Personal ph, ph/orp, Conductivity Meters

Similar documents
Personal ph, ph/orp, Conductivity Meters

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

General Specifications

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Concise catalogue Water-Industry

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Instruments. for hydroponics & horticulture 2016

EXA Conductivity & Resistivity Analysers

General Specifications

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Model Q45P/R. ph/orp Monitor...

General Specifications

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Two global companies, one solution.

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Analytical Testing for Growers. Test crucial parameters in hydroponics and greenhouse applications. hannainst.com/groline

SHAKING WATER BATHS ENGLISH

Compact Ultra Low Temperature Chamber

Model Q45P/R. ph/orp Monitor...

safe and your operations compliant

General Specifications

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Infrared Temperature Sensor

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

SECTION Free/Available Chlorine Analysis System

Bench-Top Type Temperature (& Humidity) Chamber

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 TC

MR SERIES CARD LOGGERS

Durafet Non-Glass ph Electrodes Specifications

Figure 1 DirectLine DL423 Sensor. Description, continued

Steam and Water Analysers

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.

Signet ph/orp Electrodes

WH EN IGH T T C LO SED

64 Max IR Thermometer

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Dräger Pac 5500 Single-Gas Detection Device

Dräger Pac 7000 Single-Gas Detection Device

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

7758 Pipeline Electrode Mountings for Industrial ph and ORP Measurements. Specification. Overview. Description

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

62 MAX/62 MAX + Infrared Thermometer

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Dräger Pac 3500 Single-Gas Detection Device

Vernay-QM Series Disposable Pumps

Retractable ph/orp Sensor

JENCO ELECTRONICS, LTD.

Figure 1 DirectLine DL423 Sensor. Description, continued

T5000 T5000 LCD Digital Fan Coil Thermostat--More Models

IS IP Video Door Phone. FEATURES

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

General Specifications

VersaFlow Mag 2000 FL Electromagnetic Flow Sensor Technical Datasheet. Specification. Solution with high-tech ceramics. Highlights.

Toroidal Conductivity Transmitters Series APT4000 Specifications

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

MT4 MAX/MT4 MAX + Infrared Thermometer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

High Pressure Conductivity Monitor

Free Chlorine Measuring System

Faster Temperature (& Humidity) Chamber

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

STT 3000 Series STT250 /150 Surge Protection Device Specifications

General Specifications

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

+ A B V B NO NC V COM PV PV

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Dräger Pac 8500 Single-Gas Detection Device

SOLUTIONS GUIDE Checker 200 Series. Small, smart, simple, and powerful. Industry Solutions

U5300 Industrial Pressure Transducer

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

T8000 Series T8600 MODBUS Touch Screen Thermostat

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

10A Micro-Ohmmeter Model 6250

AS950 PORTABLE SAMPLERS

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

General Specifications

Humidity Meters HUMIDITY METERS. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health

THE YOKOGAWA PHILOSOPHY

M5200 Industrial Pressure Transducer

Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design)

AQ7275 OTDR Optical Time Domain Reflectometer

M5800 Pressure Transducer with Rotatable Display

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Inductive Conductivity

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

Transcription:

Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/

Compact and lightweight 220g IP67 Waterproof CE,C-tick Compliance Various Convenient Functions Data memory Alarm Clock Date/time display switchable Self-diagnostics Auto power off Personal Series SC72 SC72SN PH71 PH72SN Yokogawa, a pioneer in the design and development of portable water quality meters, has renewed its Personal Series. Bodies are tough and waterproof (IP67). Stylish design with bright new colors. Advanced yet easy-to-use membrane keypad for various and convenient functions such as data memory. PH72 PH72SN

Personal Series are ideal for testing waters outside, laboratory studies, and various other applications. Tough and waterproof construction Conforms to IP67 arge and easy-to-read CD display arge characters Compact and lightweight Fits comfortably your hand and stands firm on the table Features ineup of various sensors Regulatory compliance EMI(Emission) - EN 61326-1 Class B EMS(Immunity) - EN 61326-1 Table 2 (For use in industrial locations) 1 2 3 4 5 6 7 Simple to Use 1 Remaining battery life at a glance ong battery life: 3 Power on/off key Auto power off function 6 Entry keys 200 hours of continuous 4 Easy calibration use (SC72) Automatic/manual calibration 600 hours of continuous use (PH71/72) 5 HOD key 7 DATA key 2 arge and easy-to-read CD Holds the displayed measured display value temporarily arge characters For data setting, range setting, temperature compensation setting, standard solution calibration, cell constant setting (SC72), etc. Gives access to 300 data points (measured values, temperature, date and time)

