CAMUS FAMILY HYDRONICS LTD.

Similar documents
CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Project Name: Location: Engineer: Contractor: I. GENERAL

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

FXLF-9. High Efficiency Water Heaters and Boilers

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Date: Project #: Engineer: Prepared By: Bid Date:

CONDENSING HIGH EFFICIENCY BOILERS

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

High Efficiency Commercial Gas Water Heaters

HIGH EFFICIENCY COMMERCIAL BOILERS

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Less Than.25% Lead Proudly Assembled in the U.S.A

CAMUS ADVANTUS BOILERS

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Less Than.25 Pb Proudly made in the U.S.A

Proudly assembled in U.S.A

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Proudly assembled in U.S.A

FINNED WATER-TUBE POOL HEATERS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DOM-5. Domestic Hot Water Heaters & Boilers

DIVISION FINNED WATER-TUBE BOILERS

Domestic Hot Water Heaters and Boilers FTIIIC-6

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Up to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY

DIVISION FINNED WATER-TUBE BOILERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

DIVISION FINNED WATER-TUBE BOILERS

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Less Than.25% Lead Proudly Assembled in the U.S.A

Triton Series High Efficiency Boiler

DIVISION FINNED WATER-TUBE BOILERS

Automatic Circulating Water Heaters

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Raypak Residential Products

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

HIGH EFFICIENCY COMMERCIAL BOILERS. Thermal Efficiency RIDE THE LOCHINVAR WAVE. Registered under U.S. Patent #9,746,176

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

FINNED WATER-TUBE POOL HEATERS

Boilers Variable Fire Boilers

FXLF-4. High Efficiency Water Heaters and Boilers

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

Proudly assembled in U.S.A

DIVISION FINNED WATER-TUBE WATER HEATERS

Tankless Condensing High Efficiency Water Heaters

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

Commercial Tankless Rack System

DIVISION FINNED WATER-TUBE WATER HEATERS

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

Suggested Specifications Prestige Excellence 110

Raptor 320HB & 399HB Submittal Sheet

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Commercial Tankless Rack System

Commercial Boilers and Domestic Water Heaters APG-5

Tankless Water Heaters

Residential/Commercial Gas Condensing Tankless Models

Residential Gas Tankless Water Heater

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Models HD101 thru 2342B

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Power Flame Incorporated

The Brute MagnaTech. A Perfect Balance of Size, Form, and Function. Commercial, High Efficiency Condensing Boiler and Volume Water Heater

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

WATER-TUBE POOL HEATERS

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Transcription:

FAMILY BROCHURE THE CAMUS FAMILY OF GAS FIRED RESIDENTIAL, COMMERCIAL AND INDUSTRIAL COPPER TUBE, STAINLESS STEEL AND FIRE TUBE BOILERS AND WATER HEATERS CAMUS HYDRONICS LTD. Rev.03

Camus Hydronics is taking a leading role in the development of environmentally friendly products through innovative engineering as we incorporate the very latest technologies designed to create higher efficiency levels while lowering emissions. Our high efficiency units either meet or surpass the standards of both the Canadian and US Green Building Councils. CAMUS is continually setting new benchmarks of excellence through skillfully engineered and solidly constructed high-efficiency products designed to provide years of reliable service and comfort. Additional specifications can be obtained by visiting our website or by calling your local CAMUS representative. www.camus-hydronics.com FORWARD

Table of Contents Advantus TM Dynaforce DynaFlame DynaMax TH Series DynaPac MicoFlame BlueFlame CeraFlame SureFlame Controls 1 3 5 7 8 9 10 13 14 15 16 Our Family Brochure has been designed to provide you with a convenient overview of the entire line of CAMUS Boilers and Water Heaters. For a full list of features and technical data including specifications on any of our products, please refer to the product brochure, your local CAMUS Representative, or by visiting www.camus-hydronics.com. Every CAMUS product is designed, tested and built to either meet or exceed the safety standards and fuel efficiency of each of these agencies. THINKING

ADVANTUS Fire Tube Commercial Boilers for Hydronic Heating and Hot Water Supply TM Camus Hydronics Ltd. is proud to introduce the industry s first two-pass counter-flow fire tube heat exchanger. With thermal efficiencies of up to 99% in low water temperatures and a turn down ratio of up to 25:1, the Advantus TM is aimed at providing you with outstanding energy saving capabilities paired with remarkable high efficiencies. With 13 models available with inputs ranging from 450,000 to 4.0 million btu/hr, the Camus Advantus TM is the one to choose. The Advantus TM is controlled by an integrated Honeywell SOLA controller. The 7 color touch screen provides remote operation through 4-20mA or 0-10Vdc for set point or fire rate control. Paired with the ability to control multiple pump operation along with daisy chain set up for up to 8 boilers (with add on capability to control up to 12 boilers), this user friendly control also provides you with a USB input for screenshot capture. 1 Inside the signature mirrored panels is the heat exchanger that separates Camus from the rest The Advantus TM features a two-pass counter-flow fire-tube heat exchanger with 1.5 diameter oval tubes configured to optimize performance and maximize heat transfer and efficiencies. Designed with a generous heating surface to sustain efficiencies across complete firing range, the Advantus TM impresses with flow rates ranging from as low as 6.6 GPM* to upwards of 380 GPM**. Constructed using 304L/316L grade stainless steel, this all welded heat exchanger has been designed with a unique counter flow design so that as flue products exit the boiler, they pass by the incoming water to achieve the highest possible heat transfer and latent heat capture. The burner is 100% stainless steel vertical mounted radial fired with stainless knitted metal fiber construction. The burner combusts a precise amount of premixed combustion air and gas to provide equal distribution of heat for heat transfer to the entire heat exchanger. Providing a turn down ratio of up to 25:1 all while sustaining combustion characteristics throughout the entire modulating range. *Advantus TM model 500 at minimum firing rate, 10 F T **Advantus TM model 4000 at maximum firing rate, 20 F T THERMAL EFFICIENCIES OF UP TO 99% TURNDOWN RATIO OF UP TO 25:1 FORWARD THINKING For ease of installation the fully condensing Advantus TM can be vented individually in a Category IV positive pressure venting arrangement or they can be vented in a common chimney resulting in a Category II venting system. With the outstanding efficiency of the Advantus TM it can be vented with corrosion resistant CPVC, Polypropylene, AL29-4C or 316L stainless steel material as stack temperatures are between 10-25 F (5.5 14 C) above incoming water temperatures. This allows a diverse range of venting materials to suit any installation and the Advantus TM is capable of venting up to 100 equivalent feet and up to 100 equivalent feet of combustion air can be brought directly to the boiler for direct vent installations. The Advantus TM is available with an air inlet damper for cold climates which prevents outdoor air from infiltrating the heat exchanger when the Advantus TM is in standby.

