RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Similar documents
CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

geothermal march 2011

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

R557R EN January 2012

Mercury Mixing Kit (Code: ME1053)

Metering systems 0548EN April 2014

caleffi hydronic valves page 1 of 12

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

Dynamic thermostatic radiator valves DYNAMICAL

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Technical Product Guide

Systems for central heating

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Composite under-boiler dirt separator with magnet DIRTMAG

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

Thermotech underfloor heating

Zurn Hydronics Prices Effective 1/01/06

A/23 MFFI - A/27 MFFI

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Herz York Direct Heat Interface Unit

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VAILLANT SPARE PART CATALOGUE

Thermostatic Radiator Valves (Caleffi)

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

FHM-Cx Mixing Shunts for Floor Heating

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076

DISCALDIRT deaerator-dirt separator

Installation and operation manual for mixing modules FH-MJB and FH-MJC

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

FHM-Cx Mixing Shunts for Floor Heating

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

Flush individual room control for floor heating systems

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Section - A. Radiator Valves

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

PARTS BOOK. From S/N:

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Solar heating systems

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Pivot Stove Hydronic Installation Guide

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Radiator Valve Program

Thermostatic mixing valves with interchangeable cartridges

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Thermostatic mixing valves with replaceable cartridge for centralized systems

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Enzo Concealed Shower Mixing Valve

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Roth fixed-value control set with high-efficiency pump

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

DIRECT AND INDIRECT THERMAL ENERGY METERING

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Grant Energy Management Control Systems. Includes weather compensation, sequence controllers, low loss headers and zone pumps

GALATEA DOMUS. Dal 1901 COD

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

Power X High Power Condensing Wall-Hung Boilers

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Power X High Power Condensing Wall-Hung Boilers

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

ECO1ZN3P, ECO2ZN4P ECO

Control valves for floor heating systems. Floor Heating Manifolds

The New Caroma TMV20

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

Transcription:

RADIANT PANEL CONTROL QUICK GUIDE 05

RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the heat exchanger terminals at a constant temperature. This approach uses ON/OFF valves or flow modulating valves, with the pump always upstream of the valve. Flow temperature control of the medium feeding the terminals at constant flow rate. This approach employs modulating mixing valves to control the temperature and the pump is always downstream of the valve. Panel system temperature regulator units control the temperature of the medium supplied to the panels according to method (). The flow temperature to the panels is generally different from that of the boiler or chiller unit, so that there must be a mixing unit upstream of the circulation pump for the panels circuit. We give below a number of definitions used in the temperature regulation by means of regulation units. Definition Description Reference drawing or diagram Type of regulation Outside compensated temperature regulation The flow temperature supplied to the system varies depending on the outside temperature changes according to a regulation curve. T ( C) OUTSIDE T ( C) Modulating temperature regulation with compensated set point The flow temperature supplied to the system varies depending on the return temperature changes from the system. This latter temperature is the characteristic parameter of the actual instantaneous thermal load. T; T ( C) DESIGN THERMAL LOAD % Set point regulation The flow temperature supplied to the system is constant at an adjustable value. T ( C) OUTSIDET ( C)

Definition Description Reference drawing or diagram Type of regulator Digital regulator Electronic device which processes the temperature signals, using a microprocessor and software, and sends control signals to the regulation valve actuators. Thermostatic regulator Mechanical device working by means of a thermostatic element expansion or contraction in contact with the fluid being controlled. STROKE (mm) TEMPERATURE ( C) Type of valve / -way / mixing Simultaneous control of the primary circuit medium and the system return medium. They are mixed directly inside the valve. -way / mixing Simultaneous control of the primary circuit medium and the system return medium. They are mixed directly inside the valve, so as to enable double circulation on both the primary and secondary circuit. Type of actuator Three point (or position) electrical actuator Electrically supplied actuator with common contact, opening contact and closing contact. The contacts are supplied directly by the regulator, which is also a three-point type. M N L 0 V Built-in thermostatic control Mechanical device controlled by a built-in sensor containing the thermostatic element which expands or contracts.

DIRECT SUPPLY UNIT FOR CENTRAL HEATING Complete with adjustable differential by-pass Complete with temperature gauges and pressure gauges High efficiency pump Can be coupled to SEPCOLL separator-manifold 65 series Code: 656... 6560WYP 65650WYP Technical Brochure: 07 055 Version with upward flow - flow on RH side Version with upward flow - flow on LH side Version with reversible flow High-efficiency pump ALPHA L 5-60 65600AL High-efficiency pump UPML 5-95 6560UPM Pump YONOS PARA 5/6 Structural component (spacer) Flow temperature gauge Return temperature gauge 5 Secondary circuit shut-off valves 6 Connecting pipe (with check valve) 7 Operating spanner for shut-off valves on secondary circuit 8 Insulation for heating and cooling 9 Differential by-pass valve opt. opt. opt.

