OPERATING INSTRUCTIONS BIO ETHANOL FIREPLACES

Similar documents
WARNING! For your safety

Instruction Manual for Wall Mounted Fireplace, Models: ARC 103A & VAGUE 101A

SMART BIO ETHANOL ELECTRONIC BURNER

User s Manual & Safety Instructions Read Carefully Before Use

REMOTE CONTROLLED BIOETHANOL BURNER USER GUIDE

LATA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

LIMA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01

ATER SS. Ventless Ethanol Fireplace. User s Manual Installation Instructions

TAB. Ventless Ethanol Fireplace. User s Manual

Vigo Ventless Tabletop Bio Ethanol Fireplace. User s Manual. Model: GF301801

Cavo Tabletop Ventless Bio Ethanol Fireplace. User Manual. Model: GF301900BK (BLACK) GF301900W (WHITE)

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

Avila Contemporary Indoor Outdoor Ethanol Fireplace. User s Manual. Model: GF201500

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING WARNING. READ BEFORE USE! actory No.: HYTT Style No.:65124

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

Braga Free Standing Floor Indoor Outdoor Ethanol Fireplace User s Manual Model: GF202100

OPERATING INSTRUCTIONS AND SAFETY INFORMATION FOR BIOETHANOL FIREPLACES. models ASOLO TREVISO - VERONA

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

Using it in an enclosed space can kill you.

Instruction manual Safety instructions. Bio-fireplace

Renovator Range Firebox XL 1200SS

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

Wok Cookers Instruction Manual

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Table Top Patio Heater

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

USE AND CARE GUIDE PEDESTAL FIREBOWL

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

TecnoAirSystem OPERATING INSTRUCTIONS AND SAFETY INFORMATION FOR BIOETHANOL FIREPLACES. models ASOLO TREVISO - VERONA

Renovator Range Firebox 900SS

CAUTION FOR YOUR SAFETY

CASUAL FIRESIDE TM A HIGHER STANDARD IN QUALITY AND APPEARANCE - SAFE AND BEAUTIFUL OUTDOOR FIRE PIT FOR PROPANE AND *NATURAL GAS

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Standard models feature Burner One. - please refer to specific Model Specification.

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

USER S MANUAL. WallFire. Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

Material Safety Data Sheet

Landscape Fullview Series LFV SH LFV SH LFV SH LFV SH LFV SH

'' Stone Fireplace Model# SRFP41301 Instructions Manual

PLAN NOW!! Plan your escape today Your life may depend on it tomorrow HOME ESCAPE PLAN EXERCISE

! WARNING. Style # Laguna Ventless Rectangle Fire Table Owner s Manual. Restoration Hardware Customer Service:

User s Manual DANGER READ BEFORE USE! WARNING. For Outdoor Use Only! Use Propane Only!

PORTABLE PROPANE HEATER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

CYLINDER NOT INCLUDED

WARNING FIRE OR EXPLOSION HAZARD.

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

Propane Flame Projector Safety instructions and operating manual

KEROSENE FORCED AIR HEATER

INSTALLATION AND OPERATING INSTRUCTIONS

LANDSCAPE FULLVIEW SERIES MODEL 4015 MODEL 6015 MODEL 8015 MODEL MODEL SAFETY INFORMATION AND OPERATIONS MANUAL

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

Material Safety Data Sheet

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

CARBON MONOXIDE HAZARD. This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you.

Diesel / Kerosene Industrial Heater DHT66

OXYGEN CONCENTRATORS Information For Our Customers

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Reflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

Good Ideas For Propane Safety

U.S. Consumer Product Safety Commission Washington, DC 20207

POLAR BREEZE Statim Technologies, LLC IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS

Aerosol flame projector with spark effect Safety instructions and operating manual

Technology for Vacuum Systems. Instructions for use

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

TAMUCC Fire Safety Training

WARNING FIRE OR EXPLOSION HAZARD.

Outdoor Flame Heater

Owner s Manual OUTDOOR LIVING PERFECTED TONGA TORCH PORTABLE PROPANE

Home Fire CBI Electric Series HF36CBI HF42CBI HF60CBI

NFPA 45 NFPA 211 NFPA 1600

User s Manual. Fireball South Africa Fire Extinguisher Ball. An ounce of prevention is worth a pound of cure FOR. Fireball SA Extinguisher Ball

Flammable and Combustible Liquids

2 BURNER STOVE WITH GRILL

Using Your Hearth Cabinet Decorative Fireplace

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Instructions for High Altitude Installations Above 4500 FT.

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Riaza Tablemount Fire Bowl. Item# Model# HYUTT DANGER If you smell gas: 1. Shut off gas to the appliance.

Standard models feature Burner One. - please refer to specific Model Specification.

for Assembly, Operating & Maintenance of THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of

Electric Fireplace. Electric Fireplace

Operating Instructions

Model Numbers REM-80V-LPC-O / REM-200V-LPC-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS

NO VENTING REQUIRED 120V AC;

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

Safety instructions and routines on lab Faculty of Odontology Malmö University

Housing Fact Sheets. Home Fire Protection

The Heating System and Ventilation and Combustion Air

PARAFFIN/DIESEL HEATER

Owner s Manual. Revillusion Suites Osbourne Revillusion Suite OSB20-AU Windlesham Revillusion Suite WDS20-AU Strata Revillusion Suite STA20-AU

K-Star International Group Inc. K-Star Electronic Appliance Inc. Toll Free:(800)

Transcription:

