KONE AMD Doors and Entrances. Architectural design Information

Similar documents
KONE Corporation

KONE Design signalization

KONE DESIGN SIGNALIZATION. KSS D20, KSS D50 and KSS D60 series

MATERIALS AND ACCESSORIES

Under construction. KDS D20 and KDS D40. KONE Design signalization

The heart of your building. KONE Deco Design

MATERIALS AND ACCESSORIES

MATERIALS AND ACCESSORIES. KONE Design Collection. N MonoSpace and S MonoSpace

Pedestrian Swing and sliding doors. Accessories

Port of Portland Conveying Equipment Guidelines

ORIGINAL RENDERING 1814 FRANKLIN STREET OAKLAND, CALIFORNIA 80 S MODIFICATIONS PROPOSED ELEVATION COVER THE LEAMINGTON architecture & interiors experi

CITY HISTORIC ZONING COMMISSION STAFF REPORT - CERTIFICATE OF APPROPRIATENESS APPLICATION

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

MATERIALS AND ACCESSORIES

Passenger Lifts: finishes & options. A guide to the wide variety of finishes and options available on our passenger lifts

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

Bethlehem University 2008 Projects Summary

4. Name the room designed specifically for washing, drying, folding, and ironing clothes.

STOREFRONT DESIGN CRITERIA MANUAL

Schindler HXpress An efficient, affordable modernization for hydraulic elevators

CHAPTER 10 GC GENERAL COMMERCIAL DISTRICT

MIDTOWN MIXED-USE VILLAGE. TECHNICAL DATA SHEET COMPONENT C-1 FOR PUBLIC HEARING - PETITION NUMBER Project No RZ1.1. Issued.

Ambleside Gardens, Lowestoft, NR32 4GN 305,000

MAXIMIZE YOUR STORE POTENTIAL

Where do you go from here?

Knauf Direct Bonding and Metal Furring

Move In Report. Report Information

Car Design. Contents. Design. Car. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors. Ceiling Variation & Car Finish 3-10

WATEROAK DRIVE. LOT 30 - The Maddox FLOOR PLANS / 40 FRONT / SINGLE DETACHED / 4 BEDROOMS / 2802 SQFT

Shutters Measuring and Ordering Guide

Walnut Creek Transit Village Design Guidelines. Part Three III - 25

L 4-1. Heritage Report: Reasons for Heritage Designation. Kodors House. 35 Rosedale Avenue West

CHAPTER 11 HC HIGHWAY COMMERCIAL DISTRICT

Scope of Work - Single Family Home, El Cajon, CA

ELEVATORS AND FIRE SERVICE. CODE CHANGES in. Presenter: Eric Peterson, P. Eng.

SIGMA MRL E1000.

[Lighting Proposal Memo ] Hotel and Conference Center Virginia, USA

Higher Education. World-class faculties deserve world-class spaces... Discover faculty solutions that combine status with functionality.

LUMISPLASH. Decorative laminates with LED edge lighting incorporated in an ultra-thin panel. ATILaminates.com/LumiSplash

DIVISION 14 - CONVEYING SYSTEMS. 1. Passenger Elevators 2. Vertical Platform and Inclined Wheelchair Lifts.

SITE PLANNING. USC Village will be a mixeduse urban environment. creating a common ground with the surrounding community. Our planning goals include:

Introduction Limited-Use / Limited-Application

Description of pic to go here

Design Series. Windows. inspired by you. ALUMINUM-CLAD VINYL

Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT

FAÇADE DESIGN GUIDE. A Placemaking Initiative of the City of Richmond Department of Planning & Development Review

Interfacing Fire Alarm, Sprinkler and Elevator Systems

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL Only. Materials and Colors

本カタログのオリジナル版は 中文版です 本英語版PDFは ELENESSA

Contents. Principle. Ceiling Design Signal Fixtures. Interior. Hall Design. Observation Cars NEXIEZ - MRL only. Materials and Colors

Vanilla Box Design Criteria

Building and Site Design Standards

MAY 2016 Elevator QEI & Maintenance Performance Report

SECTION ELECTRIC TRACTION ELEVATORS PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: Electric Traction Elevators.

