Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

Similar documents
Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE

BLOOD PLASMA Walk-in Freezers

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

MCR & MCR SERIES Roll-in & Pass-Thru Blast Chillers

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

A Complete Line Of Remote Rack Refrigeration Systems

Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT

Product/Feature Energy-Saving Function Where Used

MINI-ROOM COOLERS, FREEZERS & COMBINATIONS

INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)

INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)

The Endura Series. The right combination of versatility, efficiency and reliability in foodservice equipment.

BLAST CHILLERS & BLAST CHILLER/FREEZERS

The Endura Series. Options. The right combination of versatility, efficiency and reliability in foodservice equipment.

MASTER-CHILL ROLL-IN & PASS-THRU BLAST CHILLERS/FREEZERS

Walk-Ins & Refrigeration Systems

DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.

Walk-in Refrigerated Rooms. An Overview of Requirements, Options and Construction Details

INSTALLATION and OPERATION INSTRUCTIONS

HOLDING/PROOFING CABINETS HP2H-2M-SN APPLICATION OPTIONAL MODULAR CONSTRUCTION

When considering the purchase of a walk-in you most likely will be looking for the following things.

LOW PROFILE UNIT COOLER

PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS

INSTALLATION and OPERATION INSTRUCTIONS

SPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS

NOVA Products. Quality Refrigeration Since Reach-in, Roll-in & Pass-Thru Cabinets. Heated Cabinets. Blast Chillers. Blast Chillers/ Freezers

Walk-In Coolers and Freezers Installation & Operations Manual

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Walk-In Coolers and Freezers Installation & Operations Manual

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Preparation Table Raised Condiment Rail models 8000N

LOW PROFILE UNIT COOLER

Glass Doors, Hinged Bottom Mounts

Super-Flo Low Profile Unit Cooler

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION

MACH N-407 Heat Pump Air-Cooled Chiller

FOUNTAINS UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS APRIL 30,

FOGEL Caribbean Corporation

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

TB SERIES. Glycol Pizza/Salad/Sandwich Prep Tables Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

INSTALLATION and OPERATION INSTRUCTIONS

Indoor and Outdoor Merchandiser Features:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS BASE MODELS WORKTOPS, UNDERCOUNTERS & SANDWICH UNITS

Center Mount Unit Coolers

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

MAC N-407 Air-Cooled Chiller

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Cabinet & Merchandiser Price List

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

"N-Width" Reach-In Refrigerator-Freezer Models/Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

commercial refrigeration products

NOVA Products. Quality Refrigeration Since Reach-in, Roll-in & Pass-Thru Cabinets & Heated Cabinets. Open Air Merchandisers

The following is a University standard specification and shall be reviewed and edited by the Design Professional to be project specific.

Exclusive design distributes cold air through a system of ducts and louvers positioned throughout the cabinet.

Cabinet & Merchandiser Price List

Q SERIES MEDIUM TEMPERATURE REFRIGERATORS

Foodservice Fabrication Specialists

Product Specifications Sheets

INSTALLATION and OPERATION INSTRUCTIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

We maintain stock in many of our most popular models for immediate shipment.

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Installation and Operation Guide For

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

RM/RMX & RM-HP SERIES. Effective Date: 2011 IMPORTANT INFORMATION READ BEFORE USE

Reach In Refrigerators Bottom Mount

A QUICK GUIDE to our COMPLETE LINE of QUALITY REFRIGERATION PRODUCTS

Packaged refrigeration system Technical Guide

APPENDIX 3J FOOD SERVICES SPECIFICATIONS

3 Year Parts/Labor Warranty Additional 2 Year Compressor Warranty

Kramersaver Air Cooled Condensing Units

2018 PRICE LIST EffecTiVe 10/01/2018

Line #: 1a, 1b, 1c (CCSD # 2) PASS-THRU HEATED CABINET (NARROW): VICTORY HS-1D-1-PT, ONLY

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

FX Series FCSI. replace all your refrigeration needs with the most energy-efficient, flexible, food-safe system...ever!

