Fluid Cooler Fan and Pump control panel

Similar documents
Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Marley Collection Basin Heater Circuit

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

/ Marley Collection Basin Heater / User Manual

ABH basin heater control

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Wiring Diagrams DIAGRAM INDEX

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

SIMPLEX WEATHERPROOF CONTROL PANELS

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Schneider Electric Erie T155 Series

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Wiring Diagrams Units Produced After April 20, 2009

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Emerson Blue Easy Set 1H/1C

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

T-Series Air Conditioner T15 Model

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

MULTI-STAGE CHILLER CONTROL

Installation Instructions

Field Start-Up Sheet Direct Fired Gas Equipment

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Installation Instructions

MODEL MW200 MODEL MW600 AIR DRYER

HD3D Forced-Air Heater

Unipower HPL420. User s Manual. True Motor Power Monitor with... Typical Applications. High Trip Alarm. Low Trip Alarm.

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

CHILLER. Model CH3000. Operator s & Installation Manual

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

CommStat 4 Controller

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

TM Series. Induced Draft, Counter Flow Optional Accessories

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

FPC-02 Series. Installation and Operating manual

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Demand Duo Principle of Operation:

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

ULTRA-SAFE Explosion-proof Duct Heaters

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Gate Operator. Modfications

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Smart Temp. ApolloP/n Installation Manual. Version 1.0

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

SAFETY INFORMATION AND WARNINGS

T-Series Air Conditioner T20 Model

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

ULTRA-SAFE Explosion-proof Duct Heaters

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

LZP-2 ZONE CONTROL PANEL

DISPOSER CONTROL CENTER

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

INSTALLATION INSTRUCTIONS

Tri-Stack Smart System

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Two-Position Electric Duplex Room Thermostats

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Safety & Installation Instructions

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

PARAGON Commercial Refrigeration Controls

Transcription:

user manual Fluid Cooler Fan and Pump control panel INSTALLATION - OPERATION - MAINTENANCE Z02819_A M03-171B ISSUED 07/2014 0/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR OR SERVICING THIS THIS PRODUCT.

introduction 2 NEMA 4X fiberglass outdoor enclosure with the following features: Hinged and lockable outer door Swing-out dead front inner door Corrosion resistant enclosure Operators mounted on inner door Electrical Components External disconnect handle with padlocking provisions to meet lockout, tag-out safety requirements Main circuit breaker with thermal and magnetic overload protection Solid-state temperature controller with two-line display showing setpoint and coil fluid temperature RTD with dry well Pilot lights Fan and pump starter Status contacts Wiring diagram laminated and mounted on inside door Built to UL08 and CUL08 safety requirements Options: Single Point Power Connection Integrated basin heater controls Integrated water level controls Integrated damper power circuit VFD feeder breaker if fan is controlled with remote VFD Factory installed and wired on selected products

introduction These instructions are intended to assure that field connections are completed properly and the control system operates for the maximum time possible. Since product warranty may depend on your actions, please read these instructions thoroughly prior to operation. If you have questions about the operation and/or maintenance of this control system and you do not find the answers in this manual, please contact your Marley sales representative. Warning Hazard of electrical shock or burn. Be sure to turn off power to the panel before servicing. If working on equipment out of site of panel disconnect, lockout using standard lockout procedure. Safety First The Marley control system uses UL listed components installed in accordance with the National Electric Code. The location of the cooling product and field installation of the control system can affect the safety of those responsible for installing, operating or maintaining the tower and controls. However, since SPX Cooling Technologies does not control the fluid cooler location, or field installation, we cannot be responsible for addressing safety issues that are affected by these items. Warning Warning The following safety issues should be addressed by those responsible for installation, maintenance or repair of the tower and controls: Access to and from the control panel (including the customer supplied main disconnect/branch circuit protection.) Proper grounding of electrical control circuits. Sizing and protection of branch circuits feeding the control panel. Qualification of persons who will install, maintain and service the electrical equipment. These are only some of the safety issues that may arise in the design and installation process. SPX Cooling Technologies strongly recommends that you consult a safety engineer to be sure that all safety considerations have been addressed. Other safety issues are addressed in literature supplied with your cooling product. You should closely review the literature prior to installing, maintaining or repairing your cooling product. 3

