Installation Instructions

Similar documents
Installation Instructions

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Installation Instructions

Installation Instructions

Installation Instructions

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings

Model 4001 Series Single Channel Controller

Beacon 800 Gas Monitor Operator s Manual

2-Port alarmcharge Hub - Manual

CO2 Sensor User and Installation Guide

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

MaxLite LED Vapor Tight Linear Fixture

ESRB and ESRN Installation & Safety Instructions

Pump-Up Controller MODEL 4062

INTEGRATED LIGHTING CONTROLS

HIGH BAY APPLICATIONS

Pump-Down Controller MODEL 4052

Beacon 410A Gas Monitor Operator s Manual

Beacon 110 Gas Monitor Operator s Manual

MaxLite LED Round Pendant Highbay Series

STATUS ALARM HISTORY ALARM RESET

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

CARMEL 48 CEILING FAN

Honeywell ENERGY SAVINGS KIT

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Instruction Manual Model L2 RF Switch

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Addendum for STI-6406 with Dual Access Control

Exit Stopper. STI-6400 Series

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

180 Degree Ceiling Mounted Occupancy Sensors

SECTION LOW VOLTAGE LIGHTING CONTROLS

Beacon 200 Gas Monitor Operator s Manual

Miro Wireless Dimming and Scene Control Made Elegantly Simple

GAS MONITOR Model Model

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Exit Stopper. STI-6400 Series

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Static Pressure Control

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

RIO 54 CEILING FAN MODEL # Español p. 19

MaxLite LED MICRO-T PANEL

TOUCHDOWN 48 CEILING FAN

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

LOS SUPER CEILING SENSOR Installation Manual

Figure 1. Figure 2. See notes 1 and 2 below.

VA301C CONTROLLER WITH BACnet OPTION

2800 Series Control Units

Global Water Instrumentation, Inc.

BACKUP BATTERY INSTALLATION INSTRUCTIONS

SPRINGHILL 44 CEILING FAN

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Applied Lighting Controls

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Universal Fan and Light Remote Control

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

Product Manual SZ1145

ITEM # SAIL STREAM CEILING FAN MODEL #41695

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

Environmental Monitoring SmartSlot Card

Integrated Classroom Control System. Installation and Operation Manual

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

SERVICE BY QUALIFIED PERSONNEL ONLY

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

ion Genesis Pump Controller

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Instruction Manual Model Backup Switch, 1 for 8

Installation Manual. Models 99168, 99169, 99170

ELP21LU3-LF-HLOL THREE CHANNEL

A. This Section includes the following lighting control devices:

Please Keep This Manual For Future Reference REV.01

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

52 STRATHMERE CEILING FAN

Product Manual SZ1144

Decorative Low Profile Integrated Kit

SECTION LIGHTING CONTROL DEVICES

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

LIGHTING CONTROL DEVICES

Transcription:

Fixture Mount Night Light Controller SPECIFICATIONS Power.....................................120VAC, 60Hz Relay Type..................................Form C, N.O. Load Requirements @120VAC......................................500W.......................... isolated relay rated 5A 250VAC Low Voltage Connections RJ45 connection to FS sensor.. Control in, common, +24VDC 8-Pin connector to LED strip and battery 2-wire output to LEDs............. 400mA @10VDC max. 2-wire output to 9V Ni-MH battery....5-8ma @10VDC max. Line and Load Connections.............. 12-18AWG terminals Operating Temperature.............. 32 to 131 F (0 to 55 C) Dimensions............. 7.5 x 0.75 x 1.5 (190 x 19 x 38mm) Installation Instructions

DESCRIPTION The controller supplies power to FS series occupancy sensors, a light fixture ballast and an LED night light associated with the fixture. It also supplies a trickle charge for a 9Volt battery that provides backup power to the LED night light. The is designed for installation inside the lighting fixture housing. The has a male RJ45 plug attached to a 10 cable. Each FS series 24VDC occupancy sensor is equipped with a cable fitted with a male RJ45 plug. The two devices must be connected using the shielded male-to-male RJ45 connector provided with the. This cable carries power to the sensor and lighting control signals to the. Typically, the is connected to one FS sensor installed inside the lighting fixture, however, each controller can supply power for up to three FS series sensors. FS-CK accessory kits are required to connect multiple sensor wiring configurations. High voltage wiring should use at least 16 AWG wire. Check local building codes. OPERATION The must be used with a Legrand 740 31 momentary switch, provided with the. The switch toggles the fixture between full lighting operation, nightlighting using the LEDs, and no lighting at all. When the light fixture is ON, the FS sensor controls the light. When no motion is detected and the occupancy sensor s delay expires, the light goes OFF and the LED nightlight goes ON. Push the switch button twice to force OFF all lights. During a power failure lasting more than 2 seconds, the uses the 9V battery to power the LEDs. To conserve battery, the LEDs appear dimmer than during normal nightlight operation. The length of time the LEDs are lit during a power failure depends on battery status. To protect the battery, the turns off the LEDs when the battery discharges below a safe level. Low voltage connector to LED and Battery wire assembly provided by fixture manufacturer Shielded male-to-male RJ45 extension connector Low voltage RJ45 connection to FS sensor Line voltage input and Switch wiring 04799r1 120VAC Input HOT NEUTRAL GROUND 12-18AWG CU wire only C US LISTED Appliance Control 88T9 Model: Fixture Nightlight Controller 120VAC, 60Hz @120VAC 5A (N/O) Santa Clara, CA 800.879.8585 ISOLATED RELAY OUTPUTS TO LOAD COM LOAD 04800r1 Green LED Fig 1: connections and operation monitor LED Call 800.879.8585 or 972.578.1699 for Technical Support

