GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

Similar documents
Mini-GASS. User Manual. Gas Analysis Sampling System PERMA PURE

Mini-GASS. User Manual. Gas Analysis Sampling System PERMA PURE

Indi-GASS Module Model GM-1024 Sample Conditioning System featuring Nafion Membrane Drying Technology

Mini-GASS Sample Conditioning System User s Manual

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

INSTALLATION. Glass Panel Doors (select models) CAUTION

HW-17 Record Cleaning Machine Setup and Instruction Manual

Eldex Column Heater. Operator s Manual

Heat Exchanger Tube Change Procedure

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

FIREPLACE INSTALLATION

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

MDH Series Air Dryer. User s Guide

High Output Vacuum/Pressure Pump

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Thermo Scientific Air Cadet

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Aerosol Inlet Dryer. User s manual. Part Number: AE33-AEDN. User's manual Version 1.5 December /30

VSA Series Air Dryer. User s Guide

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

F AN-ASPIRATED RADIATION SHIELD

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

F AN-ASPIRATED RADIATION SHIELD

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

R E D I C O N T R O L S

Mustang Vaporizer. Installation, Operation & Maintenance MV

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

A B A B4

TK-1801, TK-1811 TK-1801, TKR-1811

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Heat Exchanger Block Replacement Instructions

TK-1001, 1101, 1201, 1301, 1601

Using the Model 1500 Portable Chilled Mirror Hygrometer

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Arctica Solar 1500 Series Heater Installation Manual

Models Series Series

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

Instant Hot Water Dispenser Owner s Manual

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

Models Series Series

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

GROWMAX WATER Perfect Water for Plants and Gardens

Ozone Generator Systems

Owner s Manual RD432-0 Chemical Controller

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Oil burners fuel unit with solenoid valve

V LPM Desiccant Air Dryer Installation and Operation Manual

HEATING AND AIR CONDITIONING

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

Ozone Generator Systems

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

CORALAIS BODYSPA BATH AND SHOWER FAUCET

IMAGE V. Parts and Service Manual

Model BX-903, BX-904 and BX-906 Environmental Enclosure For BAM-1020 Operation Manual

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS. Principle of operation of CAFM...1. Installation instructions...2. Main ADC Operating screen...3. Set process temp and Setback...

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

INSTANT HOT WATER DISPENSER

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

Apex E Quick Installation Guide

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

CONSTANT SUCTION UNIT

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012

The Technology of Modern Filtration KRAD. Compressed Air Dryer with integrated compressed air filters

Oil burners fuel unit with solenoid valve

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Baldwin -Series Model 8210 Thermo-Electric Cooler User s Manual

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Service Manual Trash Compactor Models 15XESSEXF A November 2010 Broan-NuTone LLC 926 West State Street Hartford, WI

Cabinet Cooler Systems

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Audi-Larm Audible Alarm

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Tornado Operations & Maintenance Manual

KINNEY OIL MIST ELIMINATORS

Service Manual. Trash Compactor. Models 15SSEXF 15BLEXF A November 2010

HEATLESS REGENERATIVE DRYERS

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED

L A signature series TA T N E RE O, A L L A T S IN

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

BLAST-IT-ALL BUMPER BLASTER

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

HORIZONTAL AGITATOR ASSEMBLY

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

MILLENIUM MEMBRANE REPLACEMENT. Tools and Materials Required. Initial Preparation

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Transcription:

GASS Module Gas Analysis Sampling System User Manual PERMA PURE 8 Executive Drive Toms River, N.J. 08755 Phone: 800-337-3762 732-244-0010 Fax: 732-244-8140 e-mail: info@permapure.com Web Site: www.permapure.com

