Liquiphant T FTL20H. Technical Information

Similar documents
Vibracon LVL-A* Level limit switch for liquids, compact design

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Liquiphant S, Nivotester FDL60/61, FTL670

Ultrasonic Level Measurement nivopuls FDU 10 S

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

Instruction Manual September 2010 SITRANS LVL200S

Instruction Manual September 2010 SITRANS LVL200S

Operating Instructions 11/2016

1592P01. for liquids in piping DN

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

M7100 Pressure Transducer

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Operating Instructions VEGASWING 63. Vibrating level switch with tube extension for liquids. - two-wire. Document ID: 29232

Operating Instructions 11/2016

Technical Data. Dimensions

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - two-wire With SIL qualification

Technical Data. Dimensions

Soliphant M with electronic insert FEM52

Operating Instructions 11/2016

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Micro/Ultra Filtration System StamoClean CAT 430

Vibrating Switches SITRANS LVL200S TRANSISTOR (NPN/PNP) Operating Instructions 11/2016. Siemens Contro

Rosemount 2100 Series

WIO200 Water In Oil measuring instrument

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Instructions 11/2016

Process Alarm Module RTA 421

Vacuum generators VADM/VADMI

The Liquiphant family Point level detection in liquids using the vibronic measuring principle

Original operating instructions Safety switch with guard locking AC901S AC902S

Flow Measurement SITRANS F C

Technical Data. General specifications. Rated operating distance s n 5 mm

OPTISENS TUR 2000 Technical Datasheet

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Monitoring Devices 11/1

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Class 1 laser beam sensor safe for your eyes

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Inductive slot sensor

Snifter ATEX22 VERSION. User Manual. Distributor

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Class 1 laser beam sensor safe for your eyes

Flow Measurement SITRANS F C

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Condumax CLS16 and CLS16D

Class 1 laser beam sensor safe for your eyes

Turbimax CUE21 / CUE22

Leakage detection sensor

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Technical Data. Dimensions

Turbimax CUE21 / CUE22

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Rosemount 2110 Level Switch

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Technical Data. Dimensions

Operating Instructions Condumax CLS15/16/21

Quick Start Manual July pointek CLS100

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

InductIve SenSorS 2018

/ / 2018

WIO 200B and WIOI200B Water in oil sensor

Parameterisable compact fault annunciator with permanent display

Safety instrumented systems

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Snifter. User Manual. Distributor

OPERATING INSTRUCTIONS MAXIMAT LW CX COMPACT LEAKAGE SENSOR

Micro/Ultra Filtration System StamoClean CAT 430

WIO200 Water in oil sensor

PEPPERL+FUCHS GmbH

FlowJam Bulk Flow Detection

Ultrasonic Point Level Switches

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Capacitive Sensors with a body that is in excellent shape - The 26 Series

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Gas cylinder scale Model GCS-1

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Instructions for the fan motor control system, SILVER C

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Alfa Laval Potentiometric Level Transmitter

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Vacuum suction nozzle OVEM-...-1P/1N

Operating Manual MS220KA and MSR220KA

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

WHG. RoHS. Compliant. Edition February All specifications are subject to change without notice. ( )

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

for relative humidity and temperature

Transcription:

Technical Information Liquiphant T FTL0H Level limit switch for liquids in the foodstuff industry, compact design, housing made of corrosion-resistant stainless steel Application The Liquiphant T FTL0H is a level limit switch for liquids in storage tanks, agitators and pipes which have to meet particularly high hygiene standards internally and externally. It is used in particular in areas where other measurement methods would probably fail: e.g. in the event of viscosity, build-up, turbulences, flows, air bubbles, rash temperature change when cleaning. The Liquiphant T FTL0H is a hygiene version for fluid temperatures up to 150 C. Your benefits E.g. stainless steel housing with round connector M1x1, degree of protection IP69K, always air-tight even in the event of hour-long overflooding and intensive cleaning External test option using test magnet On-site function control using external LED display Large selection of process connections for hassle-free installation in existing systems Easy to install even at points difficult to access due to compact design Rugged stainless steel housing (316L) CIP and SIP cleanability ensured EHEDG certification TI379F/00/en 7109675

