ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Similar documents
Twin Photobeam Detectors Manual

Long-Range Barrier Sensors

Auto Dialer. Manual E-921APQ E-921GPQ

CAUTIONS ON INSTALLATION

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Solar Powered Wireless Photobeam Sensors

Fence and Gate Catalog

Voice Dialer. Manual E-921CPQ E-921KPQ

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

Active Infrared Multi Beam Sensors. R Series

Active Infrared Multi Beam Sensors

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

DUAL OPTIC. Installation manual

Description. Optex Incorporated

Radio Frequency Do s & Don ts

FLAME SENSOR FS-2000E

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Quadruple-beam photoelectric detector

English. Series. Installation and Use Manual

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Installation And commissioning manual. Series S Double Beam 1/16

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

PARVIS Safe and tranquil thanks to Parvis

Movement Detector GJD 300

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

English. Italiano. Português. Françias. Español

SL-BR AC Model Bridge Light Installation & Service Manual

D-Tect 2 GJD300 Quad PIR Movement Detector

Photoelectric Beam Detector

No Touch Door Release Exit Sensor ACA-NTEB

Immunity. P/N: ver.b

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Commercial Series TriTech Motion Detector. Reference Guide

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Operations Manual. Motion Detector Module Model ZS10

SAFETY INFORMATION AND WARNINGS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MINI-BEAM Expert Series

R-GAGE QT50R-AFS Sensor

INDEX. Installation recommendation

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

PHOTOELECTRIC BEAM SENSOR

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

CONFIGURATION OF THE OPTICALS

Installation Instructions

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

A10. Installation & Operation Manual. Flow Switch. For the latest version of this manual, visit kteksolidslevel.com.

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

Beacon 800 Gas Monitor Operator s Manual

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

PHOTOELECTRIC DETECTOR

D-TECT Dual Tech. GJD360 Triple Technology External Detector

D-TECT 2 IP. GJD230 IP Motion Detector

9780 SW Freeman Dr. Wilsonville, OR USA Tel: Fax: crimsontrace.com Rev002 12/15

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

INFRARED MODULATED BARRIERS

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

Laser Distance Sensor Type M Analog-Output

STANDARD FEATURES SPECIFICATIONS

PHOTOELECTRIC DETECTOR

Campers Alert TM Portable System Hunters Alert TM Portable System

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

ZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450

ESP TECHNOLOGIES LIMITED

PodView Level Indicator LI40 Series Manual

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

52 CEILING FAN. Owner s Manual Models #50336, 50337

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Transcription:

Also available from SECO-LARM: E-960-D290Q E-932-D33TBQ E-9622-4B25 Twin Photobeam Detectors Range: up to 290' outdoors. Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain, snow, mist, etc. Weatherproof, sunlight filtering case for indoor and outdoor conditions. Quick easy installation with builtin laser-beam alignment system. E-932-S16RRQ Flush-Mount Photobeam Sensors E-932-D33TBQ Photoelectric Through-Beam Sensor. E-932-S16RRQ Photoelectric Reflective-Beam Sensor. Suitable for entrances, hallways, room in office or home. Fits single-gang box. Adjustable alignment angle from +/-15 o horizonatally / vertically. Curtain / Barrier Sensors Available in 4, 6, 8 or 10 beams. Range: 25 ft. outdoor, 50 ft. indoor. Slim-line design 7 / 8" x 1 5 / 16. Weatherproof IP65 construction. Triggers on breaking of any single or 2 adjacent beams (programmable). ENFORCER SENSOR MANUAL Multi-Frequency Quad Photobeam Detectors E-964-Q660Q 660 ft. (200m) outdoors, 1320 ft. (400m) indoors E-964-Q495Q 495 ft. (150m) outdoors, 990 ft. (300m) indoors E-964-Q330Q 330 ft. (100m) outdoors, 660 ft. (200m) indoors E-964-Q165Q 165 ft. ( 50m) outdoors, 330 ft. (100m) indoors WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of three (3) years from the date of sale to the original consumer customer. SECO-LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else. NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM. SECO-LARM's ENFORCER Twin Photobeam detector series are protected by the following patents: U.S. pat. no. D485774 ; Taiwan pat. no. 89463 ; China pat. no. ZL0331103.0 Other international patents are pending., Inc. 16842 Millikan Avenue, Irvine, CA 92606 Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 PITSW3 MIE964-D_US_P0804u.pmd Website: www.seco-larm.com E-mail: sales@seco-larm.com SECO-LARM Note: Products with model number that ends with "Q" or have a green Q sticker represents RoHS compliant products.

