Safety instructions VEGASWING 61, 63

Similar documents
Safety instructions Display and adjustment module

Safety instructions VEGATOR 121, 122

Safety instructions VEGAVIB 61, 62, 63

Safety instructions VEGAPULS 62

Safety instructions VEGACAP 62, 63, 64, 65, 66

Safety instructions VEGAPULS 69

Safety instructions VEGAPULS 64

OPTIBAR DP 7060 Supplementary Instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Safety instructions VEGABAR 81, 82, 83, 86, 87

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. Dimensions

Technical Data. Dimensions

Manufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

User s Manual YTA610 and YTA710 NEPSI Certification

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

OPTIWAVE X500 Supplementary Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Hygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Safety instructions VEGAMIP MPR61(*).G*/DK****R/T*** VEGAMIP MPT61(*).G*/DK****T*** VEGAMIP MPR62(*).G******R/T*** IECEx BVS Ex t IIIC T..

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Physikalisch-Technische Bundesanstalt

Dual certification! Air handling units for potentially explosive atmospheres

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Mounting instructions. Rinsing connection. for VEGAPULS WL 61, 61, 64, 67 and 69. Document ID: 49552

ATM Lighting sp. z o.o

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Supplementary instructions Bypass 72 Bypass tube with VEGAFLEX level sensor

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

VERSAFLOW VORTEX Supplementary instructions

IECEx Certificate of Conformity

IECEx Certificate of Conformity

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

SEK-3 Marine Grounding System

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EU DECLARATION OF CONFORMITY

Certificate of Compliance

Guide for hazardous areas

UL HAZARDOUS LOCATIONS SERVICES

ATM Lighting sp. z o.o

Operating Instructions Edition 02/2007

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Temperature sensors SensyTemp TSP Measuring insets TSA

ATEX Explained A brief Introduction

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Installation and Operating Instruction

Ex Products Highest level of safety under the most difficult conditions

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

SET Installation and Operating Instructions. Level switch for one sensor

TRASCO ATEX Couplings

OilSET-1000 (12 VDC)

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Temperature Measurement Transmitters for field mounting

SET-2000 Oil/Sludge 12 VDC

Manual Power relay SR853

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Snifter ATEX22 VERSION. User Manual. Distributor

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Manual Isolating Barrier D461R1 (Revision 01)

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

SET-2000 Hi Level/Oil

Multipoint temperature sensor

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Operating Instructions. Conductive probe EL 1. Conductive rod electrode. Document ID: 32651

Electrical Installations Design, Selection, Erection and Inspection

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

Rules for Classification and Construction Additional Rules and Guidelines

ATEX Safety Switches. More than safety.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Explosion-protected actuator Page 259 of 292

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Certificate of Compliance

Operating Instructions Conductive probe EL 1

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Zellenradschleusen / Rotary Valves / Válvulas Rotativas

Annubar Flowmeter Series

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

ANNEX GD-CERT-EX-EN SIT

Transcription:

Safety instructions Intrinsic safety NAMUR 0044 Document ID: 50660

Contents 1 Area of applicability... 4 2 General information... 4 3 Technical data... 5 4 Application conditions... 6 5 Protection against static electricity... 8 6 Installation/construction... 8 7 Impact and friction sparks... 8 8 Use of an overvoltage arrester... 8 9 Material resistance... 9 10 Grounding... 9 Please note: These safety instructions are part of the operating instructions: 29226 - VEGASWING 61 - NAMUR 29231 - VEGASWING 63 - NAMUR 50661 - EU type approval certificate PTB 00 ATEX 2217 X, Ausgabe 01 Editing status: 2017-01-27 2