APPENDIX MATAKANA COMMERCIAL URBAN DESIGN GUIDELINES

Atkins Hall (Building 31)

Automatic swing door solutions. We make access in life smart and secure.

Inde-Pendants Family. 32L Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

GUIDELINES TORONTO GENERAL HOSPITAL LOCATION. INTRODUCTION Existing College Wing Buildings and Site Plan - Figure 1A and Figure 1B.

Figure 41. Spermaceti Cove Life-Saving Station, south and east elevations.

Automated Entrance Accessories. ADA compliant door control without compromise

Heritage Designation Brief. Bonner Worth Mill: Administration Building

A NEIGHBORHOOD BY TRI POINTE HOMES

2007 Elevator Cab Workbook. ThyssenKrupp Elevator Americas Business Unit

PASSENGER ELEVATORS Series-MR

Lighting Existing Conditions and Design Criteria Report

498 E. Bellevue Avenue Reading, PA 19601

Your Home, Your Township, Your Paradise

Contact details Snowshill, near Broadway, Gloucestershire, WR12 7JU T: E:

Bel-Air Lexus Automobile Service Station

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

TOWNHOME STANDARD INCLUSIONS

RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators

Beaufort County Community College. Maintenance and House Keeping Plan

Higher Kinnerton, Chester, Flintshire CH4 9AJ

Chapter 11. Exterior Design Factors. Introduction. House design does not stop once room arrangements are determined

Contact details Kedleston Hall, Derby DE22 5JH T: E: Points to note. Arrival & Parking Facilities

Residential Sound Insulation Program Historic Homes Pilot Program. October 21, 2015

RHBL 7325 ENVIRONMENTAL ANALYSIS. By: Whitney Musick

Location and lifestyle meet in this great townhome by Domicile, located on a quiet cul-de-sac just steps from Parkdale Market, the Ottawa River,

A New Lifestyle You Never Dreamed Possible

Bridgefoot Cottages. Stedham, Midhurst, West Sussex

Mableton Parkway & Veterans Memorial Highway Design Guidelines

CHAPTER 6 DESIGN GUIDELINES FOR INDIVIDUAL BUILDING ELEMENTS. Commercial Facades

Plastic Lobby Dust Pan. Metal Lobby Dust Pan - Black CODE: CN Metal Dust Pan- Black CODE: CN912

A Program Summary: Program components include a 234-room boutique hotel, bar, restaurant, meeting spaces, and retail.

MULTIFAMILY RESIDENTIAL DESIGN PRINCIPLES Site Plan and Design Review Principles Checklist

Exterior Trim (2009 to Present)

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

PLANNING COMMISSION AGENDA REPORT NOVEMBER 15, 2012

Hardscape & Landscape

Landscaping And Site Details

TENANCY DESIGN REVIEW PROCESS GUIDE

Pont-yr-Uchen Farm Tal-y-Coed, Monmouth

A PRICOL PROPERTY PRISTINE LUXURY RESIDENCES

RESIDENTIAL ELEVATORS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION ELEVATORS

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Modern Exteriors Stylish Kitchens Designer Bathrooms Comtemporary Living Fixtures & Finishes Schedule Inclusions Brochure

Transcription:

KONE AMD Doors and Entrances Architectural design Information

KONE AMD Doors and Entrances Door configurations The design of elevator doors and their surroundings is challenging: Smooth operation of the doors is important in the flow of passenger traffic. Fast, reliable and quiet doors minimize waiting time and improve convenience. KONE AMD-1 Two panel centre opening AMD-1 door configuration is the most traffic-efficient, allowing exit and entry even before the doors are fully open. The entrances must provide the passengers with safe, easy and convenient access to the elevators and landing fixtures. Elevator, lobby, and entrance design has to meet both aesthetical and functional requirements. The entrances form the structural interface between the building and the elevator, and channel the passengers between the landings and the elevator cars. KONE AMD-2 AMD-2 is a two panel side opening door. This configuration saves space and shaft width but is not as efficient operationally as centre opening door. The KONE AMD doors are designed and engineered to meet these demands, combining safety, performance, durability and attractive styling. For large cars or special applications four and six panel centre opening types are available Right: Centre opening AMD1 door with Frame entrance, plaster walls, KONE Sigma landing fixtures.

