FT2080 Fire terminal (Touch) Mounting Installation

Similar documents
FT2080 Fire terminal (Touch) Mounting Installation

Fire control panels FC360

FC722 Fire control panel

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Fire control panels FC726 FC726-XA

FC724 Fire control panel

FC722 Fire control panel

Fire control panel for modernization

FC724 Fire control panel

FC723 Fire control panel

FC2020 Fire control panel

FS20 Fire detection system

Mimic display driver, LED ribbon cable

Output module (230 V)

Input module, input/output modules

Multi line separator module

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Input module, input/output module

FP120-Z1 Power supply kit A (70 W) Technical Manual

Sinteso TM product catalog.

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDBZ290 Air sampling smoke detection kit

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

FDBZ290 Air sampling smoke detection kit

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OH720, OP720, HI720, HI722

FDM273 Radio manual call point Mounting

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

FDCW241 Radio gateway Mounting

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

ASA linear smoke detector

FS720 Fire detection system Planning

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDCL221-M Multi line separator module

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DM1131 / DM1133 / DM1134 Manual call points

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FDOOT221, FDO221, FDT221

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Call stations and extensions

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

DC1192 Input /Output module

Radio fire detection system

DT1101A / DT1102A / DO110xA Automatic fire detectors

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

OOH740, OOHC740 Automatic fire detectors

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FS720 Fire detection system (marine) Technical Manual

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDCIO223 (ES 45) Transponder

1592P01. for liquids in piping DN

Room thermostat with 24-hour time switch and large LCD

FDOOT241-A9-Ex Multisensor fire detector

Frost Protection Thermostat

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FC721 Fire control panel Technical Manual

Flush-mounted room thermostat

Synova TM product catalog.

FDCL221-Ex Line adapter (Ex)

DF1151-Ex Infrared flame detector

Duct Temperature Sensors

Electronic timeswitch

DF1101-Ex Infrared flame detector

Test units and accessories

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FDCI221, FDCIO221 Input module, input/output module Technical Manual

OOH740-A9-Ex Multisensor fire detector

Frost Units for air temperature monitoring

SWING radio fire detection system

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

FDL241-9 Linear smoke detector Mounting Commissioning

FDBZ290 Air sampling smoke detection kit Technical Manual

DOW1171 / DCW1151 Radio fire detection system

FC700A Fire detection control unit

Test units and accessories

OOH740-A9-Ex Multi-sensor fire detector

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

FDA241, FDA221 Siemens ASD

FDA241, FDA221 Siemens ASD

FDCL221 Line separator

5000 Series Rack Panels

Room Temperature Controllers

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

optris Outdoor protective housing

Flush-mounted room thermostats

FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA

Room Temperature Controller

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Service Instructions

Cerberus FIT conventional system

Harvey Chemiclave EC Series Sterilizers

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

ARCHITECT AND ENGINEER SPECIFICATIONS

FT2011 Floor repeater display Operation Manual

Semi flush-mount communicating room thermostats

Transcription:

FT080 Fire terminal (Touch) Mounting Installation 0-09-0 Control Products and Systems

Legal notice Legal notice Technical specifications and availability subject to change without notice. Siemens Switzerland Ltd, 0 Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Issued by: Siemens Switzerland Ltd. Division International Headquarters Gubelstrasse CH-60 Zug Tel. + 7- www.siemens.com/buildingtechnologies Edition: 0-09-0 Document ID: A6V06660

Table of contents Setup of fire terminal (Touch) FT080... Installation in 9" pedestal housing of the FC080...6 Installation in housing (standard)...9 Installation in rear panel (FT080) FHA09... 0 Installation in desktop housing (FT080) FHA00... 6 Technical data...

