectively gas pressure and adjustment of the combustion air, the units can be adjusted within the required range of efficiency. By parallel circuits of several units the efficiency can be multiplied. The diagram shows accessible water temperatures operated with 10 bar oil pressure resp. max. gas output. With pleasure we will assist you when calculating the individual requirements. BR600 40-50KW BR750 50-62KW BR900 62-73KW BR1000G+2.0 45-70KW BR1000 65-80KW BR1000 Eco Plus 65-95KW 3

Technical Data Type BR, oil heated, 230V 50Hz / 110V 50-60Hz Description / Type Hc* bar BR600 BR750 BR900 BR1000 Content, heating coil 3/8 300 2,40 Ltr. 2,80 Ltr. 3,45 Ltr. 4,17 Ltr. 3/8 500 2,10 Ltr. 2,56 Ltr. 3,50 Ltr. 4,30 Ltr. 3/8 700-1,14 Ltr. 1,70 Ltr. 1,62 Ltr. 1/2 200 5,23 Ltr. 4,40 Ltr. 6,89 Ltr. 5,75 Ltr. Allowed operating pressure [bar] 3/8 300 300 300 300 3/8 500 500 500 500 3/8-700 700 700 1/2 200 200 200 200 Allowed operating temperature [ C] 95 95 95 95 Dimension l x w x h [mm] * 570x405x535 570x405x625 570x405x710 570x405x810 Weight [kg] * 3/8 300 50,30 58,00 64,00 68,00 3/8 500 53,80 62,50 69,20 74,00 3/8 700 63,60 74,50 85,10 91,60 1/2 200 49,20 56,20 58,50 62,90 Tube length of heating coil [m] 3/8 23 28 36 40 1/2 22 26 28 32 Tube- Ø of heating coil [mm] 3/8 300 17,2 17,2 17,2 17,2 3/8 500 18,0 18,0 18,0 18,0 3/8 700 18,0 18,0 18,0 18,0 1/2 200 21,4 21,4 21,4 21,4 Operating voltage [V/Hz] 230/50 230/50 230/50 230/50 110/50 110/50 110/50 110/50 Total current consumption [Watt] 400 400 400 400 Nozzle [G/h] 1,25 1,5 1,5 or 1,65 1,75 max. oil flow [l/h] 4,35-5,35 5,93-7,26 5,93-8,63 6,92-9,15 Effect. range of capacity [kw] 40-50 50-62 62-73 65-80 Efficiency of combustion [%] >=91 >=91 >=91 >=91 Max. exhaust gas temperature [ c] 230 230 230 210 Flue gas loss [%] <=9 <=9 <=9 <=9 Soot value according to Bacherach 0-1 0-1 0-1 0-1 *Dimensions and weights are without control system and safety device. Total weight for safety device and control: 9,6 kg Dimensions 130 386 100 60 120 300 Ø 11 300 Ø 317 H 3x120 Ø 344 570 A 405 4 B mm A3/8 A1/2 B3/8 B1/2 H BR600 126 132 99 101 535 BR750 126 132 99 101 625 BR900 126 132 99 101 710 BR1000 126 132 99 101 810

Technical Data Type BR1000G, gas heated, 230V 50Hz Description 200 bar 300 bar 500 bar 700 bar Content, heating coil 5,75 Ltr. 4,17 Ltr. 4,30 Ltr. 1,62 Ltr. Nennweite 1/2 3/8 3/8 3/8 Allowed operating temperature [ C] 95 95 95 95 Dimension l x w x h [mm] * 550x550x850 550x550x850 550x550x850 550x550x850 Weight [kg] 71,90 77,00 83,00 100,60 Tube length of heating coil [m] 32 40 40 40 Tube- Ø of heating coil [mm] 21,4 17,2 18,0 18,0 Operating voltage [V/Hz] 230/50 230/50 230/50 230/50 Total current consumption [Watt] 400 400 400 400 Gas pressure [mbar] 20-100 20-100 20-100 20-100 Gas types and consumption at max. power Erdgas H = 6-7 m³/h, Erdgas L = 7-10 m³/h, Propan/Butan (Flüssig) = 2-3 kg/h Effect. Range of capacity [kw] 45-70 45-70 45-70 45-70 Efficiency of combustion [%] >=91 >=91 >=91 >=91 Max. exhaust gas temperature [ c] 210 210 210 210 Flue gas loss [%] <=9 <=9 <=9 <=9 Dimensions BR1000G 59 560 120x60 3x120 825 Ø 344 580 Chimney valve We would like to recommend you a retrofit kit with chimney valve, big fan wheel, a long flame tube and a modified ionization electrode. The item number is MP10400331. NEW 445 Burner unit Dungs gas multi block UV optical flame sensor MP10440001 as surcharge Safety equipment 5