Dimension PH71, PH72 Personal ph, ph/orp Meter connector for Sensor SC72 Personal Meter connector for Sensor 11 11 PH/ORP Meter Aut Power Off POWER 0 POWER 0 MEAS MEAS CA HOD HOD F/ENT F/ENT DATA DATA 61 42 61 42 ph Sensor for Personal ph, ph/orp Meter Sensor for Personal Meter KCl replenish-free type ph sensor KCl refillable type ph sensor Needle type ph sensor 3000 3000 Sensor for low conductivity measurement General-purpose type sensor 3000 66 6-pin Connector (67) 66 77 6-pin Connector (67) 66 77 6-pin Connector 47 110 172 (67) 105 Protector 28 Protector 28 79 73 Cap 17.5 ø17 Test tube size ph sensor Cap 17.5 ø12 ø17 ORP Sensor for Personal ph/orp Meter 42 24 Chemical-resistant type sensor Sensor for high conductivity measurement KCl refillable type ORP sensor 3000 47 (67) 72 72 185 77 105 105 50 62 Protector 28 ø8 Cap 17.5 ø17 ø12 ø12

, Codes and Specifications Personal ph Meter PH71 ph sensors abel language -00-13 -32-33 -J -E Personal ph meter Without sensor With KCl replenish-free type combination ph sensor (cable length: 0.75 m) With KCl replenish-free type combination ph sensor (cable length: 3 m) With KCl refillable type combination ph sensor (cable length: 0.75 m) With KCl refillable type combination ph sensor (cable length: 3 m) With needle type ph sensor (cable length: 0.75 m) With test tube size ph sensor (cable length: 0.75 m) Japanese English Always Personal ph/orp Meter PH72 Sensors abel language -00-13 -32-33 -43-51 -J -E Personal ph/orp meter Without sensor With KCl replenish-free type combination ph sensor (cable length: 0.75 m) With KCl replenish-free type combination ph sensor (cable length: 3 m) With KCl refillable type combination ph sensor (cable length: 0.75 m) With KCl refillable type combination ph sensor (cable length: 3 m) With needle type ph sensor (cable length: 0.75 m) With test tube size ph sensor (cable length: 0.75 m) With KCl refillable type ORP sensor (cable length: 0.75 m) With KCl refillable type ORP sensor (cable length: 3 m) With KCl refillable type combination ph sensor (cable length: 0.75 m) + KCl refillable type ORP sensor (cable length: 0.75 m) Japanese English Always ph Sensors for Personal ph/orp Meter PH72SN -13-18 * 1-19 * 1-28 * 1-32 -33-38 * 1-39 * 1 *1: Combination of ph sensors for PH81/82 meter with PH71/72 meter will not be IP67 waterproof. ph sensor for personal ph/orp meter For PH71/72: KCl replenish-free type combination ph sensor (cable length: 0.75 m) For PH71/72: KCl replenish-free type combination ph sensor (cable length: 3 m) For PH81/82: KCl replenish-free type combination ph sensor (cable length: 0.75 m) For PH81/82: KCl replenish-free type combination ph sensor (cable length: 3 m) For PH71/72: KCl refillable type combination ph sensor (cable length: 0.75 m) For PH71/72: KCl refillable type combination ph sensor (cable length: 3 m) For PH81/82: KCl refillable type combination ph sensor (cable length: 0.75 m) For PH71/72: Needle type ph sensor (cable length: 0.75 m) For PH71/72: Test tube size ph sensor (cable length: 0.75 m) For PH82: Needle type ph sensor (cable length: 0.75 m) For PH82: Test tube size ph sensor (cable length: 0.75 m) Always ORP Sensors for ph/orp Meter OR72SN* 1 Suffix Code -43-48 * 2-49 * 2 Option Code Description ORP sensor for personal ph/orp meter For PH72: KCl refillable ORP sensor (cable length: 0.75 m) For PH72: KCl refillable ORP sensor (cable length: 3 m) For PH82: KCl refillable ORP sensor (cable length: 0.75 m) For PH82: KCl refillable ORP sensor (cable length: 3 m) Always *1: Cannot be connected to PH81 and PH71 meters *2: Combination of ORP sensors for PH81/82 meter with PH72 meter will not be IP67 waterproof. Specifications of Personal ph/orp Meters Measurement Measurement range Resolution Repeatability (w/o sensor) Display Indication Temperature compensation Calibration Ambient temperature Construction Weight Power source Battery life Functions Regulatory compliance PH71 Hydrogen ion concentration (ph) of solution, 0 to 80 C (or 0 to 100 C* 1 ) 0.01 ph, 0.1 C ±0.01 ph ±1 digit Digital CD ph and solution temperature (simultaneously), sensor check, various messages* 3 Automatic/manual Automatic (1 or 2 point), manual 0 to 50 C IP67 (JIS C0920) 220 g (without sensor) 2 AA size dry cell batteries 600 hours* 2, Auto Power Off function Data memory (300 points), alarm clock, etc. EMI (Emission) - EN 61326-1 Class B EMS (Immunity) - EN 61326-1 Table 2 (For use in industrial locations) *1: When needle type or test tube size ph sensor is connected. *2: When alkaline dry cell batteries are used. *3: When needle type or test tube size ph sensor is connected, liquid temperature can not be measured. Note: of sample solution must be at least 50 µs/cm. PH72 Hydrogen ion concentration (ph) or oxidation-reduction potential (ORP) of solution, ±2000 mv, 0 to 80 C (or 0 to 100 C* 1 ) 0.01 ph, 1 mv (0.1 mv for -199.9 mv to 199.9 mv), 0.1 C ±0.01 ph ±1 digit, ±1 mv ±1 digit Digital CD ph or ORP (mv) and solution temperature (simultaneously), sensor check, various messages* 3 Automatic/manual Automatic (1 or 2 point), manual 0 to 50 C IP67 (JIS C0920) 220 g (without sensor) 2 AA size dry cell batteries 600 hours* 2, Auto Power Off function Data memory (300 points), alarm clock, etc. EMI (Emission) - EN 61326-1 Class B EMS (Immunity) - EN 61326-1 Table 2 (For use in industrial locations)

