Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Similar documents
KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

Koja Oy. manufactures ventilation units Fair 80 ec

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

TECHNICAL SPECIFICATION

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

TECHNICAL SPECIFICATION

VALLOX VENTILATION PRICELIST 2018

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Manual. Document ENG

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

R E P O R T D I N E N

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

nzeb office building

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Confirmation of Product Type Approval

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

INTERNATIONAL STANDARD

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST

This document is a preview generated by EVS

FLUE GAS TEMPERATURES OF FIREPLACES

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

GreenMaster HP Exhaust air heat pump for residential properties

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

GASTEC QA. Approval Requirements 69-1

Solar thermal solutions within the Energy Labelling Context

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Referens projects. Powerpoint Templates

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Ecodesign in SystemairCAD

Refrigerant Dryers Refrigerant Compressed Air Dryer with integrated DF Filters

STR-600 Impact Dryer

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Smoke extract fan SMHA HATCH

Heat Exchanger Earny Type

DAIKIN Air Handling Unit Modular

Installation instruction

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Importance of a Draught Regulator

SVENSK STANDARD SS-EN :2005

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

This document is a preview generated by EVS

INTERNATIONAL STANDARD

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

AIR HANDLING UNITS MANDÍK

This document is a preview generated by EVS

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

SVENSK STANDARD SS-EN :2004

GASTEC QA. Approval Requirements 136

SPECIFICATIONS FOR THE NF ELECTRICITE PEFORMANCE MARK N LCIE / C AUTONOMOUS STORAGE WATER HEATER WITH ELECTRICALLY DRIVEN COMPRESSOR

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

This document is a preview generated by EVS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

GLEB Kitchen exhaust fan

ABLOY SENTRY. Security for extreme environments

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment.

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

GASTEC QA. Approval Requirements 31-2

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

COTES ALL-ROUND THE C30 RANGE

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

Green economy with natural refrigerants

GASTEC QA. Approval Requirements 31-1

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

2013 innovation. Room-by-room demand controlled heat recovery ventilation

HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS. Reduce costs for compressed air generation

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Installation instruction

Installation instruction

GASTEC QA. Approval Requirements 6

INTERNATIONAL STANDARD

KOMFORT EC DB Suspended heat recovery air handling units

Technical Data Inventus upright refrigerators and freezers C & F. Rev

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Esmi Sense FDP Fire detection panel with ALC2 loop controller

VERSO Air Handling Units

Heat pump and energy recovery systems

PFS Single stage axial fan The axial fan for modern boiler plants

Seasonal Performance and Exergy Analysis of Multi-Function Heat Pump Units

Transcription:

Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox Oy manufactures ventilation units Vallox TSK Multi 80 MC Certificate No VTT-C-11032-14 Translation 1 (2) Vallox TSK Multi 80 MC is intended to be used as a ventilation unit of a dwelling. Efficiency of heat recovery and specific electrical power and thermal, aerodynamic and acoustic characteristics have been defined according to the certification criteria VTT SERT R018-04: Ventilation unit of a dwelling. A summary of the calculated energy efficiency of the ventilation unit in the weather conditions of Southern Finland is presented in the following: ANNUAL EFFICIENCY OF HEAT RECOVERY, a Annual efficiency of heat recovery is 75 % when average exhaust air flow is Annual efficiency of heat HIGH EFFICIENCY OF HEAT RECOVERY recovery, a, % A++ A+ A B C D E F G LOW EFFICIENCY OF HEAT RECOVERY Annual efficiency of heat recovery, % (Building code = 45) 80 78 76 74 72 over 80 75-80 70-75 60-70 50-60 40-50 30-40 1-30 70 0 10 20 30 40 50 60 70 80 Exhaust air flow, dm³/s A+ 0 SPECIFIC ELECTRICAL POWER, P esu Specific electrical power is when average exhaust air flow is Specific electrical power, P esu, HIGH POWER EFFICIENCY kw/(m³/s) A++ A+ A B C D E F G LOW POWER EFFICIENCY Specific electrical power, kw/(m³/s) (Building code = 2.0) 2.5 2.0 1.5 1.0 0.5 below 0.6 0.6-0.8 0.8-1.0 1.0-1.5 1.5-2.0 2.0-2.5 2.5-3.0 3.0-3.5 over 3.5 0.0 0 10 20 30 40 50 60 70 80 Exhaust air flow, dm³/s A The ventilation unit meets the requirements presented on page number 2. The properties of the ventilation unit, and the source information and the results of the energy efficiency calculation, are presented in an appendix to the certificate. This certificate is valid until April 1, 2019 on condition that the product is not essentially changed and that the manufacturer has a valid quality assurance agreement and contract on certification with VTT Expert Service Ltd. The validity of the certificate can be checked with VTT Expert Service Ltd or on the Internet at http://www.vttexpertservices.fi/certifications/. Other conditions are presented at the end of the certificate. Espoo, April 2, 2014 Liisa Rautiainen Lead Auditor Mikko Saari Auditor VTT EXPERT SERVICES LTD P.O. Box 1001, FI-02044 VTT, Finland Tel. +358 020 722 111, Fax +358 020 722 7003