TABLE OF CONTENTS 1. Introduction...4 2. GASS Module Component...5 2.1 Filter 2.2 Automatic Filter Drain (optional) 2.3 Filter Thermocouple (optional) 2.4 Purge Eductor (optional) 2.5 Nafion Dryer 3. Installation...8 3.1 Mounting 3.2 Electrical Connection A. Filter Section 1. Filter Heater 2. Filter Heater Thermocouple (Optional) 3. Automatic Drain (Optional) B. Dryer Section 1. Dryer Heater 2. Dryer Heater Thermocouple C. Ground Wire Connection 3.3 Plumbing A. Sample Connection B. Purge Inlet Connection C. Purge Exhaust/filter Drain Connection D. Purge Eductor Inlet Connection 4. Start-Up Procedure...11 4.1 Setup Check 4.2 Purge Air Flow Adjustment 4.3 Preheating the System 5. Maintenance...12 5.1 Filter 5.2 Dryer Appendix A - Specifications...14 Appendix B - PD Dryer Element Replacement...15 2

WARNING Thank you for purchasing sample gas conditioning equipment from Perma Pure LLC. We want your new sample gas conditioning equipment to operate safely. Anyone who installs or uses this equipment should read this publication before installing or operating this equipment. To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and usually change with time. It is your responsibility to determine which codes should be followed and to verify the equipment, installation and operation is in compliance with the latest revision of these codes. At a minimum, you should follow all applicable sections of the National Fire Code, National Electrical Code, and the codes of the National Electrical Manufacturer s Association (NEMA). There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation. Equipment damage or serious personal injury can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your system design, installation or operation. This product should not be operated in any manner that is inconsistent with its intended use. If you have any questions concerning the installation or operation of this equipment, or you need additional information, please call us at 1-800-337-3762. TRADEMARKS This publication is based on information that was available at the time it was printed. At Perma Pure we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Trademarks Nafion and Teflon are registered trademarks of EI DuPont de Nemours Copyright 1996-2005, Perma Pure LLC. All Rights Reserved. 3

1. Introduction Perma Pure GASS Module sample conditioning systems are designed to prepare gas samples for analysis. The GASS Module system will remove, particulates, mists and water vapor without removing compounds being monitored. A heated sample line is connected to the top fitting on the GASS Module (see Figure 1). Sample gas flows to the filter where particulates are removed and/or mists are coalesced. After filtration, sample is passed through the Nafion Dryer where water vapor is selectively removed. Sample is now ready for analysis. Standard Features Include: Filter - Particulate and/or Coalescing Perma Pure Nafion Gas Dryer Purge Eductor Filter Thermostat Dryer Heater Thermocouple Module Housing Mounting Clamps Options: Automatic Filter Drain Filter Heater Thermocouple and Extension Wire Figure 1 4

2. GASS Module Components Filter: Automatic Filter Drain (optional) First step in conditioning the sample is to filter out particulates and aerosols by passing it through a 1µ filter consisting of a borosilicate glass filter element with a fluorocarbon binder. The element is disposable and will withstand high sample temperatures. If coalescing is anticipated, the system should be fitted with an automatic filter drain to periodically remove collected liquid mists (in most cases it is acid mist). The automatic drain will operate in a vacuum or pressurized system. 1. Vacuum Configuration Collected liquid is withdrawn from the filter drain port by a strong vacuum. The vacuum is created by an eductor expanding compressed air through a venturi which should be controlled in cycles by an adjustable digital timer (provided by customer). The timer switches a solenoid valve and controls compressed air supply. 2. Pressurized Application An eductor is not required since a vacuum is not needed to withdraw the sample. Therefore, the condensate withdraw is directly controlled by the solenoid valve. Cycle times can be varied and will be dependent on the amount of liquid present in the sample. Filter Thermocouple (optional) Purge Eductor (optional) Nafion Dryer The filter heater comes standard with a thermostat wired in and preset at 90 C but if sample condensate is anticipated, an additional temperature controller should be used in place of the thermostat to control the heater at a lower temperature. Eductor generates a vacuum to draw condensate from the filter and to drop pressure of the purge gas to prevent collapsing of Nafion tubing. The Perma Pure Nafion membrane dryer is installed downstream of the filter. As sample enters the dryer, the flow splits into a number of small diameter Nafion membrane tubes which are arranged in a parallel bundle as shown in the figure below. The shell and multitube moisture exchangers transfer water vapor between two countercurrent flowing gas streams as seen in the drawing below. Dry purge gas flowing over the exterior surface of the Nafion tubing continuously extracts water vapor from the gas stream inside the tubing. The driving force is the difference in water concentration on the opposite sides of the tubing wall. The purge gas then carries the water vapor away. Dry purge gas enters the dryer at the sample outlet end and performs two functions: 1. Provides a medium for the water vapor from the sample to be carried away. 2. Creates the temperature gradient along the length of the dryer. 5

