FT1000S BASE FLIGHT-TYPE DISHWASHER

Similar documents
FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT1000 FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT900 FLIGHT-TYPE DISHWASHER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900BD FLIGHT-TYPE DISHWASHER

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER

FT SERIES FT1000e ELECTRIC

CLPS86eN-BAS DISHWASHER

CL64eN-BAS DISHWASHER

CL44eN-BAS DISHWASHER

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

CLCS76eN-BAS DISHWASHER

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

C44A/C44AW DISHWASHER

CL64T INDUSTRIAL TOTE WASHER

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CLCS76eN-EGR ENERGY RECOVERY DISHWASHER

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

CLPS66eN-EGR ENERGY RECOVERY/CLPS66eN-ADV DISHWASHER

CL64eN-EGR ENERGY RECOVERY/CL64eN-ADV DISHWASHER

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

Standard Features. Performance/Capacities

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

LXGeR and LXGePR GLASSWASHER

Models. Options. Standard Features. LoH 2 O

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

Model 80 DRHDPW 44 Single Tank with 36 Heavy Duty Prewash High Temperature Rack Conveyor Dishwashing Machine with

UW50 UTENSIL/PAN WASHER

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

VENTLESS DOOR-TYPE DISHWASHER

UW50 UTENSIL WASHER MODEL. FORM Rev. J (July 2013) (Electric machines only)

MODEL 86 PW MODEL 86 PW RACK CONVEYOR STANDARD FEATURES SPECIFIER STATEMENT. Project Item No. Quantity

K-76 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-66 SERIES. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

K-86 SERIES. Exclusive Features: Standard Features: ENERGY STAR Qualified. Options: Models:

K-86 SERIES HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

84 Series 84, 106 PW, 110 FFPW, 120 HDPW High-Temperature Rack Conveyor Dishwashing Machine

K-66 SERIES HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-64 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-44 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

B-US 281 LPW HOT WATER SANITIZING FLIGHT-TYPE WAREWASHERS. Standard Features: Options:

STERO SD3. Door-Type Dishwasher MODEL: ML

AM-14/AM-14C DISHWASHERS

LXeR and LXePR HOT AND COLD

DV The clean solution. Special Features: Standard Features: Options: HOT WATER SANITIZING DOOR-TYPE DISHWASHER

TURBOWASH TM... Pot and Pan Sink

LXe HOT AND COLD HOT AND COLD MODELS STANDARD FEATURES ACCESSORIES STANDARD VOLTAGES OPTIONS AT EXTRA COST. Item # Quantity C.S.I.

CLe-series Dishwashers

Device and Duo Rinse r/hr. Warewashing

BASIL 6700 TUNNEL CAGE WASHER

TURBOWASH TM... Pot and Pan Sink

MODEL AM14 & AM14C DISHWASHERS

BASIL 6000 TUNNEL CAGE WASHER

GIRTON CABINET WASHER MODEL 794A

UNDERCOUNTER DISHWASHER

CLe-series Dishwashers

AM SELECT WAREWASHER. The ENERGY STAR rated door-type AM Select warewasher is the only warewasher you need.

I N ST R UC T I ON C-LINE A, W, & AW DISHWASHERS MODEL R-L OPERATION L-R OPERATION C44A ML ML CRS66A ML ML-38948

The clean solution HOT WATER SANITIZING MULTIPLE-TANK FLIGHT TYPE WAREWASHERS B-M74 SERIES. Special Features: Standard Features: Optional Features:

Standard Features. Performance/Capacities. Operating Capacity Racks per hour. Hi-temp sanitization Chemical sanitization

Flight Type Dishwashers

K Tronic Series Installation and Start Up Checkout Procedure.

green&clean multi-rinse Rack Type, Energy Saving Device, medium

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

electric, 150r/h, R>L Warewashing Warewashing green&clean multi-rinse Rack Type, Energy Saving Device, large dryer, electric, 150r/h, R>L

Food Service Establishment Plan Review Form

Version 7 1/ LXP

Version 7 1/ LX

AM SELECT DISHWASHERS

STERO SD1. Low Temp Dishwasher MODEL: ML

A DIVISION OF THE LEGACY COMPANIES PRICE GUIDE. Effective Date January 1, 2014

701 s. RIDGE AVENUE TROY, OHIO FORM Rev. D (Dec. 2009)