Table of contents Function and system design..................... 3 Measuring principle................................... 3 Measuring system..................................... 3 Input...................................... 4 Measured variable.................................... 4 Measuring range...................................... 4 Output..................................... 4 Switching outputs.................................... 4 Operating modes for variants AC and DC-PNP............... 4 Power supply................................ 5 Cable entry......................................... 5 Electrical connection.................................. 6 Performance characteristics..................... 8 Switching delay...................................... 8 Reference operating conditions........................... 8 Measured value resolution.............................. 8 Measuring frequency.................................. 8 Maximum measured error.............................. 8 Repeatability........................................ 8 Hysteresis.......................................... 8 Settling time......................................... 8 Influence of ambient temperature......................... 8 Influence of medium temperature......................... 8 Influence of medium pressure........................... 8 Operating conditions: Installation instructions...... 9 Orientation......................................... 9 Connecting cable..................................... 9 Terminals......................................... 13 Human interface............................ 14 Function test with test magnet.......................... 14 Light signals........................................ 14 Certificates and approvals..................... 17 CE mark, declaration of conformity...................... 17 Sanitary compatibility................................. 17 Overfill protection................................... 17 Marine approval..................................... 17 Other standards and guidelines.......................... 17 Ordering information......................... 17 Liquiphant T FTL0H................................ 17 Accessories................................ 18 Socket wrench...................................... 18 Welding neck G ¾................................... 18 Welding neck G ¾................................... 19 Welding neck G 1................................... 19 Welding neck...................................... 0 Coupling nut....................................... 0 Cable............................................. 0 Supplementary documentation................. 1 Operating Instructions................................ 1 Technical Information................................ 1 Certificates........................................ 1 Operating conditions: Environment............... 9 Ambient conditions................................... 9 Storage temperature................................... 9 Degree of protection................................... 9 Shock resistance..................................... 10 Vibration resistance.................................. 10 Electromagnetic compatibility.......................... 10 Overvoltage protection................................ 10 Operating conditions: Process.................. 10 Medium temperature range and process pressure............ 10 State of aggregation.................................. 10 Density........................................... 10 Viscosity........................................... 10 Gas content........................................ 10 Solids content ø..................................... 10 Mechanical construction...................... 11 Design, dimensions.................................. 11 Process connections.................................. 11 Weight............................................ 13 Materials.......................................... 13 Housing........................................... 13 Endress+Hauser

Function and system design Measuring principle Measuring system The tuning fork of the FTL0H is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics of the FTL0H monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. The measuring system comprises: Liquiphant T FTL0H limit switch Progammable logic control (PLC), miniature contactor, solenoid valve or AS-i bus 1 AS-interface U... PLC 3 ~ 30 V Example 1): Overfill protection or top level detection Example ): Lower level detection or dry running protection Example 3): Dry running protection for pump L00-FTL0Hxx-14-05-xx-en-001 Endress+Hauser 3

Input Measured variable Density Measuring range > 0.7 g/cm 3 Other density settings on request, e.g. 0.5 g/cm 3 Switching outputs Output DC-PNP valve connector DC-PNP M1x1 AC -wire AS-i Function Positive voltage signal at the switch output of the electronics (PNP) Switching the power supply line Switching the D0 bit Switch behaviour ON/OFF 0 / 1 (free / covered) Relay switching capacity 50 ma D0 bit Fail-safe mode MIN/MAX (see below) D1 bit D1: 0 error Switching delay approx. 0.5 s on coverage / approx. 1.0 s on tuning fork becoming uncovered other switching time on request Switching threshold with vertical orientation: 13.0 mm from top of fork with horizontal orientation: 3.5 mm from fork centre Hysteresis 3 ±0.5 mm Operating modes for variants AC and DC-PNP The FTL0H can be connected in two operating modes. By choosing the suitable operating mode (MAX or MIN safety), you ensure that the FTL0H switches safely even in the event of a fault (e.g. if the power supply line is disconnected). MAX - maximum safety The FTL0H keeps the electronic switch closed as long as the liquid level is below the fork. Example of an application: overfill protection MIN - minimum safety The FTL0H keeps the electronic switch closed as long as the fork is immersed in liquid. Example of an application: dry running protection for pumps The electronic switch opens if the limit is reached, if a fault occurs or the power fails. 4 Endress+Hauser