A P C B R M X (gas) G F H J I N V (vent) K W (water connections) FRONT VIEW SIDE VIEW BACK VIEW L (air inlet) D E Input and Output Air Inlet and Venting (Inches) Maximum Input MBTU/hr Maximum Output MBTU/hr 500 450 425 600 600 567 800 800 749 1000 1000 936 1200 1200 1123 1400 1400 1310 1600 1600 1498 1800 1800 1685 2000 2000 1900 2500 2500 2375 3000 3000 2850 3500 3500 3325 4000 4000 3800 Up to 100 ft. Equiv. Length Ø Dim. "V" Vent CAT. II Air Inlet Cat IV 500 5 5 6 600 5 5 6 800 6 6 6 1000 6 6 7 1200 6 7 8 1400 6 7 8 1600 8 7 9 1800 8 8 10 2000 8 8 10 2500 8 9 10 3000 10 10 10 3500 10 10 12 4000 10 10 14 Dimensions and Specifications (Inches) Dim. A Dim. B Dim. C Dim. D Dim. E Dim. F Dim. G Dim. H Dim. I Dim. J Dim. K Dim. L Dim. "M" Dim. "N" Dim. "P" Dim. "R" Up to 99% Thermal Efficiency Suitable for Category 2 and Category 4 Installation All welded heat exchanger, 304/316L stainless steel, counter flow, fire-tube construction Return water temperatures down to 40 F Single point input adjustment for control of air and gas 1 to 1 air/gas ratio control for perfect combustion across entire modulation range Extremely low NOx emissions (less than 9 ppm) Flow Switch Water pressure Switch Local/Remote switch for building management, remote modulation and set-point control Extremely low noise level Stainless steel mirror finish outer jacket Advanced integrated Honeywell SOLA control with touch-screen interface Direct ignition up to 2.5 million BTU/hr. Proven pilot ignition for 3 to 4 million BTU/hr. Low gas pressure switch High gas pressure switch (models 3000-4000) Stainless steel metal fiber burner Easy access to components for maximum serviceability Maximum allowable working pressure of 160psig Maximum allowable discharge temperature of 210 F for Heating, 210 F for DHW Minimum gas pressure requirements of 4.0 w.c. Main burner test firing valve For operation with natural gas or propane Flame failure alarm contacts Up to 25:1 turndown for seamless operation Boiler modulates to shut down on flue gas high temperature detection Suitable for venting with Stainless Steel, CPVC or PPE plastic vent material (app. dependent) Cascade up to 8 individual appliances in daisy-chain formation UV Flame detection Staging relay to govern operation of low end or high end gas valve (models 800-4000) Electronic air proving switch Heat Exchanger Head Loss and Flow 10 o F Rise 20 o F Rise 40 o F Rise 60 o F Rise (Minimum Input) (Maximum Input) (Maximum Input) (Maximum Input) US GPM P-Ft. US GPM P-Ft. US GPM P-Ft. US GPM P-Ft. 500 N/A N/A 47.20 1.80 23.60 0.50 15.70 0.20 600 N/A N/A 56.60 2.60 28.30 0.60 18.90 0.30 800 6.60 0.03 74.80 4.50 37.40 1.10 24.90 0.50 1000 8.20 0.05 93.40 7.00 46.70 1.80 31.20 0.80 1200 9.90 0.02 112.20 2.00 56.10 0.50 37.40 0.20 1400 11.50 0.02 130.80 2.70 65.40 0.70 43.60 0.30 1600 13.20 0.03 149.60 3.90 74.80 0.80 49.90 0.40 1800 14.80 0.04 168.20 4.40 84.10 1.20 56.10 0.50 2000 16.50 0.05 189.80 5.60 94.90 1.40 63.20 0.60 2500 20.60 0.07 237.20 8.80 118.60 2.20 79.10 1.00 3000 24.70 0.01 284.60 1.60 142.30 0.40 95.00 0.20 3500 28.90 0.02 332.00 2.20 166.00 0.60 110.70 0.30 4000 33.00 0.02 379.40 2.90 189.70 0.70 126.50 0.30 Optional Features Dim. "V" Ø Dim. "W" (as shipped) Water 500 29½" 34" 60" 39½" 50" 37" 50" 4" 21½" 15" 6" 6" 19 1/8" 9½" 22½" 37½" 5" 2" 1" 600 29½" 34" 60" 39½" 50" 37" 50" 4" 21½" 15" 6" 6" 19 1/8" 9½" 22½" 37½" 5" 2" 1" 800 30" 34" 83" 61" 74" 59½" 68½" 4" 21½" 15½" 6" 8" 19" 9" 22" 37½" 6" 2" 1" 1000 30" 34" 83" 61" 74" 59½" 68½" 4" 21½" 15½" 6" 8" 19" 9" 22" 37½" 6" 2" 1" 1200 30" 42" 83" 59" 75" 57" 67" 4" 21½" 15½" 6" 10" 19" 7½" 22" 45½" 7" 2½" 1" 1400 30" 42" 83" 59" 75" 57" 67" 4" 21½" 15½" 6" 10" 19" 7½" 22" 45½" 7" 2½" 1¼" 1600 30" 42" 83" 54½" 75" 51" 63" 4" 21½" 16½" 6" 10" 23" 7½" 22" 45½" 8" 3" 1¼" 1800 30" 42" 83" 54½" 75" 51" 63" 4" 21½" 16½" 6" 10" 23" 7½" 22" 45½" 8" 3" 1¼" 2000 30" 42" 93" 63½" 80" 60" 72" 4" 22" 16½" 6" 12" 23" 7½" 22" 45½" 9" 3" 1¼" 2500 30" 42" 93" 63½" 80" 60" 72" 4" 22" 16½" 6" 12" 23" 7½" 22" 45½" 9" 3" 1½" 3000 35" 47" 101" 66" 90" 62" 78" 5½" 26" 5½" 24" 12" 23" 17½" 27½" 50" 10" 3" 1½" 3500 35" 47" 101" 66" 90" 62" 78" 5½" 26" 5½" 24" 12" 23" 17½" 27½" 50" 10" 4" 2" 4000 35" 47" 101" 66" 90" 62" 78" 5½" 26" 5½" 24" 12" 23" 17½" 27½" 50" 10" 4" 2½"* (2"**) Ø Dim. "X" Gas Pump delay up to 1hp/Pilot duty over 1hp Air inlet damper and/or damper contacts Low water cut off (manual or automatic reset) High gas pressure switch (standard on models 3000-4000) Status on/off monitoring contacts Gateway protocol converter for Bacnet, Metasys N2, LonWorks Neutralization kit for condensate water Remote operation for set-point or fire-rate control utilizing 0-10Vdc Optional Power: 460/3/60, 208/1/60, 208/3/60 *Natural Gas / **Propane 2

DYNAFORCE Gas Fired Stainless Steel Condensing Boilers for Hydronic Heating and Hot Water Supply The Dynaforce is controlled by an integrated Honeywell SOLA controller. The 7 color touch screen provides remote operation through 4-20mA or 0-10Vdc for set point or fire rate control. Paired with the ability to control multiple pump operation along with daisy chain set up for up to 8 boilers (with add on capability to control up to 12 boilers), this user friendly control also provides you with a USB input for screenshot capture. EFFICIENCIES OF UP TO99% 3 The Dynaforce Heat Exchanger is a vertical cylindrical counter-flow water tube design. Constructed of 439 grade stainless steel, this welded heat exchanger features a 12 pass design with a maximum working pressure of 160 psig (1100 kpa) and a vertical cylindrical counter-flow water tube design complete with integral 439 grade stainless steel finned heat transfer tubes and waterways. The heat exchanger design is capable of 40 F constant system return temperatures for fully condensing operation and comes complete with condensate trap and drains. TURNDOWN RATIO OF UP TO 5:1 The burner is 100% stainless steel and vertical mounted radial fired with stainless knitted metal fiber construction. The burner combusts a precise amount of premixed combustion air and gas to provide equal distribution of heat for heat transfer to the entire heat exchanger. Combustion operates with a 5:1 turn down ratio while sustaining combustion characteristics throughout the entire modulating range For ease of installation, the fully condensing Dynaforce can be vented individually in a Category IV positive pressure venting arrangement or they can be vented in a common chimney resulting in a Category II venting system. Outdoor Venting Standard Venting Sidewall Venting and combustion air inlet With the outstanding efficiency of the Dynaforce it can be vented with corrosion resistant PVC, CPVC, Polypropylene, AL29-4C or 316L stainless steel material as stack temperatures are between 10-15 F above incoming water temperatures. This allows a diverse range of venting materials to suit any installation and the Dynaforce is capable of venting up to 100 equivalent feet and up to 100 equivalent feet of combustion air can be brought directly to the boiler for direct vent installations. The Dynaforce is available with an air inlet damper for cold climates which prevents outdoor air from infiltrating the heat exchanger when the Dynaforce is in standby.