Precise Temperature Control; Compact Footprint

RM/RMX & RM-HP SERIES. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Glass Door Merchandiser. Model RM-49

Canning Shed/Facility Equipment Specifications

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

TECHNICAL SPECIFICATIONS

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Global. Refrigeration, INC. QUALITY REFRIGERATION PRODUCTS Grant Avenue, Cleveland, OH

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

Glass Door Merchandiser

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Transcription:

Wall mount refrigeration systems available PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

PRS-2: The Keyword Is Simple Simple Convenience The PRS-2 series combines durable walk-in panels with a highly efficient packaged refrigeration system to give you the most convenient solution to your cooling or freezing needs. The condensing unit and evaporator coil are assembled together in one package which is ready to mount on the top or side of your Master-Bilt walk-in. Simple Installation Refrigeration labor costs are greatly reduced because there s no piping or other components to field install. Certain indoor models come with a power cord so the unit can be plugged in. Indoor units also have a standard condensate evaporator pan to eliminate the need for a drain line. Plus, our cam-locking panels are designed for rapid assembly so you can have your walkin up in no time. Simple Guarantee Each refrigeration system is fully assembled, evacuated, charged, run tested and wired at the factory for reliable performance. Adding to that assurance is a warranty covering parts and labor for 18 months, the compressor for one year (optional extended four year warranty available) and walk-in panels for 10 years. The PRS-2 evaporator grille mounts flush in a standard 4" thick ceiling or wall panel allowing maximum storage space. PRS-2 units are available in both indoor and outdoor models and in ceiling or wall mount (left) versions. Outdoor models are standard with a crankcase heater, drainline heater, head master and weather hood. PRS-2 Refrigeration System Design A convenient combination of condensing unit and evaporator coil in one package. Compressor Evaporator fans Evaporator coil Condenser coil Electrical box containing defrost timer 2

A Wealth Of Walk-in Features 4" thick polyurethane insulated panels with 26 gauge stucco galvalume or stucco white finish Weather-proof switch cover Deadbolt-locking handle Easy-to-assemble cam-lock construction Choice of 26", 30" or 36" wide door Packaged refrigeration unit Membrane roof (outdoor models only) With-floor or floorless applications Drip guard over door on outdoor models (not shown) 5-day shipping (from receipt of order) on models with ceiling mount refrigeration Master-Bilt s standard floor finish is an NSF listed.080 inch aluminum which is textured for added safety. Floors are also coved to meet sanitation guidelines. Master-Bilt s unique adjustable hinge backing plate ensures a proper fit of the door during installation and also allows for any necessary future adjustments without removal of the door or frame. Section through a typical V-series door featured in PRS-2 series walk-ins. See page 10 for more walk-in specifications. 3

Refrigeration System Specifications Ceiling Mount Systems PRS-2 MODEL* BTUH @ 90 F -10 F BOX TEMP BTUH @ 90 F 35 F BOX TEMP REFG. TYPE DIMENSIONS SEE FIGURE... (P. 6) DEFROST AMPS ELECTRICAL DATA TOTAL SYSTEM AMPS MCA MOP VOLTAGE NEMA PLUG SHIP WT. LB/KG HP CEILING MOUNT COOLER SYSTEMS PHHZ0050A N/A 5630 R-404A NS 5/8 N/A 14.3 N/A N/A 115/60/1 5-20P 230/105 PHHZ0050AT N/A 5630 R-404A NS 5/8 N/A 12.0 15.3 20 115/60/1 N/A 275/125 PHHZ0070B N/A 7740 R-404A NM 7/8 N/A 8.6 N/A N/A 208-230/60/1 6-20P 320/145 PHHZ0070BT N/A 7740 R-404A NM 7/8 N/A 8.6 12.0 15 208-230/60/1 N/A 360/164 PHHZ0100B N/A 11,200 R-404A NL 1 N/A 7.7 N/A N/A 208-230/60/1 6-15P 410/186 PHHZ0100BT N/A 11,200 R-404A NL 1 N/A 8.6 11.2 15 208-230/60/1 N/A 480/218 CEILING MOUNT FREEZER SYSTEMS PHXZ0070B 2700 N/A R-404A NM 5/8 N/A 7.7 N/A N/A 208-230/60/1 6-20P 280/127 PHXZ0070BT 2700 N/A R-404A NM 5/8 7.2 7.4 11.4 15 208-230/60/1 N/A 310/141 PHXZ0100B 3680 N/A R-404A NM 1 N/A 7.0 N/A N/A 208-230/60/1 6-15P 370/168 PHXZ0100BT 3680 N/A R-404A NM 1 6.7 7.0 9.7 15 208-230/60/1 N/A 410/186 PHXZ0125B 3980 N/A R-404A NL 1 N/A 7.5 N/A N/A 208-230/60/1 6-15P 465/211 PHXZ0125BT 3980 N/A R-404A NL 1 8.8 8.6 10.3 15 208-230/60/1 N/A 510/232 PHXZ0150B 6060 N/A R-404A NL 1 1 /2 12.2 12.0 13.9 20 208-230/60/1 N/A 525/239 PHXZ0150BT 6060 N/A R-404A NL 1 1 /2 10.9 9.8 12.0 15 208-230/60/1 N/A 565/257 PHXZ0200B 6510 N/A R-404A NL 1 1 /2 10.2 10.0 13.4 20 208-230/60/1 N/A 525/239 PHXZ0200BT 6510 N/A R-404A NL 1 1 /2 8.5 11.7 14.0 20 208-230/60/1 N/A 565/257 PHXZ0201B 8000 N/A R-404A NL 2 11.4 15.7 17.7 20 208-230/60/1 N/A 611/278 PHXZ0201BT 8000 N/A R-404A NL 2 10.3 14.2 16.4 20 208-230/60/1 N/A 691/314 *Outdoor models denoted with a T suffix. See chart below. PRS-2 refrigeration is sized for holding duty only. If the ambient is higher or pull down capacity is required, a regular (non-quick ship) quote will be needed. Ceiling Mount System Nomenclature 4