installation Note The control panel may be mounted indoors or outdoors. Inside the control panel are steel mounting feet which may be bolted into the enclosure mounting holes and extend beyond the outside dimensions of the enclosure. Locate all incoming and outgoing terminations in the bottom of the enclosure to avoid water entering the control panel. Install the Marley RTD in the discharge piping coming from the coil discharge. Do not install the RTD in the fluid cooler coil piping. Locate the RTD close to the fluid cooler to avoid building in a delayed reaction time. The dry well is furnished with a ½ NPT stainless steel fitting. Insertion length is 2½ or less into the pipe depending on pipe fitting. Locate the dry well in the side or bottom of the pipe to assure the tip of the dry well is covered with fluid at all times. Run control wiring from the RTD to terminal points located in the control panel. Belden # 8770 wire is recommended. RTD SENSOR FLUID RETURN LINE THERMOWELL 1/2" NPT COUPLING SENSOR WIRING RTD Temperature Controller located in CoolBoost panel Belden #8770 3-wire plus Shield 4

installation Circulating Pump Circuits The circulating pump circuit utilizes two safety circuits to protect the pump, a low water shut off and freezing water shut off. These circuits are furnished as standard on every fluid cooler. A dedicated stilling chamber with one reference probe and one level probe is furnished in the cold water basin serving as water level feedback for the low water safety circuit. An optional second stilling chamber may be furnished with additional level probes but services a different purpose such as water make up and alarm. Connect the two low water probes located in the basin stilling chamber to user terminal points in the CoolBoost control panel. Marley probes are furnished with 20'-0" leads which may be lengthened by splicing 18 gauge control wiring. Refer to the wiring diagram in the CoolBoost control panel for connection points. Stilling Chamber Water Level Probes Water Level Card

installation For the freeze safety circuit run two 18 gauge control wires from the thermostat located on the fluid cooler side casing to user terminal points in the CoolBoost control panel. The thermostat has two sets of terminal points. Use either the left or right two points oriented in a vertical column. Note Adjust the temperature range so the red arrow on the left points to 3 F as shown below. The thermostat, provided with this system, requires adjustment. Remove the inner most brass fitting located on the thermostat enclosure to gain access to the adjusting screw. Adjust cut-out set point temperature to 4 F. This automatically sets the cut-in point at 3 F. THERMOSTAT PROBE Thermostat Installed on Casing Thermostat and Probe Use this Adjustment Screw N.O. Contact Set at 3 F THERMOSTAT PROBE Thermostat Probe Installation Thermostat

operation Main circuit breaker: Operating handle for the main breaker is located behind the outer door which is pad-lockable for lock out/tag out. Rotating the handle to the OFF position turns power off to the panel. Rotating the handle to the ON position provides power to the control panel. If servicing the panel hot (door open and main breaker in energized position) be sure to align the keyed slot on back of the operating handle with the key on the main breaker shaft before closing the door. Power ON light: A pilot light indicates the main disconnect is on and the control panel is powered. Fan circuit: Full voltage across the line starter. Bi-metal type motor overload protection. H-O-A selector switch control. Solid state PI type temperature controller. Dual display on the Pi temperature controller shows process fluid (PV) and set point (SP) temperatures. Set point temperature is adjustable from the controller s keypad by pressing the up and down arrows on the keypad. RTD with dry well used to sense temperature for the temperature controller. User terminal points for vibration switch shut down circuit. Fan Operation: Program the temperature controller with the required set point value. 8 F is the factory default and may be field adjusted. On the Love Controls series 1B controller press UP or DOWN arrow button to adjust the set point temperature. The display will revert to the normal screen within 30 seconds. HAND position - With the selector switch in HAND the fan motor will energize and will run at a constant full speed. The HAND position may be used to bump the motor to check fan rotation or manual motor operation. OFF position Fan motor will be de-energized AUTO position In AUTO position the temperature controller controls the ON and OFF cycling of the fan motor. The temperature controller compares the error difference between the discharge fluid measurement by the RTD and the set point value making the decision to turn the fan motor on or off. 7

