Levanté. Electric Panel Heater. Operating & Installation Instructions LPH15 LPH20.

Similar documents
Noirot Spot Plus Digital Timer

FAN HEATER FH118 User Manual

Convection Panel Heater

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

Models: RP-10, RP-15, RP-20. User Manual

General Care and Safety Guide

Oil-filled Radiator NY23EC-11L User Manual

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Operating Instructions. Oil Column Heater. Models: GOC155, GOC157, GOC1511

INSTRUCTIONS AND WARRANTY

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

STYLE COLLECTION HAIRDRYER

COMPACT PRO YEAR WARRANTY D2050AU USE & CARE MANUAL. To register your product go to

Lucci Designer Hi Flow Exhaust Fan

USE & CARE MANUAL PRO-TOUCH PLEASE READ PRIOR TO USE SENSOR 2 YEAR WARRANTY D6050AU

BAYSIDE JETSTREAM CEILING FAN

OSCILLATING FAN HEATER INSTRUCTION MANUAL

LUCCI AIRFUSION TAKEKO CEILING FAN

Electronic Ceramic Tower Heater

/09.15_00. De Longhi Appliances via Seitz, Treviso Italia

LUCCI AIRFUSION SHOALHAVEN CEILING FAN

General Care and Safety Guide

10cm Desk Fan User Manual

2.9kW Portable Air Conditioner

MANUAL. Aero YEAR WARRANTY D2115AU

LUCCI AIRFUSION MARINER CEILING FAN

2200W RADIANT HEATER GVARH350. Instruction Manual

LUCCI AIRFUSION AIRMOVER CEILING FAN

LUCCI FUTURA MOOD LED CEILING FAN

MILLI CUBE HEATED TOWEL RAIL 825 X 600

AIRFUSION MOONAH SERIES CEILING FAN

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

General Care and Safety Guide

VOLUME UP STRAIGHTENING BRUSH

SOHO HAIR DRYER STYLING GIFT PACK 2 YEAR WARRANTY D4512AU USE & CARE MANUAL

BAYSIDE NAUTILUS CEILING FAN

LUCCI WHITEHAVEN DC CEILING FAN

instyle collection 2 YEAR WARRANTY D3016AU

OPERATING INSTRUCTIONS

BLUSH STYLE COLLECTION

LUCCI ALTITUDE ECO LED CEILING FAN

KERATIN & ARGAN OIL NOURISH HAIR DRYER

Convection Panel Heater

Turbo Circulating Fan (DC)

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

PRO-AIR TURBO 2 YEAR WARRANTY D5220AU USE & CARE MANUAL. To register your product go to

SMOOTH FINISH CERAMIC 2 YEAR WARRANTY S3505AU USE & CARE MANUAL. To register your product go to

SHINE REVIVAL 3 YEAR WARRANTY AC4001AU USE & CARE MANUAL 2300 WATTS FOR ULTRA FAST DRYING SALON PROFESSIONAL AC MOTOR TRIPLE INFUSION TECHNOLOGY

KERATIN & ARGAN OIL NOURISH

SILK CERAMIC HAIR DRYER 5 YEAR WARRANTY AC9096AU USE & CARE MANUAL 2400 WATTS SILK CERAMIC GRILLE PLEASE READ PRIOR TO USE

FUTURA SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN

PRO BIG CURLS 2 YEAR WARRANTY CI5338AU USE & CARE MANUAL. PRO CERAmIC TECHNOlOGy 30 PRO HEAT SETTINGS PLEASE READ PRIOR TO USE

Ceramic Wall Heater With Remote

LUCCI AIRFUSION BANKSIA DC CEILING FAN

Platinum Series Electronic Panel Heaters

QUICK GROOM 2 YEAR WARRANTY BHT6450AU USE & CARE MANUAL. To register your product go to remington-products.com.au remington.co.nz

LUCCI AIRFUSION FRASER DC CEILING FAN

2.9kW Portable Air Conditioner

BAYSIDE CALYPSO CEILING FAN

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

User Manual. 3.5L Deep Fryer Stainless Steel Model Number: MDF35S READ AND SAVE THESE INSTRUCTIONS

FUTURA ECO SERIES CEILING FAN

PROLUXE SALON STRAIGHTENING BRUSH

PANEL HEATERS OPERATING INSTRUCTIONS

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

General Care and Safety Guide

Customer Operation & Installation Manual Electric Panel Heaters

SALON TURBO 3 YEAR WARRANTY AC2400AU PROFESSIONAL LONG LASTING AC MOTOR TURBO POWER FAN FOR FAST DRYING TOURMALINE CERAMIC TECHNOLOGY

40cm Wall Fan With Pull Cord Operation

1500W CERAMIC HEATER. Instruction Manual

INSTALLATION & USER INSTRUCTIONS

LUCCI NORDIC DC CEILING FAN

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

Contact Details. Please note that some of the contact details on this PDF document may not be current.