Setup of fire terminal (Touch) FT080 Setup of fire terminal (Touch) FT080 6 6 Rear panel fire terminal (Touch) FT080 Support plate Front indicator (Touch) FTO00 PMI & mainboard FCM07 x mounting hole operating unit Shield plate above carrier (CPU) 6 Hinges for wall housing

Setup of fire terminal (Touch) FT080 Arrangement of components Components on the fire terminal (Touch) FT080, without cover cap Front indicator (Touch) FTO00 Main network module (SAFEDLINK) on X, optional License key, optional Slot [SER_OPT] for the first serial module at X, optional Slot [SER_OPT] for the second serial module at X9, optional 6 Degraded mode network module (SAFEDLINK) on X, optional 7 CPU module (CORVUS) FCC009 8 Carrier for CPU modules FTO0 9 CPU module (MPC88) FCC006 0 PMI & mainboard FCM07 Slot X for serial module. Not required for FT080 Both slots X and X9 can hold the RS or RS8 serial module.

Installation in 9" pedestal housing of the FC080 Installation in 9" pedestal housing of the FC080 The installation instructions described below apply to all operating units. Before an operating terminal is installed, the following components must first be installed on the operating unit. Network module (SAFEDLINK) FN00-A with ES, for connecting to the FC080 Adapter and connection cable for the power supply Supplied with processor unit (9", FC080) FCC00-A Preparing the operating unit The network module (SAFEDLINK) FN00-A must be installed on connector X of the operating unit (main module slot). 6 8 7 Installing the required options taking operating unit FCM08-A as an example 6

Installation in 9" pedestal housing of the FC080 Operating unit Flange with threaded holes for securing the module Connector strip X for network module Network module (SAFEDLINK) FN00-A with ES x fixing screw 6 PMI & mainboard FCM07 7 Adapter for power supply (including ribbon cable) 8 Connector strip X peripheral data bus connection. Plug the network module (SAFEDLINK) () into connector X () of the operating unit ().. Secure the module to mounting flange () with both screws (). Ensure that it is secured correctly to avoid interrupts.. Plug the adapter (7) into connector X (8) of the PMI & mainboard (6) so inscription 'TOP' is at the top. Installing operating unit Mounting operating terminal in door, taking operating unit FCM08-A as an example Inside of door Opening for operating unit x welded threaded bolt x mounting hole in the operating unit x fixing screw. Remove the cover plate () by removing the four nuts ().. Place the mounting holes () of the operating unit on the four threaded bolts () and screw the operating unit down with the four nuts (). 7

Installation in 9" pedestal housing of the FC080. The operating add-ons in the bottom window openings are installed in the same way.. Wire up the operating unit and operating add-ons according to the following wiring instructions. Wiring the fire terminal (Touch) Wiring the fire terminal (Touch) with FC080 6 Ribbon cable for FC080 system supply to card cage (CPU) X0 FCnet connection to card cage (CPU) X/X X connection to network module (SAFEDLINK) to PMI & mainboard FCM07 Inside of door (section view) Fire terminal (Touch) FT080 6 Adapter for flat cable of the supply FCnet FCnet FC080 Door FCC00 * FCM0xx A B A B A B A B A B A B X X X FN00 FN00 FN00 Example of FCnet wiring of X on PMI & mainboard FCM07 of the fire terminal (Touch) * The FCnet connection from X to X on the card cage (CPU) FCC00 is wired up in advance at the factory. 8

Installation in housing (standard) Installation in housing (standard) Installation of fire terminal in the housing (standard) FH00 Mains connection terminals Power supply unit (70 W) FP0 Rear panel (standard) Fire terminal board FTI00 Wiring FCnet/SAFEDLINK 6 Network module (SAFEDLINK) FN00 7 Fire terminal (Touch) FT080 X Ribbon cable connection from the fire terminal (Touch) to the fire terminal board X Supply input for fire terminal board You will find detailed information on wiring the 'fire terminal board FTI00' and the 'network module (SAFEDLINK) FN00' in document Product Data 00887. 9

Installation in rear panel (FT080) FHA09 Installation in rear panel (FT080) FHA09 The rear panel (FT080) can be used for installation in a desk or installation in a third-party housing. Installing the rear panel (FT080) in a third-party housing guarantees the required EMC protection. The installation sequence is as follows, due to the restricted space: Installing the fire terminal board FTI00 Wiring the fire terminal (Touch) Installing the fire terminal (Touch) Installing the rear panel (FT080) in a desktop View of rear panel (FT080) FHA09 Rear panel (FT080) FHA09 Rear panel (FT080) FHA09 0 V EMC filter, A with plug-in contacts Clamping bracket with screw for ground connection 0