THERMOSTATIC TEMPERATURE REGULATING UNIT FOR CENTRAL HEATING SET POINT THERMOSTATIC REGULATING UNIT Adjustable constant flow temperature -way mechanical thermostatic regulation with built-in sensor Complete with adjustable differential by-pass High efficiency pump Can be coupled to SEPCOLL separator-manifold 66 series Code: 666... Technical Brochure: 08 Version with reversible flow High-efficiency pump ALPHA L 5-60 Temperature adjustment range 5 50 C 66600AL Temperature adjustment range 0 70 C 66605AL High-efficiency pump UPML 5-95 Temperature adjustment range 5 50 C 6660UPM -way thermostatic valve with built-in temperature sensor Insulation Operating spanner for shut-off valves on secondary circuit 5 Flow temperature gauge 6 Return temperature gauge 7 Secondary circuit shut-off valves 8 Connection pipe (with check valve) 9 Safety thermostat kit opt. 0 Differential by-pass valve opt.

MOTORISED TEMPERATURE REGULATING UNIT FOR CENTRAL HEATING COMBINABLE WITH OUTSIDE COMPENSATED AND COMPENSATED SET POINT TEMPERATURE REGULATORS Regulation with -way motorised valve Complete with adjustable differential by-pass High efficiency pump Can be coupled to SEPCOLL separator-manifold 67 series Code: 676... 676... 6760WYP 67650WYP Technical Brochure: 09 05 Version with upward flow - flow on RH side Version with upward flow - flow on LH side Mixing valve with three-point actuator Flow temperature gauge Return temperature gauge Outside temperature probe 5 High-efficiency pump ALPHA L 5-60 67600AL 6760AL High-efficiency pump UPML 5-95 6760UPM 676UPM Pump YONOS PARA 5/6 6 Insulation for heating and cooling 7 Primary circuit shut-off valves 8 Connecting pipe (with check valve) 9 Operating spanner for shut-off valves on secondary circuit 0 Differential by-pass valve opt. opt. opt. opt.

ACCESSORIES FOR TEMPERATURE REGULATING UNITS 65-66 - 67 SERIES 66 series Code: 6600 66005 Technical Brochure: 08 Thermostatic mixing valve. 5 50 C 0 70 C 67 series Code: 670 670 Technical Brochure: 09 Three-way valve with sector obturator and three point actuator. RH LH 65 series Code: 6500 Mounting bracket in stainless steel. 59 series Code: 59006 Differential by-pass valve, setting range 0, m w.g.. Technical Brochure: 07 65 series Code: 65006 Pair of eccentric tailpieces. Technical Brochure: 07 65 series Code: 6500 65007 Technical Brochure: 07 Safety thermostat kit. 55 C ± 0 C ± 65 series Code: 6500 Sensor holder extension. Technical Brochure: 07 65 series Code: 6500 Female union with captive nut, complete with gasket. Technical Brochure: 07 65 series Code: 6500 Hydraulic separator kit. Technical Brochure: 07 6 series Code: 6000 Digital temperature regulator for heating and cooling. Complete with flow/return probes and contact probe holder. Technical Brochure: 0 50 series Code: 500 500 500 Outside compensated digital temperature regulator. channel channels channels Complete with contact flow probe and outside probe. 50 series Code: 50 Outside compensated digital temperature regulator for heating and cooling. Complete with flow probe, outside probe and limit relative humidity probe.

MODULATING TEMPERATURE REGULATING UNIT IN INSPECTION WALL BOX COMPENSATED SET POINT REGULATION WITH PROBE Variable flow temperature depending on the system return temperature Digital regulation with -way motorised valve, for heating and cooling control Kit for primary circuit with manifolds with built-in valves and differential by-pass Box with adjustable height/depth brackets Flow manifold equipped with flow meters and balancing valves. Return manifold equipped with shut-off valves. End fittings with multi-position ball valves, automatic air vent, differential pressure control by-pass kit and fill/drain hose connection. CALEFFI Code completion in relation to outlet number C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H= 8 outlets I = 9 outlets L = 0 outlets M = outlets N = outlets O = outlets 7 series Code: 75.. 75.. 75.. 00 75.. 00 Technical Brochure: 05 05 05 05 Digital temperature regulator for heating and cooling Three-way mixing valve Three-point actuator High efficiency pump ALPHA L 5-60 75.AL 75.AL 75.AL 00 75.AL 00 5 Flow temperature probe 6 Return temperature probe 7 Adjustable drain cock 8 Safety thermostat 9 Flow and return temperature gauges with pockets 0 Pressure gauge Primary circuit shut-off valves Distribution manifolds with built-in valves for primary circuit Differential by-pass kit for primary circuit Relative humidity limit control probe 5 Relative humidity control components