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014

A DIVISION OF THE LEGACY COMPANIES PRICE GUIDE. Effective Date January 1, 2015

COMMERCIAL DISHWASHER 2016 PRODUCT CATALOG

STERO ER-94S/SC RACK CONVEYOR SERIES

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

Owner s Manual. Keep with machine for reference CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

Warewashing Contents. NT & TAS - For orders in these states please add 5% transport surcharge to your purchase price

electric, 150 r/h, left>right Dishwashing Dishwashing Multi-rinse Rack Type Dishwasher with Energy Saving Device, electric, 150 r/h, left>right

Operation. Operation. Hood-type High Temperature Dishwasher LISTED. Model: DH5000 Series

The clean solution HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS K-M54 SERIES. Special Features: Standard Features: Optional Features:

! ATTENTION INSTALLER! THIS DISHWASHER IS EQUIPPED WITH A CONDENSATE REMOVAL VENT SHROUD WHICH WAS SHIPPED SEPARATELY IN ITS OWN PACKAGING.

MODEL CMA-180UC PARTS MANUAL Rev 1.18

FLIGHT TYPE DISHWASHER

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Transcription:

Item # Quantity C.S.I. Section 11400 FLIGHT-TYPE DISHER STANDARD FEATURES Pumped rinse system (pressure gauge not required) Water usage 58 gph Digital controls with machine diagnostics Low temperature alert Single point vent location 31" access on prewash and power wash chambers; 20" access on dual rinse chamber Start and stop switches at both ends Doors open indicator Drains open indicator Door interlocks 3 1 2 H.P. prewash, and 5 H.P. power wash pump motors, all TEFC Capless wash arms Easy to remove stainless steel scrap pans and baskets 30" wide conveyor belt Dual Rinse Front and rear panels Variable speed conveyor DIRECTION OF OPERATION Right to Left Left to Right VOLTAGE 208/60/3 240/60/3 480/60/3 Other voltages available consult factory MODEL FT1000S Base Flight-Type Dishwasher OPTIONS AT EXTRA COST Electric Tank Heat Steam Tank Heat Booster Heater Electric Steam 6" higher than standard chamber Multiple conveyor choices Circuit breakers Security packages Other options available, consult factory ACCESSORIES Flanged feet Water hammer arrestor/prv (installed by others) Drain water tempering kit (installed by others) Vent connection kit Specifications, Details and Dimensions on Inside and Back. LA Research Report M660004 Complies with EPA Reduction of Lead in Drinking Water Act 2014 Meets requirements of ASSE Standard No. 1004 FLIGHT-TYPE DISHER F40353 FT1000S Base Flight-Type Dishwasher Page 1 of 12

FLIGHT-TYPE DISHER DESIGN: Fully automatic, flight-type dish machine consisting of a load section, power recirculating prewash, power wash, and dual rinse/final rinse section. Included with each machine will be flexible plastic strip curtains to control overspray. CONSTRUCTION: Stainless steel tank and chambers with No. 3 polish on appearance surfaces. Frame, legs and feet to be constructed of stainless steel. Inspection doors to be chamber width. PUMPS: Recirculating stainless steel pumps with stainless steel impellers. Pump housing has easy to remove coverplate for access to impeller. Wash pumps are self-draining. MOTORS: Totally enclosed fan cooled (TEFC) design with overload protection. Pump motors to be 3 1 2 H.P. for prewash, 5 H.P. for power wash, and conveyor motor to be 1 3 H.P. Available in electrical specifications of 208/60/3, 240/60/3 and 480/60/3. CONTROLS: A stainless steel control center with electronic digital controls mounted at eye level. Power On/Off and Start/Stop switches integrated into keypad. Digital display indicates door(s) open, low temperature alert, tanks/final rinse temperatures and other pertinent operating data. Additional Start/ Stop switches are located at each end of machine. Conveyor speed button to be included on the control center to provide for the adjustable speed conveyor. FLIGHT-TYPE CONVEYOR: Stainless steel side links, tie rods and conveyor tracks. Injection molded, resilient Duraflex flight links. VENT: Indirect vent connection with integral powered fan. RECIRCULATING PRE SECTION: Prewash compartment is fitted with upper and lower wash arms. Large removable one piece perforated stainless steel screen sloped downward to deep stainless steel scrap basket. TANK HEAT: Power wash and dual rinse tank water temperatures are thermostatically controlled. Low water protection is provided. Specify either electric or steam heat. FINAL RINSE: Easily removed final rinse arms. CONVEYOR DRIVE UNIT: Powered by a 1 3 H.P. motor. Trip mechanism provided on unload section. Jam protection is provided by load sensing switch at drive platform. Conveyor speed adjustment of 4 feet per minute to 6.3 feet per minute is provided on the digital display keypad. DRAINS: Manual, hand-operated, located at each tank. Page 2 of 12 F40353 FT1000S Base Flight-Type Dishwasher

