Single Zone LCD Thermostat Operating Instructions

Similar documents
OPERATING INSTRUCTIONS

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

Air Conditioner

Roof Top Unit. Description Model Type Use With Air Distribution Box Model B CX51R B CX51R

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

BRISK AIR 579 Series 590 Series 595 Series

MODEL Roof-Top Heat Pump used with Air Distribution Box Kit

40KMC KMQ

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT

09/23/2013. RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased:

Smart Temp. Model

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

T-Series Air Conditioner T20 Model

Owner's Manual TABLE OF CONTENTS

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

QD-ENG-68 Controller for Thermoelectric Thermal Management

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

Installation Instructions

1.1 Instructions for the o-led Display/Controller

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

Programmable Digital Thermostat

T-Series Air Conditioner T15 Model

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

OWNER S MANUAL Venstar Inc. 08/07

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

HEAT COOL. Meets Commercial California Title 24

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Portable Air Conditioner User Manual Read and save these instructions before use

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Use and Care Manual. MODELS H VAR 1.5 THRU 5 TON 13 Seer Split System Heat Pump REV. 4/06

Owner's Manual TABLE OF CONTENTS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Model TTWM1-14H ,000 BTU Cool 10,500 BTU Heat Electronic Through the Wall Air Conditioner Operating Instructions

PACKAGED TERMINAL AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

15,000 BTU Portable Air Conditioner

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

USER S MANUAL HSC-14/18/24/24A

HEAT HEAT HEAT COOL COOL

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

T-Series Air Conditioner T53 Model

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Ducted air conditioner Operating Manual

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Operator: Save these instructions for future use!

Owner s Manual TABLE OF CONTENTS

THRU-THE-WALL AIR CONDITIONER

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

THRU-THE-WALL ELECTRONIC CONTROL AIR CONDITIONER

Owner s Manual TABLE OF CONTENTS

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

Dometic Digital Control (for DX systems)

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

RCS Residential Control Systems Inc.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

OPERATING INSTRUCTIONS

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

Owner s Manual Super-Slim Four-Way Cassette

User s Information Manual

Outdoor Beverage Center

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

Hi Wall Split Air Conditioners

CONTENTS. Installation Guide. VT7200 Series

Transcription:

Fan *Heat Pump or Heat Strip F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX / 3313193.XXX //Heat Pump 3313194.XXX //Heat Strip

TABLE OF CONTENTS About Your New Thermostat Features...3 System Initialization...3 Factory Preset Settings...4 Quick Reference To Control Buttons...4 Programming & Operations...5 Temperature Format ºF / ºC...6 Inside Temperature...6 Selection...7 Fan Speed...7 Temperature Set-Point...8 Description Off...8...8-9...9 Heat Pump...10 Heat Strip...10 Fan...10 Special Features Auto Fan...11 Compressor Time Delay...11 Power Interruption...11 LCD Error Codes...11 General Information...12 Maintenance...12 Service...13 2

Congratulations! Your recreational vehicle manufacturer has equipped your RV with the most advanced RV thermostat. Your Dometic Single Zone LCD thermostat has been designed for ease of operation and for many years of reliable service. Features Liquid Crystal Display and Green LED Indicators Auto Fan Indoor Temperature Display F / C Display To help familiarize yourself with the operation of the Single Zone LCD thermostat, review the following diagrams and accompanying text that explain the functional characteristics of this system. Your Single Zone LCD thermostat is equipped with both a liquid crystal display (LCD) that identifies the temperature set-point, fan speed (Auto, Low, High), and F/C and green LEDs that indicate the mode of operation (Off, Fan,,, Heat Pump or Heat Strip*). The modes of operation available will vary depending on the system installed in your RV. * Select models. About Your New Thermostat System Initialization A system initialization will need to be performed by the installer after the system is installed. Make sure the Single Zone LCD thermostat is in the Off condition. See page 4, Quick Reference To Control Buttons. Press the + button and, while holding it, also press and hold the button for three seconds. LCD will show. Press the button again to turn system off. This completes the initialization. The furnace temperature differential should be set at this time. See Description - on page 9 for further information on furnace mode differential setting. 3