TABLE OF CONTENTS Features: Introduction... 2 Features... 2 Overview... 3 Wiring Diagram... 4 Choosing a Location... 4 Running the Cable... 4 Multiple Sensor Sample Applications... 5 Typical Installations... 5 Wiring the Transmitter Wall Mount... 6 Wiring the Transmitter Pole Mount... 6 Wiring... 6 Introduction: Four selectable beam frequencies to eliminate interference between multiple units for enhanced perimeter protection. Audible beam alignment (buzzer). Beam strength indicator (5 LEDs). Environmental Output (Selectable N.O. or N.C.): Signal is sent if a degradation in environmental conditions is detected such as thickening fog to prevent false alarms. Built-in heater. Examples of Ways To Connect Sensors... 7 Selectable 4-channel Beam Frequency... 8 Receiver Detail... 8 Beam Alignment Template... 8 Beam Alignment... 9 Adjusting the Delay Time... 10 Testing the Unit... 10 Specifications... 10 Dimensions... 11 Troubleshooting... 11 The ENFORCER E-964-Q Series Quad-Photobeam Sensors are ideal for long-distance protection. Four selectable beam frequencies allow for superior perimeter protection by eliminating crosstalk and interference between multiple units. False alarms created by animals and falling leaves are minimized by the sensor's detection method of all 4 beams simultaneously broken. The E-964-Q Series of sensors is designed to work in even the most extreme conditions. A built-in heater automatically turns on and off depending on the outside temperature. An environmental control output senses a slow degradation in beam strength when weather conditions worsen preventing false alarms. Installation and alignment is quick and easy with the ENFORCER E-964-Q Series. The built-in laser and visual alignment systems quickly and easily pinpoint the approximate mounting location for the transmitter and aid in aligning the transmitter and receiver units once mounted. A beam strength indicator clearly displays the strength of the beam at the receiver with 5 LEDs. IP-55 ingress protection. Lensed optics reinforce beam strength and provide excellent immunity to false alarms due to rain, snow, mist etc. Automatic input power filtering with special noise rejection circuitry. Voltage testing points for fine tuning the beam alignment. Input voltage: -24V AC/DC. Delay time adjustable for nearly all situations. Fig. 15: Dimensions 43ST Pole Size Upper View Side View Troubleshooting: 4 11 /32 (110mm) Front View Rear View Transmitter LED not lit Make sure the input power to the transmitter is to 24 VAC/VDC. Receiver LED does not light when interrupted Check the input power to the receiver is to 24 VAC/VDC. Beams are interrupted and LED lights, but the Check the continuity of the wiring from the alarm does not trigger. receiver to the alarm. Signal LED continuously lit Clear any obstacles between the transmitter and receiver. Clean the lenses of both units. Alarm trigger becomes erratic in bad weather Check overall system installation. Realign the lenses. Frequent false alarm triggers Adjust the response time. Change location of transmitter and receiver. 15 1 /4 (367mm) 4 7 /16 (113mm) 2 11

Adjusting the Delay Time 1. The delay time adjustment knob sets how long the beam can be interrupted before triggering the alarm (see fig. 13): a. A short delay time (high sensitivity) is suitable for catching fast moving intruders, but more susceptible to false alarms. b. A long delay time (low sensitivity) reduces false alarms, but fast moving intruders may not trigger the sensor. 2. Adjust the knob to the site s situation. You may need to make adjustments later after the walk-through test. Testing the Unit 1. Power up the transmitter and receiver. 2. If the red alarm LED remains steady ON even when the beam is not interrupted, re-adjust the alignment. 3. Walk between the transmitter and receiver to interrupt the beams. Walk at various speeds, and adjust the delay time adjustment knob as needed. Fig. 14: Adjusting the Delay Time 50ms (300ms) 700ms NOTE The alarm will be triggered only if both the upper and lower beams are simultaneously interrupted. IMPORTANT Test the detector periodically to ensure the alignment and delay time settings are suitable for the site. Fig. 1: Overview Alignment laser Vertical adjustment screw Green power LED Power ~24V AC/DC Alarm output On/Off switch for laser Viewfinder Horizontal adjustment grip Red signal LED NC/NO switch On/Off Environmental } output Table 4: Specifications Model Max. range (outdoor) Max. range (indoor) Current ( & ) Current ( & & heaters) Input voltage Delay time Detection method Selectable beam frequencies Alarm output Tamper output ( & ) Environmental output Beam-strength indicator Signal LED () Power LED ( & ) Laser wavelength Laser output power Alignment angle Operating temperature Weight Ingress protection Case Dimensions E-964-Q165Q 165' (50m) 330 (100m) 110mA E-964-Q330Q 330 (100m) 660 (200m) 115mA E-964-Q495Q 495 (150m) 990 (300m) 0mA 280mA E-964-Q660Q 660 (200m) 1320 (400m) 5mA 290mA 260mA 270mA ~24 VAC/VDC (non-polarity) 50msec~700msec (variable) All 4 beams simultaneously broken Four (4) channels Form "C" relay COM/N.O./N.C. 1A@5VAC/24VDC NC switch, 1A @ 0VAC Selectable N.O. or N.C. 1A@5VAC/24VDC 5 LEDs indicate signal strength from high to low Red LED ON - beam is broken or and out of alignment Green LED - illuminated when power is on 650nm 5mW Horizontal: ±90 0 Vertical: ±15 0-13~131 0 F (-25 0 ~ 55 0 C) 5.7 lbs. (2.6kg) IP55 PC Resin 15 1 /4" x 4 7 /16" x 4 11 /32" (387 x 113 x 110mm) * This is the minimum time interval between breaking of both beams which will trigger the output. Setting the interval longer will reduce false alarms from birds or falling leaves, etc., while setting it shorter will detect faster moving objects. Beam strength indicator (5 LEDs) Tamper output Voltage output probes Vertical adjustment screw Alignment laser On/Off switch for laser (Receiver shown) Beam channel selection DIP switches Delay time (50ms~700ms) Heater power Environmental output Horizontal adjustment grip Viewfinder for alignment IMPORTANT Do not connect to power until the sensor is completely installed and the installation has been double-checked. 10 3