Wall Mount Systems PRS-2 MODEL* BTUH @ 90 F -10 F BOX TEMP BTUH @ 90 F 35 F BOX TEMP REFG. TYPE DIMENSIONS SEE FIGURE... (P. 7) ELECTRICAL DATA SHIP WT. LB/KG HP MCA MOP RLA VOLTAGE WALL MOUNT COOLER SYSTEMS WHHZ0050A N/A 3,251 R-404A NSW 1/2 14.4 20 9.1 115/60/1 294/133 WHHZ0050AT N/A 3,251 R-404A NSW 1/2 14.7 20 9.1 115/60/1 296/134 WHHZ0070B N/A 5,709 R-404A NLW 3/4 9.7 15 6.3 208-230/60/1 480/217 WHHZ0070BT N/A 5,709 R-404A NLW 3/4 10.6 15 6.3 208-230/60/1 487/220 WALL MOUNT FREEZER SYSTEMS WHXZ0050B 2,110 N/A R-404A NSW 5/8 8.3 15 4.4 208-230/60/1 321/145 WHXZ0050BT 2,110 N/A R-404A NSW 5/8 9.6 15 4.4 208-230/60/1 323/146 WHXZ0070B 2,845 N/A R-404A NSW 3/4 9.9 15 4.4 208-230/60/1 478/216 WHXZ0070BT 2,845 N/A R-404A NSW 3/4 9.9 15 4.4 208-230/60/1 480/217 WHXZ0100B 3,960 N/A R-404A NLW 1 9.7 15 6.3 208-230/60/1 529/239 WHXZ0100BT 3,960 N/A R-404A NLW 1 10.1 15 6.3 208-230/60/1 531/240 WHXZ0150B 5,560 N/A R-404A NLW 1.5 14.2 20 8.5 208-230/60/1 549/248 WHXZ0150BT 5,560 N/A R-404A NLW 1.5 14.6 20 8.5 208-230/60/1 581/263 *Outdoor models denoted with a T suffix. See chart below. PRS-2 refrigeration is sized for holding duty only. If the ambient is higher or pull down capacity is required, a regular (non-quick ship) quote will be needed. Wall Mount System Nomenclature MODEL NO. ROOM TEMP. 5

Refrigeration System Dimensions Ceiling Mount Systems Figure NS Figure NM Figure NL Consult Factory For Agency Listings 6

