Access Control, Code Lock

Similar documents
For more information on Abloy UK visit ACCESS CONTROL

ARCHITECTURAL DOOR HARDWARE KEY PADS & CARD READERS CATALOG

UNC100 Integra Manual

CV-350 TCP/IP Access Control System. System Overview

Bewator Entro. The user-friendly, networkable access control system

NDC-F16. Access Control Panel. Installation Manual

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

RX Web - web based access control. The global leader in door opening solutions

ACCESS CONTROL A SAFE ENVIRONMENT THROUGH SECURED ACCESS

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

SiPass Entro Open the door to comprehensive security

KT-100 Door Controller

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Bewator Entro. Project Design Manual. SR34i version M T O T F L S. < Pass > Logga ut Meny Hjälp Boka.

DOLKPS1KB Programming & Installation Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

SiPass Entro open the door to comprehensive security

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

Flair 500 Series Annunciators

DESCRIPTION OF KEYPAD (Access module with segments)

U-Prox IP550. Wireless access control panel. Instruction manual. W i r e l e s s a c c e s s c o n t r o l p a n e l w i t h b u i l t i n r e a d e r

ARCHITECTURAL AND ENGINEERING SPECIFICATION

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

Installation Guide for inbiox60 Series Access Control Panel

Access Control Solutions

IPTS Group A New Breed of Integration

EntryCheck E70 Series

Operating Instructions Transponder code lock - Part 2 (split decoder)

HRX Technical Manual. Version 1.2

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

InBio X60 Series Access Control Panel User Manual

ATS1250/ door/4-lift DGP. Programming Guide

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

HAA2866 HAA2866 ERRATUM

SCR100 User Manual. Version:1.1 Date:Dec 2009

Access Control (card access)

SPLIT-DECODED CONTROLLER

TruPortal Wireless Locks Quick Reference

HARDwired Installation/ Owner s Manual

The Challenger Version 8 User Guide

Motor Lock Manual 840C-50, 841C-50, 841C-35, 851C-35, 851C-50, 850C-50. ASSA ABLOY, the global leader in door opening solutions.

Digital & Card Access Control Systems

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

WIRING DIAGRAM AND INSTRUCTIONS

Access control. SiPass Entro. Open the door to comprehensive security. Answers for infrastructure.

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

The only electronic locking system for hotels, halls of residence, geriatric hospitals that offers you an integral solution.

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

TX3 Series TX3-CX-1. Installation Manual

T4000 Security Communicator

VS-AXESS-4DLX Installation Manual

GE Security. Challenger V8 & V9. User Manual

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

EC-BOS-602/616 AX Security

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD AND CARD READER

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Aperio Technology Wireless access control - The evolution starts here

HRX3000. Technical Manual

VAP304 PRO INSTALLATION & OPERATION MANUAL

To activate the Net2 alarm integration software the correct check box must be ticked on the features tab in the Net2 server configuration utility.

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Challenger Series Users Manual

SMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1

Networked Access Control Panel. Installation Guide

ELT-KLED EliteSuite LED Keypad Installation Manual

User manual for CPR32-NET network controller

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

DOLKPL1KB DOLKPS1KB DOLKSF1KB

SIB CATALOGUE. range. S100EM EM 125KHz 5-6cm. S100MF MIFARE 13.56KHz 3~5cm

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

IDS816 User Manual H Issued January 2009

ABLOY FIRE DOOR CLOSING SYSTEMS

Challenger10 Users Manual

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Exceptional solutions for key and portable item control. electronic lockers and key cabinets

Electronic Solutions for Education

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Wayne State University Police Department. Alarm/Card Access Specification s & Standards

Product Data Sheet. Remote Terminals. Features:

ACCESS CONTROL SOLUTIONS ACTEC SERIES

It s time to change! Follow me and discover SMARTair for flexible access control

YALE SECURE CONNECT. Delivering a premium digital locking solution with flexible control and peace of mind.

Wireless Keypad GKP-S8M

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Sync. Smart Home Alarm

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

It s time to change! Follow me and discover SMARTair for flexible access control

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

Contents. Glossary

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Wireless Access Control Light Commercial Lockset. WIACCOCAT - Wireless Access Control Light Commercial Lockset Catalogue_

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Contents. 30 References

DIGI*TRAC Annunciator Guide

Cardax System Comparison

ecliq Product Catalogue

security timeless design innovative products inspired technology

Transcription:

ACCESS CONTROL Solicode is a series of code locks easy to mount. The code locks provide access control without complicated key management in premises that do not require high security.