operation Temperature Controller Information Solid State Temperature Control for one and two speed control panels Temperature Controller: Love Control cat # 1B-33 controller RTD: Marley item # D3728 RTD 3 wire PT100 Love solid state temperature controller using an RTD to measure cold water discharge temperature providing ON-OFF starter control. The Love 1B-33 temperature controller furnished in this control panel has been preprogrammed as follows. Marley CoolBoost Programming Parameters: Single speed motor programming: Primary menu: SV = 8Push (enter) for 3 sec. CnPt = Pt (enter) push index tpun = F (enter) push index tp-h = 300 (enter) push index tp-l = 0 (enter) push index CtrL = onof (enter) push index S-HC = Cool (enter) push index ALA1 = (enter) push index ALA2 = 7 (enter) push index ALA3 = 11 (enter) push index SALA = off (enter) push index CosH = off Ignore everything below CosH Push (enter) twice Cts =.0 (enter) push index tpof = 0.0 (enter) push index Push (enter) Push index 8

operation r-s = run (enter) push index SP =0 (enter) push index AL1H = 110 (enter) push index AL2L = 43 (enter) push index AL3H = 13 (enter) push index AL3L = 8 (enter) push index LoC = LoC2 Push (enter) These settings yield the following operation: Single speed motor programming: Low speed ON at 90 F (Setpt 1 / Output A) Low speed OFF at 8 F (Setpt 1 / Output A) Alarm ON above 110 F and below 43(AL1) Note: Out put #2 is programmed but not used for 1S1W motor. Two speed motor programming: Low speed ON at 90 F (Setpt 1 / Output A) High speed ON at 99 F (Setpt 2 / Output B) High speed OFF at 93 F (Setpt 2 / Output B) Low speed OFF at 8 F (Setpt 1 / Output A) Alarm ON above 110 F and below 43 (AL1) Note Setpoint 2 is a deviation of Setpoint 1, so the actual ON and OFF points will change when Setpoint 1 is changed. 9

operation Pump Operation Caution Standard operation of the pump is by manual control only, using a two-position selector switch located on the door. A removable run enable jumper is provided so customer may take control of cycling the pump. See the control panel wiring diagram. Cycling the pump on and off for temperature control could cause scaling on the coils and is not recommended. OFF-ON Selector Switch OFF position pump motor is off. ON position pump motor will run constantly unless a safety circuit is activated. If the water temperature in the cold water basin drops to 3 F a N.O. contact from the remote thermostat will close and latch-in a relay, which in turn shuts off the circulating pump. This is a safety circuit to prevent pumping freezing water. To reset this circuit, press the reset button on the door. The circuit can be only reset once the cold water basin temperature rises above 4 F. If the basin water drops to a dangerously low level, the water level card contact will close and also energize the latch-in relay shutting the circulating pump off. This is a safety circuit preventing the pump from running dry. To reset this circuit, press the reset button on the door. The circuit can only be reset if the water in the basin has risen to an acceptable operating level. 10

options Integrated Basin Heater Control Circuit Note This circuit monitors the water temperature in the cold water basin via a probe type sensor mounted through the side wall of the cold water basin. The temperature probe is furnished with 22 feet of lead length. Longer lead lengths up to 99 feet are available. Do not add wiring to the probe lead. The solid state control card is located inside the CoolBoost control panel. A power contactor inside the control panel is used to energize the heating element. Sensor Probe with 22 foot lead Basin Heater Card The temperature card and basin heater element maintains water temperature in the basin between 40 F and 4 F. The temperature probe includes a low water cut off circuit. If the water level falls below the temperature probe the basin heater contactor will not energize. 11

options Solid State Water Level Control and Alarm Circuit The number of probes depends on the number of optional circuits being furnished. Each water level event requires one card. The card includes an on-board relay with (1) form C dry contact. Contacts are wired to a user Stilling Chamber Water Level Probes Water Level Card terminal strip for connection to remote devices such as makeup solenoids and alarms. Water make-up control Form C 1- N.O. 1 N.C. contact wired to 120 VAC fused circuit for customer use to power a remote solenoid. High water alarm - N.O. contact wired to user terminal block Low water alarm - N.O. contact wired to user terminal block High water cutoff N.C. contact wired to user terminal block Low water cutoff - N.C. contact wired to user terminal block Pump Heat Trace If circulation pump is has the heat trace option connect the heat trace tape back to the CoolBoost control panel. 12

options Damper Local Control Circuit 120VAC FUSE CLOSE OPEN AUTO DAMPER MOTOR OPEN XOO OXO M1-2 CLOSED OOX M1-3 CUSTOMER CONNECTION FAN CONTACTOR AUXILLARY CONTACTS This circuit is furnished when a damper control option is ordered and the damper circuit is controlled from the CoolBoost panel in coordination with the fan starter. The panel is furnished with a 120 VAC circuit for powering the damper actuator motor. Three wires and a ground are required between the control panel and the damper motor. 120 VAC power for the actuator motor on the damper is brought out to user terminal points inside the panel. Operation: The damper will open when the fan motor is energized and will close when the fan motor is off. H-O-A selector switch operation: HAND position: OFF position: AUTOMATIC position: Damper opens Damper closes Damper is closed when fan is off 13