Power supply Cable entry a e f g h 1.).) 7.5 mm i 7.5 mm d b c min. 40 mm min. 40 mm c d c d d d L00-FTL0Hxx-04-05-xx-xx-001 Pg11 / NPT ½ / QUICKON M1x1 (Plastic) M1x1 (Metal) Material: a: Polyamid; b: NBR/SEBS; c: PPSU; d: 316L; e: PUR blue; f: PVC grey; g: PVC transparent; h: PVC orange; i: Cu Sn/Ni Accessories 1.) 4 x 0.34 M1 (Cu Sn/Ni) elbowed (order number: 501085).) 4 x 0.34 + female angled connector M1 (316L) without built-in LEDs (order number: 50416) or 4 x 0.34 + female angled connector M1 (316L) with built-in LEDs (order number: 5018763) Endress+Hauser 5

Electrical connection Variant DC-PNP (direct current) M1x1 connector Voltage source: shock-protected voltage or Class circuit (North America) Suitable for use in non-equivalent operation: When both outputs are connected, the MIN and MAX outputs take on opposite states in trouble-free operation. In the event of an alarm condition or a line break, both electronic switches are open. In addition to level monitoring, function-dependent sensor monitoring can also be performed with the aid of -channel evaluation. Operating mode MAX (NC contact) Operating mode MIN (NO contact) 1 1 4 1 1 4 L00-FTL0xxx-04-05-xx-xx-00 L00-FTL0xxx-04-05-xx-xx-003 1 1: BN 1 1: BN 3 4 : WT 3: BU 3 4 3: BU 4: BK R 0.5 A R 0.5 A L L+ L L+ L00-FTL0xxx-04-05-xx-xx-009 L00-FTL0xxx-04-05-xx-xx-010 Variant DC-PNP (direct current) valve connector Operating mode MAX (NC contact) Operating mode MIN (NO contact) 3 3 3 3 L00-FTL0xxx-04-05-xx-xx-004 L00-FTL0xxx-04-05-xx-xx-005 1 1 3 R 0.5 A + R 3 + 0.5 A PE (Ground) L L+ PE (Ground) L L+ L00-FTL0xxx-04-05-xx-xx-011 L00-FTL0xxx-04-05-xx-xx-01 6 Endress+Hauser

Variant AC (alternating current) valve connector Operating mode MAX Operating mode MIN 1 3 1 1 3 1 L00-FTL0xxx-04-05-xx-xx-006 L00-FTL0xxx-04-05-xx-xx-007 1 1 3 >19V R 0.5 A >19V 0.5 A R PE (Ground) L1 N PE (Ground) L1 N L00-FTL0xxx-04-05-xx-xx-013 L00-FTL0xxx-04-05-xx-xx-014! Note! Approved for relays with a holding power/rated power >.5 VA (53 V) or > 0.5 VA (4 V). Relays with lower holding power/rated power can be operated via a parallel-connected RC-element (option). Connect AS-i bus 1 AS-i + 1: BN 3: BU 3 4 AS-i L00-FTL0xxx-04-05-xx-xx-008 Programming instructions for the AS-i AS-i profile: S-3.A.1 The address is defaulted to 0 (HEX). It is changeable via the bus master or programming unit. Data bit: D0:1 Sensor covered D1:1 Status = O.K. D0:0 Sensor free D1:0 Status = error D and D3 are not used. Parameter bits (P0...P3) are not used. Endress+Hauser 7

Electrical connection DC-PNP valve connector DC-PNP M1x1 AC wire AS-i Supply voltage 10...35 V DC 10...35 V DC 19...53 V AC 4.5...31 V DC Cable entry Pg11 / NPT ½ / QUICKON M1x1 Pg11 / NPT ½ / QUICKON M1x1 Cable specification Max 1.5 mm and ø 3.5...6.5 IEC 60947-5- Max 1.5 mm and ø 3.5...6.5 IEC 606- Power consumption < 85 mw < 85 mw < 810 mw < 85 mw Current consumption < 15 ma < 15 ma < 3.8 ma < 5 ma Residual ripple 5 Vss at 0...400 Hz 5 Vss at 0...400 Hz Performance characteristics Switching delay Reference operating conditions Measured value resolution Measuring frequency Maximum measured error Repeatability Hysteresis Settling time Influence of ambient temperature Influence of medium temperature Influence of medium pressure 0.5 s when covering 1.0 s when becoming free Other switching time on request Ambient temperature: 3 C Process pressure: 1 bar Medium: water Medium density: 1 Medium temperature: 3 C Installation from above/vertical Density setting: > 0.7 < 0.5 mm Approx. 1100 Hz in air 13.0 ±1 mm ±0.5 mm 3.0 ±0.5 mm < s Negligible 9.6 x 10-3 mm/ C 55. x 10-3 mm/bar 8 Endress+Hauser