The certified ventilation unit of a dwelling meets the requirements presented below. Certificate No VTT-C-11032-14 Translation 2 (2) Property Determination method Requirement Result Leakage EN 13141-7 Annex B Building code, part D2 Meets the requirement Air filter by-pass leakage EN 1886 EN 1886, Building code, part D2 Meets the requirement Aerodynamic performance (pressure / air flow) Acoustic performance ISO 3741, ISO 5135, EN 13141-7 EN 308, EN 13141-7 - The measured values correspond to the values declared by the manufacturer - The measured values correspond to the values declared by the manufacturer Temperature ratio EN 308 55 % Meets the requirement Operation at low outdoor air temperatures EN 308, EN 13141-7 VTT SERT R018-04 Meets the requirement Specific electrical power EN 308, EN 13141-7 Building code, part D3 Meets the requirement Annual efficiency of the heat recovery of exhaust air Handout 122/2003 from the Ministry of the Environment Building code, part D3 Meets the requirement Requirements: - Leakage: Leakage class A of the casing, leakage air flow rate between the supply and exhaust air sides at most 6 % of the nominal air flow rate of the air supply unit at a test pressure of 300 Pa (building code, part D2, guideline 3.7.1.3). - Air filter by-pass leakage: Accepted by-pass leakage is 2 % of the declared maximum air flow. The test pressure is double the pressure drop of the clean air filter at the declared maximum air flow. - Operation at low outdoor air temperatures: The freezing protection and the removal of water condensing from exhaust air have been implemented reliably. - Specific electrical power: At most 2.0 W/(dm³/s) (building code, part D3, guideline 2.6.1.1). - Annual efficiency of the heat recovery of exhaust air: At least 45 % (building code, part D3, provision 2.5.11). Conditions of the validity of the certificate: Where reference is made in this certificate to any regulations, publications, standards or other documents, it shall be construed as a reference to such publication in the form of which it is in force at the date of this certificate. The manufacturer is responsible for the quality and continuous quality control of the product. In granting this certificate, VTT Expert Services Ltd does not accept responsibility to any person or body for any loss or damage incurred in respect of personal injury arising as direct or indirect result of the use of this product. The use of the name of VTT Expert Services Ltd or the name VTT Technical Research Centre of Finland in any other form in advertising or distribution in part of this certificate is only permissible with written authorisation from VTT Expert Services Ltd.

Translation 1 (5) Product information and calculation of energy efficiency for the ventilation unit of a dwelling Product information: Model: Vallox TSK Multi 80 MC Manufacturer and representative of the device: Vallox Oy, Myllykyläntie 9-11, FI-32200 Loimaa, Finland. tel. +358 10 7732 200, www.vallox.com Outer dimensions: 1026 mm (width) x 293 mm (height) x 626 mm (depth) Weight: 59 kg Air duct connections: two connections on opposite sides of the unit (in use), four connections on the back (not in use), diameter of the duct 125 mm Electrical connection: 230 V, 10 A, fixed AC-connector Fans: direct current fans, 2 x 71 W, Ebmpapst R3G 190-AB07-02 Control of air flows: 4 step control, each control setting can be chosen freely within the predefined operating range. Control voltages 3 11.4 V. Air filters: outdoor air G4, supply air F7 and exhaust air G4 Heat recovery (HR): counter-cross-flow plate heat exchanger Method of preventing freezing of the HR: demand controlled defrosting based on the temperature measurements. The defrosting is carried out by bypassing the HR on the supply air side. Heating radiators: after-heating of supply air: electrical resistance of 1.8 kw (2 x 0.9 kw)

Translation 2 (5) Ventilation unit Vallox TSK Multi 80 MC Southern Finland Climate Helsinki test year TRY 2012 Dimensioning temperature of outdoor air -26 C Average temperature of outdoor air (heating period) 1.0 C Heating energy demand of ventilation without heat recovery 5 597 kwh/a 100 % Heating energy demand of ventilation with heat recovery 1 389 kwh/a 25 % Thermal energy recovered from exhaust air 4 208 kwh/a 75 % 68 kwh/a Annual efficiency of the heat recovery of exhaust air, a 75% Coefficient of performance 1 kwh of electricity produces 14.4 kwh heating energy

Translation 3 (5) Ventilation unit Vallox TSK Multi 80 MC Central Finland Climate Jyväskylä test year TYR 2012 Dimensioning temperature of outdoor air -32 C Average temperature of outdoor air (heating period) -0.1 C Heating energy demand of ventilation without heat recovery 6 544 kwh/a 100 % Heating energy demand of ventilation with heat recovery 1 676 kwh/a 26 % Thermal energy recovered from exhaust air 4 868 kwh/a 74 % 130 kwh/a Annual efficiency of the heat recovery of exhaust air, a 74% Coefficient of performance 1 kwh of electricity produces 16.7 kwh heating energy

Translation 4 (5) Ventilation unit Vallox TSK Multi 80 MC Northern Finland Climate Sodankylä test year TRY 2012 Dimensioning temperature of outdoor air -38 C Average temperature of outdoor air (heating period) -2.6 C Heating energy demand of ventilation without heat recovery 7 946 kwh/a 100 % Heating energy demand of ventilation with heat recovery 2 333 kwh/a 29 % Thermal energy recovered from exhaust air 5 612 kwh/a 71 % 446 kwh/a Annual efficiency of the heat recovery of exhaust air, a 71% Coefficient of performance 1 kwh of electricity produces 19.2 kwh heating energy

Translation 5 (5) Ventilation unit Vallox TSK Multi 80 MC Southern Germany Climate Munich [IWEC- WMO#108660 ASHRAE 2001] Dimensioning temperature of outdoor air -16 C Average temperature of outdoor air (heating period) 2.1 C Heating energy demand of ventilation without heat recovery 4 631 kwh/a 100 % Heating energy demand of ventilation with heat recovery 1 088 kwh/a 23 % Thermal energy recovered from exhaust air 3 543 kwh/a 77 % 9 kwh/a Annual efficiency of the heat recovery of exhaust air, a 77% Coefficient of performance 1 kwh of electricity produces 12.1 kwh heating energy