Fig. 2: Wiring Diagram Receiver Power AC/DC -24V (non-polarity) Alarm O/P 1A @ 5VAC /24VDC N.C. Com N.O. Tamper output N.C. switch 1A @ 30VDC (Max.) 1 2 3 4 5 6 7 Heater Environmental output (NO/NC) 1A @ 5 VAC /24VDC Transmitter Power AC/DC -24V (non-polarity) Tamper output 6 N.C. switch 1A @ 30VDC (Max.) 7 Choosing a Location 1. Find a suitable location for the receiver within wiring distance of a power supply and the alarm panel. 2. Establish a clear line-of-sight area between the receiver location and the transmitter location. 3. Make sure no trees or vegetation will cause false alarms during windy conditions. 4. Find locations away from standing water that could be splashed on to the receiver or the transmitter. 5. Do not mount the receiver where sunlight or bright lights shine directly into the unit. 6. Install at a distance of 32 to 39 (80 to 100 cm) above the ground for most situations. See fig. 3. Running the Cable Run a cable from the alarm control panel to the photobeam sensor. If burying the cable is required, make sure to use electrical conduit. Shielded cable is strongly suggested. See Table 1 for maximum cable length. Table 1: Cable Length Model Wire Size V 24V V 24V V 24V V 24V AWG22 AWG20 AWG18 AWG17 E-964-Q165Q E-964-Q330Q E-964-Q495Q 320m 1,050ft. 550m 1,800ft. 800m 2,600ft. 980m 3,190ft. 2,800m 18,000ft. 4,800m 15,750ft. 7,200m 23,620ft. 8,800m 28,870ft. 280m 920ft. 450m 1,480ft. 700m 2,300ft. 850m 2,790ft. 2,400m 7,870ft. 4,200m 13,780ft. 6,200m 20,340ft. 7,600m 24,930ft. 200m 660ft. 350m 1,150ft. 500m 1,640ft. 590m 1,940ft. 1 2 1,600m 5,250ft. 3,000m 9,840ft. 4,200m 13,780ft. 5,200m 17,060ft. E-964-Q660Q 110m 390ft. 170m 560ft. 250m 820ft. 310m 1,020ft. Heater 900m 2,950ft. 1,400m 4,590ft. 2,200m 7,220ft. 2,600m 8,530ft. Note (1): Max. cable length when two or more sets are connected is the value shown in Table 1 divided by the no. of sets. Beam Alignment Procedure 1. Remove the sensor cover and turn On the top and bottom lasers of both the transmitter and receiver. There are a total of four lasers. 2. Adjust the transmitter's sensor unit vertically and horizontally until the red dot is centered on the receiver and the receiver s signal LED turns Off. 3. Repeat step 2 for the receiver then turn Off the lasers. 4. Look through the viewfinder on the transmitter s lower sensor and adjust it vertically and horizontally until the receiver is clearly seen in the viewfinder. 5. Repeat step 4 for the receiver. 6. Turn On the beam alignment buzzer DIP switch (fig. 9). If the beams are not aligned the buzzer will sound. 7. Cover the top sensor on the receiver with the included template (as shown in fig. 10). Adjust the horizontal angle of the receiver s lower sensor vertically and horizontally until the buzzer stops sounding. Repeat while covering the lower sensor and adjusting the top sensor. 8. Turn the buzzer Off. 9. Turn On the beam strength Indicator DIP switch (fig. 9). If the beams are not aligned, the indicator will display little or no beam strength, see fig.. 10. Cover the top sensor on the receiver. Adjust the horizontal angle of the receiver s lower sensor vertically and horizontally until the beam strength indicator displays a strong signal. Repeat while covering the lower sensor and adjusting the top sensor. 11. Turn the beam strength indicator Off. Fine Tuning The most accurate way to align the transmitter and receiver is to measure the voltage using the voltage output jack. 1. Set the range of a multimeter to 0~10VDC. 2. Insert the red probe into the (+) terminal and the black probe into the (-) terminal. 3. Using Table 3, adjust the receiver s sensors vertically and horizontally until the best possible voltage output is achieved. Fig. 11: Horizontal and Vertical Sensor Adjustment Vertical Adjustment Screw Horizontal Adjustment Finger Grips View Finder The transmitter and receiver sensor units can be adjusted ±15 vertically and ±90 horizontally once the unit is mounted and power is connected. Fig. : Beam Strength Indicator Table. 3: Voltage Output Voltage Output <1.6 1.6~2.0V 2.0~2.4V 2.4~2.8V 2.8~3.2V >3.2V Alignment Quality No Signal Bad Poor OK Good Strongest Strongest Good OK Poor Bad No Signal Fig. 13: Using a Multimeter for Fine Tuning 4 9