A B M H I L (air inlet) Maximum Input MBTU/hr Maximum Output MBTU/hr X (gas) 300 300 282 350 350 329 400 399 375 500 500 470 600 600 564 800 800 752 1000 1000 940 1200 1200 1138 1400 1400 1327 1600 1600 1517 1800 1800 1706 2000 2000 1896 2500 2500 2370 3000 3000 2835 3500 3500 3307 4000 4000 3780 4500 4500 4253 5000 4999 4724 Input and Output C G F J W (water connections) V (vent) junction box K D E FRONT VIEW SIDE VIEW BACK VIEW Dimensions and Specifications (Inches) Dim. "A" Dim. "B" Dim. "C" Dim. "D" Dim. "E" Dim. "F" Dim. "G" Dim. "H" Dim. "I" Dim. "J" Dim. "K" Ø Dim. "L" Air Inlet* Ø Air Inlet up to 100 Ft. Equiv. Length Ø Dim. "V" Vent CAT. IV up to 100 Ft. Equiv. Length* Ø Dim. Dim. "V" Vent "M" CAT. II 300 25 27 42 15 1/2 34 7/8 9 3/4 31 1/4 6 3/4 4 3/4 11 7/8 6 6 4 4 4 5 1 1/2 3/4 380 350 25 27 42 15 1/2 34 7/8 9 3/4 31 1/4 6 3/4 4 3/4 11 7/8 6 6 4 4 5 5 1 1/2 3/4 380 400 25 27 48 3/4 16 3/8 41 7/8 10 1/2 39 3/4 9 3/4 3 3/4 12 6 6 5 4 5 5 1 1/2 1 430 500 25 27 48 3/4 16 3/8 41 7/8 10 1/2 39 3/4 9 3/4 3 3/4 12 6 6 5 5 5 5 1 1/2 1 430 600 25 27 55 1/4 18 1/2 46 11 1/2 45 7/8 10 1/2 4 5/8 12 6 8 6 5 6 5 2 1 480 800 25 27 55 1/4 18 1/2 46 11 1/2 45 7/8 10 1/2 4 5/8 12 6 8 6 6 6 5 2 1 480 1000 25 27 65 20 3/4 57 13 56 5/8 10 3/8 4 3/8 12 6 8 8 6 7 5 2 1 580 1200 29 3/8 31 3/4 70 1/2 20 3/4 59 1/2 13 56 3/8 1 7/8 23 1/4 12 6 10 8 7 8 5 2 1/2 1 1/4 620 1400 29 3/8 31 3/4 73 1/2 22 5/8 62 1/2 14 59 1/4 1 7/8 23 1/4 12 6 10 8 7 8 5 2 1/2 1 1/4 700 1600 29 3/8 31 3/4 73 1/2 22 5/8 62 1/2 14 59 1/4 1 7/8 23 12 6 12 10 7 9 5 2 1/2 1 1/4 880 1800 29 3/8 31 3/4 73 1/2 22 5/8 62 1/2 14 59 1/4 1 7/8 23 12 6 12 10 8 9 5 2 1/2 1 1/4 880 2000 29 3/8 31 3/4 81 1/4 24 5/8 72 3/8 14 3/8 69 1 7/8 22 3/4 12 1/2 6 1/2 12 10 8 10 5 3 1 1/4 910 2500 29 3/8 31 3/4 82 5/8 25 74 15 3/4 69 1/2 1 7/8 22 1/2 11 1/4 6 1/2 12 12 9 10 5 1/2 3 1 1/2 1000 3000 35 3/4 39 1/4 85 1/4 25 5/16 75 3/16 16 70 1/2 1 7/8 27 3/4 14 7 3/4 12 12 9 10 5 1/2 3 1 1/2 1350 3500 35 3/4 39 1/4 93 27 1/4 82 1/4 15 1/2 76 1/4 4 1/2 27 3/4 12 12 12 12 10 12 7 4 2 1500 4000 35 3/4 39 1/4 93 25 1/4 82 1/4 15 1/2 76 1/4 4 1/2 27 3/4 12 12 12 12 10 12 7 4 2 1500 4500 35 3/4 39 1/4 96 29 81 1/4 16 1/2 79 1/4 4 1/2 28 12 12 14 14 12 12 7 1/2 4 2 1/2 1650 5000 35 3/4 39 1/4 102 29 1/2 87 1/2 16 3/4 85 1/2 4 1/2 27 3/4 12 12 14 14 12 12 8 4 2 1/2 1750 Ø Dim. "W" Water Ø Dim. "X" Gas Shipping Weight (lbs) *As shipped 4 18 models available with inputs ranging from 300,000 btu/hr to 5 Mil btu/hr Up to 99% Thermal Efficiency Suitable for Category 2 and Category 4 installation All welded heat exchanger, 316L/439 grade stainless steel counter flow, primary/secondary construction Return water temperatures down to 40 F Single point input adjustment for control of air and gas 1 to 1 air/gas ratio control for perfect combustion across entire modulation range Extremely low NOx emissions (less than 9 ppm) Flow Switch Water pressure switch Local/Remote switch for building management, remote modulation and set-point control Extremely low noise level Stainless steel mirror finish outer jacket Advanced integrated Honeywell SOLA control with touch-screen interface Suitable for venting with PVC, CPVC or PPE plastic vent material (app. dependent) Cascade up to 8 individual appliances in daisy-chain formation Direct ignition up to 2.5 million BTU/hr. Proven pilot ignition for 3 to 5 million BTU/hr. Low gas pressure switch High Gas pressure switch (models 3000 through 5000) Inlet regulator for incoming gas pressures up to 14 w.c. Stainless steel burner with radial knitted fiber Easy access to components for maximum serviceability Maximum allowable working pressure of 160 psig Maximum allowable discharge temperature of 210 F Minimum gas pressure requirements of 4.5 w.c. for models 300-1000, 7 w.c. for models 1200-5000 Main burner test firing valve For operation with natural gas or propane Flame failure alarm contacts 5:1 turndown ratio with a minimum 20% firing rate Flue temperature monitoring Optional Features Dual Fuel for firing with natural and propane (incl. two gas trains) Pump delay up to 1hp/Pilot duty over 1hp Air inlet damper and/or damper contacts Low water cut off (manual or automatic reset) High gas pressure switch (standard on models 3000-5000) Status on/off monitoring contacts Gateway protocol converter for BACnet, Metasys N2, IP or LonWorks Neutralization kit for condensate water Remote operation for set-point or fire-rate control utilizing 0-10VDC Additional Voltages

DYNAFLAME Gas Fired Commercial Copper Tube and Stainless Steel Boilers for Hydronic Heating and Hot Water Supply 5 copper... The copper heat exchanger is a four pass design with a maximum working pressure of 160 PSIG and a maximum working temperature of 250 F for heating and 210 F for domestic hot water applications. With its cast bronze headers and copper or cu-ni tubes, this gasket-less sealed design is a Camus trademark. Both the Copper and Stainless Heat Exchangers are vertically oriented which makes it easy to install and service with full access from the top and front of the appliance. Line up multiple units with minimal clearance between appliances. The burner is 100% stainless steel and vertical mounted radial fired with stainless knitted metal fiber construction. The burner combusts a precise amount of premixed combustion air and gas to provide equal distribution of heat for heat transfer to the entire heat exchanger. Combustion operates with up to a 5:1 turn down ratio while sustaining combustion characteristics throughout the entire modulating range...or stainless The stainless steel heat exchanger is a six pass design with a maximum working pressure of 160 PSIG and is limited to 210 F maximum outlet temperature for heating and domestic hot water applications. It is a welded 439 grade stainless steel construction with a vertical cylindrical water tube design, complete with integral 439 stainless finned heat transfer tubes and 304/316L waterways. boiler efficiencies 85% non-condensing 88% near-condensing 95% condensing The DynaFlame is controlled by an integrated Honeywell SOLA controller. The 7 color touch screen provides remote operation through the 4-20mA or 0-10Vdc for set point or fire rate control. Paired with the ability to control multiple pump operation along with daisy chain set up for up to 8 boilers, this user friendly control also provides you with a USB output for screenshot capture, as well as password access for service personnel. Up to 8 SOLA devices may be monitored and controlled with one single display. Single point input adjustment for controlling air and gas 1 to 1 air/gas ratio for perfect modulation throughout Extremely low NOx emissions (less than 10 PPM) Flow switch Pressure relief valve Very small footprint Extremely low noise level Stainless steel outer jacket & combustion chamber Advanced digital control system with pin point accuracy Proven hot surface ignition with soft start, rumble free operation Low gas pressure switch 4-20mA for setpoint or modulation control Local remote switch Proven pilot ignition 3 to 6 million 0-10 VDC Converter (must be specified) Lead lag capability up to 8 boilers standard DHW sensor (Domestic only) and system sensor (Htg only) Modbus RTU Communication Flame failure contacts Direct Ignition up to 2.5 million BTU/hr Condensing Additional Features 95% Thermal Efficiency Suitable for Category 2 and Category 4 installation Range of burner modulation 20-100% (turn down ratio 5:1 Non-Condensing Additional Features 85% Thermal Efficiency Suitable for Category 1 and Category 3 installation Range of burner modulation 35-100% (turn down ratio 3:1) Near-Condensing Additional Features 88% Thermal Efficiency Suitable for Category 2 and Category 4 installation Range of burner modulation 20-100% (turn down ratio 5:1)