Operating conditions: Installation instructions Orientation The Liquiphant T FTL0H can be installed in any position in a container or pipe. The formation of foam does not impair its function. 1 3 Example 1): Overfill protection or top level detection Example ): Dry running protection for pump Example 3): Lower level detection L00-FTL0Hxx-11-05-xx-xx-001 Connecting cable Up to 1000 m with AC/DC-PNP, AS-i to IEC 606- Ambient conditions Operating conditions: Environment T a C 60 40 70 50 0 T 0 P 40 0 0 30 60 90* 10 150 C 0 5** 40 * max. 150 ma relay switching capacity ** for AS-i elektronic Ambient temperature T a Process temperature T p L00-FTL0Hxx-05-05-xx-xx-00 Storage temperature 40...+85 C Degree of protection IP65 with valve connector IP66/67 with M1x1 connector PPSU (plastic) IP66/68 with M1x1 connector 316L (metal); IP69K with accessory 504116 (signalling via connector without LEDs) or IP69K with accessory 5018763 (signalling via connector with LEDs) Endress+Hauser 9

Shock resistance To EN 60068--7 (30 g) Vibration resistance To EN 60068--64 Electromagnetic compatibility Overvoltage protection Interference emission to EN 6136, Electrical Equipment Class B, interference immunity to EN 6136, Annex A (Industrial) and NAMUR Recommendation NE 1 (EMC). AS-interface to EN 5095. Overvoltage category III Operating conditions: Process Medium temperature range and process pressure p e bar (psi) 40 (580) 40 ( 104) 0 (3) 1 ( 14.5) 150 (300) T p C ( F) L00-FTL0Hxx-05-05-xx-xx-001 State of aggregation Density Viscosity Gas content Solids content ø Liquid > 0.7 g/cm 3 (other density setting on request) 1...10000 cst Stagnant mineral water < 5 mm 10 Endress+Hauser

Mechanical construction! Note! All dimensions in mm Design, dimensions M1x1 QUICKON Valve connector 30 45 40 ø40 13 * 1 13 * 1 13 * 1 173 36 ø40 ø31.5 ø31.5 ø31.5 38. 38. 38. 179.5 185.5 45.5 8.5 51.5 3 AF 3 AF 3 AF 3.5 * ø17.1 3.5 * ø17.1 3.5 * ø17.1 * * *1 Switch point with vertical installation * Switch point with horizontal installation; the level increases in the direction of the arrow * L00-FTL0Hxx-06-05-xx-en-001 Switch points at: density 1 / 3 C / 0 bar Process connections Process connection / Dimensions Order code Accessories (optional) Pressure Temperature G ½, G ¾ DIN ISO 8/I GCJ GDJ max. 40 bar max. 150 C.7 93 63.9 3 AF 16 38 L00-FTL0xxx-06-05-xx-en-003 Endress+Hauser 11