Wall Mount Systems Figure NSW Figure NLW Consult Factory For Agency Listings 7

Walk-in/Refrigeration Packages Ceiling Mount Systems WALK-IN CONFIGURATION ACTUAL SIZE FLOOR TYPE BTUH REQUIRED** MATCHING PRS-2 UNIT ROOF PANEL OPENING SIZE (in.) SHIP WEIGHT (PANELS PLUS PRS-2 UNIT) LB/KG INDOOR COOLERS 720606P* 5'10" x 5'10" x 7'2" Less Floor 2600 PHHZ0050A 22 1 /2 x 20 5 /16 948/431 720608P* 5'10" x 7'9" x 7'2" Less Floor 3400 PHHZ0050A 22 1 /2 x 20 5 /16 1097/499 720610P* 5'10" x 9'8" x 7'2" Less Floor 3900 PHHZ0050A 22 1 /2 x 20 5 /16 1247/567 720808P* 7'9" x 7'9" x 7'2" Less Floor 4100 PHHZ0050A 22 1 /2 x 20 5 /16 1262/574 720810Q* 7'9" x 9'8" x 7'2" Less Floor 4800 PHHZ0070B 33 1 /4 x 20 5 /16 1550/705 720812Q* 7'9" x 11'7" x 7'2" Less Floor 5500 PHHZ0070B 33 1 /4 x 20 5 /16 1714/779 721010Q* 9'8" x 9'8" x 7'2" Less Floor 5500 PHHZ0070B 33 1 /4 x 20 5 /16 1726/785 760606P* 5'10" x 5'10" x 7'6" With Floor 2600 PHHZ0050A 22 1 /2 x 20 5 /16 1118/508 760608P* 5'10" x 7'9" x 7'6" With Floor 3400 PHHZ0050A 22 1 /2 x 20 5 /16 1323/601 760610P* 5'10" x 9'8" x 7'6" With Floor 3900 PHHZ0050A 22 1 /2 x 20 5 /16 1529/695 760808P* 7'9" x 7'9" x 7'6" With Floor 4100 PHHZ0050A 22 1 /2 x 20 5 /16 1562/710 760810Q* 7'9" x 9'8" x 7'6" With Floor 4800 PHHZ0070B 22 1 /2 x 20 5 /16 1800/818 760812Q* 7'9" x 11'7" x 7'6" With Floor 5500 PHHZ0070B 33 1 /4 x 20 5 /16 2163/983 761010Q* 9'8" x 9'8" x 7'6" With Floor 5500 PHHZ0070B 33 1 /4 x 20 5 /16 2196/998 OUTDOOR COOLERS 720606T* 5'10" x 5'10" x 7'2" Less Floor 2600 PHHZ0050AT 22 1 /2 x 20 5 /16 1020/464 720608T* 5'10" x 7'9" x 7'2" Less Floor 3400 PHHZ0050AT 22 1 /2 x 20 5 /16 1169/531 720610T* 5'10" x 9'8" x 7'2" Less Floor 3900 PHHZ0050AT 22 1 /2 x 20 5 /16 1319/600 720808T* 7'9" x 7'9" x 7'2" Less Floor 4100 PHHZ0050AT 22 1 /2 x 20 5 /16 1334/606 720810T* 7'9" x 9'8" x 7'2" Less Floor 4800 PHHZ0070BT 33 1 /4 x 20 5 /16 1605/730 720812T* 7'9" x 11''7" x 7'2" Less Floor 5500 PHHZ0070BT 33 1 /4 x 20 5 /16 1769/804 721010T* 9'8" x 9'8" x 7'2" Less Floor 5500 PHHZ0070BT 33 1 /4 x 20 5 /16 1784/811 760606T* 5'10" x 5'10" x 7'6" With Floor 2600 PHHZ0050AT 22 1 /2 x 20 5 /16 1190/541 760608T* 5'10" x 7'9" x 7'6" With Floor 3400 PHHZ0050AT 22 1 /2 x 20 5 /16 1395/634 760610T* 5'10" x 9'8" x 7'6" With Floor 3900 PHHZ0050AT 22 1 /2 x 20 5 /16 1601/728 760808T* 7'9" x 7'9" x 7'6" With Floor 4100 PHHZ0050AT 22 1 /2 x 20 5 /16 1634/743 760810T* 7'9" x 9'8" x 7'6" With Floor 4800 PHHZ0070BT 22 1 /2 x 20 5 /16 1872/851 760812T* 7'9" x 11''7" x 7'6" With Floor 5500 PHHZ0070BT 33 1 /4 x 20 5 /16 2218/1008 761010T* 9'8" x 9'8" x 7'6" With Floor 5500 PHHZ0070BT 33 1 /4 x 20 5 /16 2251/1023 INDOOR FREEZERS*** 760606R* 5'10" x 5'10" x 7'6" With Floor 3400 PHXZ0125B 30 7 /8 x 25 3 /8 1361/619 760608R* 5'10" x 7'9" x 7'6" With Floor 4400 PHXZ0150B 30 7 /8 x 25 3 /8 1660/755 760610R* 5'10" x 9'8" x 7'6" With Floor 5300 PHXZ0150B 30 7 /8 x 25 3 /8 1866/848 760808R* 7'9" x 7'9" x 7'6" With Floor 5600 PHXZ0150B 30 7 /8 x 25 3 /8 1899/863 760810R* 7'9" x 9'8" x 7'6" With Floor 6600 PHXZ0200B 30 7 /8 x 25 3 /8 2253/1024 760812R* 7'9" x 11'7" x 7'6" With Floor 7600 PHXZ0201B 30 7 /8 x 25 3 /8 2131/969 761010R* 9'8" x 9'8" x 7'6" With Floor 7600 PHXZ0201B 30 7 /8 x 25 3 /8 2164/984 OUTDOOR FREEZERS*** 760606U* 5'10" x 5'10" x 7'6" With Floor 3400 PHXZ0125BT 30 7 /8 x 25 3 /8 1382/628 760608U* 5'10" x 7'9" x 7'6" With Floor 4400 PHXZ0150BT 30 7 /8 x 25 3 /8 1700/773 760610U* 5'10" x 9'8" x 7'6" With Floor 5300 PHXZ0150BT 30 7 /8 x 25 3 /8 1906/953 760808U* 7'9" x 7'9" x 7'6" With Floor 5600 PHXZ0150BT 30 7 /8 x 25 3 /8 1939/881 760810U* 7'9" x 9'8" x 7'6" With Floor 6600 PHXZ0200BT 30 7 /8 x 25 3 /8 2053/933 760812U* 7'9" x 11''7" x 7'6" With Floor 7600 PHXZ0201BT 30 7 /8 x 25 3 /8 2212/1005 761010U* 9'8" x 9'8" x 7'6" With Floor 7600 PHXZ0201BT 30 7 /8 x 25 3 /8 2245/1020 *Replace * with "X" for stucco galvalume interior & exterior or "E" for white stucco galvanized interior & exterior. **Coolers were designed for 35 F room temp with 90 F ambient and 100 F temp at condensing unit. Less floor coolers assumed no insulation under floor slab. Freezers were designed for -10 F room temp with 90 F ambient and 100 F temp at condensing unit location. ***All freezer doors include a standard pressure relief port. PRS-2 refrigeration is sized for holding duty only. If the ambient is higher or pull down capacity is required, a regular (non-quick ship) quote will be needed. 8