Standard Accessories for Personal ph/orp Meter (for a set of converter and sensor) AA size dry cell batteries (2 pcs), User's Manual, Quick Manual, non-slip pads (2 pcs), hand strap, Instrument Card * Standard solutions (ph 4, ph 7), calibration ation sub bottles (2 pcs), 3.3 mol/l KCl solution, 5-ml syringe, and cotton swabs are supplied depending on specifications. Specifications of Sensors for Personal ph/orp Meter Sensor KCl replenish-free type combination ph sensor KCl refillable type combination ph sensor KCl refillable type ORP sensor Needle type ph sensor Test tube size ph sensor Measurement Range Wetted Material PH72SN (0.75 m) PH72SN-13 (3 m) PH72SN (0.75 m) PH72SN (3 m) OR72SN (0.75 m) OR72SN-43 (3 m) PH72SN-32 (0.75 m) PH72SN-33 (0.75 m) ±2000 mv ±2000 mv Polypropylene resin (sensor body, protective cover) Glass (glass electrode, temperature sensor protection tube) Ceramics (liquid junction) Silicon rubber (sensor seal) ORP sensor: Platinum (electrode) KCl replenish-free type: PVC (cable), rigid polyethylene (grip), ethylene propylene rubber (grip and cable connection) Glass (sensor body) Glass (sensor body) Personal Meter SC72 sensors abel language Sensor for Personal Meter SC72SN Sensor -19 * -29 * -31-39 * -49 * *Combination of conductivity sensor for SC82 with SC72 meter will not be IP67 waterproof. Specifications of Personal Meter Measurement Unit Measurement range Resolution -00-31 -J -E Repeatability Display Indication Range switching Temperature compensation Ambient temperature Construction Weight Power source Battery life Functions Regulatory compliance Resistivity Temperature Resistivity Temperature *1: Resistivity can be measured for reference. In that case repeatability is determined by conductivity. *2: When measuring range is set to full scale. *3: When alkaline dry cell batteries are used. Personal conductivity meter Without sensor With sensor for low conductivity measurement (cable length: 0.75 m) With general-purpose type sensor (cable length: 0.75 m) With general-purpose type sensor (cable length: 3 m) With chemical-resistant type sensor (cable length: 0.75 m) With sensor for high conductivity measurement (cable length: 0.75 m) Japanese English Always sensor for personal conductivity meter For SC72: Sensor for low conductivity measurement (cable length: 0.75 m) For SC82: Sensor for low conductivity measurement (cable length: 0.75 m) For SC72: General-purpose type sensor (cable length: 0.75 m) For SC72: General-purpose type sensor (cable length: 3 m) For SC82: General-purpose type sensor (cable length: 0.75 m) For SC72: Chemical-resistant type sensor (cable length: 0.75 m) For SC82: Chemical-resistant type sensor (cable length: 0.75 m) For SC72: Sensor for high conductivity measurement (cable length: 0.75 m) For SC82: Sensor for high conductivity measurement (cable length: 0.75 m) Always SC72 of solution S/cm or S/m 0 to 2 µs/cm through 0 to 2 S/cm(depends on sensor to be used) 0 to 40.0 MΩ cm (for sensor for low conductivity measurement) * 1 0 to 80 C 0.05% of full scale * 2 0.1 MΩ cm 0.1 C ±2% (±5% when general-purpose type sensor is used in the range of 0 to 2 ms/cm) Digital CD or resistivity, solution temperature and temperature coefficient (simultaneously), various messages Automatic/manual Temperature coefficient (0 to 9.99%/ C) or NaCl coefficient, reference temperature at 25 C 0 to 50 C IP67 (JIS C0920) 220 g (without sensor) 2 size AA dry cell batteries 200 hours* 3, Auto Power Off function Data memory (300 points), alarm clock EMI (Emission) - EN 61326-1 Class B EMS (Immunity) - EN 61326-1 Table 2 (For use in industrial locations) Standard Accessories for Personal Meter AA size dry cell batteries (2 pcs), User's Manual, Quick Manual, non-slip pads (2 pcs), hand strap, cotton swabs Instrument Card