Gross price list, oil heated boiler, 230V 50 Hz, WITHOUT safety system Equipped with: casings of zinc coated sheet steel (AISI 304 available), furthermore the outer casing is powder coated (AISI 304 available), 230 V / 50Hz, ignition transformer, fan motor and solenoid valve, WITHOUT switchbox, WITHOUT control and safety equipment. Boiler type Operating press. [bar] Nom. width Steel heating coil ST Stainless steel heating coil 1.4301 BR600/200 200 1/2 on request on request BR750/200 200 1/2 V1040001101 V1040001107 BR750/300 300 3/8 V1040001102 V1040000503 BR750/500 500 3/8 V1040001117 V10400006 BR750/700 700 3/8 V1040001117-1 BR900/200 200 1/2 V1040001103 V1040001108 BR900/300 300 3/8 V1040000602 V1040000504 BR900/500 500 3/8 V10400037 V1040000601 BR900/700 700 3/8 V10400037-2 BR1000/200 200 1/2 V1040001104 V1040001109 BR1000/300 300 3/8 V1040000509 V1040000506 BR1000/500 500 3/8 V1040000510 V1040000603 BR1000/700 700 3/8 V10400005101 on request Gross price list, oil- and gas heated boiler, 230V 50 Hz, WITH safety system Equipped with: switch box with content according to the circuit diagram, adjustable thermostat, exhaust temperature limiter, flow switch, safety valve, flame control, 3m electric cable. The basic equipment corresponds to the units shown on the previous sides. Additionally the gas boilers are equipped with gas specific safety parts. Boiler Type Operating press. [bar] Nom. width Steel heating coil ST Stainless steel heating coil 1.4301 BR600/200 200 1/2 V1040001403 V1040001409 BR750/200 200 1/2 V1040001405 V1040001410 BR750/300 300 3/8 V10400005102 V1040001112 BR750/500 500 3/8 V1040001401 V1040001118 BR900/200 200 1/2 V1040001407 V1040001411 BR900/300 300 3/8 V1040001110 V1040001113 BR900/500 500 3/8 V1040001404 V1040001119 BR1000/200 200 1/2 V1040001408 V1040001412 BR1000/300 300 3/8 V1040000511 V1040001114 BR1000/500 500 3/8 V10400040 V1040001402 BR1000G/200 200 1/2 V10440010 V10440011 BR1000G/300 300 3/8 V10440002 V10440008 BR1000G/500 500 3/8 V10440003 V10440009 6

Surcharges for specific equipment The following surcharges have to be added to the basic version, shown on table page 6. Description / Type BR600 BR750 BR900 BR1000 BR1000G Inner casing stainless steel 1.4301 M10400030 M10400031 M10400032 M10400033 M10400033-1 Outer casing stainless steel 1.4301 M10400005 M10400006 M10400007 M10400008 M10400008 Diffusor (Tuningset) - B10400320 B10400320 B10400320-110V version (motor, solenoid valve, ignition) M10430002 M10430002 M10430002 M10430002 M10430002 Biodiesel version (oil pre heater) B10400326-1 B10400326-1 B10400326-1 B10400326-1 - Low pressure version (press. switch, valve) MP10400965 MP10400965 MP10400965 MP10400965 MP10400965 Digital thermostat + PTC sensor MP10400972-2 MP10400972-2 MP10400972-2 MP10400972-2 MP10400972-2 Pressure flow heater, gas heated, BR1000G 2.0 Advanced economic gas boiler The new gas burner, made by Theodor Henrichs GmbH can easily be controlled by a digital thermostat and a two- step gas multi block. We achieved a better start up with liquid gas. Our pressure flow heater BR1000G 2.0 is the right choice for you if constant temperatures are needed. Advantages: Heating capacity of approx. 70KW low exhaust gas temperature Exhaust gas emissions are observed despite high efficiency Permanent temperatures by intelligent control improved start up, especially with liquid gas Please contact us for further information. Surcharge M10440001 Dimension BR1000G 2.0 see BR1000G Mixing unit 2 step gas multi block Störk digital thermostat Safety equipment 7