Ambient purge air enters the dryer at the sample outlet keeping that portion of the dryer cooled. This counter current flow is required to produce a temperature gradient along the length of the dryer. To effectively maintain the gradient, the temperature of the purge gas exhaust must be monitored and controlled by an electronic temperature controller (customer provided). As purge gas passes through the dryer, it is heated to desired sample inlet set point temperature. This gradient allows for both rapid vapor removal and decreased final dew point. If purge gas temperature begins to fall below the set point, module s heaters will adjust to maintain the set point. The aluminum housing will conduct energy from the heaters to the dryer s shell tube. Purge gas traveling through the dryer s shell, acquires heat from the shell. This process allows final temperature of the purge gas to be closely controlled and a consistent temperature gradient will be maintained. It is important that the dryer removes water in vapor state only to avoid problems that arise when the membrane comes in contact with liquid water. If liquid water is introduced into the dryer, efficiency will decline and the dryer could fail to perform altogether. Tubing elongates approximately 10% over its dry length when saturated with liquid water causing tubing to kink inside the dryer housing, reducing drying. Nafion dryers will operate most efficiently when a portion of the dryer is heated to prevent sample from condensing out liquid water. 6

3 Installation (see Figure 2 for reference.) 3.1 Mounting Unit should be shielded from direct rain and snow. Do not install outdoors if temperature will fall below -10 C. 1. Module must be arranged on vertical surface with filter section on top and dryer sample outlet/purge inlet on bottom. 2. Remove mounting clamps from GASS Module. 3. Mount to rigid surface through mounting slots (spaced 2 5/8" apart). 4. Place GASS Module into clamps and secure. 3.2 Electrical Connections GASS Module is equipped with two separate heater assemblies. One heater is located on top portion (filter section) and other heater is placed on bottom portion (dryer section). Both heaters require an AC power source. A. Filter Section Filter Heater Connection 1. Locate 5 pole connector (labeled Filter Heater Connection ). These wires are connected to a thermostat in filter section that is pre-set to 90 C. 2. Connect heater wires to 115 VAC or 230 VAC power source (see Figure 3). 110 VAC 220 VAC Figure 3 8

Filter Heater Thermocouple Connection (Optional) If sample condensate is expected, an automatic drain assembly is used, a second therm couple is mounted on the filter section. This thermocouple must be wired to an additional temperature controller provided by customer. 1. Locate thermocouple mounted through outer insulation on filter section (labeled Filter Heater Thermocouple ). 2. Connect Type J thermocouple extension wire from connector provided to an additional temperature controller. This controller will be used to control filter heater s power instead of internal pre-set thermostat. Automatic Filter Drain Valve Connection (Optional) Optional solenoid valve can be connected to filter section if automatic draining of sample condensate is desired. 1. Locate Automatic Filter Drain Valve two pole connection. 2. Connect to customer s control system. B. Dryer Section WARNING! Dryer Heater Connection DO NOT connect directly to AC power. Doing so will cause permanent damage to Nafion dryer. 1. Locate 3 pole connector (labeled Dryer Heater ). 2. Connect wires to customer supplied PID type temperature controller. Dryer Heater Thermocouple Connection 1. Locate thermocouple mounted in tee fitting of purge outlet port (labeled Dryer Thermocouple Type J ). 2. Connect Type J thermocouple extension wire provided to customer supplied temperature controller to control dryer heater power. C. Ground Wire Connection 1. Locate green wire separate from any other wiring harnesses. 2. This is the grounding wire for the GASS Module. 3. Connect grounding wire to appropriate earth ground. 9