Specifications of Sensor for Personal Meter Sensor Measurement Range* 1 Cell Constant For low conductivity measurement* 2 SC72SN(0.75m) 0 to 2µS/cm, 0 to 20µS/cm, 0 to 200µS/cm, 0 to 40MΩ cm 0.05cm -1 General-purpose type SC72SN(0.75m) SC72SN (3m) 0 to 20µS/cm, 0 to 200µS/cm, 0 to 2mS/cm, 0 to 20mS/cm, 0 to 200mS/cm 5cm -1 Chemical-resistant type For high conductivity measurement SC72SN-31(0.75m) SC72SN(0.75m) 0 to 2mS/cm, 0 to 20mS/cm, 0 to 200mS/cm, 0 to 2S/cm *1: Fixed range. For automatic range, range is automatically variable. *2: Resistivity can be measured for reference. In that case repeatability is determined by conductivity. 50cm -1 Wetted Material SUS316 (electrode element), fluoro rubber (O-ring), polypropylene resin (insulated area), PVC (cable) Titanium (sensor), fluoro rubber (O-ring), PVC (cable), polyphenylene sulfite resin, polypropylene resin (insulated area, clear cover) Glass, platinum black (electrode element), PVC (cable) Glass, platinum black (electrode element), PVC (cable) Options (Available Separately) For ph and conductivity meters in common For ph and ph/orp meters For conductivity meter Soft carrying case Sensor stand ph 9 standard solution (50 ml) Standard solution (0.1 mol /l NaCl, 250 ml) B9269KJ K9220XN K9220XF K9221ZA Spare Parts For ph/orp meter For ph and conductivity meters in common ph 4 standard solution ph 7 standard solution ph 9 standard solution KCl solution (3.3 mol/l) Quinhydrone reagent Calibration sub bottle Cap set O-ring and gasket set K9084KF K9084KG K9084KH K9220XH K9024EC K9220WW K9220ZY K9654AY 250 ml x 1 bottle 250 ml x 1 bottle 250 ml x 1 bottle 3.3 mol/l KCl solution, 50 ml x 2 bottles 3 packs, 1 pack for 250 ml solution 2 bottles Sensor protective cover and cap Gaskets for battery box (2 pcs) and O-rings for connector (2 pcs) YOKOGAWA EECTRIC CORPORATION World Headquarters 9-32 Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, JAPAN Tel: +81-422-52-6316 Fax: +81-422-52-6619 http://www.yokogawa.com/an/ North America YOKOGAWA CORPORATION OF AMERICA Georgia, U.S.A http://www.yokogawa.com/us/ South America YOKOGAWA AMERICA DO SU TDA. BRAZI http://www.yokogawa.com.br/ Europe YOKOGAWA EUROPE B.V. European Headquarters THE NETHERANDS http://www.yokogawa.com/eu/ YOKOGAWA EECTRIC CIS TD. RUSSIAN FEDERATION http://www.yokogawa.ru/ Middle East YOKOGAWA MIDDE EAST B.S.C.(C) http://www.yokogawa.com/bh/ Singapore YOKOGAWA ENGINEERING ASIA PTE.TD. http://www.yokogawa.com/sg/ Korea YOKOGAWA EECTRIC KOREA CO., TD. http://www.yokogawa.com/kr/ China YOKOGAWA CHINA CO., TD. http://www.yokogawa.com/cn/ YOKOGAWA SHANGHAI INSTRUMENTATION CO., TD. http://www.ysi.com.cn/ YOKOGAWA SICHUAN INSTRUMENT CO., TD. http://www.cys.com.cn/ Taiwan YOKOGAWA TAIWAN CORPORATION http://www.yokogawa.com.tw/ India YOKOGAWA INDIA TD. http://www.yokogawa.com/in/ Australia YOKOGAWA AUSTRAIA PTY. TD. http://www.yokogawa.com/au/ Represented by: Vig-PMK-G N-10E Printed in Japan, 908(KP) [Ed : 03/b] Subject to change without notice. All Rights Reserved, Copyright 2004, Yokogawa Electric Corporation.