Access Control, Code Lock Stand Alone Reader / Code Lock PCR-40 Proximity reader SOLICARD PCR-40 the versatile compact proximity cardreader, PCR-40 is a code lock, stand-alone cardreader or an online cardreader. The compact and cost-effective proximity cardreader in a timeless design, with a built-in DAC interface to for easy installation directly to LCU9016, 6416CE and 4000CE. Features / Function SOLICARD PCR-40 has clear back-lit symbols, such as green/red man, alarm status, enter code and show card. SOLICARD PCR-40 is used on inside doors to prevent unnecessary passing, firstly on doors that don t demand a high security. Examples of such premises are locker rooms, internal storage, inside doors and office doors. SOLICARD PCR-40 has built-in power that can deliver 12V 0,6A for problem-free control of electric strikes or electric locks. SOLICARD PCR-40 can work as stand-alone and is then programmed directly via the keypad, or online wich facilitate the authority administration. With a SOLICARD PCR-40 you can always grow from the stand-alone reader to an online system with several thousands of doors. Without having to replace any reader. The buttons have a distinct touch response. SOLICARD PCR-40 can also be used as a code lock and as an alarm bypass facility when it is part of a control unit with at least one DAC30 connected. Indications Cardreader running/ready Door unlocked Common code/code lock function Card + PIN code Blocked for access Shows alarm status for alarm authorised card Invalid card Material PC plastic with black sticker Halone and Halogen free Fulfill the requirements for IP54 Stainless push buttons Power supply: 12-24 V AC / V DC DC Out: 12 V DC 0,6 A To run electric lock Power consumption: 100 ma Weight: 0,5 kg Temperatur range reader: -20ºC to +70ºC Built-in DAC interface directly connected to LCU9016, 6416CE and 4000CE Other Has a built-in tamper switch Lockable casing Cast base plate 234 Assa Mini Catalogue 2006

Access Control, Code Lock Compact Code Lock, Two Codes Solicode 190 Solicode 190 is a compact code lock easy to mount. It provides access control without complicated key management in premises that do not require high security. The code lock is suitable for interior and exterior use. The code lock is preset for two 4- or 6-digit access codes that can be easily reprogrammed later by using the keypad. Features / Function The code lock features an automatic cancellation of opening time (1-999 sec.) at door opening, when an electric strike with a bolt contact is connected. The code lock is not dependent on continuous voltage, which enables supply through a time switch. Code 2 can be blocked e.g. via time switch. The buttons have a distinct touch response. The code lock has a lockable capsule, cast base plate and capsule of zinc alloy with white or black powder paint as standard. Indications Programming mode Programming accepted Programming not accepted Invalid code block Unlocked door Key-pressing Voltage: 12-24 V AC / V DC Maximum current consumption: 210CL = 80 ma, 210DA = 110 ma Output, voltage or free relay closing: 1 A / 24 V Assa Mini Catalogue 2006 235

Access Control, Code Lock Compact Code Lock with Lighting, Seven Codes SOLICODE 210 Solicode 210 is a compact code lock for easy mounting. It provides access control without complicated key management in premises that do not require high security. The code lock is suitable for interior and exterior use. The code lock is preset for seven 4- or 6-digit access codes that can be easily reprogrammed later by using the keypad. Features / Function The code lock features an automatic cancellation of opening time (1-999 sec.) at door opening, when an electric strike with a bolt contact is connected. Model 210DA has a duress alarm function. The code lock is not dependent on continuous voltage, which enables supply through a time switch. There are seven 4- or 6-digit codes where codes 5 and 6 can be blocked through e.g. a time switch and code 7 can be time-limited from 1 to 9 days. The key pad is back-lit and the buttons have a distinct touch response. The code lock has a lockable capsule, cast base plate and capsule of zinc alloy with white or black powder paint as standard. Indications Programming mode Programming accepted Programming not accepted Invalid code block Unlocked door Key-pressing Material Cast zinc alloy with white or black powder coating as standard Stainless push buttons Other surface coatings as brass and chrome (frosted/silver) are available Voltage: Maximum current: Maximum current: Output, voltage or free relay closing 12-24 V AC / V DC 210CL = 80 ma 210DA = 110 ma Miscellanous Seven 4- or 6-digit codes Code 5 or 6 can be jointly blocked via e.g. time switch Code seven can be time limited from 1 to 9 days Invalid code block Durless alarm is a function in 210DA Lockable casing Cast base plate 236 Assa Mini Catalogue 2006