3.3 Plumbing A. Sample Connection 1. With unit securely mounted, connect sample line directly to ¼ or 3/8" compression fitting on top of module. The 3/4 SS nipple sample inlet connection can be used to attach customer supplied conduit fitting for rigid connection to heated sample line (see Figure 4). If it is not being used,ensure it is well insulated to prevent cold spots which causes sample condensation. 2. Connect ¼ NPT sample outlet port of GASS Module to sample line running to analyzer. B. Purge Inlet Connection Purge gas must be of instrument grade with a dew point no higher than 40 O C. 1. Purge gas should be supplied to dryer via 0-30 slpm flowmeter and a regulator capable of supplying 0-50 psig. Refer to flow schematic for proper setup. 2. Connect regulated purge gas supply line to 1/8" female NPT purge inlet port of membrane dryer (labeled Instrument Air ). C. Purge Exhaust/Filter Drain Connection With optional automatic filter drain With auto drain option, purge gas exhaust is combined with the filter drain. Therefore, exhaust may contain acid condensate when drain valve is energized. Connect line from eductor outlet to designated collection/exhaust basin containing acid absorption media to prevent release of exhaust to surrounding. Line should not restrict purge flow. A ¼ I.D. tubing can be used for runs up to 10 feet, or larger I.D. tubing for longer exhaust lines. Without optional automatic filter drain Purge exhaust may contain water vapor. A line can be connected from purge outlet to remote area if desired. Line should not restrict purge flow. A 1/4" I.D. tubing can be used for runs up to 10 feet, or larger I.D. tubing for longer exhaust lines. D. Purge Eductor Inlet Connection Figure 4 Connect compressed air supply line to nozzle of eductor inlet via regulator capable of supplying 0-50 psig. 10

4 Start-Up Procedure 4.1 Setup Check 1. Check electrical, sample, purge, and drain connections have been made and set temperature controller(s) to desired setpoint(s). 2. Turn on instrument and/or compressed air to system. 4.2 Purge Air Flow Adjustment 1. To achieve correct vacuum of 5 Hg to drain acid condensate from filter, set purge air eductor pressure to 25 psig. 2. Adjust purge air flow to 20 l/min before applying power to temperature controller. 3. Check purge air is exhausting from system. 4.3 Preheating the System 1. Turn on AC power to system. WARNING! DO NOT BEGIN SAMPLE FLOW AT THIS TIME! If, for any reason, there is no purge air or flow is inadequate, turn off AC power before attempting to locate problem. Operating system with little or no purge air can cause permanent damage to membrane dryer assembly. 2. Recheck purge air is exhausting from system. 3. Set temperature controller of dryer heater 5-10 C above expected sample dewpoint temperature. 4. Do not flow sample until dryer temperature has come up to desired setpoint. 5. If temperature controller is utilized to control filter heater, set it s temperature slightly above expected sample dewpoint temperature. 6. Wait for filter to come to set temperature. 7. At this point, sample flow may be started. 11

5 Maintenance 5.1 Filter The system is fitted with a coalescing filter element which should be checked regularly to ensure that element is in good condition. If element appears to be dirty or begins to cause flow restriction in system, it should be replaced. Filter Element Replacement: 1. For ease of filter replacement, GASS Module should remain mounted. 2. Stop sample flow. 3. Disconnect sample inlet line from top of module (see Figure 5). 4. Hold module cap with one hand and pull ring on cap with other hand. 5. While pulling ring out, rock cap and pull upward to release o-ring seal in filter housing. 6. Remove filter element from inside housing. 7. Position new element on filter/module cap by centering element on cap assembly. 8. Apply thin layer of silicone-based lubricant on o-ring of filter cap. 9. Carefully insert filter element (while on cap assembly) back inside filter housing. 10. Reattach module cap. 11. Ensure o-ring on filter cap is properly seated to prevent sample gas from leaking. 12. Reconnect sample line to inlet of GASS Module. 5.2 Dryer Dryer element replacement: Tools Needed: - Allen wrench - Snap ring pliers - Pair of lightweight gloves 1. Follow Steps 1-6 for filter element replacement. 2. Disconnect all wiring. 3. Remove assembly out of mounting clamps. 4. Remove Eductor and Drain (if optioned). 5. Remove Dryer Assembly from housing. 6. Follow PD dryer element replacement in Appendix B. 12