FLIGHT-TYPE DISHER No other control system allows easier monitoring. The digital controls are placed in a convenient panel that lets operators verify proper operation and temperatures at a glance. Digital display indicates the unit is on, and confirms that the doors are closed. Automatic door interlocks prevent the pump and conveyor from operating if the doors are open. Easy-to-read digital display indicates accurate temperatures of the 160 F wash, 160 F dual rinse and 180 F final rinse critical for proper HACCP system record-keeping. Stainless steel pump is built for long life. The stainless steel pump housing and impeller offer greater durability and long life. The pump motor is totally enclosed and fan cooled (TEFC) to protect it from water spray during dishroom clean-up. Scrap baskets capture food particles and are easy to clean. The sloped screens that carry scraps to the scrap baskets are steeper, so less soil gets into the tanks. The basket opening is larger for easy cleaning and basket handles have been designed for easy lift-out access. The load section also features a removable scrap basket for ease of cleaning. All scrap baskets and strainers are stainless steel for strength and durability. The FT1000 Series saves water and energy. The unit has the lowest water and energy consumption in the industry, yet provides effective cleaning and sanitizing that meets NSF International requirements. This is achieved through a carefully balanced ratio of water flow to pressure. Insulated doors and thermal layered curtains also reduce heat loss. The unit s 58 gallons per hour rinse flow rate saves both water and the energy to heat it. Wider, variable speed conveyor offers increased throughput. The conveyor on the FT1000 Series is wider so it can handle more ware. Result: more volume and versatility, quicker work. Its speed is servicer adjustable for the type of ware, soiled condition, or workforce requirements. It runs at 4-6.3 feet per minute. Self-draining wash pumps help keep water clean. Pumps are self-draining when the machine is shut down, so there is no residual water left in the pumps. Installation is quick and easy with modular design, minimal wiring connections, and single point vent. Modular design means the FT1000 installs quickly and reliably. The control panel is already in place, premounted to the dual rinse/final rinse section. Wiring connections are minimal, and there is only a single vent, saving time and expense. The control box uses a single plane circuitry design for easy accessibility during installation and service. The FT1000 is ready to run quickly. F40353 FT1000S Base Flight-Type Dishwasher Page 3 of 12

ELECTRIC L-R P1 55 3/16" 44 9/16" P1 37 1/2" E1 E5 E2 E6 E3 E7 E4 E8 18 3/4" 21 3/4" 55 11/16" 63 3/8" 9 15/16" 99 1/16" E1 E2 E3 E4 E5 E6 E7 E8 11 13/16" 3 15/16" OVER FRAME "A" LOAD "B" 5' 1" UNLOAD "C" 3" 35 7/16" 35 7/16" 25 9/16" 5 3/4" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 6" AIR GAP 7 7/8" LOAD PRE- POWER AUX FNL UNLOAD 81 7/8" 89 3/8" SEE NOTE (d) 62 3/4" 36 1/2" DIRECTION OF OPERATION 36 1/4" 6" FLOOR LINE FLOOR LINE NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 40 3/8" 44 13/16" SEE NOTE (a) 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP MODEL NO. "A" "B" "C" FT1016S (5.5'-5'-5.5') FT1017S (6.5'-5'-5.5') FT1018S (7.5'-5'-5.5') FT1018S (5.5'-5'-7.5') FT1019S (6.5'-5'-7.5') FT1020S (7.5'-5'-7.5') FT1020S (5.5'-5'-9') FT1021S (6.5'-5'-9') FT1022S (7.5'-5'-9') FT1022S (5.5'-5'-11') FT1023S (6.5'-5'-11') FT1024S (7.5'-5'-11') FT1025S (5.5'-5'-15') FT1026S (6.5'-5'-15') FT1027S (7.5'-5'-15') FT1027S (5.5'-5'-17') FT1028S (6.5'-5'-17') FT1029S (7.5'-5'-17') 16' 2-15/16" 17' 2-11/16" 18' 2-17/32" 18' 2-7/16" 19' 2-3/16" 20' 2-1/32" 19' 10-3/16" 20' 9-15/16" 21' 9-25/32" 21' 9-13/16" 22' 9-9/16" 23' 9-13/32" 25' 5-1/8" 26' 4-7/8" 27' 4-23/32" 27' 4-11/16" 28' 4-7/16" 29' 4-9/32" 5' 6-15/16" 5' 7" 6' 6-11/16" 5' 7" 7' 6-17/32" 5' 7" 5' 6-15/16" 7' 6-1/2" 6' 6-11/16" 7' 6-1/2" 7' 6-17/32" 7' 6-1/2" 5' 6-15/16" 9' 2-1/4" 6' 6-11/16" 9' 2-1/4" 7' 6-17/32" 9' 2-1/4" 5' 6-15/16" 11' 1-7/8" 6' 6-11/16" 11' 1-7/8" 7' 6-17/32" 11' 1-7/8" 5' 6-15/16" 14' 9-3/16" 6' 6-11/16" 14' 9-3/16" 7' 6-17/32" 14' 9-3/16" 5' 6-15/16" 16' 8-3/4" 6' 6-11/16" 16' 8-3/4" 7' 6-17/32" 16' 8-3/4" NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" Page 4 of 12 F40353 FT1000S Base Flight-Type Dishwasher