OWNERS INSTRUCTION MANUAL

INSTRUCTIONS AND WARRANTY

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

READ AND SAVE THESE INSTRUCTIONS

1.7L KETTLE INSTRUCTION MANUAL 220~240V 2200W

Bagged Vacuum Cleaner with Powerhead. Compact Powerhead for a Powerful Clean Washable HEPA Filtration High Efficiency Soft Start Motor

Table of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SILK CERAMIC STRAIGHTENER

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

USE, CARE AND INSTALLATION INSTRUCTIONS FOR YOUR NEW CANNON HORIZON HEATER

8 LITRE URN. Instruction Booklet. Please read these instructions carefully and retain for future reference

7 Fin Oil Filled Radiator

BLOW DRY IN A BOX 3 YEAR WARRANTY AC3501AU USE & CARE MANUAL SALON PROFESSIONAL AC MOTOR SUPERIOR HIGH VELOCITY AIRFLOW TOURMALINE IONIC TECHNOLOGY

INSTRUCTIONS AND WARRANTY

Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

I N S T R U C T I O N S

Steam Mop User Manual

IMPORTANT SAFETY INSTRUCTIONS

Model No.: VUM33AS20G

Transcription:

Levanté Electric Panel Heater Model: LPH10 LPH15 LPH20 Operating & Installation Instructions www.noirot.com.au

RECOMMENDATION FOR WALL INSTALLATION This heater is sold ready for DIY installation, with Wall bracket and flexible cord supplied. Fit the wall bracket to the wall with suitable fixing method according to the surface you mount the heater on (not included). Fit the rubber spacers as shown in Fig. 1 and hang the heater on to the wall bracket. The heater must not be located immediately below a socket outlet (as per requirement of Clause 7.12 of AS/NZS 60335.2.30). Fig. 1 1 2 3 4 5 6 12 11 10 9 8 7 LEGEND 1. Heating air outlet 2. Front panel 3. Thermostat dial 4. Control box air outlet 5. On/Off dial 6. Rear panel SPECIFICATIONS: 7. Castors (optional) 8. Air Inlet 9. Rubber spacer 10. Control box air inlet 11. Control box 12. Wall mounting bracket Model Power (W) Current (A) Height Width LPH10 600/1000 2.5/4.2 420 440 LPH15 900/1500 3.8/6.3 420 610 LPH20 1200/2000 5.0/8.3 420 760 Levanté International: 1 300 664 768 www.levanteinternational.com.au 2

Please note: Heater temperature settings will vary from house to house according to the building type and its level of insulation. They will also vary from room to room, depending on factors such as room orientation (facing north or south) and window sizes. Items such as computers and lights (which generate heat) and people will also affect a room s temperature. Running costs are not wholly governed by the temperature setting on the panel heater. The same maximum power is used to reach 10 or 30. Where the energy efficiency and economy is obtained is in the sizing of the heater to the particular room where it is to be used. If the heater is sized correctly, then the thermostat will cycle on & off as required to maintain your comfort level, no matter where on the scale your comfort setting is. RECOMMENDATION FOR USE WITH CASTORS This heater is tested and approved for use with the optional castors. To fit the castors to the heater, complete the following: 1. Turn the heater upside down 2. Position the castors over the plates located at either end of the heater 3. Fix the castors in place using the screws provided This heater is fitted with a Tip-over cut-out switch. If the heater falls over is tipped upside down, the power will be cut to the element. To restore power to the element and continue using your heater, stand it back on its castors. The Tipover cut-out switch will automatically reset itself. WARNING: Do not use the heater on the floor without the castors. Also, when using as a portable heater do not use in the immediate vicinity of a bath, shower or swimming pool. Levanté International: 1 300 664 768 www.levanteinternational.com.au 3

PANEL LOCATIONS This heater is suitable for use in all rooms including Zone 2 in Bathrooms (Fig.2) in accordance with AS/NZS 3000: 2000 (Wiring Rules). However, it must be located so that the controls cannot be touched by a person in the bath or shower. Fig. 2 For maximum efficiency, this heater should be wall mounted at a height of 150-200mm off the floor. This is to allow the necessary volume of air to flow freely through the vents. It is also important to allow a minimum of 100mm clearance at the top and sides of the heater and 500mm from the front (Fig. 3) so as not to force the air back into the heater and activate the Over Temperature Safety Thermal Cut-Out Switch. Fig. 3 Levanté International: 1 300 664 768 www.levanteinternational.com.au 4