A B P primary water connections K L M N E C I G D H F optional condensing models only FRONT VIEW SIDE VIEW BACK VIEW (condensing) J BACK VIEW (non-condensing) NOTE: For Non-Condensing Heating or Domestic Hot Water Boilers, replace X with 1. For Condensing Heating or Domestic Hot Water Boilers, replace X with 2. For Near-Condensing Heating or Domestic Hot Water Boilers, replace X with 3 Dimensions & Specifications (Inches) Air Inlet Water Water Conn. Width "A" Depth "B" Height "C" Water Flue Gas Height Dia. As Conn. Prim. Prim. (s/s) as Water Conn. Gas Conn. Air Inlet "E" "H" "I" "J" "K" "L" "M" "N" "P" Conn. "D" Height "F" "G" shipped (copper) as shipped Sec. as shipped (NPT) "W" shipped (Grooved) 050X 25 27 45 5/8 27 37 1/4 13 1/4 33 5/8 17 3/4 6 4 1/8 2 5/8 11 1/2 18 3/4 6 1/4 5 10 2 NPT 2 1 1/2 Grooved 1 075X 25 27 55 36 3/4 46 5/8 15 3/4 43 25 6 4 1/8 2 5/8 11 1/2 18 3/4 6 1/4 5 10 2 NPT 2 1 1/2 Grooved 1 110X 25 27 68 1/4 49 5/8 59 7/8 22 56 1/4 31 1/8 6 4 1/8 2 5/8 11 1/2 18 3/4 6 1/4 5 10 2 NPT 2 1 1/2 Grooved 1 120X 25 27 68 1/4 49 5/8 59 7/8 22 56 1/4 31 1/8 6 4 1/8 2 5/8 11 1/2 18 3/4 6 1/4 5 10 2 NPT 2 1 1/2 Grooved 1 150X 29 3/8 31 3/4 58 1/8 38 1/4 48 5/8 16 3/8 45 7/8 24 1/2 6 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 5 10 3 NPT 2 1/2 1 1/2 Grooved 1 1/4 175X 29 3/8 31 3/4 62 5/8 42 5/8 53 1/8 16 3/8 50 3/8 24 1/2 6 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 5 10 3 NPT 2 1/2 1 1/2 Grooved 1 1/4 200X 29 3/8 31 3/4 66 7/8 46 7/8 57 3/8 20 53 5/8 28 3/4 6 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 5 12 3 NPT 3 1 1/2 Grooved 1 1/4 250X 29 3/8 31 3/4 73 1/2 52 5/8 63 5/8 25 3/4 60 3/8 34 1/2 6 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 5 1/2 12 3 NPT 3 1 1/2 Grooved 1 1/2 300X 29 3/8 31 3/4 79 1/2 58 5/8 69 5/8 31 3/4 66 3/8 40 1/2 6 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 5 1/2 12 3 NPT 3 1 1/2 Grooved 1 1/2 350X 29 3/8 31 3/4 86 1/2 63 5/8 76 24 7/8 72 5/8 32 7/8 20 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 6 14 3 NPT 3 1 1/2 Grooved 2 400X 29 3/8 31 3/4 91 1/2 68 5/8 81 29 7/8 77 5/8 37 7/8 20 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 6 14 3 NPT 3 1 1/2 Grooved 2 450X 29 3/8 31 3/4 96 1/2 73 5/8 86 34 7/8 82 5/8 42 7/8 20 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 31 14 3 NPT 3 1 1/2 Grooved 2 1/2 500X 29 3/8 31 3/4 101 1/2 78 5/8 91 39 7/8 87 5/8 47 7/8 20 3 7/8 1 7/8 13 1/2 22 3/8 10 1/4 31 14 3 NPT 3 1 1/2 Grooved 2 1/2 45X4 35 3/4 39 1/4 83 59 3/4 72 1/4 20 3/4 67 7/8 28 7/8 20 2 1/2 3 1/2 17 7/8 25 5/8 12 31 14 4 Grooved 4 1 1/2 Grooved 2 1/2 50X4 35 3/4 39 1/4 88 1/4 65 77 1/2 26 72 1/4 34 1/8 20 2 1/2 3 1/2 17 7/8 25 5/8 12 31 14 4 Grooved 4 1 1/2 Grooved 2 1/2 60X4 35 3/4 39 1/4 102 75 1/2 91 35 1/2 85 1/2 44 5/8 20 2 1/2 2 3/4 17 7/8 25 5/8 12 31 14 4 Grooved 4 1 1/2 Grooved 3 6 Venting (Inches) Outdoor Non-Condensing Cat. III Up to 50 ft. Cat. III Up to 100 ft. Cat. I Condensing & Near-Condensing Outdoor Cat. IV Up Cat. IV Up to 50 ft. to 100 ft. Cat. II 050X 4 4 6 8 4 4 6 5 075X 6 6 8 10 6 6 8 6 110X 6 6 8 10 6 6 8 7 120X 6 6 8 10 6 6 8 7 150X 7 7 10 12 7 7 10 8 175X 7 7 10 12 7 7 10 8 200X 8 8 12 14 8 8 12 9 250X 8 8 12 14 8 8 12 9 300X 8 8 12 14 8 8 12 10 350X 9 9 14 16 9 9 14 12 400X 9 9 14 16 9 9 14 12 450X 10 10 14 16 10 10 14 12 500X 10 10 14 16 10 10 14 12 45X4 10 10 14 16 10 10 14 12 50X4 10 10 14 16 10 10 14 12 60X4 12 12 14 16 12 12 14 12 Input and Output Maximum Input MBTU/hr Maximum Output MBTU/hr (Non-Condensing) Maximum Output MBTU/hr (Near-Condensing) Maximum Output MBTU/hr (Condensing) 050X 500 425 440 475 075X 750 638 660 713 110X 1100 935 968 1045 120X 1200 1020 1056 1140 150X 1500 1275 1320 1425 175X 1750 1488 1540 1663 200X 2000 1700 1760 1900 250X 2500 2125 2200 2375 300X 3000 2550 2640 2850 350X 3500 2975 3080 3325 400X 4000 3400 3520 3800 450X 4500 3825 3960 4275 500X 4999 4249 4399 4749 45X4 4500 3825 3960 4275 50X4 4999 4249 4399 4749 60X4 6000 5100 5280 5700 Approx. Shipping Weights - LBS Non- Cond. Near- Cond. Cond. 050X 520 520 593 075X 600 600 678 110X 640 640 704 120X 700 700 770 150X 825 825 899 175X 900 900 963 200X 943 943 999 250X 1025 1025 1085 300X 1100 1100 1120 350X 1250 1250 1330 400X 1290 1290 1380 450X 1420 1420 1500 500X 1627 1627 1720 45X4 1525 1525 1610 50X4 1732 1732 1815 60X4 1963 1963 2210