ELECTRIC L-R SERVICE CONNECTION WITH CIRCUIT BREAKERS (2) SERVICE CONNECTIONS AS SHOWN BELOW MOTORS, CONTROLS & BOOSTER HEAT (TB1) 208/60/3 87.7 125 125 240/60/3 85.2 125 125 480/60/3 47.9 60 60, DUAL RINSE HEAT (TB2) DEVICE 208/60/3 129.0 175 175 240/60/3 123.2 150 150 480/60/3 61.5 80 80 SERVICE CONNECTION W/O CIRCUIT BREAKERS (4) SERVICE CONNECTIONS AS SHOWN BELOW ELECTRIC TANK HEAT, DUAL RINSE (1) 7 KW CONNECTION AS SHOWN BELOW 208/60/3 21.0 25 25 240/60/3 20.0 25 25 480/60/3 10.0 15 15 ELECTRIC TANK HEAT, (1) 36 KW CONNECTION AS SHOWN BELOW 208/60/3 108.0 125 125 240/60/3 103.2 125 125 480/60/3 51.5 70 70 ELECTRIC BOOSTER (1) 18 KW CONNECTION AS SHOWN BELOW 208/60/3 54.0 70 70 240/60/3 51.5 70 70 480/60/3 25.8 35 35 MOTORS AND CONTROLS DEVICE 208-240/60/3 33.7 45 45 480/60/3 22.1 30 30 Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. VENTILATION NOTES: (d) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, E4 ELECTRIC TANK HEAT CONNECTION, TANK, 36 KW. 1-1/4" CONDUIT. 79-1/8" AFF E5 ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 7KW. E6 ELECTRIC CONNECTION, BOOSTER, 18KW. WITH CIRCUIT BREAKERS: E7 ELECTRIC CONNECTION, MOTORS, CONTROLS, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED). (TB1) 2" CONDUIT, 79-1/8" AFF E8 ELECTRIC CONNECTION, HEAT & DUAL RINSE HEAT (TB2) 1-1/4" CONDUIT, 79-1/8" AFF PLUMBING CONNECTIONS: P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF Pressure gauge not required on pumped rinse machines. MODEL: ELECTRIC L-R OPERATION 00-949511 REV A2 F40353 FT1000S Base Flight-Type Dishwasher Page 5 of 12