Filter Element Module Cap Module Housing Bottom End Nut Dryer Housing Shims Dryer Housing Eductor Ring End Nut & Filter Housing Mounting Clamps Figure 5 13

APPENDIX A - Specifications MAXIMUM SAMPLE FLOW RATE: 0 TO 10 LITERS/MIN MAXIMUM INLET SAMPLE TEMPERATURE: 275 F MAXIMUM GAS SAMPLE WATER VAPOR CONTENT: 30% OUTLET SAMPLE DEW POINT: (With PD-200T-24" dryer) (With PD-100T-24" dryer) (With PD-50T-24" dryer) 26 F (-4 C) at 10 L/MIN 12 F (-12 C) at 5 L/MIN -12 F (-25 C) at 2 L/MIN 36 F (2 C) at 10 L/MIN 26 F (-4 C) at 5 L/MIN 6 F (-15 C) at 2 L/MIN 42 F(5 C) at 10 L/MIN 34 F(1 C) at 5 L/MIN 22 F(-6 C) at 2 L/MIN SOLUBLE GAS REMOVAL RATES: NO, NO2 0% loss SO2 0% loss CO, CO2 0% loss H2S, HCl 0% loss MAXIMUM GAS SAMPLE INLET PRESSURE: MINIMUM GAS SAMPLE INLET PRESSURE: GAS SAMPLE INLET FITTINGS: GAS SAMPLE OUTLET FITTINGS: AIR REQUIREMENTS: ELECTRICAL REQUIREMENTS: CUSTOMER SUPPLIED FUSE OPERATING ENVIRONMENT: 10 PSIG 10" H2O VACUUM WITHOUT EDUCTOR OPTION 1/4" or 3/8" TUBING FITTINGS 1/4" NPT PURGE AIR -40 C DEW POINT MAXIMUM ONE (1) CFM 110/220VAC, 50/60 Hz -20 C TO 40 C AMBIENT TEMP 0 TO 95% R.H. 14

APPENDIX B - PD DRYER ELEMENT REPLACEMENT PD WITH TWO PART END FITTINGS TO DISASSEMBLE DRYER (see PD drawing below) Tools Needed: -Allen wrench 3/32 -Snap ring plier -Pair of lightweight gloves 1. Hold coupling and shell with one hand, and remove front nut on each end with the other. 2. Loosen set screws on both ends of couplings using Allen wrench. 3. Remove snap ring from both sides using snap ring pliers. 4. Put on pair of lightweight gloves(protects membrane tubing from skin oils contaminating surface and reducing drying efficiency). 5. Pull element header out of housing on one side to expose o-ring. Do not rotate more than 10 in either direction. 6. Remove inner o-ring. 7. Gently pull element out other end. 8. Reverse procedure to assemble dryer. Two Part End Fitting PD Dryer 15

PD WITH ONE PART MOLDED FITTINGS TO DISASSEMBLE DRYER (see Molded PD Dryer Drawing below) Tools Needed: - Phillips head screwdriver - unsharpened pencil with eraser 1. Loosen locking screws on both ends of dryer. 2. Insert eraser end of pencil into one sample port until it rests on tube header face(see Figure on right). 3. Hold dryer vertically and place other end of pencil down onto a hard, slip resistant surface. 4. While supporting shell tube of dryer, push lower end fitting down with consistent pressure until it slips off shell tube. Do not attempt to pull fitting from shell tube; doing this is likely to damage dryer element tubing. 5. Repeat steps 2-4 for other end. 6. Remove one o-ring from tube header. 7. Pull tube element from opposite end of dryer. Tube Header TO ASSEMBLE DRYER Tool Needed: - Phillips head screwdriver 1. Install one thick o-ring onto grooved tube header. 2. Slip opposite tube header into dryer shell. 3. Install other thick o-ring onto groove. 4. Push one thin o-ring into groove inside coupling (for SS and AL shells slip o-ring on shell across two holes). 5. Firmly push coupling over tube header. 6. Align purge port with hole in shell tube(see Figure on right). 7. Tighten locking screws until underside of screw head contacts top of boss. 8. Repeat steps 4-7 for opposite end. Check for Alignment Sample Port 16