Pressure flow heater, oil heated, DC For mobile usage, independent from alternating voltage net, type BR.12/24 V. The innovative burner technology of Theodor Henrichs GmbH permits an uncomplicated usage of commercial vehicles with 12V or 24V board tension. Version 1 Our base is a 230 V burner with our approved components. This is an entirely DC unit, as the flame control too is available in 12 V and 24 V version. Additional motor for the oilpump is no longer required. The proven Delta pump will be used as a fuel pump. A DC ignition transformer, with high ignition performance, guarantees a safe ignition, even under unfavourable conditions. Warning! You will need a little more space than for the previous version. Upon request we will send you a survey or 3D data. NEU Version 2 We are still able to provide you with the previous version with voltage transformer and an additional pump motor, but we explicitly advice against that. Outstanding features: No downtime losses because hot water is available in seconds. No preheat time. There is no need that hot water is transported through the pump: The water is compressed before and will be heated then. The durability of the pump can be extremely extended by that. Reduce investment costs. Reduce assembly costs. The efficiency can be multiplied by parallel connection of several boilers. High efficiency and low consumption of fuel (equal efficiency compared to modern reservoir systems). EC-Type examination manufatured boiler. Easy maintainance. Biodiesel proofed (requires modifications). Version 2 Version 1 Digital thermostat A digital control is available for 24V for a surcharge. The PTC sensor responds much faster than the standard capillary tube sensor in a one- step system if the burner switches off, and activates the system again. This is an advantage if high and constant temperatures are required. Mixing unit Var. 1: DC fan motor with oil pump coupling 8 Störk digital thermostat Surcharge MP10400972-2 Mounting example

Preconditions: 12/24 V- data system with a sufficient dimensioned generator. (28A with 12V and 14A with 24V. Sufficient fresh water (tank or external filling station) Sufficient storage of heating oil. Application areas: Removal of residues caused by chemical accidents (diesel, oil, grease and other chemicals) Rehabilitation of canals and pipes, disinfection, cleaning of garbage containers, cleaning of facades, concrete rehabilitation. t ( C) 100 80 Temperature Effective temperature diagram diagram BR750-BR1000 The diagram shows achievable water temperatureswith 10 bar oil pressure. With pleasure we will assist you when calculating the individual requirement 60 40 20 8 10 12 14 16 18 20 22 24 26 BR1000 ECO PLUS BR1000 BR900 BR750 (l/min) Attention: Please note our progressive development of the 12 V respectively 24 V burner, where a DC motor is used with direct connection to the oil pump. NEW Sectioning Pressure flow heater, 12/24V, oil heated, type BR Since 2017 P. Description 1 Chimney 2 Boiler 3 Outer casing 4 Mixing unit 5 Flame tube 6 Inner casing 7 Pressure switch 8 Flow switch 9 Safety valve 10 Water inlet 11 Fastening shackle 12 Insulating plate (oxide ceramics) 13 Oilpump (obsolete for gas operated machine) 14 Fan motor 15 Heating coil 16 Inner lid 17 Outer lid 18 Photocell 19 Exhaust temperature limiter Y Blue arrow fresh air, red arrow exhaust gas 9