Wall Mount Systems Wall mount models require approximately a 3-week lead time. WALK-IN CONFIGURATION ACTUAL SIZE FLOOR TYPE BTUH REQUIRED** MATCHING PRS-2 UNIT WALL PANEL OPENING SIZE (in.) SHIP WEIGHT (PANELS PLUS PRS-2 UNIT) LB/KG INDOOR COOLERS W20606P* 5'10" x 5'10" x 7'2" Less Floor 2,600 WHHZ0050A 19 3 /8 x 14 3 /8 1158/526 W20608P* 5'10" x 7'9" x 7'2" Less Floor 3,400 WHHZ0070B 38 1 /2 x 14 3 /8 1493/679 W20610P* 5'10" x 9'8" x 7'2" Less Floor 3,900 WHHZ0070B 38 1 /2 x 14 3 /8 1643/747 W20808P* 7'9" x 7'9" x 7'2" Less Floor 4,100 WHHZ0070B 38 1 /2 x 14 3 /8 1658/754 W20810Q* 7'9" x 9'8" x 7'2" Less Floor 4,800 WHHZ0070B 38 1 /2 x 14 3 /8 1822/828 W20812P* 7'9" x 11'7" x 7'2" Less Floor 5,500 WHHZ0070B 38 1 /2 x 14 3 /8 1986/903 W21010P* 9'8" x 9'8" x 7'2" Less Floor 5,500 WHHZ0070B 38 1 /2 x 14 3 /8 2001/910 W60606P* 5'10" x 5'10" x 7'6" With Floor 2,600 WHHZ0050A 19 3 /8 x 14 3 /8 1514/688 W60608P* 5'10" x 7'9" x 7'6" With Floor 3,400 WHHZ0070B 38 1 /2 x 14 3 /8 1719/781 W60610P* 5'10" x 9'8" x 7'6" With Floor 3,900 WHHZ0070B 38 1 /2 x 14 3 /8 1925/875 W60808P* 7'9" x 7'9" x 7'6" With Floor 4,100 WHHZ0070B 38 1 /2 x 14 3 /8 1958/890 W60810Q* 7'9" x 9'8" x 7'6" With Floor 4,800 WHHZ0070B 38 1 /2 x 14 3 /8 2196/998 W60812Q* 7'9" x 11'7" x 7'6" With Floor 5,500 WHHZ0070B 38 1 /2 x 14 3 /8 2435/1107 W61010Q* 9'8" x 9'8" x 7'6" With Floor 5,500 WHHZ0070B 38 1 /2 x 14 3 /8 2468/1122 OUTDOOR COOLERS W20606T* 5'10" x 5'10" x 7'2" Less Floor 2,600 WHHZ0050AT 19 3 /8 x 14 3 /8 1160/527 W20608T* 5'10" x 7'9" x 7'2" Less Floor 3,400 WHHZ0070BT 38 1 /2 x 14 3 /8 1500/682 W20610T* 5'10" x 9'8" x 7'2" Less Floor 3,900 WHHZ0070BT 38 1 /2 x 14 3 /8 1650/750 W20808T* 7'9" x 7'9" x 7'2" Less Floor 4,100 WHHZ0070BT 38 1 /2 x 14 3 /8 1665/757 W20810T* 7'9" x 9'8" x 7'2" Less Floor 4,800 WHHZ0070BT 38 1 /2 x 14 3 /8 1829/831 W20812T* 7'9" x 11''7" x 7'2" Less Floor 5,500 WHHZ0070BT 38 1 /2 x 14 3 /8 1993/906 W21010T* 9'8" x 9'8" x 7'2" Less Floor 5,500 WHHZ0070BT 38 1 /2 x 14 3 /8 2008/913 W60606T* 5'10" x 5'10" x 7'6" With Floor 2,600 WHHZ0050AT 19 3 /8 x 14 3 /8 1521/691 W60608T* 5'10" x 7'9" x 7'6" With Floor 3,400 WHHZ0070BT 38 1 /2 x 14 3 /8 1726/785 W60610T* 5'10" x 9'8" x 7'6" With Floor 3,900 WHHZ0070BT 38 1 /2 x 14 3 /8 1932/878 W60808T* 7'9" x 7'9" x 7'6" With Floor 4,100 WHHZ0070BT 38 1 /2 x 14 3 /8 1965/893 W60810T* 7'9" x 9'8" x 7'6" With Floor 4,800 WHHZ0070BT 38 1 /2 x 14 3 /8 2203/1001 W60812T* 7'9" x 11''7" x 7'6" With Floor 5,500 WHHZ0070BT 38 1 /2 x 14 3 /8 2442/1110 W61010T* 9'8" x 9'8" x 7'6" With Floor 5,500 WHHZ0070BT 38 1 /2 x 14 3 /8 2475/1125 INDOOR FREEZERS*** W60606R* 5'10" x 5'10" x 7'6" With Floor 3,400 WHXZ0100B 38 1 /2 x 14 3 /8 1563/710 W60608R* 5'10" x 7'9" x 7'6" With Floor 4,400 WHXZ0150B 38 1 /2 x 14 3 /8 1788/813 W60610R* 5'10" x 9'8" x 7'6" With Floor 5,300 WHXZ0150B 38 1 /2 x 14 3 /8 1994/906 OUTDOOR FREEZERS*** W60606U* 5'10" x 5'10" x 7'6" With Floor 3,400 WHXZ0100BT 38 1 /2 x 14 3 /8 1563/710 W60608U* 5'10" x 7'9" x 7'6" With Floor 4,400 WHXZ0150BT 38 1 /2 x 14 3 /8 1788/813 W60610U* 5'10" x 9'8" x 7'6" With Floor 5,300 WHXZ0150BT 38 1 /2 x 14 3 /8 1994/906 *Replace * with "X" for stucco galvalume interior & exterior or "E" for white stucco galvanized interior & exterior. **Coolers were designed for 35 F room temp with 90 F ambient and 100 F temp at condensing unit. Less floor coolers assumed no insulation under floor slab. Freezers were designed for -10 F room temp with 90 F ambient and 100 F temp at condensing unit location. ***All freezer doors include a standard pressure relief port. PRS-2 refrigeration is sized for holding duty only. If the ambient is higher or pull down capacity is required, a regular (non-quick ship) quote will be needed. 9