Your Dometic Single Zone LCD thermostat has been pre-programmed. Review settings below and adjust the settings to your personal comfort level. Factory Preset Settings Heating 68ºF / 20ºC ing 72ºF / 22ºC Fan Speed Auto Off Differential 2ºF Quick Reference To Control Buttons Indicates mode of operation when illuminated Press to increase temperature set-point Fan *Heat Pump or Heat Strip F * Select ls Press to select mode of operation Press to decrease temperature set-point 4

Programming & Operations To turn On the Single Zone LCD thermostat, press the button. The LCD will be activated. To turn Off the Single Zone LCD thermostat press the button and toggle through the modes until the green LED is on. The LCD will go out and the green LED will remain on for approximately 15 seconds, then go out. 5

Temperature Format ºF / ºC Simultaneously press the + and buttons to toggle between Fahrenheit and Centigrade format. ºF indicates Fahrenheit and ºC indicates Centigrade. Fan *Heat Pump or Heat Strip F Inside Temperature To display the Inside Temperature, the Single Zone LCD thermostat must be in the Off. Press either the + or button to display the Inside Temperature. Fan F 6

Selection Press the button to advance through the available modes. Each successive press will advance to the next available mode. The green LED will indicate the mode selected. Depending on the systems installed, your choices will be Off, Fan,,, Heat Pump or Heat Strip. See Description on pages 8-10 for more information on modes. Fan F Fan Speed Press the button until the fan green LED is lit. The LCD will show Lo (Low), Hi (High) or Au (Auto). Press the + or button to select the desired fan speed. See Special Features on page 11 for more information on Auto Fan. Fan 7

Temperature Set-Point Press the + or button to change the temperature set-point. The temperature set-point is indicated by two digits on the LCD. Press the + to increase and the to decrease the temperature setpoint. The maximum set-point for the system is 90º F. The minimum set-point is determined by the active operating mode. For heating, the minimum is 40º F and minimum for cooling is 55º F. Fan *Heat Pump or Heat Strip F Description Off - Off When selected, the LCD will be blank and the Off green LED will turn on for 15 seconds, then it will turn off. - In the mode the system will cycle the compressor On and Off based on the room air temperature and the temperature set-point on the Single Zone LCD thermostat. The fan will turn on first followed by the compressor in approximately 2 minutes. In this mode there are 3 fan speed selections: Lo - (LOW): The fan operates continuously at low speed. The compressor cycles ON and OFF. 8

Hi - (HIGH): The fan operates continuously at high speed. The compressor cycles ON and OFF. Au - (AUTO): When auto fan is selected the fan speed will vary depending on the difference between the temperature set-point and the room air temperature. In auto fan the compressor and the fan will cycle On and Off with the thermostat. See Special Features on page 11 for information on auto fan. - In the FURNACE mode the system will cycle the RV s furnace On and Off based on the room air temperature and the temperature set-point on the Single Zone LCD thermostat. The system can be configured to operate using an differential of either 1 degree F or 2 degree F. This feature is programmed during the system initialization. See System Initialization on page 3. To set the temperature differential the system must be Off. Press the button and, while holding it, also press and hold the button for three seconds. Release the button. Then release the button. Press the + button to toggle between d1 and d2, d1 for 1 degree F differential and d2 for 2 degrees F differential. In this mode there are 3 fan speed selections: Lo - (LOW): The fan operates continuously at low speed. Hi - (HIGH): The fan operates continuously at high speed. Au - (AUTO): The fan will be off. 9

Heat Pump - Heat Pump (Select ls) In the Heat Pump mode the system will cycle the compressor On and Off based on the room air temperature and the temperature setpoint on the Single Zone LCD thermostat. When the system calls for heating there will be a delay of approximately two minutes. In auto fan, the compressor will turn On first followed by the fan in approximately 15 seconds. In this mode there are 3 fan speed selections: Lo - (LOW): The fan operates continuously at low speed. The compressor cycles ON and OFF. Hi - (HIGH): The fan operates continuously at high speed. The compressor cycles ON and OFF. Au - (AUTO): When auto fan is selected the fan speed will vary depending on the difference between the temperature set-point and the room temperature. In auto fan the compressor and fan will cycle On and Off with the thermostat. The compressor shuts off first followed by the fan in approximately 15 seconds. See Special Features on page 11 for information on auto fan. Heat Strip - Heat Strip (Select ls) In the Heat Strip mode the system will cycle the heat strip On and Off based on the room air temperature and the temperature setpoint on the Single Zone LCD thermostat. In this mode there are 3 fan speed selections: Lo - (LOW): The fan operates continuously at low speed. The heat strip cycles On and Off. Hi - (HIGH): The fan operates continuously at high speed. The heat strip cycles On and Off. Au - (AUTO): The fan operates in low speed and will cycle On and Off with the thermostat. Fan - Fan In Fan mode there are 3 fan speed selections: Lo - (LOW): The fan operates continuously at low speed. Hi - (HIGH): The fan operates continuously at high speed. Au - (AUTO): The fan will be Off. 10