SET POINT THERMOSTATIC TEMPERATURE REGULATING UNIT IN INSPECTION WALL BOX SET POINT THERMOSTATIC REGULATING UNIT Adjustable constant flow temperature -way mechanical thermostatic regulation with built-in sensor Panel distribution manifolds with differential by-pass Kit for primary circuit with manifolds with built-in valves and differential by-pass Box with adjustable height/depth brackets Flow manifold equipped with flow meters and balancing valves. Return manifold equipped with shut-off valves. End fittings with multi-position ball valves, automatic air vent, differential pressure control by-pass kit and fill/drain hose connection. Code completion in relation to outlet number C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H= 8 outlets I = 9 outlets L = 0 outlets M= outlets N= outlets O= outlets 7 series Code: 75.. 75.. 00 Technical Brochure: 055 056 -way thermostatic mixing valve with built-in sensor High-efficiency pump ALPHA L 5-60 75.AL 75.AL Adjustable drain cock Safety thermostat 5 Flow and return temperature gauges with pockets 6 Pressure gauge 7 Primary circuit shut-off valves 8 Distribution manifolds with built-in valves for primary circuit 9 Differential by-pass kit for primary circuit 0 Electrical wiring box

SET POINT THERMOSTATIC TEMPERATURE REGULATING UNIT SET POINT THERMOSTATIC REGULATING UNIT Adjustable constant flow temperature -way mechanical thermostatic regulation with built-in sensor Panel distribution manifolds in composite material with built-in flow meters and shut-off valves with differential by-pass Kit for primary circuit with manifolds with built-in valves and differential by-pass Return manifold equipped with shut-off valves. Flow manifold equipped with flow meters and balancing valves. Flexible kit for differential by-pass setting (optional, code 8000) End fittings with automatic air vent and fill/drain cock. Code completion in relation to outlet number C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H= 8 outlets I = 9 outlets L = 0 outlets M= outlets N= outlets O= outlets 8 series Code: 85.5 85. 86. 5 00 86. 00 Technical Brochure: 090 09 -way thermostatic mixing valve with built-in sensor High efficiency pump ALPHA L 5-60 85.5AL 85. AL 86.5AL 00 86.AL 00 Fitted for adjustable drain cock Safety thermostat 5 Pressure gauge 6 Distribution manifolds with built-in valves for primary circuit 7 Differential by-pass kit for primary circuit 8 Electrical wiring box Box with adjustable height/depth brackets

50 0 0 0 0 50 0 0 0 0 COMPOSITE MATERIAL MANIFOLDS MEDIUM DISTRIBUTION AND CONTROL WITH SPECIFIC COMPONENTS Specific selected material Flow rate regulation and direct measurement with flow meter for each circuit Automatic shut-off for each circuit Thermal emission control for each panel Quick pipe connection with coupling adapter with clip Installation of thermo-electric actuator 9 C 6 CAMERA C. MATRIM. PRANZO ENTRATA CUCINA BAGNO Flow rate regulation with flow meter 8 5 C 7 0 6 C CAMERA C. MATRIM. PRANZO ENTRATA CUCINA BAGNO Code completion in relation to outlet number C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H= 8 outlets I = 9 outlets L = 0 outlets M = outlets N = outlets O = outlets P = outlets 670-67 series Code: 6706. 676. Technical Brochure: 06 Flow manifold with built-in flow meters and flow rate balancing valves Return manifold with built-in shut-off valves suitable for thermo-electric actuator Flow end fitting complete with automatic air vent and fill/drain valve Flow end fitting complete with automatic air vent and fill/drain valve 5 LCD digital temperature gauges 6 Ball shut-off valves 7 Brackets for box or wall mounting 8 Coupling adapter for panel pipe connection 9 Low depth box with adjustable height/depth brackets 0 Code 675900, push-fit temperature gauge for panel pipe opt. opt. 680 series, fitting for plastic or multi-layer panel pipe opt. opt. 656 and 656 series, thermo-electric actuators opt. opt.