14 Typical Schematic Showing Options

CB AMPS L1 VOLTS L2 PHASE HERTZ L3 SUPPLY 480 VOLTS FNQR 2 FNQR 2 GROUND H1 H3 H2 H4 120 VOLTS FNM 4 X1 X2 FU 3 OFF VIB. SW. OL 7 HAND AUTO 9 10 F1 FAN STARTER XOO (9) (9) 1 REMOTE ENABLE 2 (1) (2) OOX PURPLE JUMPER (7) (8) 10 TEMPERATURE CONTROLLER (11) (12) 120 COM INDEECO HEATER CONTROL CARD N NO NC C1 C2 F1 29 30 C1 (A1) (A2) BASIN HEATER CONTROLLER BASIN HEATER CONTACTOR G1 G2 T2 T1 SH C2 C1 BASIN HEATER ON LIGHT 10 11 0W STRIP HEATER FNM 1 1/4 A FU 120V FOR CUSTOMER USE 1 2 3 4 7 8 9 8 7 B FU 1 FU 2 INCOMING LINE POWER 300 VA PUMP 1 HEAT TRACING (SELF REGULATING) FNM 1 P1HT 3 FU 4 PUMP 1 HEAT TRACE DAMPER HEATER FNM 1 1/4 DH 3 FU DAMPER HEATER 19 20 XOO 21 22 OOX TEMPERATURE CONTROLLER F1 LOW ALARM 17 (97) (98) R FAN O.L. TRIP CR3 (13) (14) FAN O.L. TRIP RELAY TEMPERATURE / LEVEL PROBE IN WATER BASIN 11 Continued On Page 2 TR2 (2) (7) 2 SEC DELAY FAULT TIMER CR2-1 (9) () JOHNSON CONTROLS LOW TEMP ALARM RESET 3 37 R TR2-1 (1) (3) 38 CR2 (13) (14) PUMP SAFETY CIRCUT SHUT DOWN LIGHT PUMP SAFETY CIRCUT SHUT DOWN RELAY "A" N CIRC. PUMP CUT-OFF 19B BLUE WIRE CARD HI COM LO CIRC. PUMP CUT-OFF NO 13B BLUE WIRE RELAY 3 COM LLC24A2F0N NC OFF ON CR2-2 39 40 OX (10) (2) PURPLE JUMPER 41 P1 (A1) (A2) 42 P1 OL (9) (9) WATER PUMP 1 43 44 10 PUMP 1 RUNNING OX B LIGHT CR (13) (14) PUMP 1 OVERLOAD TRIP RELAY P1 ALARM 4 PUMP 1 R OVERLOAD (97) (98) TRIP LIGHT CR (13) (14) DAMPER OPEN LIGHT CLOSE B FNM 1 1/4 4 OPEN AUTO 47 FU 7 OPEN XOO DAMPER 48 CONTROL CLOSED OXO DAMPER CONTROL 49 F1 OOX F1 TEMPERATURE CONTROLLER RTD CONNECTION CONNECTION Red CBL1 BLK (4) Wht Red RED () WHT (3) S Marley CoolBoost Fan and Pump Panel Options: Basin Heater Control Ciruit Typical wiring diagram. Not to be used for construction. See as built wiring diagrams for specific projects. 3 B 4 3 1 3 L 1