Selectable 4-channel beam frequency: The sensor beam frequency can be set at different levels on-site to avoid interference from other photobeam sensors nearby. To select between four different beam frequencies, adjust the beam channel switch of the transmitter side and receiver side. See pg. 3, fig. 1 for switch location and table 2 for switch position. Fig. 9: Receiver Detail Table 2: Channel Beam Frequency Selection Chart Freq. channel CH1 CH2 CH3 CH4 Switch position NO NO NO NO 1 2 1 2 1 2 1 2 Important The transmitter and receiver must be programmed to the same channel. Multiple sensor sample applications 1. Long distance series application. Channel #1 Channel #2 Channel #3 Channel #4 2. Two layer (double stacked) applications. Channel #1 Channel #2 Channel #3 Channel #4 DIP Switch Channel Selector Channel #4 Channel #3 Channel #2 Channel #1 Beam Alignment Buzzer Switch Beam Alignment Strength Indicator Switch 3. Perimeter security application. 4. Single pair multiple layer application. Channel #1 Channel #3 Channel #1 Channel #2 Channel #4 Channel #2 Channel #3 Channel #4 Fig. 10: Included Beam Alignment Template: Use the included SECO-LARM template to aid in aligning the transmitter and receiver. Fig. 3: Typical Installations Side Views 32" to 39" 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Top Views 3 3 3 3 3 3 8 5

Wiring the Transmitter Wall Mount 1. Remove the cover. Remove the screw under the lens unit in order to detach the mounting plate. See fig. 4. 2. If the sensor wiring comes from inside the wall Break a hole in the mounting plate s rubber grommet, and pull the cable through the grommet s hole. Then run the cable through the hole near the bottom of the sensor unit so it comes out the front. Using two of the included mounting screws, attach the mounting plate to the wall. Then reattach the sensor unit to the mounting plate, connect the wires, and snap on the cover. See fig. 5. 3. If the sensor wiring is run along the surface of the wall There are four plastic knockouts on the back of the sensor unit, two on top and two on bottom. Break out the appropriate knockout, and pull the wiring through the knockout. Then run the wiring through the hole near the bottom of the sensor unit so it comes out the front. Using two of the included mounting screws, attach the mounting plate to the wall. Then reattach the sensor unit to the mounting plate, connect the wires, and snap on the cover. See fig. 6. Wiring the Transmitter Pole Mount (NOTE Pole mounting bracket included.) 1. Remove the cover. Remove the screw under the lens unit in order to detach the mounting plate. See fig. 4. 2. Break a hole in the mounting plate s rubber grommet, and pull the cable through the grommet s hole. Then run the cable through the hole near the bottom of the sensor unit so it comes out the front. Use the included mounting bracket to mount to the pole. Then reattach the sensor unit to the mounting plate, connect the wires, and snap on the cover. See fig. 7. Wiring (fig. 8) 1. Screw the wires tightly to avoid slipping off the terminals, but not so tight that they break. 2. Screws on terminals which are not used should be tightened. 3. Grounding may be necessary, depending on the location. Fig. 4: Remove the Transmitter cover Fig. 5: Wall Mount, Wire from Inside Wall Fig. 6: Wall Mount, Wire Runs Along Wall Fig. 7: Pole Mount or Fig. 8: Examples of Possible Ways To Connect One or More Sensors Example connection 1 - Standard Example connection 2 - In-line Single Channel Example connection 3 - Dual Sensors, Separate Channels Example connection 4 - Two stacked Ch1 Ch2 Ch1 Ch2 } N.C. Alarm signal (~24VAC/VDC) } N.C. Alarm signal (~24VAC/VDC) } N.C. Alarm (ch. 1) } N.C. Alarm (ch. 2) (~24VAC/VDC) }Alarm signal (~24VAC/VDC) 6 7