DE EN FR IT ES PT NL SV DA FI EL DE EN FR ES Sicherheitshinweise für den Einsatz in explosionsgefährdeten Bereichen Safety instructions for the use in hazardous areas Consignes de sécurité pour une application en atmosphères explosibles Normative di sicurezza per l'impiego in luoghi con pericolo di esplosione Instrucciones de seguridad para el empleo en áreas con riesgo de explosión Normas de segurança para utilização em zonas sujeitas a explosão Veiligheidsaanwijzingen voor gebruik op plaatsen waar ontploffingsgevaar kan heersen Säkerhetsanvisningar för användning i explosiionsfarliga områden Sikkerhedsforskrifter til anvendelse i explosionsfarlig atmosfare Turvallisuusohjeet räjähdysvaarallisisssa tiloissa käyttöä varten Υποδείξεις ασφαλείας για τη χρησιμοποίηση σε περιοχές που υπάρχει κίνδυνος έκρηξης Die vorliegenden Sicherheitshinweise sind im Download unter www.vega.com standardmäßig in den Sprachen deutsch, englisch, französisch und spanisch verfügbar. Weitere EU-Landessprachen stellt VEGA nach Anforderungen zur Verfügung. These safety instructions are available as a standard feature in the download area under www.vega.com in the languages German, English, French and Spanish. Further EU languages will be made available by VEGA upon request. Les présentes consignes de sécurité sont disponibles au téléchargement sous www.vega.com en standard en allemand, en anglais, en francais et en espagnol. VEGA met à disposition d'autres langues de l'union Européenne selon les exigences. Las indicaciones de seguridad presentes están disponibles en la zona de descarga de www.vega.com de forma estándar en los idiomas inglés, francés y español. VEGA pone a disposición otros idiomas de la UE cuando son requeridos. 3

1 Area of applicability These safety instructions apply to the vibrating level switches VEGASWING61/63.CX*****N/W** according to EU type approval certificate PTB 00 ATEX 2217 X, issue 01 (certificate number on the type label) and for all instruments with the number of the safety instruction (50660) on the type label. Subject of the evaluation of VEGASWING in the version with flame proofing intrinsic safety "Ex i" are the types VEGASWING61/63.CX*****N/W**. The versions VEGASWING61/63.CX*****N/W** with the features "CA", "CM" and "CK" on the type label are certified version with flame proofing intrinsic safety or flame proofing intrinsic safety also with a ship certificate/overfill protection or dust certificate. Feature "CX" in the type code: Feature "CA" in the type code: Feature "CM" in the type code: Feature "CK" in the type code: Certificate intrinsic safety Ex ia Certificate intrinsic safety but also overfill protection Certificate intrinsic safety but also ship certificate Certificate intrinsic safety but also dust certificate The dust-explosion protection, the ship certificate and the certification as overfill protection are not subject of the assessment and evaluation acc. to the EU Type approval certificate PTB 00 AT- EX 2217 X, issue 01. 2 General information The VEGASWING61/63.CX*****N/W** are used for monitoring and control of levels. The measured products can also be combustible liquids, gases, mist or vapour. The VEGASWING61/63.CX*****N/W** are suitable for use in hazardous atmospheres of all combustible materials of explosion group IIA, IIB and IIC for applications requiring instruments of category 1G, category 1/2G or category 2G. If the VEGASWING61/63.CX*****N/W** are installed and operated in hazardous areas, the general Ex installation regulations EN 60079-14 as well as these safety instructions must be observed. The operating instructions as well as the installation regulations or standards that apply for explosion protection of electrical systems must generally be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. Category 1G instrument (EPL-Ga instrument) The VEGASWING61/63.CX*****N/W** are installed in hazardous areas requiring an instrument of category 1G. Category 1/2G instrument (EPL-Ga/Gb instrument) The electronics housing is installed in hazardous areas requiring an instrument of category 2G. The process connection element is installed in the separating wall, which separates areas requiring instruments of category 2G or 1G. The antenna system with the mechanical fixing element is installed in hazardous areas requiring instruments of category 1G. Category 2G instrument (EPL-Gb instrument) The VEGASWING61/63.CX*****N/W** are installed in hazardous areas requiring an instrument of category 2G. Ignition protection label II 1G, II 1/2G, II 2G Ex ia IIC T6 Ga, Ga/Gb, Gb Important specification in the type code VEGASWING SG61/63(*).abcdefghij 4