CB AMPS L1 CONTINUED FROM VOLTS L2 PAGE 1 PHASE HERTZ L3 SUPPLY GROUND F1 F1 F1 OVERLOAD RELAY LOAD POWER TERMINAL TORQUE 12.39 IN/LBS. T2 T1 T3 8 MOTOR FAN MOTOR #1 2 HP 29. FLA 480 VOLTS GROUND LOAD POWER TERMINAL TORQUE 12.39 IN/LBS. T2 T1 T3 8 GROUND MOTOR PUMP MOTOR #1 HP 7. FLA 480 VOLTS FNQR 8 FU 8 FNQR 8 FU 9 FNQR 8 FU 10 23 F1 24 3 20 AMPS. T1N020TL P1 P1 P1 P1 C1 C1 4 LOAD POWER OVERLOAD RELAY TERMINAL TORQUE 12.39 IN/LBS. CANDO Control Panel Two Speed, One Winding, Three Phase Note: 1 Terminal point number on terminal block 2 ( ) Indicates actual markings on device 3 Remote located equipment 4 Field wiring by others. USE COPPER WIRE ONLY. Jumper must be removed when vibration switch is used. Set high and low overload amperage to motor nameplate. Remove purple jumper when adding heater cut off. Incoming power wire rating: 0 degrees celcius. Field wire: 1 AWG. 10 Remove purple jumper when remote enable is used. 11 C1 & C2 connects to thermal cut off basin heater element. C1 C1 C1 Heater Element KW 19 FLA 480 VOLTS Optional Basin Heater Power Circuit PUMP SAFETY CUT-OFF STATUS CONTACT 7 CR2-4 8 (12) (8) FAN O.L. STATUS CONTACT 9 CR3-1 0 (9) () PUMP 1 O.L. STATUS CONTACT 1 CR-1 2 (9) () DAMPER OPEN STATUS CONTACT 3 CR-1 4 (9) () Marley CoolBoost Fan and Pump Panel Optional Basin Heater Control Cirucit Typical wiring diagram. Not to be used for construction. See as built wiring diagrams for specific projects. TERMINAL STRIP 120V 0VA SUPPLY FOR CUSTOMER USE FACTOR JUMPER VIBRATION SWITCH JUMPER FIELD WIRE TERMINAL 10 POINT TORQUE:18IN./LBS. 12 FAN REMOTE ENABLE 1 FAN LOW OVERLOAD 17 19-20 FAN IN HAND DRY CONTACT 19 19-20 FAN IN HAND DRY CONTACT 20 21-22 FAN IN AUTO DRY CONTACT 21 21-22 FAN IN AUTO DRY CONTACT 22 23-24 FAN RUNNING 23 23-24 FAN RUNNING 24 FAN REMOTE ENABLE 2 HEATER REMOTE ENABLE 29 HEATER REMOTE ENABLE 30 3 37 39 PUMP 1 REMOTE ENABLE 40 PUMP 1 REMOTE ENABLE 41 42 43-44 PUMP 1 SEL. SW. ON 43 43-44 PUMP 1 SEL. SW. ON 44 4 4 47 48 49 3-4 PUMP 1 CONTACTOR ON 3 3-4 PUMP 1 CONTACTOR ON 4 - HEATER CONTACTOR ON - HEATER CONTACTOR ON 7-8 PUMP SAFETY DRY CONTACT 7 7-8 PUMP SAFETY DRY CONTACT 8 9-0 FAN O.L. DRY CONTACT 9 9-0 FAN O.L. DRY CONTACT 0 1-2 PUMP 1 O.L. DRY CONTACT 1 1-2 PUMP 1 O.L. DRY CONTACT 2 3-4 DAMPER OPEN DRY CONTACT 3 3-4 DAMPER OPEN DRY CONTACT 4 DAMPER HEATER HOT WIRE DH HEAT TRACE HOT WIRE P1HT RTD CONTACT RTD CONTACT RTD CONTACT RTD SHIELD C1-C2 THERMAL CUT OFF C1-C2 THERMAL CUT OFF S C1 C2 7 8 9 9 7 9 4 1 3 1