DYNAMAX Gas Fired Residential & Commercial Condensing Boilers for Hydronic Heating, Hot Water Supply and Combination EFFICIENCIES UP TO 97% The DynaMax is equipped with a multi-line user configurable LCD display which provides access to control system configuration and set up, readouts of various heater temperatures, accumulated runtime, enunciator diagnostics, flame signal readout and firing rates. The display shall be accessed through a 5-way touchpad high resolution LCD control with shortcut key access with user and installer protected parameters. The display is capable of storing up to 15 automatic reset errors and 15 manual reset errors. 7 All stainless steel water surfaces Gasketless heat exchanger design Up to 97% efficiency Approved plastic venting up to 100 feet (PVC, PVC, PPE) Up to 150 PSI Relief valves Onboard digital operating control Fully modulating with 5:1 turndown Available in Natural Gas or LP Thru wall exhaust vent (vertical or horizontal) with 3 air intake options: 1) outside air sealed direct, 2) outside air, 3) Indoor air UL353 approved fail safe high limit @ 210 F with manual reset Factory mounted boiler circulating pump Single point input adjustment for air and gas 1 to 1 air/gas ratio for perfect modulation throughout Extremely low NOx emissions exceeding air quality standards (<10ppm) Cascade up to 8 individual appliances in daisy-chain formation...and more! Wall Mount Input and Output Floor Mount Maximum Input MBTU/hr Maximum Output MBTU/hr 008X 80 74.4 010X 100 93.0 015X 150 139.5 020X 200 186.0 025X 250 232.5 021X 199 186.0 026X 250 232.5 029X 299 278.0 039X 399 371.0 050X 500 465.0 060X 600 558.0 070X 700 651.0 080X 800 744.0 Dimensions and Specifications (Inches) Floor Mount Wall Mount Dimensions and Specifications - Wall Mount Equivalent Length of Vent & Air Intake Pipes at Water Gas Dim. A Dim. B Dim. C Dim. D Dim. E Dim. F Dim. J Category IV CAT.II Conn. at Conn. at Over 25' and up Over 15' and Up to 15' Comb. Heater Boiler 008X 16 1/2 12 - - - - - 3 3 2-1 1/2 010X 16 1/2 12 - - - - - 3 3 2-1 1/2 015X 16 1/2 12 - - - - - 3 3 2-1 1/2 020X 23 1/2 19 - - - - - 3 3 2-1 1/2 025X 23 1/2 19 - - - - - 3 3 2-1 1/4 1/2 021X 42 1/2 25 3/4 14 1/4 23 24 1/4 34 1/4 32 3 3 2 4 1 1/2 026X 42 1/2 25 3/4 14 1/4 23 24 1/4 34 1/4 32 3 3 2 4 1 1/4 1/2 029X 47 1/8 34 7/8 14 23 29 7/8 33 7/8 32 4 3 3 5 1 1/4 3/4 039X 47 1/8 34 7/8 14 23 29 7/8 33 7/8 32 4 3 3 5 1 1/2 1 050X 47 1/8 34 7/8 14 23 29 7/8 33 7/8 32 4 3 3 6 1 1/2 1 060X 47 1/8 36 1/4 14 23 30 3/4 38 40 1/2 4 3 3 6 2 1 070X 47 1/8 36 1/4 14 23 30 3/4 38 40 1/2 4 (Air), 6 (Vent) 4 4 7 2 1 080X 47 1/8 36 1/4 14 23 30 3/4 38 40 1/2 5 (Air), 6 (Vent) 5 5 7 2 1 Dimensions and Specifications - Floor Mount Shipping Weight (HTG) Shipping Weight (DHW) Shipping Weight (Combi) Approx. Shipping Weights Wall Mount Floor Mount 008X 135 135 140 010X 135 135 190 015X 190 190 198 020X 210 210 220 025X 220 220 230 021X 315 315 320 026X 320 320 335 029X 376 376 380 039X 405 405 445 050X 450 470 514 060X 490 610 650 070X 533 615 660 080X 600 630 675 DynaMax HS Wall Mount s: 008X, 010X, 015X, 020X, 025X DynaMax HS Floor Mount s: 021X, 026X, 029X, 039X, 050X, 060X, 070X, 080X NOTE: For Hydronic Heating Boilers, replace X with 1 For Domestic Hot Water Boilers, replace X with 2 For Combination Htg./DHW Boilers, replace X with 3

TH SERIES Gas Fired Commercial Condensing Water Heater for Hydronic Heating & Hot Water Supply EFFICIENCIES UP TO97% Input and Output Maximum Input MBTU/hr Maximum Output MBTU/hr TH-082 80 74.4 TH-102 100 93.0 TH-152 150 139.5 TH-202 200 186.0 TH-252 250 232.5 TH-292 299 278.0 TH-392 399 371.0 TH-502 500 465.0 Approx. Shipping Weights - LBS Approx. Shipping Weight TH-082 121 TH-102 125 TH-152 158 TH-202 192 TH-252 192 TH-292 340 TH-392 386 TH-502 405 Tank Capacity (US Gal.) Tank Capacity TH-082 20 TH-102 20 TH-152 20 TH-202 40 TH-252 40 TH-292 40 TH-392 40 TH-502 40 Dim. and Specifications (Inches) Dim. A Dim. B Dim. C Dim. D 24 3/8 B A Dim. E Dim. F Dim. G Dim. H E D C 32 5/8 over 25' & up to 100' combustion air gas Length of Vent & Air Intake Pipes at Recommended Dia. vent water out Category IV over 15' & up to 25' TH-082 53 22 1/4 46 1/4 46 3/8 47 1/2 8 3/4 9 7/8 7 3/8 3 3 2-1 1/2 TH-102 53 22 1/4 46 1/4 46 3/8 47 1/2 8 3/4 9 7/8 7 3/8 3 3 2-1 1/2 TH-152 53 22 1/4 46 1/4 46 3/8 47 1/2 8 3/4 9 7/8 7 3/8 3 3 2-1 1/2 TH-202 53 31 1/4 37 3/4 46 3/8 47 1/2 12 1/8 9 7/8 7 3/8 3 3 2 4 1 1/2 TH-252 53 31 1/4 37 3/4 46 3/8 47 1/2 12 1/8 9 7/8 7 3/8 3 3 2 4 1 1/4 1/2 TH-292 65 1/2 31 1/4 37 1/2 58 3/8 53 7/8 12 1/8 11 3/8 8 7/8 4 3 3 5 1 1/4 3/4 TH-392 65 1/2 31 1/4 37 1/2 58 3/8 53 7/8 12 1/8 11 3/8 8 7/8 4 3 3 5 1 1/2 1 TH-502 65 1/2 31 1/4 37 1/2 58 3/8 53 7/8 12 1/8 11 3/8 8 7/8 4 3 3 6 1 1/2 1 G H water in 12 1/8 4 1/8 Up to 15' Cat. II Comb. Vent Water Conn. At Heater NPT Gas Conn. At Heater NPT The TH is equipped with a multi-line user configurable LCD display which provides access to control system configuration and set up, readouts of various heater temperatures, accumulated runtime, enunciator diagnostics, flame signal readout and firing rates. The display shall be accessed through a 5-way touchpad high resolution LCD control with shortcut key access with user and installer protected parameters. The display is capable of storing up to 15 automatic reset errors and 15 manual reset errors. 8 24 3/8 tank drain 8 3/8 3 3/8 condensate drain F FRONT VIEW SIDE VIEW BACK VIEW Up to 97% efficiency Approved for plastic venting up to 100 feet 150 PSI temp. & pressure relief valve Onboard integrated digital operating control Fully modulating with 5:1 turndown Stainless steel heat exchanger rated at 160 PSIG maximum allowed working pressure & 210 F maximum outlet temp. Available in Natural Gas or LP Thru wall exhaust vent (vertical or horizontal) with 3 air intake options: 1) outside air sealed direct, 2) outside air, 3) indoor air Extremely low NOx Fail safe high limit w/ manual reset Water flow proving Direct spark ignition Zero clearance to combustibles Factory mounted bronze circulating pump CSA Certified stainless steel storage tank w/ 10 year warranty, rated 160 PSIG maximum allowed working pressure & 210 F maximum working temp. Neutralizer kit