BRASS DISTRIBUTION MANIFOLDS MEDIUM DISTRIBUTION AND CONTROL WITH SPECIFIC COMPONENTS Flow rate regulation and direct measurement with flow meter for each circuit Automatic shut-off for each circuit End fittings with automatic air vent and drain cock Thermal emission control for each panel Polymer mounting brackets with adjustable centre distance for 659 series boxes or for direct wall mounting 5 0 8 9 Code completion in relation to outlet number B= outlets C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H = 8 outlets I = 9 outlets L = 0 outlets M = outlets N = outlets O = outlets 66 series Code: 666. Technical Brochure: 060 Flow manifold with flow meters and built-in flow rate balancing valves Return manifold with built-in shut-off valves fitted for thermo-electric actuator End fittings complete with manual and automatic air vents, double radial end fitting and drain cocks with plugs Pair of mounting brackets for box or wall installation 5 Upper and lower manifold supports for brackets; may be assembled using the quick push-fit system 6 Ball shut-off valves 7 Brackets for box or wall mounting 8 680 series, fitting for plastic or multi-layer panel pipe opt. 9 86 series, screw plug with nut for manifold outlets opt. 0 656 and 656 series, thermo-electric actuators opt. 659 and 66 series, box opt.

BRASS DISTRIBUTION MANIFOLDS MEDIUM DISTRIBUTION AND CONTROL WITH SPECIFIC COMPONENTS Flow rate regulation with micrometric regulator to each circuit Automatic shut-off for each circuit End fittings with automatic air vent and drain cock Thermal emission control for each panel Polymer mounting brackets with adjustable centre distance for 659 series boxes or for direct wall mounting 5 0 8 9 Code completion in relation to outlet number B= outlets C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H= 8 outlets I = 9 outlets L = 0 outlets M = outlets N = outlets O = outlets 66 series Code: 666.6 Technical Brochure: - Flow manifold with micrometric valves for flow rate pre-regulation Return manifold with built-in shut-off valves fitted for thermo-electric actuator End fittings complete with manual and automatic air vents, double radial end fitting and drain cocks with plugs Pair of mounting brackets for box or wall installation 5 Upper and lower manifold supports for brackets; may be assembled using the quick push-fit system 6 Ball shut-off valves 7 Brackets for box or wall mounting 8 680 series, fitting for plastic or multi-layer panel pipe opt. 9 86 series, screw plug with nut for manifold outlets opt. 0 656 and 656 series, thermo-electric actuators opt. 659 and 66 series, box opt.

CALEFFI CAMERA CALEFFI CAMERA CALEFFI CAMERA CALEFFI CAMERA HOBBY HOBBY SOGGIORNO SOGGIORNO ϒC 50 50 0 0 0 0 0 0 0 0 WC WC BRASS DISTRIBUTION MANIFOLDS MEDIUM DISTRIBUTION AND CONTROL WITH SPECIFIC COMPONENTS Flow rate regulation and direct measurement with flow meter for each circuit Automatic shut-off for each circuit Differential pressure control Simple filling and commissioning with multi-position valves Thermal emission control for each panel Flow rate regulation with flow meter 9 8 7 6 0 5 Position for by-pass mode CALEFFI Installation of thermoelectric actuator Fill/drain position CALEFFI Code completion in relation to outlet number C= outlets D= outlets E=5 outlets F = 6 outlets G= 7 outlets H= 8 outlets I = 9 outlets L = 0 outlets M = outlets N = outlets O = outlets P = outlets 668...S series Code: 668...S Technical Brochure: 0 Flow manifold with flow meters and built-in flow rate balancing valves Return manifold with built-in shut-off valves fitted for thermo-electric actuator Flow end fitting complete with two-position ball valve, automatic air vent and fill/drain hose connection Return end fitting complete with three-position ball valve, by-pass connection and fill/drain hose connection 5 Off-centre differential by-pass kit complete with pipe for manifold connection 6 Ball shut-off valves 7 Brackets for box or wall mounting 8 6..S series, F x / M reduction opt. 9 86 series, screw plug with nut for manifold outlets opt. 0 Code 675900, push-fit temperature gauge for panel pipe opt. 680 series, fitting for plastic or multi-layer panel pipe opt. 7S series, compression fitting for annealed copper, hard copper, brass, mild steel and stainless steel pipes opt. 656 and 656 series, thermo-electric actuators opt. 659 and 66 series, box opt.