Position Feature Description ab - Approval cde - Process fitting / Material f - Adapter / Process temperature g - Housing / Protection / Cable gland CX CM CA CK ATEX II 1G,1/2G, 2G Ex ia IIC T6 Ga, Ga/Gb, Gb ATEX II 1G,1/2G, 2G Ex ia IIC T6 Ga, Ga/Gb, Gb + Ship approval ATEX II 1G,1/2G, 2G Ex ia IIC T6 Ga, Ga/Gb, Gb + Overfill protection (WRA) ATEX II 1G,1/2G, 2G Ex ia IIC T6 + II 1/2D, 2D Ex td ** Process fittings acc. to industry standard * P N M Plastic single chamber / IP66/IP67 / M20x1,5 Plastic single chamber / IP66/IP67 / ½NPT Aluminium single chamber / IP66/IP67 / M20x1,5 7 Special colour Aluminium single chamber / IP66/IP67 / M20x1,5 U Aluminium single chamber / IP66/IP67 / ½NPT 4 Special colour Aluminium single chamber / IP66/IP67 / ½NPT 3 Aluminium single chamber / IP66/IP68 (1bar) / M20x1,5 V A Stainless steel single chamber (precision casting) / IP66/IP67 / M20x1,5 Stainless steel single chamber (precision casting) / IP66/IP67 / ½NPT 5 Stainless steel single chamber (precision casting) / IP66/IP68 (1bar) / M20x1,5 8 Stainless steel single chamber (electropolished) / IP66/IP67 / M20x1,5 9 Stainless steel single chamber (electropolished) / IP66/IP67 / ½NPT * Further housings with suitable plug connectors and special colours h - Electronics N NAMUR signal i - Switching point * j - Measurement loop identification label W 3 Technical data * NAMUR signal (250 ms) Electrical data The VEGASWING61/63.CX*****N/W** have intrinsically safe circuits. These intrinsically safe circuits are connected to terminals which are located in an "Ex i" connection compartment. 5

Supply and signal circuit Terminals 1[+], 2[-] In ignition protection type intrinsic safety Ex ia IIC/IIB Only for connection to a certified, intrinsically safe circuit. Maximum values: U = 20 V i I = 103 ma i P = 516 mw i L = negligibly small i In the version with fix mounted connection cable L i ' = 55 µh/m. C = 2.2 nf i In the version with fix mounted connection cable C i wire/wire = 58 pf/m and C i wire/screen = 270 pf/m must be also taken into account. The intrinsically safe circuits are electrically separated from parts which can be grounded. For applications requiring instruments of category 2G or 1/2G, the intrinsically safe power supply and signal circuit can correspond to protection class ia or ib. For connection to a circuit of category ib, the ignition protection type identification is Ex ib IIC T6 Gb. For applications requiring instruments of category 1G, the intrinsically safe power supply and signal circuit must be in conformity with category ia. For applications requiring instruments of category 1G the VEGASWING61/63.CX*****N/W** is preferably connected to appropriate instruments with electrically isolated, intrinsically safe circuits. 4 Application conditions Permissible ambient temperatures On the sensor, category 1G Temperature class T6-20 +51 C T5, T4, T3, T2, T1-20 +60 C On the sensor, category 1/2G Temperature class T6-20 +85 C T5-20 +100 C T4-20 +135 C T3 without temperature adapter -20 +150 C T3 with temperature adapter -20 +200 C T2, T1 with temperature adapter -20 +250 C If the sensors of VEGASWING61/63.CX*****N/W** are operated at temperatures higher than those specified in the above table, please make sure by means of appropriate measures that there is no danger of ignition from hot surfaces. The temperature on the electronics/housing must not exceed the values specified in the above table. 6

