A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Similar documents
VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

Natural Heat VITOCAL 300-A VITOCAL 350-A. Air source heat pumps

Heating with natural heat

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

Heat pumps. Heating systems Industrial systems Refrigeration systems

Heating with airborne and geothermal energy making the best possible use of renewables

Heating with airborne and geothermal heat

BWL air heat pumps BWS brine heat pumps

Technical data LA 60TUR+

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Advance Split

Starting current with soft starter Fuse protection

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

Technical data LA 60TU

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Technical data LA 28TBS

VIESMANN. Installation and service instructions VITOCAL 200-S. for contractors

Technical data LA 9S-TU

PRODUCT DATA SHEETS HEAT PUMPS

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

High temperature air-to-water heat pumps

GHP AWO 38 Technical overview

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

HT V2 HT Split

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

MODEL LA 6 MI LA 9 MI LA 12 MI LA 16 MI. Heat output (kw)/cop at A-15/W35 5.9/ / / /2.33

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

Pool heating, efficiently

VIESMANN. Installation and service instructions VITOCAL 300-A. for contractors

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Saving energy comes naturally to us.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Starting current with soft starter Fuse protection. Heat source connection

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

NIBE SPLIT ACVM 270 Air/water heat pump

TERMO Combi Cylinder TECHNICAL INFORMATION

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

THE HEAT PUMP CHOICE OF PROFESSIONALS

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Starting current with soft starter Fuse protection

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

HIWARM COMPACT kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Air Cooled Chillers & Heat Pumps WinPACK HE-A

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

EEDEN technical data ERHQ AA

VIESMANN. Installation instructions VITODENS 200-W. for contractors

REMKO HYBRID HEAT PUMPS

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

CDP 40 SWIMMING POOL DEHUMIDIFIER

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

LZT High efficiency air to water heat pumps with E.V.I. compressors

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

HYDRONIC RESIDENTIAL

With the world-renowned SIGMA PROFILE

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

500 EX Fusion Compressor Series

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

LZA High efficiency air to water heat pumps with HP compressor

comfort BY CONTROL POOL AND SPA HEATING SOLUTIONS

RAMIRENT CDT 30. Applications Damage service Building drying Water works Dry storing FEATURES

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Product Range. Overview 2015.

CITY OPEN - CITY BOX from 25 to 35 kw

Transcription:

Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability, safety and quiet running through new output regulated compressor (digital scroll technology) & Particularly suitable for underfloor heating systems & Flow temperature up to 60 C & Output control from 3 to 9 kw & Does not require permits (subject to location, approval by the local power supply utility is required) & Low CO emissions through high COP value of 3.8 (COP = Coefficient of performance) to EN 14511 (air C / water 35 C at 5 K spread) & Highest efficiency at every operating point and low running costs through electronic bi-flow expansion valve & Low operating noise through radial fan and additional night mode with reduced fan speed & For indoor installation with integral heating circuit pump, expansion vessel, diverter valve (central heating/dhw), safety equipment block, and fitting for electric instantaneous heating water heater & Efficient defrosting through circuit reversal & Convenient new heat pump control unit with telecontrol and remote monitoring enables connection to the Vitocom 100 & Optional indoor and outdoor installation, minimum footprint of 865 x 780 mm. Compact indoor corner installation & Hermetically sealed refrigerant circuit. For amount of refrigerant less than 6 kg, the annual inspection obligation does not apply. 16 VIESMANN VITOCAL