Access Control, Code Lock Code Lock for Flush Mounting SOLICODE 211 Solicode 211 is a compact code lock for flush mounting. The code lock provides access control without complicated key management in premises that do not require high security. Examples of this type of locations are locker rooms, interior storage rooms and entrance doors to apartment buildings. The code lock is suitable for interior and exterior use. The push buttons have a distinct touch response. Solidcode 211 is a code lock in a flush-mounted box suitable for use in locations where there is an extreme risk for tampering. Features / Function The code lock features an automatic cancellation of opening time (1-999 sec.) at door opening, when an electric strike with a bolt contact is connected. Cast zinc alloy box with front and push buttons of stainless steel. There are seven 4- or 6-digit codes where codes 5 and 6 can be blocked through e.g. a time switch and code 7 can be time-limited from 1 to 9 days. The push button set can be installed in a panel frame instead of the standard box. Indications Programming mode Programming accepted Programming not accepted Invalid code block Unlocked door "Key-pressed" indications Material Stainless front Stainless push buttons Flush mounting case in zinc alloy Voltage: 12-24 V AC / V DC Maximum current: 210CL = 80 ma Maximum current: 210DA = 110 ma Output, current or clean contact relay 1 A / 24 V Miscellanous Seven 4- or 6-digit codes Code 5 or 6 can be jointly blocked via e.g. time switch Code seven can be time limited from 1 to 9 days (temporary access code) Invalid code block Lockable casing The keypad can be fitted in Panel frame 1 instead of the standard box Assa Mini Catalogue 2006 237

Access Control, Door Access Controller DAC-20 The DAC-20 is designed for the SOLICARD 4000 and 6416 control units. Both systems have the same simple connection to the DAC-20 using 2-wire communication. The DAC-20 forms a communications hub at the door to which the lock, reader and exit switch can all be connected. By adding DAC-30RC it s possible to connect alarm, door automatics, time controlled outputs, etc. This approach allows the same basic solution, regardless of the type of door or equipment. 2-wire communication means fewer cables. This means that you only need 4 wires to connect the DAC-20 two wires for the communication and two wires for the power supply. When serial motorlocks or permanent alarm bypass will be used, use DAC-30II. Power supply: 17-24 V AC / V DC Max power consumption: 150 ma Weight: 330 g Temperature range: +5ºC to +40ºC (Non-condensing) Serial motorlocks and alarm bypass are not supported. For that purpose use DAC-30II Accessories DAC-30RC, Relay board with 4 programmable relays DAC-30AI, Double-balanced alarm interface for connection to external alarm Can not be connected to: SOLICARD 4000 and 6416 control units Casing Shock-resistant ABS-plastic SIS 166653 Halogen/Halogenfree Relay functions DAC-20 wide 30RC Time-controlled output Buzzer Temporary ABP (Alarm by-pass) Door automatics Door position Electric strike Temporary ABP which does not drop at door open to long Tamper Mirror blocking input in zone Balanced OUT/SAB Reader technology CL/DATA (Magnet), Wiegand, Solicell (Touch memory), Prox 238 Assa Mini Catalogue 2006