Narrow Frame Entrance The 50 mm wide Narrow Frame reduces the visual impact of the landing entrance, helping to blend it with the lobby design. The entrance jambs can be finished either in the wall finish or in the door panel material. The flush or surface mounted landing fixtures are fixed to the wall. Left: Centre opening AMD1 door, Narrow Frame entrance, wall and floor finished in stone, Delta ThinLine landing fixtures Below: Centre opening AMD-1 door, Narrow Frame entrance, wall and floor finished in stone, Oval Delta FlushLine landing fixtures Right: Side opening AMD-2 door, Narrow Frame entrance with custom architrave, oiled and lacquered plywood walls with aluminum strips, stone floor, Delta ThinLine landing fixtures by separate agreement

Frame Entrance The 150mm wide Frame entrance is an economical and attractive solution. The door jambs are finished in the same material as the door panel, and the flush or surface mounted landing fixtures are built into the door frame to reduce the need for extra finishing work. Left: Side opening AMD-2 doors, Frame entrance, plaster walls, plastic tile flooring, Sigma landing fixtures Right: Centre opening AMD-1 door, Frame entrance, Sigma landing fixtures Below: Side opening AMD-2 door, Frame entrance, Sigma Landing fixtures

Full Front Entrance The Full Front entrance minimizes any extra finishing work it covers the full height and width of the hoistway, allowing quick completion of landings. The flush or surface mounted landing fixtures are built into the front. Glass Doors As an optional feature in lobby design the KONE AMD door family includes glass door panels. Left: Centre opening AMD1 door with Full Front entrance in patterned stainless steel, glass clad brick wall, Delta ThinLine landing fixtures Right: Centre opening AMD1 door with glass panels, Narrow Frame entrance, wall and floor finished in stone, Delta ThinLine landing fixtures.

Custom built entrances Kone KONE AMD doors and entrances provide a wide range of alternatives that offer the maximum flexibility in the innovative design of entrances and lobbies.

Entrance facades Design 1 Design 2 D-D HH HA HB HR A A HH HA HR LA LL LA LA LL LA LL = clear opening width 600 (frame) 700 (frame or front) 800 (frame or front) 900 (frame or front) 1000 (frame) 1100 (frame) HH = clear height in door entrance 2000, 2100 LA = uprights width 150 (frame) LL/2+70 (front) LB = side opening door slam post width 150 (frame) 170 (front) 220 (front) 270 (front) HA = lintel height 195 270 370 470 HB = top extension panel 200 300 400 500 HR = raw opening height 2225 2300 2400 2500 2600 2700 2800 2900 3000 Frame Front with extended top Front with MonoSpace control cabinet (top floor only) Frame A-A Front Frame with MonoSpace control cabinet (top floor only) B B LL = clear opening width 800 1500 HH = clear height in door entrance 1900 2900 LA = uprights width 50 (narrow frame) 150 (frame) LL/2+70 (front) LB = side opening door slam post width 50 (narrow frame) 150 (frame) 170 (front) 220 (front) 270 (front) HA = lintel height 50 (narrow frame) 195 270 370 470 HR = raw opening height 2225 2300 2400 2500 2600 2700 2800 2900 3000 Glass doors A = door frame height 100 150 220 B = 1100 A A Frame with MonoSpace control cabinet B-B B A

C-C A-A D-D B-B Narrow Frame Frame Front Frame with MonoSpace control cabinet Narrow Frame with half height glass doors Frame with half height glass doors Front with half height glass doors Front with MonoSpace control cabinet Narrow Frame class door Frame class door Front glass door with MonoSpace control cabinet Frame, A-A Frame with MonoSpace control cabinet, B-B

Sill alternatives: Standard sill with carpet trim Narrow sill Recommended door jamb and building interface types: Side frame by separate agreement Top frame C C D D by separate agreement

www.kone.com This publication is for general information and we reserve the right at any time to alter the product design and specifications. No statement it contains should be constructed as a warranty or condition, express or implied, as to any product, its fitness for any particular purpose or quality, or any modification or representation of the terms of any purchase agreement. Minor differences between printed and actual colours may exist. 1213