ELECTRIC R-L 52" 44 9/16" P1 P1 55 11/16" 63 3/8" 23 3/4" 18 3/4" 37 1/2" E1 E5 E2 E6 E3 E7 E4 E8 9 15/16" 99 1/16" 11 13/16" E1 E2 E3 E4 E5 E6 E7 E8 7 7/8" OVER FRAME "A" 3 15/16" UNLOAD "C" 5' 1" LOAD "B" 25 9/16" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 35 7/16" 5 3/4" 35 7/16" 3" 6" AIR GAP 89 3/8" SEE NOTE (d) 81 7/8" UNLOAD FNL AUX POWER PRE- LOAD 62 3/4" 36 1/4" DIRECTION OF OPERATION 36 1/2" 6" NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 40 3/8" FLOOR LINE 44 13/16" SEE NOTE (a) 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP MODEL NO. "A" "B" "C" FT1016S (5.5'-5'-5.5') FT1017S (6.5'-5'-5.5') FT1018S (7.5'-5'-5.5') FT1018S (5.5'-5'-7.5') FT1019S (6.5'-5'-7.5') FT1020S (7.5'-5'-7.5') FT1020S (5.5'-5'-9') FT1021S (6.5'-5'-9') FT1022S (7.5'-5'-9') FT1022S (5.5'-5'-11') FT1023S (6.5'-5'-11') FT1024S (7.5'-5'-11') FT1025S (5.5'-5'-15') FT1026S (6.5'-5'-15') FT1027S (7.5'-5'-15') FT1027S (5.5'-5'-17') FT1028S (6.5'-5'-17') FT1029S (7.5'-5'-17') FLOOR LINE 16' 2-15/16" 17' 2-11/16" 18' 2-17/32" 18' 2-7/16" 19' 2-3/16" 20' 2-1/32" 19' 10-3/16" 20' 9-15/16" 21' 9-25/32" 21' 9-13/16" 22' 9-9/16" 23' 9-13/32" 25' 5-1/8" 26' 4-7/8" 27' 4-23/32" 27' 4-11/16" 28' 4-7/16" 29' 4-9/32" 5' 6-15/16" 5' 7" 6' 6-11/16" 5' 7" 7' 6-17/32" 5' 7" 5' 6-15/16" 7' 6-1/2" 6' 6-11/16" 7' 6-1/2" 7' 6-17/32" 7' 6-1/2" 5' 6-15/16" 9' 2-1/4" 6' 6-11/16" 9' 2-1/4" 7' 6-17/32" 9' 2-1/4" 5' 6-15/16" 11' 1-7/8" 6' 6-11/16" 11' 1-7/8" 7' 6-17/32" 11' 1-7/8" 5' 6-15/16" 14' 9-3/16" 6' 6-11/16" 14' 9-3/16" 7' 6-17/32" 14' 9-3/16" 5' 6-15/16" 16' 8-3/4" 6' 6-11/16" 16' 8-3/4" 7' 6-17/32" 16' 8-3/4" NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" Page 6 of 12 F40353 FT1000S Base Flight-Type Dishwasher

ELECTRIC R-L SERVICE CONNECTION WITH CIRCUIT BREAKERS (2) SERVICE CONNECTIONS AS SHOWN BELOW MOTORS, CONTROLS & BOOSTER HEAT (TB1) 208/60/3 87.7 125 125 240/60/3 85.2 125 125 480/60/3 47.9 60 60, DUAL RINSE HEAT (TB2) DEVICE 208/60/3 129.0 175 175 240/60/3 123.2 150 150 480/60/3 61.5 80 80 SERVICE CONNECTION W/O CIRCUIT BREAKERS (4) SERVICE CONNECTIONS AS SHOWN BELOW ELECTRIC TANK HEAT, DUAL RINSE (1) 7 KW CONNECTION AS SHOWN BELOW 208/60/3 21.0 25 25 240/60/3 20.0 25 25 480/60/3 10.0 15 15 ELECTRIC TANK HEAT, (1) 36 KW CONNECTION AS SHOWN BELOW 208/60/3 108.0 125 125 240/60/3 103.2 125 125 480/60/3 51.5 70 70 ELECTRIC BOOSTER (1) 18 KW CONNECTION AS SHOWN BELOW 208/60/3 54.0 70 70 240/60/3 51.5 70 70 480/60/3 25.8 35 35 MOTORS AND CONTROLS DEVICE 208-240/60/3 33.7 45 45 480/60/3 22.1 30 30 Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. VENTILATION NOTES: (d) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, E4 ELECTRIC TANK HEAT CONNECTION, TANK, 36 KW. 1-1/4" CONDUIT. 79-1/8" AFF E5 ELECTRIC TANK HEAT CONNECTION, DUAL RINSE TANK, 7KW. E6 ELECTRIC CONNECTION, BOOSTER, 18KW. WITH CIRCUIT BREAKERS: E7 ELECTRIC CONNECTION, MOTORS, CONTROLS, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED). (TB1) 2" CONDUIT, 79-1/8" AFF E8 ELECTRIC CONNECTION, HEAT & DUAL RINSE HEAT (TB2) 1-1/4" CONDUIT, 79-1/8" AFF PLUMBING CONNECTIONS: P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF Pressure gauge not required on pumped rinse machines. MODEL: ELECTRIC R-L OPERATION 00-949510 REV A2 F40353 FT1000S Base Flight-Type Dishwasher Page 7 of 12