Special Features Auto Fan When auto fan is selected the fan speed will vary depending on the difference between the temperature set-point and the room temperature. In auto fan the compressor and fan cycle On and Off with the thermostat. When the difference is: >5º The fan operates on HIGH <4º The fan operates on LOW Compressor Time Delay A time delay of approximately two minutes occurs any time the compressor is required to begin the cooling or heat pump cycle. Power Interruption In the event the power to the air conditioner or control is interrupted, the system will restart with the previous set points once power is restored. LCD Error Code When the system determines that one of the faults listed below has occurred an error code will be displayed in the LCD. Error Code: E1 Loss of communication between the Single Zone LCD thermostat and the module board. LCD will cycle between E1 and the previous mode setting. System will shut down. E4 Open circuit or out of range Outdoor Temperature Sensor (select models). Heat Pump operation will be locked out. Air Conditioner, Fan and operation can continue to operate. E5 Open circuit or out of range Freeze Sensor. Air conditioner mode of operation will be locked out., heat strip and fan mode of operation can continue to operate but displays the last temperature set-point. 11

General Information A. The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor temperatures, the heat gain of the vehicle may be reduced by: 1. Parking the RV in a shaded area. 2. Using window shades (blinds and/or curtains). 3. Keeping windows and doors shut or minimizing usage. 4. Avoiding the use of heat producing appliances. Operation on High Fan/ing mode will give optimum or maximum efficiency in high humidity or high outside temperatures. Starting the air conditioner early in the morning and giving it a "head start" on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature. For a more permanent solution to high heat gain, accessories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening. B. The manufacturer of this air conditioner will not be responsible for damage caused by condensed moisture on ceilings or other surfaces. Air contains moisture and this moisture tends to condense on cold surfaces. When air enters the RV, condensed moisture may appear on the ceiling, windows, metal parts, etc. During normal operation, this unit removes moisture from the air. Keeping doors and windows closed when this air conditioner is in operation will minimize condensed moisture on cold surfaces. Maintenance Air Filter - Periodic (a minimum of every 2 weeks of operation) remove the return air filter located behind the return air grill and wash the filter with soap and warm water. Let dry and then reinstall. NEVER run the air conditioner without the air filter in place. This may plug the unit evaporator coil with dirt and substantially degrade the performance of the unit over time. Dometic Single Zone LCD thermostat: Clean the Single Zone LCD thermostat with a moist soft cloth. DO NOT spray water directly on the Single Zone LCD thermostat. DO NOT use solvents for cleaning. 12

USA SERVICE OFFICE Dometic, LLC 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 Service In the unlikely event the unit fails to operate or operates improperly, check the following before calling your service center. 1. If your RV is connected to a motor generator, check to be sure the motor generator is running and producing power. 2. If the RV is connected to a power supply by a land line, check to be sure the line is sized properly to run air conditioner load and it is plugged into the power supply. 3. Check your 120 VAC fuse or circuit breaker to see if it is open. 4. Check your 12 VDC fuse or circuit breaker to see if it is open. 5. After the above checks, call your local service center for further help. This unit must be serviced by qualified service personnel only. When calling for service, always give the following: 1. Air conditioner/heat pump l Number and Serial Number found on Identification Label located on the Base Pan of the unit. It is necessary to remove the return air cover to expose the rating plate. 2. Electronic Control Kit Part Number and Serial Number found on Identification Label located on the side of the Kit. This kit is mounted in the return air cavity and can be exposed by removing the return air cover. CANADA Dometic, LLC 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center Assistance Call: 800-544-4881 REVISION Form No. 3313327.011 6/10 (French 3313345.013) 2010 Dometic, LLC Lagrange, IN 46761 13