troubleshooting Trouble Cause Remedy Control Power No power ON light Fan Motor Power Light is ON but the fan motor(s) will not operate in the HAND position. Fan Motor Power Light is ON but the fan motor(s) will not operate in the AUTO position only. Pump Motor When the pump switch is turned to the ON position, the circulating pump motor will not run. Integrated Basin Heater Control Option Basin heater control is not turning on. Heater element(s) in the cold water basin are not heating the water. Integrated Damper Control Option Damper switch will not manually open or close the damper. Integrated Damper Control Option Damper will open and close manually but will not open in AUTO. Fan motor ALARM LIGHTS Pump motor ALARM LIGHTS Main disconnect OFF Blown fuse(s) Vibration switch, external safeties, or run permission contacts are inhibiting closure of the fan motor contactor (open circuit between terminals and 7). Fan motor OL (Over-Load) tripped. Set point temperature programmed into the temperature controller is higher then the actual temperature of the fluid in the coil therefore there is no call for cooling. Temperature controller indicates an alarm. (Amber AL)** Temperature controller is not functioning properly. Pump motor OL. (Over-Load) tripped. Tripped circuit breaker for pump motor supply voltage. The pump alarm light has energized. The pump alarm light has energized. Water temperature is above 4 F. The fan motor is running. Blown fuse(s). Heater Control circuit card or heater elements not functioning correctly. Blown fuse. Fan motor is not running. Fan motor OL (Over-Load) tripped. Pump motor OL (Over-Load) tripped. Make sure main disconnect switch is in the ON position Check primary and secondary fuses for the control supply voltage located on top of the control power transformer. Check incoming Line Voltage fuses. (replace fuses as necessary.) Reset vibration limit switch and/or verify customer start inhibit does not exist. (e.g. Building automation, Emergency Stop) Verify the OLs sized correctly. (heater size or dial setting.) Reset motor OL. To reset OLs, sufficient time must elapse to cool the bi-metal OL heaters.* Lower the set point value in the controller Program controller to an appropriate alarm setting.** Then, press reset button located on the front door of the control panel. First, verify the controller is not in a fault condition, that the setpoint of the controller is accurately programmed, and the fluid being cooled has reached the temperature required to run the fan motors. Then using a voltage meter, check for 120VAC being present between terminals 1 and. Then check for 120VAC between terminals 9 and. If voltage exists between 1 and and not between 9 and call for assistance to replace the PI controller. Verify the OLs sized correctly. (dial setting) Reset motor OL. To reset OLs, sufficient time must elapse to cool the bi-metal OL heaters.** Reset the circuit breaker Make appropriate adjustments to insure basin water level meets requirements. Once basin water has reached its required level press the alarm reset located on the front of the control panel. Make appropriate adjustments to insure basin water temperature meets requirements. Once basin water has reached its required temperature press the alarm reset located on the front of the control panel. The water temperature must drop to 4 F before the basin heater circuit will energize the heater contactor. Once the contactor is energized, the heater(s) will remain on until the temperature is above 0 F. The heater contactor circuit is designed not to energize the heater elements while the fan motor is running. If the fan motor is running and the basin cold water temperature is below 4 F. Check the voltage supply fuses to the heating elements. (replace fuses as necessary.) If the fan motor is running and the basin cold water temperature is below 4 F. Call for troubleshooting assistance in determining if replacement of heater control card or heater element is necessary. If by switching the OPEN, OFF, AUTO selector between OPEN and OFF does not change the position of the damper. Check FU3 fuse which supplies the damper control circuit. (replace blown fuse.) To check AUTO operation of the damper control, the fan motor must be running. When fan is running, dampers should open. When fan is off, dampers should close. Check for correct wiring at the damper logic contacts. Verify the OLs sized correctly. (dial setting.) Reset motor OL. To reset OLs, sufficient time must elapse to cool the bi-metal OL heaters.* Verify the OLs sized correctly. (dial setting.) Reset motor OL. To reset OLs, sufficient time must elapse to cool the bi-metal OL heaters.* * Over Load tripping is caused by excessive motor current. Frequent and continued tripping indicates possible motor and or mechanical operation problems. Troubleshooting procedures must be performed on these associated components to determine the cause of the over current condition. ** The alarm setting on the temperature controller has been factory preset at 40 F. A differential exists between the when alarm is activated and when a reset is accepted. For example if the programmed alarm temperature is reached, the fluid temperature would need to rise an additional in order to reset the controller (if set at 40, it must rise above 4 ). 17

Fluid Cooler Fan and Pump control panel USER MANUAL SPX COOLING TECHNOLOGIES, INC. 7401 WEST 129 STREET OVERLAND PARK, KS 213 USA 913 4 7400 spxcooling@spx.com spxcooling.com Z02819_A (09-138) ISSUED 0/2017 COPYRIGHT 2017 SPX CORPORATION In the interest of technological progress, all products are subject to design and/or material change without notice.