STEAM L-R P6 15 11/16" P1 P4 14 11/16" P5 5 15/16" P6 33 3/8" 2 15/16" P6 55 3/16" 44 9/16" 11 9/16" P5 21 3/4" P1 23" P7 23 1/8" P3 P4 37 1/2" E1 E2 E3 18 3/4" 28 15/16" 55 11/16" 63 3/8" 9 15/16" 99 1/16" E1 E2 E3 11 13/16" P7 28 7/16" P3 38 1/4" 3 15/16" OVER FRAME "A" LOAD "B" 5' 1" 3" 35 7/16" 35 7/16" 25 9/16" 5 3/4" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" UNLOAD "C" 6" AIR GAP 7 7/8" LOAD PRE- POWER AUX FNL UNLOAD 81 7/8" 89 3/8" SEE NOTE (e) 62 3/4" 36 1/2" DIRECTION OF OPERATION 36 1/4" 6" FLOOR LINE Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. Pressure gauge not required on pumped rinse machines. Page 8 of 12 F40353 FT1000S Base Flight-Type Dishwasher

STEAM L-R SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS MOTORS AND CONTROLS DEVICE 208-240/60/3 33.7 45 45 480/60/3 22.1 30 30 MODEL NO. "A" "B" "C" FT1016S (5.5'-5'-5.5') FT1017S (6.5'-5'-5.5') FT1018S (7.5'-5'-5.5') FT1018S (5.5'-5'-7.5') FT1019S (6.5'-5'-7.5') FT1020S (7.5'-5'-7.5') FT1020S (5.5'-5'-9') FT1021S (6.5'-5'-9') FT1022S (7.5'-5'-9') FT1022S (5.5'-5'-11') FT1023S (6.5'-5'-11') FT1024S (7.5'-5'-11') FT1025S (5.5'-5'-15') FT1026S (6.5'-5'-15') FT1027S (7.5'-5'-15') FT1027S (5.5'-5'-17') FT1028S (6.5'-5'-17') FT1029S (7.5'-5'-17') NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE 16' 2-15/16" 17' 2-11/16" 18' 2-17/32" 18' 2-7/16" 19' 2-3/16" 20' 2-1/32" 19' 10-3/16" 20' 9-15/16" 21' 9-25/32" 21' 9-13/16" 22' 9-9/16" 23' 9-13/32" 25' 5-1/8" 26' 4-7/8" 27' 4-23/32" 27' 4-11/16" 28' 4-7/16" 29' 4-9/32" 40 3/8" 5' 6-15/16" 5' 7" 6' 6-11/16" 5' 7" 7' 6-17/32" 5' 7" 5' 6-15/16" 7' 6-1/2" 6' 6-11/16" 7' 6-1/2" 7' 6-17/32" 7' 6-1/2" 5' 6-15/16" 9' 2-1/4" 6' 6-11/16" 9' 2-1/4" 7' 6-17/32" 9' 2-1/4" 5' 6-15/16" 11' 1-7/8" 6' 6-11/16" 11' 1-7/8" 7' 6-17/32" 11' 1-7/8" 5' 6-15/16" 14' 9-3/16" 6' 6-11/16" 14' 9-3/16" 7' 6-17/32" 14' 9-3/16" 5' 6-15/16" 16' 8-3/4" 6' 6-11/16" 16' 8-3/4" 7' 6-17/32" 16' 8-3/4" GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. (d) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE AT THE DISHER, CONTACT SALES ENGINEERING. VENTILATION NOTES: (e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF WITH & W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, FLOOR LINE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 44 13/16" SEE NOTE (a) 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP PLUMBING CONNECTIONS: P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF P3 COMMON STEAM CONNECTION (TANK HEAT & STEAM BOOSTER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE) see note (d). P4 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF P5 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF P6 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS. 3/4" FPT, 11" AFF P7 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF MODEL: STEAM L-R OPERATION 00-949511 REV A2 VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF F40353 FT1000S Base Flight-Type Dishwasher Page 9 of 12