Code completion in relation to outlet number MANIFOLDS AND ACCESSORIES C= outlets D= outlets E=5 outlets F = 6 outlets G = 7 outlets H= 8 outlets 666...S - 667...S series Code: 6667. 5S 6677. 5S Technical Brochure: 0 Flow manifold with built-in flow meters and flow balancing valves Return manifold complete with shut-off valves fitted for thermo-electric actuator. 5996 series Code: 59967 599675 Application: 666...S - 667...S - 668...S. Technical Brochure: 0 End fitting composed of: double radial connection with two-position ball valve, automatic air vent and fill/drain hose connection. End fitting composed of: double radial connection with three-position ball valve, by-pass connection with cap and fill/drain hose connection. 500 series Code: 500 Application: 666...S - 667...S - 668...S Technical Brochure: 0 Automatic air vent with hygroscopic cap Code completion according to size 6 = Connection x / 7 = Connection / x / 9...S series Code: 90. 7S 9. 7S Application: 666...S - 667...S - 668...S Technical Brochure: 0 Pair of ball shut-off valves Pair of ball shut-off valves complete with temperature gauges Ø 0 mm with 0 80 C scale 658 series Code: 65800 Application: 666...S - 667...S - 668...S Technical Brochure: 00 Pair of mounting brackets for use with 659 and 66 series boxes, or for direct wall mounting 668...S series Code: 668000S Application: 666...S - 667...S - 668...S Technical Brochure: 0 Differential by-pass eccentric kit complete with pipe for connection to manifolds

ACCESSORIES 7...S series Code: 7...S Application: 666...S - 667...S - 668...S. Technical Brochure: 0 Compression fitting for annealed copper, hard copper, brass, mild steel and stainless steel pipes. O-Ring seal. 680 series Code: 6805.. Application: 666...S - 667...S - 668...S - 7-7 - 8-670 - 67. Technical Brochure: 0 Self-adjustable diameter fitting for single and multilayer plastic pipes. Code completion according to voltage = 0 V = V 656. series Series: 656 656 656 656 Application: 666...S - 668...S - 667...S - 7-7 - 8-670 - 67. Thermo-electric actuator. NC. 6560. Thermo-electric actuator. NC. Equipped with auxiliary microswitch. 656. Technical Brochure: 00 098 0 098 Thermo-electric actuator. With opening position indicator. Quick-coupling installation with clip adaptor. NC. Low power consumption 6560. 6560. Thermo-electric actuator. With opening position indicator. Low power Quick-coupling installation with clip adaptor. NC. consumption Equipped with auxiliary microswitch. 656. 656. Thermo-electric actuator with manual handle and position indicator. NC. 6560. Thermo-electric actuator with manual handle and position indicator. NC. Equipped with auxiliary microswitch. 656. 605 series Code: 605 6058 Application: 666...S - 667...S - 668...S - 7-7 - 8-670 - 67. Technical Brochure: 086 Control bar with channels 8 channels. 675 series Code: 675900 Application: 666...S - 667...S - 668...S - 7-7 - 8-670 - 67. Technical Brochure: 06 Push-fit temperature gauge for panel pipe from 5 to 8 mm, 5 50 C temperature scale. 8 series Code: 8000 Application: 8-670 - 67. Fixed setting differential by-pass kit 5 kpa (,500 mm w.g.) complete with hose.

ACCESSORIES 9 series Code: 9066 Application: 66-66. Pair of ball shut-off valves with O-Ring seal. 9 series Code: 6600 Application: 66-66. Off-centre fixed setting by-pass kit 5 kpa (.500 mm w.g.). BOXES FOR 67 SERIES MANIFOLDS 675 series Code: 675060 675080 Low depth box with adjustable height/depth brackets (h= 550; d = 80 0) (b = 600) (b = 800) 659 series Code: 65905 659065 659085 65905 Technical Brochure: 080 Box (h= 500; p = 80 0) (b = 00) (b = 600) (b = 800) (b = 000) BOXES FOR 67 AND 668...S SERIES MANIFOLDS 659 series Code: 6590 65906 65908 6590 659 Technical Brochure: 0 Box (h= 500; p = 0 0) (b = 00) (b = 600) (b = 800) (b = 000) (b = 00) 660 series Code: 66000 660060 660080 66000 6600 Technical Brochure: 0 Floor installation kit for box code: 6590 65906 65908 6590 659 66 series Code: 6605 66065 66085 6605 665 Technical Brochure: 0 Box (h= 500; p = 0 50) (b = 00) (b = 600) (b = 800) (b = 000) (b = 00) ACCREDITED We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. ISO 900 FM 65

Caleffi S.p.A. S.R. 9 n. 5 800 Fontaneto d Agogna (NO) Italy Tel. +9 0 89 Fax +9 0 867 info@caleffi.com www.caleffi.com Copyright 05 Caleffi 05075GB