Walk-in Specifications A. General Walk-ins shall be constructed of prefab, precision formed, modular panels designed for accurate, rapid field assembly and in compliance with the general construction as described in the Master-Bilt Architectural Specifications and General Design Information binder. Walk-ins and PRS-2 series ceiling mount package refrigeration systems will be available for shipment within five (5) working days of received order. Walk-ins with wall mount refrigeration systems will be subject to a three week lead time approximately. Indoor PRS-2 refrigeration systems will have a standard condensate evaporator pan to eliminate the need for a drain line. Master-Bilt's cam-locking modular panels are designed for accurate and rapid field assembly. B. Insulation Insulation shall be 4" thick rigid urethane, pourtype, foamed-in-place. C. Heights Walk-in coolers and freezers shall consist of 7'6" height for with-floor applications. Less-floor ap- plications shall consist of 7'2" height. Freezers are available in with-floor models only. D. Metal Finishes Walk-in coolers or freezers under this program shall have either 26 gauge stucco galvalume interior and exterior finish or 26 gauge white stucco galvanized interior and exterior finish. Floor interiors shall be.080 textured aluminum. Floor panels shall be designed to support an evenly distributed load of 700 lbs. per square foot loading (stationary load). E. Ratings and Listings Walk-ins under this program have been independently tested for: Structural Strength F.M. 4880 Class 1 A.S.T.M. E-84-94, D-1929-91a, D-482-91, D1622-93 U.L. and C-U.L. listed doors N.S.F. Listed N.Y.C. Approval #59-85 City of Los Angeles RR 25169 State of Oregon (consult factory) City of Houston Approval State of Wisconsin Approval State of California Bureau of Home Furnishings and Thermal Insulation Manufacturer Approval Type I Fabricator s License Approval State of Florida Approval Toxicity Evaluated Fully compliant with all Federal EISA requirements effective January 1, 2009 Reports available from factory on request. F. Entrance Door Stock walk-ins shall be complete with one (1) each infitting (flush-mount) self-closing entrance door. Door height will be 78" with choice of 26", 30" or 36" width (specify when ordering). Entrance door to include: Two (2) spring loaded cam-lift hinges Hydraulic door closure Deadbolt-locking handle Pre-wired compact fluorescent vapor-proof light fixture 10