STEAM R-L 52" 44 9/16" P1 14 5/8" P4 5 7/8" P5 53 3/8" P6 P3 P5 11 5/8" P7 23 1/16" P1 P4 22 5/8" P6 15 11/16" P6 23 3/4" 28 15/16" 55 11/16" 63 3/8" 23 1/8" 18 3/4" 37 1/2" E1 E2 E3 9 15/16" 99 1/16" 11 13/16" E1 E2 E3 28 7/16" P7 38 1/4" P3 7 7/8" OVER FRAME "A" 3 15/16" UNLOAD "C" 5' 1" LOAD "B" 25 9/16" EXHAUST HOOD SUPPLIED BY OTHERS 23 3/4" 35 7/16" 5 3/4" 35 7/16" 3" 6" AIR GAP 89 3/8" SEE NOTE (e) 81 7/8" UNLOAD FNL AUX POWER PRE- LOAD 62 3/4" 36 1/4" DIRECTION OF OPERATION 36 1/2" 6" FLOOR LINE Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes. Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations vary, some methods are shown on this drawing. Pressure gauge not required on pumped rinse machines. Page 10 of 12 F40353 FT1000S Base Flight-Type Dishwasher

STEAM R-L MODEL NO. "A" "B" "C" FT1016S (5.5'-5'-5.5') FT1017S (6.5'-5'-5.5') FT1018S (7.5'-5'-5.5') FT1018S (5.5'-5'-7.5') FT1019S (6.5'-5'-7.5') FT1020S (7.5'-5'-7.5') FT1020S (5.5'-5'-9') FT1021S (6.5'-5'-9') FT1022S (7.5'-5'-9') FT1022S (5.5'-5'-11') FT1023S (6.5'-5'-11') FT1024S (7.5'-5'-11') FT1025S (5.5'-5'-15') FT1026S (6.5'-5'-15') FT1027S (7.5'-5'-15') FT1027S (5.5'-5'-17') FT1028S (6.5'-5'-17') FT1029S (7.5'-5'-17') NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 13/16" MODEL: STEAM R-L OPERATION 00-949510 REV A2 SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS MOTORS AND CONTROLS DEVICE 208-240/60/3 33.7 45 45 480/60/3 22.1 30 30 NOTE: REFER TO LATEST EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES FOR PROPER CLEARANCE NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED. 35" 16' 2-15/16" 17' 2-11/16" 18' 2-17/32" 18' 2-7/16" 19' 2-3/16" 20' 2-1/32" 19' 10-3/16" 20' 9-15/16" 21' 9-25/32" 21' 9-13/16" 22' 9-9/16" 23' 9-13/32" 25' 5-1/8" 26' 4-7/8" 27' 4-23/32" 27' 4-11/16" 28' 4-7/16" 29' 4-9/32" 40 3/8" FLOOR LINE 44 13/16" SEE NOTE (a) 5' 6-15/16" 5' 7" 6' 6-11/16" 5' 7" 7' 6-17/32" 5' 7" 5' 6-15/16" 7' 6-1/2" 6' 6-11/16" 7' 6-1/2" 7' 6-17/32" 7' 6-1/2" 5' 6-15/16" 9' 2-1/4" 6' 6-11/16" 9' 2-1/4" 7' 6-17/32" 9' 2-1/4" 5' 6-15/16" 11' 1-7/8" 6' 6-11/16" 11' 1-7/8" 7' 6-17/32" 11' 1-7/8" 5' 6-15/16" 14' 9-3/16" 6' 6-11/16" 14' 9-3/16" 7' 6-17/32" 14' 9-3/16" 5' 6-15/16" 16' 8-3/4" 6' 6-11/16" 16' 8-3/4" 7' 6-17/32" 16' 8-3/4" 22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS NOTE: CLEARANCE FROM WALL 24" RECOMMED, 6" WITH DETERGENT DISPENSER ON THE TOP GENERAL NOTES: (a) THE CONTROL BOX IS ATTACHED TO THE CENTER SECTION AND IS ROTATED 90 DEGREES FOR SHIPPING. AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKEN FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMATION ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. ELECTRICAL WARNING: SERVICE WIRE TEMPERATURE RATING: 90C. PLUMBING NOTES: RECOMMED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS. (b) RECOMMED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHER IS 30-35 PSI. (c) WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN HOT WATER LINE AT SERVICE CONNECTION. (d) IF STEAM PRESSURE IS UNDER 10 PSI FLOWING PRESSURE AT THE DISHER, CONTACT SALES ENGINEERING. VENTILATION NOTES: (e) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM THE UNIT TO YIELD 81-7/8" CLEARANCE FOR DOORWAYS. COMMON ON ALL MODELS: E1 ELECTRIC CONNECTION, DETERGENT AND RINSE FEEDERS (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF E2 ELECTRIC CONNECTION, VENT FAN CONTROL. (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF WITH & W/O CIRCUIT BREAKERS: E3 ELECTRIC CONNECTION, MOTORS & CONTROLS, PLUMBING CONNECTIONS: P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 110 F WATER, 1" FPT, 5-1/2" AFF see notes (b) AND (c). COMMON DRAIN CONNECTION. TWO CONNECTION LOCATIONS; MAY BE DRAINED TO EITHER OF UNIT, PLUG OPPOSITE. 2" FPT. 7" AFF P3 COMMON STEAM CONNECTION (TANK HEAT & STEAM BOOSTER). 1-1/2" FPT, 4-3/8" AFF (10-45 PSI FLOWING PRESSURE) see note (d). P4 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF P5 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF P6 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 2 CONNECTIONS. 3/4" FPT, 11" AFF P7 CONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF VENTILATION REQUIREMENTS: OF 24" SQUARE VENT HOOD WITH 6 INCH AIR GAP CAPABLE OF PROVIDING 550 CFM EXHAUST AT STANDARD AIR CONDITIONS (VENT HOOD SUPPLIED AND INSTALLED BY OTHERS). 95-3/8" AFF F40353 FT1000S Base Flight-Type Dishwasher Page 11 of 12