DYNAPAC For Residential Application EFFICIENCIES UP TO 97% Delivers instantaneous domestic hot water with brazed plate heat exchanger Household never runs out of hot water* Fan coil for space heating Rack mounted and pre-piped Connection ready for water, gas, power and operator connections Cooling has S.E.E.R. rating of 13 *Heater is to be sized for maximum load conditions Options Cooling coil up to 3 tons capacity available for chilled water or refrigerant Heating coil capacity of up to 88,597 BTU/hr Low profile mounting rack for reduced overhead clearance The DynaPac is a dynamic package combining all the advantages of the DynaMax HS heating models 083, 103, 153, 203 and 253 with versatile fan coil units which can be used for space heating and cooling. The DynaPac is equipped with a multi-line user configurable LCD display which provides access to control system configuration and set up, readouts of various heater temperatures, accumulated runtime, enunciator diagnostics, flame signal readout and firing rates. The display shall be accessed through a 5-way touchpad high resolution LCD control with shortcut key access with user and installer protected parameters. The display is capable of storing up to 15 automatic reset errors and 15 manual reset errors. 9 Dimensions - Low Profile Dimensions - High Profile A B C AH34-18 25.5" 67" 7.25" AH40-24 29.5" 71" 7.25" AH47-30 29.5" 71" 7.25" AH55-36 29.5" 71" 7.25" A B C AH34-18 25.5" 72" 12.25" AH40-24 29.5" 76" 12.25" AH47-30 29.5" 76" 12.25" AH55-36 29.5" 76" 12.25" Approx. Shipping Weight Approx. Shipping Weight Heating Only Heating & Cooling 153 lbs 171 lbs 160 lbs 178 lbs 160 lbs 178 lbs 163 lbs 181 lbs Heating Only Heating & Cooling 157 lbs 175 lbs 164 lbs 182 lbs 164 lbs 182 lbs 167 lbs 185 lbs Heater * Maximum Input Btu/hr Recovery - GPH at 100 F Rise with Plate Heat Exchanger (optional) 0083 0103 0153 0203 0253 80,000 85.3 100,000 106.6 150,000 160.0 200,000 213.3 250,000 266.6 Fan Coil Heating Capacities (Btu/hr) Heater * 4 GPM @ 180 F AH34-18 AH40-24 AH47-30 AH55-56 0083 56,631 66,565 71,200 71,200 0103 56,631 66,565 71,200 88,597 0153 56,631 66,565 71,200 88,597 0203 56,631 66,565 71,200 88,597 0253 56,631 66,565 71,200 88,597 Cooling Capacity (Btu/hr)** with 13 SEER Rating Coils Heater * AHCC-18 AHCC-24 AHCC-30 AHCC-36 0083 18,000 24,000 30,000 36,000 0103 18,000 24,000 30,000 36,000 0153 18,000 24,000 30,000 36,000 0203 18,000 24,000 30,000 36,000 0253 18,000 24,000 30,000 36,000 *Heater : 1) Available with plate exchanger for instantaneous DHW heating. 2) Choose recovery rate required. Choose cooling capacity required. Available heating capacity will be found under the column corresponding to the cooling capacity directly across from the heater model corresponding to the required recovery capacity. Example: Required 150 GPH recovery and 2 tons of cooling requires cooling coil AHCC-24. Under column AH40-24 find 65,565 Btu/hr heating capacity, across from model 0153 corresponding to a recovery capacity of 160 GPH. 4) Specify model DM (N,P) C 0153, AH40-24, AHCC-24 **12,000 Btu/hr = 1 Ton of cooling

MICOFLAME SERIES 1 Gas Fired Residential/Light Commercial Copper Tube Boiler for Hydronic Heating & Hot Water Supply EFFICIENCIES UP TO95% Note: X=0 (Non-Condensing), X=2 (Condensing) 006X 60,000 51,000 57,000 17.6 14.9 16.7 010X 100,000 85,000 95,000 29.3 24.9 27.8 015X 150,000 127,500 142,500 43.9 37.3 41.7 020X 200,000 170,000 190,000 58.6 49.8 55.6 025X 250,000 212,500 237,500 73.2 62.2 69.5 030X 299,000 254,150 284,050 87.6 74.4 83.2 040X 399,000 340,000 380,000 116.8 99.6 111.3 050X 500,000 425,000 475,000 146.4 124.5 139.1 060X 600,000 510,000 570,000 175.7 149.3 166.9 Dimensions and Specifications - s 60-300 Input and Output Input Output - BTUH (Non- Cond.) Output - BTUH (Cond.) Input - KW Output - KW (Non- Cond.) Output - KW (Cond.) Approx. Shipping Weights (lbs) Non- Condensing Condensing 006X 190 230 010X 195 235 015X 200 240 020X 210 250 025X 225 285 030X 240 290 040X 290 310 050X 305 345 060X 360 400 Low NOx Up to 85% efficiency Non Condensing mode Up to 95% efficiency Condensing mode Copper Tube Heat Exchanger which meets lead-free regulations Durable metal fiber burner unaffected by high temps Vents up to 50 feet horizontally with 50 feet of air intake duct Suitable for use in negative pressure environments Complete diagnostic light package Easy access for inspection & cleaning of heat exchanger tubes Durable ceramic fibre refractory Simple to service with easy access to burner and fan Outdoor Sensor complete with SmartFlame (Staging s 60-300 HTG applications only) 10 Side View (Left) Front View Side View (Right) Side View (Right) (Cond.) Dimensions and Specifications - s 400-600 Smartflame* 780007 Control Panel Highlights Dimensions & Specifications (inches) Side View (Left) Front View Side View (Right) Side View (Right) (Cond.) 'W' Water Connection (NPT) Gas Connection Outdoor 'B' Dia. Venting Sidewall or Condensing Standard 006X 18 3/4 1 1/2 1/2 3 3 3 3 010X 18 3/4 1 1/2 1/2 3 3 4 3 015X 18 3/4 1 1/2 1/2 3 3 4 3 020X 18 3/4 1 1/2 1/2 4 4 5 4 025X 25 1 1/2 1/2 4 4 5 4 030X 25 1 1/2 1/2 5 5 6 5 040X 31 1/2 2 1 5 5 6 5 050X 31 1/2 2 1 6 6 7 6 060X 36 1/2 2 1 6 6 7 6 Note: Non-Condensing models are shipped with standard vent size unless sidewall vent size is specified 'E' Dia. Air Inlet Accurate proportional control with 2-stage option Incorporates auto reset high limit & operator Three modes of operation: heating, DHW and remote Port for optional tank sensor Optional pump delay Flame failure feature Displays inlet/outlet temps & delta temp. Displays total run hours Molex harness connection for ease of service Weather proof enclosure Fusible link for over-voltage Proven field performance Firing Modes Available On/off, 2-stage and modulating (depending on model) *The Smartflame Control Panel is optional