G. Warranty Parts and labor are covered for 18 months, the compressor for one year (optional extended four-year warranty available), walk-in panels for 10 years. H. Exclusion Any deviation from these specifications and listed walk-in sizes does not qualify for this program, and is subject to Master-Bilt standard lead time. Please consult factory for lead-times on other walk-in sizes or specifications. Master-Bilt reserves the right to discontinue this program without notice. All specifications are subject to change without notice. PRS-2 walk-in entry doors are available either as left or right hinged. Inside safety release Mounted dial thermometer Magnetic gaskets along the top and both sides An adjustable double vinyl wiper gasket along bottom Drip guard over door in outdoor models In addition, the door shall contain adjustable hinge backing plates for each hinge. These plates shall provide for in-field adjustment of door hinges without removal of the hinges or door from its frame. On all walk-in freezers, the infitting door jamb shall be provided with a thermostatically-controlled warmer cable around the entire perimeter of the opening. The door shall be available either left hinged or right hinged (specify when ordering). These doors shall be mounted in a 46" wide door frame and shall be interchangeable with any 46" wide wall panel, thereby allowing placement to fit almost any job-site requirement. NOTE: Freezer door frame price includes one (1) each 3" diameter heated pressure relief port, factory mounted. The standard V-Series entry door is 78" high and is available in three widths: 26", 30" or 36". 11

For the latest product information and specifications go to www.master-bilt.com/products/products.htm. 908 Highway 15 North New Albany, MS 38652 Phone: 800-647-1284 Fax: 800-232-3966 www.master-bilt.com Due to continuous product enhancements, we reserve the right to change specifications without notice. 1215-7/13-web Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in USA.