Technical Data Type BR, oil heated, 12-24V DC Description / Type HZ* Bar BR750 BR900 BR1000 BR1000EcoPlus Content, heating coil 3/8 300 2,80 Ltr. 3,45 Ltr. 4,17 Ltr. 4,17 Ltr. 3/8 500 2,56 Ltr. 3,50 Ltr. 4,30 Ltr. 4,30 Ltr. 3/8 700 1,14 Ltr. 1,70 Ltr. 1,62 Ltr. 1,62 Ltr. 1/2 200 4,40 Ltr. 6,89 Ltr. 5,75 Ltr. 5,75 Ltr. Allowed operating pressure [bar] 3/8 300 300 300 300 3/8 500 500 500 500 3/8 700 700 700 700 1/2 200 200 200 200 Allowed operating temperature [ C] 95 95 95 95 Dimension l x w x h [mm] * 570x460x625 570x460x710 570x460x810 590x460x810 Weight [kg] * 3/8 300 58,00 64,00 68,00 69,00 3/8 500 62,50 69,20 74,00 75,00 3/8 700 74,50 85,10 91,60 92,60 1/2 200 56,20 58,50 62,90 63,90 Tube length of heating coil [m] 3/8 28 36 40 40 1/2 26 28 32 32 Tube- Ø of heating coil [mm] 3/8 300 17,2 17,2 17,2 17,2 3/8 500 18,0 18,0 18,0 18,0 3/8 700 18,0 18,0 18,0 18,0 1/2 200 21,4 21,4 21,4 21,4 Operating voltage [V] 12/24V 12/24V 12/24V 12/24V Total current consumption [Watt] 336 336 336 336 Nozzle [G/h] 1,5 1,5 oder 1,65 1,75 2,25 max. oil flow [l/h] 5,93-7,26 5,93-8,63 6,92-9,15 9,15-12,00 Effect. range of capacity [kw] 50-62 62-73 65-80 90-95 Efficiency of combustion [%] >=91 >=91 >=91 >=91 Max. exhaust gas temperature [ C] 230 230 210 210 Flue gas loss [%] <=9 <=9 <=9 <=9 Soot value according to Bacherach 0-1 0-1 0-1 0-1 *Dimensions and weights are without control system and safety device. Total weight for safety device and control: 9,6 kg Dimensions 130 386 100 60 120 300 Ø 11 300 Ø 317 H 3x120 Ø 344 mm A3/8 A1/2 B3/8 B1/2 H BR750 126 132 99 101 625 570 A 460 B BR900 126 132 99 101 710 BR1000 126 132 99 101 810 EcoPlus 126 132 99 101 810 10

Gross price list, oil heated boiler, 12V or 24V, WITHOUT safety system Equipped with: covers of zinc coated sheet steel AISI 304 available), furthermore the outer case is powder coated (AISI 304 available), 12V ignition transformer, 12V fan motor and 12V solenoid valve, WITHOUT switch box, control and safety equipment. Boiler type Operating press. [bar] Nom. width Steel heating coil ST Stainless steel heating coil 1.4301 BR750/200 200 1/2 V11400016-12o.24V V11400019-12o.24V BR750/300 300 3/8 V11400001-12o.24V V11400010-12o.24V BR750/500 500 3/8 V11400002-12o.24V V11400011-12o.24V BR750/700 700 3/8 V11400003-12o.24V BR900/200 200 1/2 V11400017-12o.24V V11400020-12o.24V BR900/300 300 3/8 V11400004-12o.24V V11400012-12o.24V BR900/500 500 3/8 V11400005-12o.24V V11400013-12o.24V BR900/700 700 3/8 V11400006-12o.24V BR1000/200 200 1/2 V11400018-12o.24V V11400021-12o.24V BR1000/300 300 3/8 V11400007-12o.24V V11400014-12o.24V BR1000/500 500 3/8 V11400008-12o.24V V11400015-12o.24V Gross price list, oil heated boiler, 12V or 24V, WITH safety system Equipped with: 112V ignition transformer, 12V fan motor and 12V solenoid valve, adjustable thermostat, exhaust temperature limiter, flow switch, safety valve, pressure switch, flame control, 3m electric cable. Additional information see above. Boiler type Operating press. [bar] Nom. width Steel heating coil ST Stainless steel heating coil 1.4301 BR750/200 200 1/2 V11400016S-12o.24V V11400019S-12o.24V BR750/300 300 3/8 V11400001S-12o.24V V11400010S-12o.24V BR750/500 500 3/8 V11400002S-12o.24V V11400011S-12o.24V BR900/200 200 1/2 V11400017S-12o.24V V11400020S-12o.24V BR900/300 300 3/8 V11400004S-12o.24V V11400012S-12o.24V BR900/500 500 3/8 V11400005S-12o.24V V11400013S-12o.24V BR1000/200 200 1/2 V11400018S-12o.24V V11400021S-12o.24V BR1000/300 300 3/8 V11400007S-12o.24V V11400014S-12o.24V BR1000/500 500 3/8 V11400008S-12o.24V V11400015S-12o.24V Surcharges for specific equipment The following surcharges have to be added to the basic version. Description / Type BR750 BR900 BR1000 Inner casing stainless steel 1.4301 M10400031 M10400032 M10400033 Outer casing stainless steel 1.4301 M11400001 M11400002 M11400003 Diffusor (Tuningset) B10400320 B10400320 B10400320 Biodiesel version (oil pre-heater) B10400326-1 B10400326-1 B10400326-1 Low pressure version (press. switch, valve) MP10400965 MP10400965 MP10400965 24V Digital thermostat + PTC sensor MP10400972-2 MP10400972-2 MP10400972-2 11