MICOFLAME SERIES 2 AND GRANDE Gas Fired Residential/Light Commercial* and Commercial/ Industrial** Copper Tube Boiler for Hydronic Heating & Hot Water Supply Note: X=0 (Non-Condensing), X=2 (Condensing) Dimensions and Specifications - MicoFlame 2 - s 800-2000 Low NOx Up to 85% efficiency Non Condensing mode Up to 95% efficiency Condensing mode Copper Tube Heat Exchanger which meets lead-free regulations Durable metal fiber burner unaffected by high temps Vents up to 60 feet horizontally with 60 feet of air intake duct Suitable for use in negative pressure environments Complete diagnostic light package Easy access for inspection & cleaning of heat exchanger tubes Durable ceramic fiber refractory Secondary Heat Exchanger Condensing models only Simple to service with easy access to burner and fan *MicoFlame 2 **MicoFlame Grande 11 Dim. & Spec. (inches) "W" "D" "H" Water Connection Gas Connection Outdoor 'B' Dia. Venting *These models have two identical outdoor air inlets. When joining the two 8 inlets, use a 10 pipe. When joining the two 10 inlets, use a 12 pipe. **Appliance may be supplied with 2 openings that can be combined into this size. ***Non-Cond. models are shipped with standard vent size unless sidewall vent size is specified. Dimensions and Specifications - MicoFlame Grande - s 2010-4000 'E' Dia. Sidewall or Non- Condensing Standard Air Inlet Cond. Approx. Shipping Weights (lbs) 080X 45 3/4 44 1/2 18 3/4 2 1/2 1 8 8 10 8 500 580 100X 52 3/4 44 1/2 18 3/4 2 1/2 1 1/4 8 8 10 8 610 690 120X 62 44 1/2 23 1/4 2 1/2 1 1/4 10 10 12 10 732 828 140X 71 1/4 44 1/2 23 1/4 2 1/2 1 1/4 10 10 12 10 854 966 160X 80 3/4 44 1/2 23 1/4 2 1/2 1 1/2 12 12 14 12 976 1104 180X 89 3/4 44 1/2 23 1/4 2 1/2 1 1/2 12 12 14 12 1098 1242 200X 99 44 1/2 23 1/4 2 1/2 1 1/2 12 12 14 12 1220 1380 Cond. Control Panel Highlights Accurate proportional control with up to 4-stage option Incorporates auto reset high limit & operator Eight modes of operation for outdoor reset, heating, DHW and Remote Port for optional tank sensor Optional pump delay Flame failure feature Displays inlet/outlet temps & delta temp. Displays total run hours Molex harness connection for ease of service Weather proof enclosure Fusible link for over-voltage Proven field performance Firing Modes Available s 800-1000: On/off, 2-stage and modulating s 1200-2000: On/off, 2-stage, 3-stage, 4-stage and modulating s 2000-4000: 2-stage, 3-stage, 4-stage and modulating Dim. & Spec. (inches) "I" "K" "L" "W" "S" Water Gas Connection Connection Outdoor 'B' Dia. Venting 201X 6 68 34 5/8 54 5/8 33 3/8 3 1 1/2 12 12 14 12 1,585 1,635 250X 6 72 34 5/8 78 7/8 58 3 2 14 14 16 14 1,675 1,745 300X 6 72 34 5/8 78 7/8 58 3 2 14 14 16 14 1,750 1,820 350X 6 72 34 5/8 103 81 3/4 4 2 1/2 16 16 18 16 2,000 2,070 400X 6 72 34 5/8 103 81 3/4 4 2 1/2 16 16 18 16 2,200 2,270 *Note: E Dia.: join (2) 10 openings into common 14 and join (2) 12 openings into common 16. **Appliance may be supplied with 2 openings that can be combined into this size. ***Non-Cond. models are shipped with standard vent size unless sidewall vent size is specified. ****Water connections are 3 grooved at header. 'E' Dia. Sidewall or Non- Condensing Standard Air Inlet Cond. Approx. Shipping Weights (lbs) Cond. Input and Output Input Output - BTUH (Non-Cond.) Output - BTUH (Condensing) 080X 800,000 680,000 760,000 100X 1,000,000 850,000 950,000 120X 1,200,000 1,020,000 1,140,000 140X 1,400,000 1,190,000 1,330,000 160X 1,600,000 1,360,000 1,520,000 180X 1,800,000 1,530,000 1,710,000 200X 2,000,000 1,700,000 1,900,000 201X 2,000,000 1,700,000 1,900,000 250X 2,500,000 2,125,000 2,375,000 300X 3,000,000 2,550,000 2,850,000 350X 3,500,000 2,975,000 3,325,000 400X 4,000,000 3,400,000 3,800,000

MICOFLAME MODULATING SERIES Includes all the standard features of the MicoFlame Series 1, 2 and Grande plus... s 400-1000 modulate seamlessly down to 35% of input s 1200-4000 modulate seamlessly down to 40% of input Includes a Pulse Width Modulation (PWM) blower Firing Modes Available s 400-600: On/off and modulating s 800-1000: On/off, 2-stage and modulating s 1200-2000: On/off, 2-stage, 3-stage, 4-stage and modulating s 2000-4000: 2-stage, 3-stage, 4-stage and modulating Control Panel Highlights Accurate, fully modulating, proportional and PID control Incorporates auto reset high limit & operator Multiple modes of operation for domestic hot water, hydronic heating and outdoor reset Port for optional tank sensor Optional pump delay Flame failure feature Displays inlet/outlet temps & delta temp. Displays total run hours Molex harness connection for ease of service Weather proof enclosure Fusible link for over-voltage Proven field performance MicoFlame 1 - s 400-600 12 Input & Output Input Range [kbtu/hr x 100] Input Range [kw] Input [BTU/hr] Input [kw] Non-Condensing Condensing Output [BTU/hr] Output [kw] Output [BTU/hr] Output [kw] 040X 140-399 41.0-116.8 399,000 116.8 339,150 99.3 379,050 110.9 050X 175-500 51.2-146.4 500,000 146.4 425,000 124.5 475,000 139.1 060X 210-600 61.5-175.7 600,000 175.7 510,000 149.3 570,000 166.9 MicoFlame 2 - s 800-2000 Input Range [kbtu/hr x 100] Input Range [kw] Input [BTU/hr] Input [kw] Non-Condensing Condensing Output [BTU/hr] Output [kw] Output [BTU/hr] Output [kw] Input & Output 080X 320-800 93.7-234.3 800,000 234.3 680,000 199.1 760,000 222.5 100X 400-1000 117.1-292.8 1,000,000 292.8 850,000 248.9 950,000 278.2 120X 480-1200 140.5-351.3 1,200,000 351.4 1,020,000 298.7 1,140,000 333.8 140X 560-1400 164.0-410.0 1,400,000 410.0 1,190,000 348.5 1,330,000 389.5 160X 640-1600 187.4-468.5 1,600,000 468.5 1,360,000 398.2 1,520,000 445.1 180X 720-1800 210.8-527.1 1,800,000 527.1 1,530,000 448 1,710,000 500.7 200X 800-2000 234.2-585.7 2,000,000 585.7 1,700,000 497.8 1,900,000 556.4 MicoFlame Grande - s 2000-4000 Input Range [kbtu/hr x 100] Input Range [kw] Input [BTU/hr] Input [kw] Non-Condensing Condensing Output [BTU/hr] Output [kw] Output [BTU/hr] Output [kw] Input & Output 201X 800-2000 234.2-585.6 2,000,000 585.6 1,700,000 497.8 1,900,000 556.3 250X 1000-2500 292.8-732.0 2,500,000 732.0 2,125,000 622.2 2,375,000 695.4 300X 1200-3000 351.4-878.4 3,000,000 878.4 2,550,000 746.6 2,850,000 834.5 350X 1400-3500 409.9-1024.8 3,500,000 1024.8 2,975,000 871.1 3,325,000 973.6 400X 1600-4000 468.5-1171.2 4,000,000 1171.2 3,400,000 995.5 3,800,000 1,112.6 Dimensional specifications and safety standards are as per MicoFlame, MicoFlame 2 and MicoFlame Grande Note: X=0 (Non-Condensing), X=2 (Condensing)

BLUEFLAME EFFICIENCIES UP TO83% Gas Fired Commercial Copper Tube Boilers for Hydronic Heating and Hot Water Supply Diagnostic lights help troubleshoot over the phone Copper Tube Heat Exchanger meets lead-free regulations Durable stainless steel burner Adaptable to outdoor use Simple to service Slide out burner tray Slide out heat exchanger Easy side access for inspection of combustion chamber High temp ceramic fiber tiles in combustion chamber Very smooth and quiet operation Suitable for venting in low ceiling applications with use of power venter and low profile hood Optional Digital Temp control is extremely accurate to minimize standby losses from temp. overshoot Efficiencies up to 83% V A 33 26 1/2 13 11 3/4 29 3/4 B Dimensions & Specifications (inches) STANDARD VENTING "A" "B" "V" Nat. Gas L.P. 480 16 30 3/4 10 1 3/4 660 16 39 12 1 3/4 840 19 47 1/4 14 1 3/4 1020 21 55 1/2 16 1 1/4 1 1200 21 63 3/4 16 1 1/4 1 1380 21 72 18 1 1/4 1 1560 21 80 1/4 18 1 1/4 1 1740 21 88 1/2 20 1 1/2 1 1/4 1950 21 96 3/4 20 1 1/2 1 1/4 OUTDOOR VENTING 480 20 30 3/4 12 1 3/4 660 20 39 14 1 3/4 840 20 47 1/4 16 1 3/4 1020 20 55 1/2 18 1 1/4 1 1200 20 63 3/4 18 1 1/4 1 1380 20 72 20 1 1/4 1 1560 20 80 1/4 20 1 1/4 1 1740 20 88 1/2 22 1 1/2 1 1/4 1950 20 96 3/4 22 1 1/2 1 1/4 Smartflame 7800007 Control Panel Highlights* Incorporates auto reset high limit & operator Multiple modes of operation for domestic hot water, hydronic heating and outdoor reset Port for optional tank sensor Displays inlet/outlet temps and delta temperature Flame failure feature Alarm contacts Displays total run hours Snap on Molex connection for easy service Fusible link for over-voltage protection Input and Output Input - BTUH Output - BTUH Approx. Shipping Weight (lbs) MBH KW MBH KW 480 480 (140.6) 398.4 (116.7) 356 660 660 (193.4) 547.8 (160.5) 419 840 840 (246.1) 697.2 (204.3) 507 1020 1020 (298.9) 846.6 (248.1) 564 1200 1200 (351.6) 996.0 (291.8) 620 1380 1380 (404.3) 1145.4 (335.6) 698 1560 1560 (457.0) 1294.8 (379.4) 754 1740 1740 (509.8) 1444.2 (423.1) 830 1950 1950 (571.3) 1618.5 (474.2) 896