Process connection / Dimensions Order code Accessories (optional) Pressure Temperature G ¾ DIN ISO 8/I for flush-mounted installation in welding neck EHEDG with welding neck 5018765.7 93 63.9 3 AF 16 38 GDJ Welding neck (with defined thread start) with silicone O-ring Endress+Hauser 5018765 FDA approved materials according to 1 CFR Part 177.1550/600 max. 5 bar max. 150 C max. 40 bar max. 100 C G 1 DIN ISO 8/l L00-FTL0xxx-06-05-xx-en-003 GEJ See also Page 18 max. 40 bar max. 150 C 93 74.5.7 3 AF 18.6 47.9 G 1 DIN ISO 8/I with sealing surface for flush-mounted installation in welding neck EHEDG with welding neck 5001051 (Seal geometry same as e.g. FTL60) L00-FTL0xxx-06-05-xx-en-004 93 74.5.7 3 AF 18.6 47.9 GEJ Welding neck (with defined thread start) with silicone O-ring Endress+Hauser 5001051 FDA approved materials according to 1 CFR Part 177.1550/600 See also Page 19 max. 5 bar max. 150 C max. 40 bar max. 100 C NPT ½ ANSI B 1.0.1 R ½ DIN 999 L00-FTL0xxx-06-05-xx-en-004 RCJ RRJ max. 40 bar max. 150 C 93 (63.9).7 3 AF 47.9 NPT ¾ ANSI B 1.0.1 R ¾ DIN 999 L00-FTL0xxx-06-05-xx-en-005 RDJ RSJ max. 40 bar max. 150 C 93 (63.9).7 47.9 3 AF L00-FTL0xxx-06-05-xx-en-005 1 Endress+Hauser

Process connection / Dimensions Order code Accessories (optional) Pressure Temperature Tri-Clamp DN 5-38 (1½") = ø50.5 mm DN 40-51 (") = ø64.0 mm ISO 85 EHEDG only with " version and special seal. (Seal: manufacturer, Hyjoin Limited, UK) TCJ TDJ max. 16 bar max. 10 C max. bar max. 150 C Clamping ring and front seal are not included and can be purchased from retailers..7 108.8 47.9 Threaded pipe joint DN 5 DN 3 DN 40 DIN 11851 L00-FTL0xxx-06-05-xx-xx-008 Coupling nut and sealing ring are not included and can be purchased from retailers. MNJ MPJ MQJ DN 5, DN 3, DN 40: max. 40 bar up to 100 C max. 5 bar up to 140 C DN 50: max. 5 bar max. 140 C.7 108.8 47.9 Flush-mounted for welding neck 1" Works standard Endress+Hauser with silicone seal and coupling nut (accessory 501715): included EHEDG L00-FTL0xxx-06-05-xx-xx-009 116 5.9.7 47.9 UPJ Welding neck (tuning fork can be aligned) Endress+Hauser 5001047 FDA approved materials according to 1 CFR Part 177.1550/600 See also Page 0 max. 40 bar max. 100 C max. 5 bar max. 150 C L00-FTL0xxx-06-05-xx-xx-010 Weight Materials Housing Terminals Approx. 300 g Sensor and housing made of 316L, surface quality Ra < 1.5 μm (In the area of the weld surface grade is not defined.) Pipe housing Valve connector, QUICKON, M1x1 Endress+Hauser 13

Human interface Function test with test magnet Variants AC and DC-PNP: On testing, the current state of the electronic switch is reversed. Variant AS-interface: On testing, D0 is inverted. Performing test Hold the test magnet against the mark on the nameplate: The switching state changes. L00-FTL0Hxx-19-05-xx-xx-001 Light signals Variants AC and DC-PNP with valve connector/quickon gn rd L00-FTL0Hxx-07-05-xx-xx-001 Green light (gn) lighting: FTL0H is connected to the power supply and is operational. Red light (rd) lighting: Mode of operation MAX (overfill protection): sensor is immersed in liquid. Mode of operation MIN (dry running protection): sensor is not covered by liquid. Green light (gn) does not come on Error: No power supply. Check plug, cable and power supply Red light (rd) flashing: Error: Overload or short-circuit in load circuit. Rectify the short-circuit Reduce maximum load current to below 50 ma Error: Internal sensor error or sensor corroded. Replace device 14 Endress+Hauser

Variant AS-interface and DC-PNP with M1x1 circular connector PPSU gn ye rd L00-FTL0Hxx-07-05-xx-xx-00 Green light (gn) lighting: FTL0H is connected to the power supply and is operational. Yellow light (ye) lighting: Sensor is immersed in liquid. Red light (rd) lighting with AS-interface: Error: Address 0 set or communication error. Carry out addressing process Parameterise slave Or reduce line length (< 100 m total length) Red light (rd) lighting with DC-PNP Error: Overload or short-circuit in load circuit. Rectify the short-circuit Reduce maximum load current to below 50 ma Green light (gn) does not come on Error: No power supply. Check plug, cable and power supply Red light (rd) flashing ( Hz): Error: Internal sensor error or sensor corroded. Replace device Endress+Hauser 15