Access Control, Door Access Controller DAC-30 II The DAC-30 is used with our 4000, 6300 and ARX systems. Both systems have the same easy two-wire communication system. DAC-30 is a connection point as well as a door controller, intended to be fitted at each door. To the DAC-30 you then connect locks, readers, exit button, automatic door controllers etc. This provides for similar solutions regardless of the door type and equipment. Two-Wire communication means fewer cables, all you need is four wires to connect a DAC-30, two wires for the communication and two wires for the power supply. No separate motor lock controllers is necessary when connected to some models of Assa and Abloy motor locks since this functionality is already included in the DAC-30. Communication between the DAC-30 and the motor lock is encrypted in these cases providing for increased security. BILD!!!!!!! Power supply: Max power consumption: Temperature range: 12-24 V AC / V DC 80 ma +5ºC to +40ºC (Non-condensing) Accessories DAC-30RC, Relay board with 4 programmable relays DAC-30AI, Double-balanced alarm interface for connection to external alarm Can be connected to: SOLICARD 4000CE and LCU9016 DAC-30II Casing Shock-resistant ABS-plastic SIS 166653 Halogen/Halogenfree Other Time-controlled output Buzzer Temporary ABP (Alarm by-pass) Automatic door controllers Door monitor switch Security mode (motor lock) Open mode (motor lock) Locked mode (motor lock) Electric strike Temporary ABP that remains active if door is open to long Tamper Reader technology CL/DATA (Magnet), Wiegand, Solicell (Touch memory), Prox Assa Mini Catalogue 2006 239

Access Control, Door Access Controller SOLICARD 6390IF, 6353KS 6390IF SOLICARD 6390IF and SOLICARD 6353KS are two interfaces for connection of OEM readers such as magnet (clock/data), Wiegand (data-0/data-1) and Dallas to the Solicard system. 6390 I/F is a general interface that can be easily configured for a number of different reader modes. 6390 I/F is equipped with inputs for a 3x4 X/Y matrix keypad, sabotage switch, and outputs for six LED:s and a buzzer. The 6353KS contains the same I/F as the 6390 I/F along with a keypad that makes it suitable for all applications where a OEM reader needs to be combined with a keypad. For instance, a dallas or proximity reader that will be used for alarm manouvering or with PIN-code. 6353 KS has keys with a distinct touch response and backlit symbols, such as a green/red man, alarm status, enter code and swipe card. The 6353KS can also be used where only common code is required, as a code lock or as an alarm bypass device. SOLICARD 6390IF, Reader interface Magnet (Clock-data) for 6389MWL, 6383, 6320 Wiegand (Data 0-data 1) for 6385 ( Indala) Dallas for 6370ST SOLICARD 6390IF, Voltage: 12 V DC Power consumption: 10 ma + connected load Weight: 170 g Temperature range: -5ºC to +70ºC (Non-condensing) SOLICARD 6390IF, Casing White ABS-plastic 6353KS SOLICARD 6353KS, Reader interface Magnet (Clock-data) for 6320 Wiegand (Data 0-data 1) for 6385 ( Indala) Dallas for 6370ST SOLICARD 6353KS, Voltage: 12 V DC Power consumption: 70 ma + connected load Weight: 895 g Temperature range: -30ºC to +70ºC (Non-condensing) SOLICARD 6353KS, Casing IP54 Cast zinc alloy with white or black powder coating Stainless steel push buttons For special surface finish (gold or chrome), contact Solid 240 Assa Mini Catalogue 2006

Access Control, Door Access Controller SOLICARD RCE-16 RCE-16 is a relay control unit adapted for the 6416. The relay control unit can be used with Solicard 6416HS, which is an elevator control program and with Solicard 6416PB, which is a post box program. It is also possible to use it in shop fittings where you have a need to control locked display cases, mail boxes in the apartment building market and offices and in locker rooms in e.g. public swimming baths. RCE-16 consists of 16 LED indicated relays with selectable potential free switching contacts between NO/NC, the selection is made with jumper links. It has a built-in tamper switch and four diodes indicating the status of the RCE-16. Power supply: 12-24 V AC / V DC Current consumption with 24 V DC is 11 ma Current consumption with 12 V DC is 16 ma Load when all relays are used in RCE-16 170 ma with 24 V and 300 ma with 12 V Relay max load 1 A (24 V) Operating temperature +5ºC - + 40ºC Casing Shock-resistant ABS-plastic SIS 166653 Halogen/Halon free plastic Indications TX - Green indication (Tranmits data to the control unit) RX - Orange indication (Receives data from the control unit) PWR - Yellow indication (Power) ALLIVE - Blue indication (Works) Other Fulfill the requirements for IP44 Assa Mini Catalogue 2006 241