CERAFLAME Gas Fired Commercial Copper Tube Boilers for Hydronic Heating and Hot Water Supply Low NOx Up to 85% efficiency Minimum standby losses with estimated average efficiencies of 82% Durable metal fiber burner unaffected by high temps Copper Tube Heat Exchanger which meets lead-free regulations Vents up to 60 feet horizontally with 60 feet of intake air duct Suitable for use in negative pressure environments EFFICIENCIES UP TO 85% Smartflame 780001 Control Panel Highlights 2 stage proportional control Incorporates auto reset high limit and operator Multiple modes of operation Port for optional tank sensor Flame failure feature Displays inlet/outlet temps and delta temp Displays total run hours Snap on Molex connection for easy service Weather proof enclosure Fusible link for over voltage protection 14 Height Dim. A Vent Dim. Stand B Water Conn. C Water Conn. Dist. D Gas Height E 450 42 ½ 6 34 8 14 ½ 550 49 ¾ 6 42 1/8 8 14 ½ 650 49 ¾ 8 42 1/8 8 14 ½ Water Conn. Prim. Gas Conn. Input BTUH Output BTUH Approx. Shipping weight LBS 450 2 NPT 1 NPT 450,000 382,500 326 550 2 NPT 1 NPT 550,000 467,500 360 650 2 NPT 1 NPT 650,000 552,500 360 The copper tube heat exchanger assembly is complete with cast bronze headers exceeding lead-free regulations. It is designed with a maximum working pressure of 160 psig and is limited to 250 F outlet water temperature for heating and domestic hot water applications. The heat exchanger is a four pass two row design employing integrally finned 7/8" copper tubes. The burner is comprised of a lightweight tubular manifold with 60 orifices oriented for maximum air entrainment. The burner is self-cleaning, has a smooth light off and runs with minimum heat build up. The intermittent ignition pilot shuts down the main burner within 4 seconds of pilot flame failure (natural gas & propane).

SUREFLAME Gas Fired Commercial Copper Tube Boilers for Hydronic Heating and Hot Water Supply Diagnostic lights help troubleshoot over the phone Temperature control is extremely accurate to minimize standby losses from temperature overshoot Burner runs cool and requires minimum maintenance Adaptable to outdoor use Simple to service Very smooth and quiet operation Fully enclosed combustion chamber Copper Tube Heat Exchanger which meets lead-free regulations Suitable for venting in low ceiling applications with use of power venter and low profile hood Efficiencies up to 83% Smartflame 780001 Control Panel Highlights 15 Incorporates auto reset high limit and operator Multiple modes of operation Port for optional tank sensor Flame failure feature Displays inlet/outlet temps and delta temp Displays total run hours Snap on Molex connection for easy service Weather proof enclosure Fusible link for over-voltage protection EFFICIENCIES UP TO 83% Height Dim. A Vent Dim. Stand B Water Conn. C Water Conn. Dist. D Gas Height E 420 42 ½ 10" 34 8 14 ½ 520 49 ¾ 10" 42 1/8 8 14 ½ 600 49 ¾ 12" 42 1/8 8 14 ½ Water Conn. Prim. Gas Conn. Input BTUH Output BTUH Approx. Shipping weight LBS 420 2 NPT 1 NPT 420,000 348,600 296 520 2 NPT 1 NPT 520,000 431,600 331 600 2 NPT 1 NPT 600,000 498,000 331 The copper tube heat exchanger assembly is complete with cast bronze headers exceeding lead-free regulations. It is designed with a maximum working pressure of 160 psig and is limited to 250 F outlet water temperature for heating and domestic hot water applications. The heat exchanger is a four pass two row design employing integrally finned 7/8" copper tubes. The burner is comprised of a lightweight tubular manifold with 60 orifices oriented for maximum air entrainment. The burner is self-cleaning, has a smooth light off and runs with minimum heat build up. The intermittent ignition pilot shuts down the main burner within 4 seconds of pilot flame failure (natural gas & propane).

BOILER CONTROLS & TOUCHSCREEN DISPLAYS SOLA Boiler Control Remote operation through 4-20mA setpoint or fire-rate control (0-10Vdc optional) Outdoor reset control with viewable outdoor reset schedule Lead Lag operation up to 8 boilers, parallel-sequential modulation rate across all boilers Lead Lag operation with user-defined rotation schedule Lead Lag operation with fixed or 4-20mA (0-10Vdc optional) setpoint adjustment ModBus RTU communication protocol Available BacnetIP, BacnetMSTP, LonWorks and Metasys communication protocol Over 100 points of communication including inlet & outlet temps, flame signal, status & alarms, setpoint and fire rate adjustment PID load control algorithm High limit control, Boiler outlet, Stack temperature (if equipped) Delta-T limit control, prevent excessive temperature rise scenarios DHW priority: 10k ohm temperature sensor or aquastat contact PWM or 4-20mA firing rate modulation signal UL353 approved outlet temperature high limit Flame rod or UV flame detection Proven pilot option (models 3000 and up) Auxiliary contacts for system pump, air damper, etc. System sensor included SOLA Touchscreen Display LCD touchscreen user interface Viewable outdoor reset schedule Password setup for service personnel Real-time digital and analog temperatures, flame signal, firing rate, remote input signal information Digital I/O safety annunciation *Up to 6 points with R7910A *2 points with R7910B Trend Analysis USB file and screenshot download 15-item error lockout history with time and date stamp 15-item alert history with time and date stamp Complete diagnostic report when lockout occurs Real-time clock to keep track of when errors occur Up to 8 SOLA devices may be monitored and controlled with single display Fahrenheit/Celsius temperature readout Infinitely adjustable firing rate for manual operation Internal ModBus communication 16 SmartFlame Boiler Control Accurate proportional control Incorporates auto reset high limit and operator Multiple modes of operation for domestic hot water, hydronic heating and outdoor reset Tank sensor compatibility Pump delay functionality Flame failure feature Remote operation through 4-20mA or 0-10Vdc for setpoint Displays inlet/outlet temperatures and delta T Adjustable differential temperature setting Displays total run hours Molex harness connection for ease of service Error codes displayed in short form text for quick reference BTC4PA 2-stage, 3-stage or 4-stage boiler control Annunciation of activated stages on boiler BTCMPA Modulating boiler control using PWM signal Remote operation through 4-20mA or 0-10Vdc for firing rate

forward thinking CONTACT US CAMUS HYDRONICS LTD. 6226 Netherhart Road Mississauga, ON L5T 1B7 p: 905.696.7800 f: 905.696.8801 www.camus-hydronics.com camus@bellnet.ca Camus is continually setting new benchmarks of excellence through skillfully engineered and solidly constructed high-efficiency products designed to provide years of reliable service and comfort. Representation of our products is coast to coast as well as internationally through a growing list of knowledgeable and professional distributors. Additional specifications can be obtained by visiting our website or by calling your local Camus representative. The Camus Certified seal assures you that reliability, efficiency and serviceability are built into every single unit.