Please make sure that the sensor (also in case of failure) does not generate heat itself. Responsibility for safe operation of the equipment, with respect to pressures/temperatures of the materials used, rests with the operator. On the sensor, category 2G Temperature class T6-40 +85 C T5-40 +100 C T4-40 +135 C T3 without temperature adapter -40 +150 C T3 with temperature adapter -50 +200 C T2, T1 with temperature adapter -50 +250 C If the sensors of VEGASWING61/63.CX*****N/W** are operated at temperatures higher than those specified in the above table, please make sure by means of appropriate measures that there is no danger of ignition from hot surfaces. The temperature on the electronics/housing must not exceed the values specified in the above table. On the electronics, category 1G Temperature class T6-20 +51 C T5, T4, T3, T2, T1-20 +60 C On the electronics, category 1/2G or 2G Temperature class T6-40 +67 C T5-40 +82 C T4, T3, T2, T1-40 +90 C Permissible operating pressure in the area of the measuring probe Category 1G or 1/2G Under explosive atmosphere requiring instruments of category 1G: 0.8 1.1 bar Kategorie 2G Operating pressure Vacuum 64 bar (when applicable, take nominal pressure of the process connection element into account) Information: The application conditions mentioned before also apply to SWING63.C******N** with lock fitting ARV-SG63.2** (P max. 16 bar, T max. 150 C) and lock fitting ARV-SG63.3** (P max. 64 bar, T max. 250 C). Permissible differing application conditions The VEGASWING61/63.CX*****N/W** (also with lock fitting ARV-SG63.2/3**) can also be operated as category 1/2G instrument according to the conditions mentioned below. 7

Temperature class Temperature on the sensor Ambient temperature on the electronics Process pressure T4, T3, T2, T1-20 +60 C -40 +90 C 0 6 bar Note: If the abovementioned application conditions in the area of the sensor are different when using VEGASWING61/63.CX*****N/W** as category 1/2G instrument, please make sure that the sensor does not heat up (even in case of malfunctions). It is the responsibility of the plant operator to make sure the pressure/temperature of the processed materials presents no danger. The permissible pressures and temperatures for operation are mentioned in the operating instructions manuals. 5 Protection against static electricity The VEGASWING61/63.CX*****N/W** (also with lock fitting in versions ARV-SG63.2/3), with electrostatically chargeable plastic parts, such as e.g. plastic housing, metal housing with inspection window, with plastic coated sensors or distance tube, have a caution label pointing out the safety measures that must be taken with regard to electrostatic charges during operation. WARNING- POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS Caution: Plastic parts! Danger of electrostatic charging! Avoid friction No dry cleaning Construction/Installation: The VEGASWING61/63.CX*****N/W** must be constructed/installed in such a way that electrostatic charges are ruled out during operation, maintenance and cleaning. process-related electrostatic charges, e.g. by measuring media flowing past, are ruled out 6 Installation/construction The SWING63.C*******N/W** must be mounted in a way that adequately ensures that the sensor tube will not oscillate, vibrate or bend due to the movements of other installations or the medium in the vessel. 7 Impact and friction sparks The VEGASWING61/63.CX*****N/W** must be mounted in such a way that sparks from impact and friction between aluminium and steel (except stainless steel, if the presence of rust particles can be excluded) cannot occur. 8 Use of an overvoltage arrester If necessary, a suitable overvoltage arrester can be connected in front of the VEGASWING61/63. CX*****N/W**. When used as category 1G or 1/2G instrument, as far as necessary analogue, a suitable overvoltage arrester must be connected in front as protection against voltage surges according to EN 60079-14 chapter 12.3. 8

9 Material resistance The VEGASWING61/63.CX*****N/W** must only be used in media against which the materials of the wetted parts are sufficiently resistant. The min. fatigue strength of the vibrating element is 8.6 x 10 11 load changes with a max. amplitude of 7.5 µm. The lifetime is minimum 20 years. 10 Grounding The VEGASWING61/63.CX*****N/W** must be grounded electrostatically (transfer resistance 1 MΩ), e.g. via the internal or external ground terminal on the housing. The metallic parts of the VEGASWING61/63.CX*****N/W** are electrically connected with the internal or external ground terminal on the housing. 9

Notes 10

Notes 11

Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 2017 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com