FLIGHT-TYPE DISHER FT (flight type) Models many additional variations of these model specifications are available. Engineering data furnished on request. Numbers in parentheses, after model number from left to right, represent length in feet of the following respectively; Loading section, Washing and Power Rinsing sections, Unloading section. FT1000S Base Series (5.5, 7.5, 9 Load / 5 Center / 5.5, 7.5, 9 Unload) Machine Ratings (Mechanical) Conveyor Speed Feet per minute 4-6.3 Dishes per Hour 10,611 Motor Horsepower Pre-Wash - 3 1 2; Wash - 5; Dual Rinse - 1 6; Final Rinse - 1 2; Conveyor - 1 3 Tank Capacity Gallons Pre-Wash - 40; Wash - 40; Dual Rinse - 7.2 Rate of Final Rinse Gallons per minute (Pumped rinse).97 Final Rinse Consumption Gallons per hour (Pumped rinse) 58 Exhaust Requirements Cubic Feet per minute 550 (at standard air conditions) Latent/Sensible Heat BTU per hour Electric - Latent: 67,000 / Sensible: 28,700 Steam - Latent: 80,400 / Sensible: 34,500 Electric Heat Requirements Tank Heat - Kilowatt (Regulated) Optional Electric Booster - Kilowatt Steam Heat Requirements Steam Consumption Tank Heat - Pounds per hour - maximum (Regulated) - based on 10 to 45 PSI steam at the machine Optional Steam Booster - Pounds per hour - maximum - based on 20 PSI steam, 110 F incoming water raised to 185 F (75 F rise) (180 F minimum) Disconnect switches are recommended for each power circuit connected to dishwasher. These disconnect switches are NOT furnished by Hobart and should be installed by the electrical contractor at the time of installation. Circuit breakers optional at extra cost. Total tank heat - 43KW (Wash and Dual Rinse) 18KW - 110 F incoming water raised to 185 F (75 F rise) (180 F minimum) 171 lbs./160 F Wash minimum - 160 F Dual Rinse minimum 47 lbs./180 F Final Rinse minimum Peak Rate of Drain Flow Gallons per minute Initial rate with full tanks 38 Shipping Weight Crated Varies by individual model - consult your Hobart representative As continued product improvement is a policy of Hobart, specifications are subject to change without notice. Page 12 of 12 F40353 (REV. 09/14) F40353 FT1000S Base Flight-Type Dishwasher LITHO IN U.S.A. (H-01)