Installation in rear panel (FT080) FHA09 Installing the fire terminal board FTI00 Installing the fire terminal board in the rear panel (FT080) Rear panel (FT080) FHA09 Fire terminal board FTI00 x fixing screw x mounting hole Threaded press-in sleeves in rear cover (FT080). Position the fire terminal board () in the rear panel () as shown.. Use the four fixing screws () to screw the fire terminal board () in the rear panel () firmly onto the threaded press-in sleeves ().

Installation in rear panel (FT080) FHA09 Wiring the fire terminal (Touch) When installing in a desktop that is thicker than mm, the cables must be routed through the rectangular openings of the rear panel (FT080), and not through the round cable breakthroughs. Wiring view of the fire terminal (Touch) in the rear panel (FT080) Fire terminal (Touch) FT080 Network module (FCnet/SAFEDLINK) FN00 FCnet connection cable Prefabricated cable for supply connection to X7 EMC filter 6 Input for DC V system supply to EMC filter 7 Fire terminal board FTI00

Installation in rear panel (FT080) FHA09. Wire up the flat cable from the fire terminal board X to the PMI & mainboard X.. Wire up the prefabricated cable of the supply from the EMC filter to the fire terminal board X7.. Wire up the external cables of the supply, the FCnet and the Ethernet cable through the cut-out in the desktop and the cable lead-throughs in the rear panel. Installing the fire terminal (Touch) 6 7 8 9 Installing the fire terminal (Touch) in the rear panel (Touch) Fire terminal (Touch) FT080 x fixing screw x mounting hole in the fire terminal (Touch) Cable lead-through in the rear panel x threaded hole in the rear panel (FT080) 6 Lateral cable lead-throughs 7 Rear panel (FT080) FHA09 8 Cut-out in the desktop 9 Desktop

Installation in rear panel (FT080) FHA09. Position the wired-up fire terminal (Touch) () on the rear panel (7) as shown.. Screw the four fixing screws () through the holes () to secure the fire terminal (Touch) () into the threaded holes () in the rear panel. Installing the rear panel (FT080) in a desktop 7 6 Installing the rear panel (FT080) in a desktop Rear panel (FT080) FHA09 Mounted fire terminal (Touch) FT080 x fixing screw Mounting holes in the flanges of the rear panel (FT080) Bores in the desktop 6 Desktop 7 Cutout for rear panel (FT080) min. 0 x 68 mm. Place the rear panel () in the cut-out of the desktop (6) as shown. Ensure that the cables are not pinched.. Use the four fixing screws () to screw the rear panel () into the bores () of the desktop at the flanges ().

Installation in desktop housing (FT080) FHA00 Installation in desktop housing (FT080) FHA00 6 7 0 9 8 View of desktop housing (FT080) Top of desktop housing Tilting bracket for top of housing Base of desktop housing Mx0 pan head screw (scope of delivery) Clamping bracket for ground cable (scope of delivery) 6 0 V EMC filter, A with plug-in contacts (mounted) 7 Fixing screw by customer 8 Washer / mm (scope of delivery) 9 x. Rubber grommet (scope of delivery) 0 Spacer sleeves (scope of delivery) Ethernet coupling

Installation in desktop housing (FT080) FHA00. Remove the top of housing () by pushing the two tilting brackets () on the left and right inwards until you can lift off the top of housing.. Connect the ground connection as shown with clamping bracket () and M pan head screw ().. Place the spacer sleeves (0) from below over the rubber feet (9).. Position the housing ().. Place the washers (8) onto the rubber feet (9) inside the housing. 6. Screw the housing () tight with a screw (7) suitable for the substructure. Installing fire terminal board FTI00 Installing fire terminal board in desktop housing Base of desktop housing Fire terminal board FTI00 6x fixing screw (scope of delivery) Spacer with thread in rear panel. Position the fire terminal board () in the housing () as shown.. Screw the fire terminal board () firmly onto the spacers () in the housing () using the four fixing screws (). 6