Pressure flow heater, oil heated, BR1000 Eco Plus Innovation The new burner technology of Theodor Henrichs GmbH respects despite high efficiency the legal requirements of BlmSchG. The heating capacity of approx. 90-95 KW can easily be controlled by a digital thermostat and a two-step pump. If constantly high temperatures are need the pressure flow heater BR1000 ECO PLUS is exactly what you need. Advantages: Heating capacity of 90-95 KW low exhaust gas temperatures Exhaust gas emissions are observed despite high efficiency Permanent temperatures by intelligent control Application area: Hygiene: filling automats for water and juices. Renovation: rehabilitation of canal and pipe systems. Availability of renovation: concrete rehabilitation. Please contact us for further information, the technical data will be printed on the following page. t ( C) 100 80 60 Temperature Effective temperature diagram diagram BR1000 ECO PLUS BR1000 ECO PLUS Range of capacity of the different types: Within the indicated range of capacity the machines can be adjusted to the required capacity by varying the oil or gas pressure respectively and by adjusting the combustion air. Parallel connection of several machines, multiply the capacity. 40 20 8 10 12 14 16 18 20 22 24 BR1000 BR900+BR1000G BR750 BR600 26 (l/min) The diagram shows the achievable water temperatures with an oil pressure of 13 bar. With pleasure we will assist you when calculating your individual requirements. Mixing unit Suntec 2 step pump Störk digital thermostat Safety equipment 12

Technical Data Type BR1000 Eco Plus, oil heated, 230V 50Hz, 12V and 24V Description 200 bar 300 bar 500 bar 700 bar Content, heating coil 7,60 Ltr. 4,17 Ltr. 3,66 Ltr. 1,62 Ltr. Nominal width heating coil 1/2 3/8 3/8 3/8 Allowed operating temperature [ C] 95 95 95 95 Dimension l x w x h [mm] 590x405x850 590x405x850 590x405x850 590x405x850 Weight [kg] 63,90 69,00 75,00 92,60 Tube lenght of heating coil [m] 32 40 40 40 Tube Ø of the heating coil [mm] 21,4 17,2 18,0 18,0 Operating voltage/ Frequency [V/Hz] 230/50 230/50 230/50 230/50 12 and 24 12 and 24 12 and 24 12 and 24 Total current consumption [Watt] 440 440 440 440 Oil pressure [bar] 7-14 7-14 7-14 7-14 Nozzle [G/h] 2,25 2,25 2,25 2,25 max. fuel consumption [l/h] 9,15-12 9,15-12 9,15-12 9,15-12 Heating capacity [kw] 90-95 90-95 90-95 90-95 Efficiency of combustion [%] >=91 >=91 >=91 >=91 Max. exhaust gas temperature [ C] 230 230 230 230 Exhaust gas loss [%] <=9 <=9 <=9 <=9 Dimensions BR1000 Eco Plus The difference to our standard boiler BR1000 is the bigger fan wheel housung Gross price list, oil heated boiler BR1000 Eco Plus, 230V 50 Hz, WITH safety control Equipped with: switch box with content according to circuit diagram, digital thermostat, PTC-sensor, 2-step-pump, temperature limiter, flow switch, safety valve, flame control, diffusor long, inner coat of stainless steel, 3m electric cable, big fan housing & fan wheel. The basic equipment corresponds to the units of page 4. (Surcharge M10440001-2) Boiler type Operation pressure [bar] Nomin. width Steel heating coil ST Stainless steel heating coil 1.4301 BR1000EcoPlus/200 200 1/2 V1040001408-ECO V1040001412-ECO BR1000EcoPlus/300 300 3/8 V1040000511-ECO V1040001114-ECO BR1000EcoPlus/500 500 3/8 V10400040-ECO On request 13