Variant DC-PNP with M1x1 circular connector 316L ye 1 ye gn L00-FTL0Hxx-07-05-xx-xx-003 Green light (gn) lighting: FTL0H is connected to the power supply and is operational. Yellow light (ye 1) lighting: Sensor is not covered by liquid. Yellow light (ye ) lighting: Sensor is immersed in liquid. Green light (gn) does not come on Error: No power supply. Check plug, cable and power supply Green light (gn) lighting, both yellow lights (ye 1+) does not come on Error: short-circuit in load circuit. Rectify the short-circuit Error: Internal sensor error or sensor corroded. Replace device 16 Endress+Hauser

CE mark, declaration of conformity! Note! Certificates and approvals The specified certificates and approvals are available on www.endress.com/ftl0. The instrument is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. The instrument complies with the applicable standards and regulations as listed in the EC declaration of conformity and thus complies with the statutory requirements of the EG directives. Endress+Hauser confirms the successful testing of the instrument by affixing to it the CE mark. Sanitary compatibility EHEDG (see process connections on Page 11), approval number: 3119/03/0445 Overfill protection Marine approval Other standards and guidelines WHG and leakage German Lloyd (GL), approval number: 4855-0HH AS-i profile S-3.A.1 as per EN 5095 (limit switch) Ordering information Liquiphant T FTL0H 10 Approval: * 0 Non-hazardous area, WHG (leakage monitoring) 3 CSA General Purpose, CSA C US 9 Special version 0 Process Connection: GCJ Thread ISO8 G ½, 316L GDJ Thread ISO8 G ¾, 316L installation > accessory: welding neck GEJ Thread ISO8 G 1, 316L installation > accessory: welding neck RCJ Thread ANSI NPT ½, 316L RDJ Thread ANSI NPT ¾, 316L RRJ Thread DIN999 R ½, 316L RSJ Thread DIN999 R ¾, 316L UPJ Flush-mounted, 316L installation > accessory: welding neck 1" 5001047 TCJ Tri-Clamp ISO85 DN5-38 (1...1½"), 316L TDJ Tri-Clamp ISO85 DN40-51 ("), 316L MNJ DIN11851 DN5 PN40, 316L MPJ DIN11851 DN3 PN40, 316L MQJ DIN11851 DN40 PN40, 316L YY9 Special version 30 Switch Output: 1 -wire 19...53 V AC 3-wire, PNP 10... 35 V DC 3 AS-i bus 9 Special version 40 Application; Cable entry: B 150 C, Plug Pg11, ISO4400, IP65/67 C 150 C, Plug NPT ½, ISO4400, IP65 D 150 C, Plug M1, IP67 E 150 C, Plug QUICKON, IP65 F 150 C, Plug M1, IP69K Y Special version FTL0H Order code * The specified certificates and approvals are available on www.endress.com/ftl0. Endress+Hauser 17

! Note! Accessories All dimensions in mm More detailed information about weld-in adapter can be taken from TI46F/00. Socket wrench Order number: 5010156 Socket wrench AF 3 3 AF L00-FTL0xxx-00-05-xx-en-001 Welding neck G ¾ Order number: 5018765 EN1004 3.1 material with inspection certificate For flush-mounted installation and sealing 6.1 1 max. 5 bar max. 150 C max. 40 bar max. 100 C With defined thread start * Sensor cannot be aligned ø3 G¾ ISO 8 ø50 0.4 Material: corrosion-resistant steel 1.4435 (AISI 316L) Weight: 0.13 kg L00-FTL0xxx-06-05-xx-xx-011 Seal: silicone O-ring Order number: 501717 (5 piece set) FDA approved materials according to 1 CFR Part 177.1550/600! Note! Use only for FTL0 and FTL0H! (Use order number 500105 for FTL50, FTL50H, FTL51, FTL51H) 18 Endress+Hauser