ELECTRICAL CONNECTION This heater is fitted with an Australian Approved Flexible Cord and Plug. For wallmounted installations connection can be either by plugging into an existing 10 amp power point (DIY) or direct wired by a Licensed Registered Electrical Contractor, who is required to issue a Certificate of Electrical Safety. PLEASE NOTE: For safety reasons the Flexible Cord must not be modified or repaired in any way. If the Cord is damaged, it must be replaced by a Noirot appointed and approved service agent. If there are any concerns, contact Levanté International Pty Ltd on 1 300 664 768 before plugging it in. IMPORTANT: Do not plug in to a Power Board, Double Adaptor or Extension Lead. IMPORTANT: DO NOT COVER THE HEATER Avoid blocking air flow to and from the heater with clothing, open doors, furniture and small toys or paper inserted into the louvres. This will cause the heater to over-heat and activate the safety thermal cut-out switch. If the Over Temperature Safety Thermal Cut-Out Switch is activated, the heater will automatically switch off to limit the temperature to a safe value. To reset the thermal cut-out, simply switch the heater off, unplug it from the power point and remove the obstruction(s). Plug the heater back in and switch it on. The thermal cut-out switch will reset after a few minutes and the heater will function normally. USING YOUR HEATER FOR THE FIRST TIME Remove the heater from its packaging (please dispose of packaging responsibly). Contents should be as follows: 1. Heater 2. Wall bracket and rubber spacers 3. Instructions for installation and use (8 page booklet). Ensure the heater is correctly mounted on the wall or fitted to the castors prior to turning it on. Remove the white plastic protective covers from the plug pins and insert the plug into the wall socket. This heater is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the heater safely. Children should be supervised to ensure that they don t play with the appliance. NOTE: When the heater is turned on for the first time, or after it has been off for a long period, such as during the summer months, you may experience a slight burning smell. This is quite common and should disappear after a few minutes. If it should persist, switch the heater off and have it inspected. Levanté International: 1 300 664 768 www.levanteinternational.com.au 5

HOW TO USE THE THERMOSTAT The Levanté thermostat is designed to regulate the room A B temperature. This offers maximum economy, greater efficiency and is very simple to use. 0 1 2 1. Plug the heater into the GPO and turn on the GPO switch. 2. Turn the heater on by rotating dial A from 0 to 2 3. Rotate dial B all the way to H 4. Allow time for the room to heat up. This will vary with the size of the room but usually takes 15-20mins. Once the room reaches your desired temperature, rotate dial B back until you hear a CLICK 5. To achieve your comfort level simply adjust the dial B to suit. If you require more heat turn the B dial up to a larger DOT. If the room is too hot then turn the dial B to a smaller DOT. 6. To operate the heater at the reduced power level, simply rotate dial A to position 1. If the heater does not maintain the room temperature at this power level, rotate dial A back to position 2. MAINTENANCE Your Levanté Electric Panel Heater requires very little maintenance. To remove surface dust use a soft cloth; to remove marks use a damp cloth. Never use abrasives or metal scourers which could damage the powder coating. It is recommended to periodically clean the inlet and outlet air vents using the soft brush on your vacuum cleaner, as dense accumulation of dust will cause the heater to over-heat and trigger the safety thermal cut-out switch. Levanté International: 1 300 664 768 www.levanteinternational.com.au 6

WARRANTY CLAIM: IMPORTANT: To validate your product warranty, you must keep your panel heater receipt as proof of purchase and provide it with the heater when making a warranty claim. WARRANTY CONDITIONS Your Levanté electric panel heater comes with a 2 YEAR WARRANTY. Any replacement of faulty parts or repairs of any kind must be carried out by a qualified person and authorised by Levanté International Pty Ltd or their approved representative. Failure to do so will VOID the WARRANTY. Levanté International Pty. Ltd. reserve the right to reject any warranty claim deemed to be false. Retailers must have warranty claims authorised by a representative of Levanté International. If you believe your product to be faulty and under warranty you are required to do the following: 1. Return the product, at your expense, to the place of purchase for assessment by an authorised representative of Levanté International. 2. This may require leaving the product at the place of purchase. 3. If the product is deemed faulty and under warranty, the place of purchase of the product will order a replacement heater to which Levanté International, at our cost, will deliver the heater to the place of purchase. 4. The consumer will then be required, at their cost, to pick up the replacement heater from the place of purchase. 5. If the heater is faulty but not deemed to be under warranty, an explanation will be provided to the consumer and that the faulty heater can be picked up by the customer from the place of purchase. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. If you have any queries regarding your product or its warranty please contact: Levanté International Pty Ltd 80-84 Burlington St Oakleigh VIC 3166 P: 1 300 664 768 E: sales@levanteinternational.com.au Levanté International: 1 300 664 768 www.levanteinternational.com.au 7

Levanté International: 1 300 664 768 www.levanteinternational.com.au 8