INSTALLATION 1. Determine an appropriate mounting location inside the light fixture. 2. Use the holes or mounting slots at both ends of the to secure it to the fixture. 3. Install the LED nightlight strip and the 9Volt rechargeable Ni-MH battery (both provided by fixture manufacturer) in the fixture. 4. Install the FS sensor and make appropriate adjustments as described in the FS installation instructions. 5. Connect the RJ45 from the sensor to the RJ45 on the. 6. Connect the 8-pin low voltage connector from the to the battery and LED connector (supplied by fixture manufacturer). 7. Connect wires to load, switch and electrical supply as described in the wiring section. CAUTION MAKE SURE POWER IS OFF BEFORE INSTALLING THE SWITCH OR CONTROLLER. WIRING 12-16 AWG Low voltage connector to LED and Battery wire assembly provided by fixture manufacturer Cu Only Shielded male-to-male RJ45 extension connector Low voltage RJ45 connection to FS sensor Line voltage input and Switch wiring 04799r1 120VAC Input HOT NEUTRAL GROUND 12-18AWG CU wire only C US LISTED Appliance Control 88T9 Model: Fixture Nightlight Controller 120VAC, 60Hz @120VAC 5A (N/O) Santa Clara, CA 800.879.8585 ISOLATED RELAY OUTPUTS TO LOAD COM LOAD 04800r1 Green LED Fig 2: electrical supply, switch and lighting load wiring Visit our website for FAQs: www.wattstopper.com

Male-to-Male RJ45 Connector FS-205 Sensor 120VAC Input HOT NEUTRAL GROUND 04799r1 12-18AWG CU wire only C US LISTED Appliance Control 88T9 Model: Fixture Nightlight Controller 120VAC, 60Hz @120VAC 5A (N/O) Santa Clara, CA 800.879.8585 ISOLATED RELAY OUTPUTS TO LOAD COM LOAD 04800r1 To 9V Battery 8-Pin Connector To LED Strip Fig 3: RJ45 and 8-Pin connections Call 800.879.8585 or 972.578.1699 for Technical Support

TROUBLESHOOTING Lights will not turn on: Sensor LED does not flash: - Is green LED on? If yes, check RJ45 connections between sensor and. If no, check circuit breaker and wiring to wall switch and. - Check all wire connections. LED does flash: - Press the wall switch to toggle between OFF, nightlight, and full operation. - Check all wire connections and verify the load wire is tightly secured. Is the switch wired correctly? If lights still do not turn on, call 800.879.8585 for technical support. Lights will not turn off: The time delay on the FS sensor can be set from 30 seconds to 30 minutes. Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period. To quickly test the unit for proper operation, turn the time delay to minimum and move out of the sensor s view. Lights should turn off after 30 seconds. If lights still do not turn off, call 800.879.8585 for technical support. Call 800.879.8585 or 972.578.1699 for Technical Support

ORDERING INFORMATION Catalog # FS-105 FS-205 FS-305 FS-CK-1 Description Fixture night light package includes: one controller (120VAC, 60Hz), one male-to-male RJ45 connector, one Legrand 740 31 wall switch and cover plate (sensor sold separately) Ceiling tile mount, low voltage PIR occupancy sensor with adjustable time delay and light level Fixture mount, low voltage PIR occupancy sensor with adjustable time delay and light level Fixture or ceiling tile mount, low voltage PIR occupancy sensor, adjustable time delay Extension cables and splitter: two 10 cables with a shielded RJ45 male connector at each end, one shielded RJ45 splitter with female to dual female receptacles All sensors and are White. WARRANTY INFORMATION The Watt Stopper, Inc. warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of The Watt Stopper, Inc. for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. Putting a Stop to Energy Waste 2800 De La Cruz Boulevard, Santa Clara, CA 95050 Technical Support: 800.879.8585 972.578.1699 www.wattstopper.com 04798 r1 11/2004