Installation in desktop housing (FT080) FHA00 Installing fire terminal (Touch) FT080 Mounting fire terminal in the cover of the desktop housing Tilting brackets on left and right for fixing the cover x fixing screw for tilting brackets and fire terminal x fixing screw for fire terminal Fire terminal (Touch) FT080 Cover of desktop housing (FT080) FHA00. Place the fire terminal () in the cover () of the desktop housing as shown.. Screw the tilting brackets () into the cover on the left and right as shown through the top holes in the fire terminal ().. Due to the restricted space available, connect the Ethernet cable to plug X before mounting the fire terminal (Touch).. Use the two other screws to screw the fire terminal () into the cover through the bottom holes. 7

Installation in desktop housing (FT080) FHA00 Assembly of desktop housing (FT080) 6 Assembly of desktop housing Fire terminal (Touch) FT080 Cover of desktop housing (FT080) FHA00 Tilting brackets on left and right for fixing the cover Guide cams on left and right for tilting brackets x threaded holes for mounting cover 6 Base of desktop housing 7 Fire terminal board FTI00. Move the cover () with the installed fire terminal () to the position shown.. Gently press the two tilting brackets () inwards and lift the cover () into the two guide cams (). a The cover is fixed in the open position and the tilting brackets act like hinges. 8

Installation in desktop housing (FT080) FHA00 Securing cover for desktop housing Securing cap (scope of delivery) Opening for fixing screw Cover for desktop housing (Touch) Fixing screw with securing device. To close the housing, tilt the cover () onto the housing and secure the cover to the housing using both screws ().. Close the openings for the fixing screws () using both securing caps () 9

Installation in desktop housing (FT080) FHA00 Fire terminal wiring Wiring view of the fire terminal in the desktop housing Fire terminal (Touch) FT080 Network module (FCnet/SAFEDLINK) FN00 Fire terminal board FTI00 Prefabricated cable for supply connection to X7 fire terminal board FCnet connection cable 6 EMC filter 7 Input for DC V system supply to EMC filter 8 Internal cable RJ for Ethernet connection, L=0 mm 0

Technical data 6 6 Technical data Supply input Voltage DC 0 0 V Quiescent current (display illumination dimmed %) Maximum current (display illumination 00% and lamp test active) 90 ma 700 ma Display Screen size " Resolution 80 x 800 pixels Interfaces x slots for serial modules RS module for event printer RS8 module for ESPA-.. interface, FAT, FBF, UGA or remote EVAC-NL operation x slot for network modules (SAFEDLINK) x Ethernet connection RJ x connection for peripheral data bus Full functionality incl. degraded mode function Degraded mode function only 0/00 Mbit/s X00 Ambient conditions Operating temperature -8 + C Storage temperature -0 +60 C Moisture, condensation not permitted Protection category (IEC609) Max. 9 % rel. IP0 Mechanical data Dimensions (W x H x D) 7 x 00 x mm Weight without options Color FT080-A: g Foil: RAL900 pure white, RAL9006 white aluminum Standards and approvals VdS G0 0786 Siemens Switzerland Ltd, Gubelstrasse FT080 CH-60 Zug, Switzerland Technical data: see doc. 00886 FT080 - Control and Indicating Terminal for use in fire detection and fire alarm systems installed in buildings 00/08/EC (EMC): EN 00- / EN 6000-6- ; 006/9/EC (LVD): EN 6090- ; 0/6/EU (RoHS): EN 08 ; Declared performance and conformity can be seen in the Declaration of Performance and the EC Declaration of Conformity, which is obtainable via the Customer Support center: Tel. +9 89 9-8000 or http://siemens.com/bt/download

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse CH-60 Zug Tel. + -7 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 0 Technical specifications and availability subject to change without notice. Document ID AQ00068 FS0 Edition 0-09-0