Welding neck G ¾ Order number: 50895 EN1004 3.1 material with inspection certificate For flush-mounted installation and sealing With defined thread start * Sensor cannot be aligned Ø3 0.4 G 3/4 ISO 8 30 5. Ø6 Ø9 max. 5 bar max. 150 C max. 40 bar max. 100 C Material: corrosion-resistant steel 1.4435 (AISI 316L) A000865 Weight: 0.10 kg Seal: silicone O-ring Order number: 501717 (5 piece set) FDA approved materials according to 1 CFR Part 177.1550/600! Note! Use only for FTL0 and FTL0H! (Use order number 7109319 for FTL50, FTL50H, FTL51, FTL51H) Welding neck G 1 Order number: 5001051 Order number: 5011896 EN1004 3.1 material with inspection certificate For flush-mounted installation and sealing With defined thread start * ø41 G1 ISO 8 9.6 4.6 ø60 0.4 max. 5 bar max. 150 C max. 40 bar max. 100 C Sensor cannot be aligned Material: corrosion-resistant steel 1.4435 (AISI 316L) L00-FTL5xxxx-06-05-xx-xx-00 Weight: 0.19 kg Seal: silicone O-ring Order number: 501447 (5 piece set) FDA approved materials according to 1 CFR Part 177.1550/600 * The tolerance of the defined thread beginnings between welding neck and sensor amounts to ± 15. Endress+Hauser 19

Welding neck Order number: 5001047 Order number: 5006909 EN1004 3.1 material with inspection certificate 4.5 For flush-mounted installation and sealing of a Liquiphant FTL50H, FTL0H with process connection EE, UPJ Sensor can be aligned 1 6 RD 5 x ø4.3 ø65 Material: corrosion-resistant steel 1.4435 (AISI 316L) Weight: 0.15 kg ~6 Profile gasket: Silicone Order number: 501444 (5 piece set) L00-FTL5xxxx-06-05-xx-xx-0 FDA approved materials according to 1 CFR Part 177.1550/600 Coupling nut Order number: 501715 for connection UPJ or welding neck 5001047 DIN 11851-F5-1.4301 Weight: 0.17 kg When ordering "process connection for flushmounted installation (UPJ)" the delivery includes the coupling nut. ø63 ø56 ø36 1 1 6 RD 5 x / L00-FTL0Hxx-06-05-xx-xx-007 Cable Order number: 501085 4 x 0,34 M1 socket Cable: PVC (grey) 5 m length Body: PUR (blue) 7.5 Coupling nut: Cu Sn/Ni Protection: IP67 min. 40 Temperature range: 5 C to +70 C L00-FTL0Hxx-07-05-xx-xx-004 Order number: 50416 4 x 0,34 M1 socket Cable: PVC (orange) 5 m length Body: PVC (orange) 7.5 Coupling nut: 316L Protection: IP69K (fully locked) min. 40 Temperature range: 5 C to +70 C L00-FTL0Hxx-07-05-xx-xx-005 0 Endress+Hauser

Order number: 5018763 4 x 0,34 M1 socket with integrated LEDs Cable: PVC (orange) 5 m length Body: PVC (transparent) Coupling nut: 316L Protection: IP69K (fully locked) Temperature range: 5 C to +70 C 7.5 min. 40 L00-FTL0Hxx-07-05-xx-xx-005 Supplementary documentation Operating Instructions Technical Information Certificates! Note! FTL0H KA14F/00/a6 Welding neck G ¾ KA19F/00/a6 Weld-in adapter TI46F/00/de Liquiphant FTL0, FTL0H Allgemeine bauaufsichtliche Zulassung Z-65.11-311 ZE47F/00/de Liquiphant FTL0, FTL0H (Leckage) Allgemeine bauaufsichtliche Zulassung Z-65.40-31 ZE48F/00/de Liquiphant FTL0, FTL0H Number of the Certification Document 3710 ZE49F/00/a Liquiphant FTL0, FTL0H Certificate of Compliance No. 138461 ZE50F/00/en The specified certificates and approvals are available on www.endress.com È download. Endress+Hauser 1

Endress+Hauser

Endress+Hauser 3

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 4153 Reinach Switzerland Tel. +41 61 715 81 00 Fax +41 61 715 5 00 www.endress.com info@ii.endress.com TI379F/00/en/05.09 7109675 SL/FM+SGML6.0 ProMoDo 7109675