Delivered condition Vitocal 300-A, type AWC-I (for indoor installation) Air/water heat pump with an output of 3 to 9 kw. Heat pump with compact dimensions, electronic starting current limiter and polyester coated casing (colour: Vitosilver). Low noise and vibration emissions through multiple vibration-mounted, digital, output regulated Compliant scroll compressor for a maximum flow temperature of up to 60 C at an air temperature of +5 C. With electronic expansion valve for highest possible COP. Heightadjustable feet. Coated evaporator fins ensure corrosion resistance where air has a high salt content. CFC-free refrigerant (R407 C). Stainless steel plate-type heat exchanger (1.4401/1.4301) for heat transfer to the heating system. Circuit reversal defrost system with genuine ondemand defrosting. Integral circulation pump (VIRS 15/7-3) for the heating circuit, central/dhw heating 3-way diverter valve, expansion vessel (10 l) and safety assembly, as well as a slot to integrate an electric instantaneous heating water heater (accessory) and integral control panel with built-in phase monitoring. Weather-compensated, digital heat pump control unit WPR 300 for wall mounting (the required connecting cables are not part of the standard delivery of the heat pump (accessories)). Vitocal 300-A, type AW-O (for outdoor installation) Air/water heat pump with an output of 3 to 9 kw. Heat pump with compact dimensions and electronic starting current limiter. Suitable for outdoor installation through weatherproof casing with polyester powder coating (the required hydraulic connection lines are not part of the standard delivery of the heat pump (accessories)). Low noise and vibration emissions through multiple vibration-mounted, regulated, digital Compliant scroll compressor with a maximum flow temperature of 60 C at an air temperature of +5 C. With electronic expansion valve for highest possible COP. Height-adjustable feet. Coated evaporator fins ensure corrosion resistance where air has a high salt content. CFC-free refrigerant (R407 C). Stainless steel plate-type heat exchanger (1.4401/1.4301) for heat transfer to the heating system. Circuit reversal defrost system with genuine ondemand defrosting. Integral safety assembly. With integral control panel. Weather-compensated, digital heat pump control unit WPR 300 for wall mounting (the required connecting cables are not part of the standard delivery of the heat pump (accessories)). Weather-compensated heat pump control unit WPR 300 Digital heat pump control unit for wall mounting. With integral energy calculation in conjunction with the RCD system of the heat pump. For one heating circuit without mixer and one heating circuit with mixer. With cylinder temperature control for one DHW cylinder. For the control of an additional heat source in dual-mode, parallel operation (e.g. oil/gas fired boiler) and an instantaneous heating water heater. Cascading and swimming pool water heating possible (accessories required). Menu-guided operation with plain text fault display. With diagnostic system and central fault message output. Remote transmission with the Vitocom 100. An outside temperature sensor, flow and return temperature sensors plus sensors for the primary inlet and outlet are part of the standard delivery. Order the required cables to the heat pump separately (accessories). Accessories (subject to order, packed separately) & Heating circuit pump & Safety equipment block with safety assembly & 3-way diverter valve R 1" & Instantaneous heating water heater / electric booster heater & Heating water buffer cylinder & Plate-type heat exchanger & Wall outlets made from EPP (expanded polypropylene) & Weather grille & Electrical cables for connecting the heat pump and the control unit (5, 15 and 30 m long) & Hydraulic connection set for flexible routing under ground (5, 10, 15, 0 or 5 m long). For connecting the heat pump to the water system in the building (only required for external installations) & Pipe liner with wall seal flange or wall seal ring for bringing the hydraulic connecting set pipes into the building & Cylinder temperature sensor & Remote control & Contact temperature sensor & Heating mixers & Mixer motor & DHW cylinder & Electric immersion heater for DHW cylinder & Silencer hood for mounting on the external wall. In case of internal installation of the heat pump for reducing the inlet and outlet sound emission (in systems where noise could be a problem) & Sound insulation set for the Vitocal 300-A, type AW-O, for the reduction of air-borne noise at the inlet and outlet. VITOCAL VIESMANN 17