Access Control, Door Access Controller SOLICARD ARX LCU9016 Area of use is office, hotels, public buildings with high secure requiremants. The local central unit in the ARX-family that is connects directly to the TCP/IP network. The LCU can control up to 16 doors/32 card readers. The LCU is based on the Linux operating system, has flash memory and can easily be adapted to many future requirements. LCU9016 will integrate seamlessly in the network and take advantage of existing DNS and DHCP servers. SOLICARD ARX LCU9016 is equipped with memory to handle over 100 000 cards and over 1000 schedules, day-types and other settings. A separate log-event memory can store more than 30 000 log-events. The LCU s can work stand alone in the case of a network failure. Card holders will get access to doors according to normal rules and log events are stored locally. When the network comes back up the stored log events are transmitted to the server automatically. All communication to the server uses PKI certification for authorization and SSL encryption for data protection, which is the same level of security that Internet banks are using. Function I the base configuration the LCU is equipped with one loop card for four doors, which each can have two card readers /in/out/ and an open-button. Fully equipped with 4 loop cards 16 dorrs can be controlled. Memory with barttery backup Real time clock with calendar Event buffer with capacity to store >30 000 events Memory for 100 000 cards with individual PIN codes > 1 000 schedules Additional functions: Alarm arm/disarm, disabled (extra time for open door), officer function (authority to permanently unlock door) SNMP based supervision Power supply: Weight: Temperature range: 17-28 V AC or 17 40 V DC 3,0 kg +5ºC to +40ºC Accessories Loop card 4014LC, 4 doors Relay card 6416RC, 4 relays where 3 are software controlled Transformer ST60S Battery backup 245PS Controlled by PC with Windows 2000/XP 242 Assa Mini Catalogue 2006

Access Control, xxxxxxxxxxxx SOLICARD PCR-30 PCR-30 can control both electric strike and electrical lock. By the control unit connection you simplify the administration of the authorities. The buttons have a distinct touch response. PCR-30 can also be used as a code lock and as an alarm bypass facility when it is part of a control unit with at least one DAC connected. The reader contains a DAC interface allowing it to be connected directly to the control units 4000CE, 6416CE and LCU9016. Indications Cardreader running/ready Door unlocked Common code/code lock function Card + PIN code Blocked for access Shows alarm status for alarm authorised card Invalid card Power supply: 12-24 V AC / DC Weight: 0,5 kg Temperature range reader: +5ºC to + 70ºC DC Out 12 V DC 0,6A Power Consumption 100 ma Buit-in DAC interface Directly connected to LCU9016, 6416CE, 4000CE Material PC plastic with black sticker Halon and Halogen free Fulfill the requirements for IP54 Stainless push butons Other Has a built-in tamper switch Lackable casing Cast base plate Assa Mini Catalogue 2006 243

Access Control, Proximity Reader SOLICARD 6485PL SOLICARD 6485PL is a proximity reader with a backlit keypad and interface. The reading distance is approx. 5-10 cm. 6485PL is equipped with clear backlit symbols, such as green/red man, alarm status, enter code and present code carrier. Both cards and tags exist as code carriers. Both types are passive, i.e. they don t contain any batteries. The tags are practical since they can easily be placed on a keyring. The cards are combicards, which means that they include both the proximity technology and a magnetic stripe making it possible to use it in a magnetic cardreader connected to the same system or another magnetic system. The 6485PL is mainly used for convenience and is suitable for both indoor and outdoor use, since it fulfils the IP54 demands. The buttons has a distinct touch response and the digits are backlit. 6485PL can also be used as an alarm bypass device or as a code lock. It is preferably used in environments such as garages and offices and in public premises. The reader contains an interface allowing it to be connected directly to a control unit/door controller in the 4000 and 6000 systems. Function I the Material White Pc plastic with black sticker Halon and Halogen free Fulfill the requirements for IP54 Power supply: Power Consumption: Card PLK1/PLK2 TAG PLT 12 V DC 100 ma 20ºC < > +55ºC -30ºC < > +100ºC Accessories 6160RS Rain cover Can be connected to SOLICARD 4000 and 6000 system. Demands no 6390IF/6355KS interface, connected directly to Solicard 244 Assa Mini Catalogue 2006

Assa Mini Catalogue 2006 245

246 Assa Mini Catalogue 2006

Assa Mini Catalogue 2006 247