OPERATING INSTRUCTIONS BIO ETHANOL FIREPLACES

min. 5 ft min. 10 in min. 10 in min. 4 ft

max. 1.5 liters 3 sec. 5 min. BIOETHANOL

Important information! Never use your fireplace if it has been damaged or modified in any way. Improper use or failure to follow appropriate safety precautions may result in serious injury or death as well as damage to or loss of property. Read all information completely before using your Buschbeck bio ethanol fireplace. Do not discard these instructions. Keep them with your Buschbeck bio ethanol fireplace for future reference. 4 Choose a proper location for your fireplace! Place your Buschbeck bio ethanol fireplace on a solid, flat, level foundation where it will not be accidentally kicked or bumped by any unsuspecting person or animal. Place it safely away (4 feet or more) from any potentially flammable objects. Moveable objects (curtains, drapes, etc.) must not be allowed to come within 4 feet of the fireplace, and never above it. Keep the fireplace away from drafts or any type of wind such as from fans, ventilators, etc. Position the fireplace at least 10 inches away from any wall or vertical surface and at least 5 feet from any ceiling or overhanging objects.

Read carefully before using! Never allow children or animals near the fireplace. Never allow the fireplace to burn without adult supervision. The fireplace may become very hot during use. Do not touch any surface without allowing proper time to cool. Use the lighting and flame adjustment tool (supplied) to slide the flat stainless steel insert over the firebox to extinguish or to adjust the flame. The flat stainless steel insert must be placed on top of the firebox during use. See the drawings supplied with the fireplace for proper orientation of parts. Never bend over the fireplace when lighting the flame. Do not allow face, hands or other body parts or clothing to extend over the fireplace. Do not store additional fuel anywhere near the fireplace. Fuel is designed to burn and fumes can be explosive. Exercise extreme caution and follow all instructions carefully. Keep additional fuel tightly capped and away from any potential source of combustion. Fuel Your Buschbeck bio ethanol fireplace is designed to be used only with the highest quality pure bio ethanol fuel such as OZOfire TM brand (www.fuelbarons.com), available from your fireplace retailer. The highest quality bio ethanol fuel should not produce any harmful pollutants. Always refer to the information provided by the supplier of the fuel. Study all information available from the fuel supplier. Follow all instructions and recommendations from the fuel supplier exactly. Buschbeck bio ethanol fireplaces have been designed and manufactured to the highest quality and safety standards. Buschbeck bio ethanol fireplaces have been tested and certified by government agencies and independent laboratories and have received the highest ratings for quality and safety. You will only realize the benefits of this quality design and safety when the best and purest bio ethanol fuel is used. The Buschbeck firebox chamber is designed to hold up to 1.5 liters of fuel. Use the handy funnel (supplied) to fill the fuel chamber. Do not over fill. Clean and dry any spills and wait 5 minutes before lighting the flame. Never add fuel when the firebox is warm or when there is any flame present. Allow the firebox to cool for at least 15 minutes before refilling. 5

Important information! Read carefully before using! While your Buschbeck bio ethanol fireplace is designed and approved for indoor use, careful consideration should be given to the following issues Proper air exchange is absolutely necessary to maintaining adequate oxygen levels for breathing. Any flame consumes oxygen. The oxygen that is consumed must be replaced in order to maintain an atmosphere that is healthy for breathing. This usually occurs automatically through the normal air exchange that takes place through walls, cracks and seams in the building. If there is any doubt, additional fresh air should be introduced by way of an open window, while the fire is burning. The size of the room is one of the most important matters to consider. DO NOT OPERATE THE FIREPLACE IN SMALL OR TIGHTLY ENCLOSED SPACES. The information on page 7 may be helpful in determining air exchange requirements. 6 F Xi SAFTEY INSTRUCTIONS FOR HANDLING BIO-ETHANOL UN 1170 Ethanol, solution > 95% vol. - completely methylated with 1% methyl ethyl ketone and 10 ppm denatonium benzoate ADR: 3,II / Water Hazard Classification: 1 Keep out of the reach of children! Never pour into open flame or embers! Not suitable for human consumption! Keep container sealed and closed! Keep away from ignition sources! If swallowed, immediately call a physician and show the packing/label! Protect from strong sunlight! Immediately wipe up spilled ethanol with a moist cloth!

Important information! Read carefully before using! TECHNICAL DATA Filling volume, ethanol Combustion time Fuel throughput 1.5 liters ca. 3-5 - 4 hours 0.44 l (max. 0.5 liter permitted) INSTALLATION CONDITIONS Minimum room volume cubic meters Air exchange [1/h] 332 0,2 (1) 111 0,6 (2) 66 1,0 (3) (1) Air exchange rate due to leakage in the building (2) Normal air exchange rate in leakproof buildings with standard (3) Complete air exchange in installation room during one hour Air exchange [n/h]* Comments 0... 0,5 Windows, doors closed 0,3... 1,5 Window open, no shutters 5... 10 Window half open user airing habits * n/h refers to the ratio of air circulation in the roomfor example, 0.5/h means that half of the air in the room is replaced each hour. USE ONLY GENUINE REPLACEMENT PARTS! (Firebox; Single-pane safety glass) 7

TÜV certified The fire safety and operational safety of the device have been tested by TÜV Süd Industrie Service, Munich. (Test report no. W-O 1173-00/08). Buschbeck GmbH Friedrich-Engels-Straße 21 D-51545 Waldbröl Germany www.buschbeck-indoor.de OI US 09.09 GD/FA 250 Technical alterations without notice MADE IN EU