. Specification Technical data, 400 V appliances Vitocal 300-A Type AWC-I AW-O Output data at 100 % to EN 14511 (/35 C, 5 K spread) Rated heating output kw 9.0 Power consumption kw.37 Coefficient of performance (COP) 3.8 Output control kw 3 to 9.0 Output data at 100 % to EN 55 (/35 C, 10 K spread) Rated heating output kw 9.9 Power consumption kw.5 Coefficient of performance (COP) 4.4 Output control kw 3 to 9.9 Heat yield Fan power W 180 10 Air volume m 3 /h 3300 3500 max. permiss. pressure drop Pa 0 (on the ventilation air and extracted air side) Min. air temperature C 0 Max. air temperature C 35 Proportion defrost time/runtime % 3 to 5 Heating water (secondary) at 5 K spread Capacity litres 3.5 Min. throughput * 1 l/h 1950 Pressure drop* mbar 50 40 Max. flow temperature C (A 0) 40 C (A-5) 55 Electrical values Heat pump Rated voltage 3/N/PE ~ 400 V/50 Hz Rated current (max.) A 6.9 Starting current* 3 A 14.0 Starting current A 44.0 (with stalled armature) Fuse protection A 3 x 16 slow Fan protection 6.3 A H slow Protection IP 1 IP 4 Control circuit rated voltage 30 V~ 50 Hz Control circuit protection 6.3 A H slow Refrigerant circuit Refrigerant R 407 C Fill volume 5. kg Compressor Type Hermetically sealed digital Scroll with bypass Dimensions Total length mm 770 100 Total width mm 863 1363 Total height mm 1833 Permissible operating pressure bar 4 Connections Heating flow and return R1½" R1¼" Condensate hose (Ø internal) mm 5 Weights Total weight kg 55 75 Sound power level Weighted total sound power level* 4 at 80 to 100 % output db(a) 55* 5 64* 6 at 50 to 79 % output db(a) 55 59 at 30 to 49 % output db(a) 55 55 *1 Always safeguard the min. throughput. * With the connection pipes supplied as part of the standard delivery. *3 With electronic starting current limiter (full wave soft starter). Required for safeguarding the Z characteristics. *4 These measurements were taken in a semi-freestanding area under the following conditions: Inlet temperature 0 C (±3 K); flow temperature 50 C (±5 K). *5 Test with reference to DIN EN ISO 3744. *6 Test with reference to ISO 1361-1. 18 VIESMANN VITOCAL

Technical data, 30 V appliances Vitocal 300-A Type AWC-I AW-O Output data Data not yet available at time of printing Heat yield Fan power W 180 10 Air volume m 3 /h 3300 3500 max. permiss. pressure drop Pa 0 (on the ventilation air and extracted air side) Min. air temperature C 0 Max. air temperature C 35 Proportion defrost time/runtime % 3 to 5 Heating water (secondary) at 5 K spread Capacity litres 3.5 Min. throughput * 1 l/h 1950 Pressure drop* mbar 50 40 Max. flow temperature C (A 0) 40 C (A-5) 55 Electrical values Data not yet available at time of printing Refrigerant circuit Refrigerant R 407 C Fill volume 5. kg Compressor Type Hermetically sealed digital Scroll with bypass Dimensions Total length mm 770 100 Total width mm 863 1363 Total height mm 1833 Permissible operating pressure bar 4 Connections Heating flow and return R 1½" R 1¼" Condensate hose (Ø internal) mm 5 Weights Total weight kg 55 75 Sound power level Data not yet available at time of printing *1 Always safeguard the min. throughput. * With the connection pipes supplied as part of the standard delivery. VITOCAL VIESMANN 19

Dimensions, type AWC-I A Routing power cables B Hydraulic connections (either on the l.h. or r.h. side) C Air inlet D Air outlet (optionally on the l.h. or r.h. side) HR Heating water return HV Heating water flow KO Condensate drain TV Heating water flow for DHW heating 0 VIESMANN VITOCAL

Dimensions, type AW-O VITOCAL VIESMANN 1

Output diagrams* 1 Type AWC-I / AW-O COP at 35 and 45 C heating water flow temperature T HV A Output at 35 and 45 C heating water flow temperature T HV B Power consumption at 35 and 45 C heating water flow temperature T HV Output data Operating point A/W35 A7/W35 A/W45 A-7/W35 A-7/W45 A7/W45 A7/W55 A10/W35 A-15/W35 Heating output kw 9.0 11.3 8.3 6.7 6.5 11.0 10.5 1.1 5.13 Power consumption kw.36.4.76.4.8.89 3.5.37 1.97 Coefficient of performance (COP) 3.8 4.7 3.0.8.3 3.8 3.0 5.1.6 *1 Data for the COP in tables and diagrams calculated with reference to DIN EN 14511. VIESMANN VITOCAL