Date of Authorization October 30, 2003 BMEC Authorization BMEC #

Similar documents
BUILDING MATERIALS EVALUATION COMMISSION (BMEC) AUTHORIZATION REPORT

Date of Authorization May 26, 2005 BMEC Authorization BMEC Application # A

Date of Authorization JUNE 24, 2004 BMEC Authorization BMEC # AUTHORIZATION REPORT - SafeSIGN Photoluminescent EXIT Signs

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

THE CORPORATION OF THE TOWNSHIP OF MUSKOKA LAKES BY-LAW NUMBER

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Combined Hand-Washing Systems

Planning and Building Department APPLICATION FOR CEMETERY EXPANSION BAYVIEW CEMETERY, 720, 726 AND 740 SPRING GARDENS ROAD

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Transportation Master Plan Schedule B Projects Road Name From To Description of Works Southcote Road Garner Road Twenty Road Extension

BUILDING CODE COMMISSION

Request Conditional Use Permit (Car Wash Facility) Staff Recommendation Approval. Staff Planner Jonathan Sanders

Amendment to the Green Roof Bylaw for Public and Separate School Board Buildings

SUBCHAPTER 6L - BARBER SHOPS

PROPOSED REGULATION OF THE STATE PUBLIC WORKS BOARD. LCB File No. R102-11

Agenda Item. Applicant Logan Virginia Properties, LLC Property Owners Byler Azalea, LLC & Gateway Free Will Baptist Chuch

THE REGIONAL MUNICIPALITY OF YORK BYLAW NO A bylaw to adopt Amendment No. 6 to the Official Plan for The Regional Municipality of York

THE REGIONAL MUNICIPALITY OF HALTON POLICE SERVICES BOARD BY-LAW

Six Mile Lake GFA Policies Official Plan Amendment

BUILDING CODE COMMISSION

Capital Projects Group Fire Extinguishers Specification

11 October 8, 2014 Public Hearing

Motion Controlled Apartment Building Corridor Lighting

Content Copy Of Original

Broward County Utility Connection Permit Part One Application for Plan Review

Fire District Dwelling Construction Requirements

City of Fort Lupton Site Plan Process

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

COUNCIL ORDER No

Design & Construction Standards, Revised January

150 Eighth Street Zoning By-law Amendment Application Preliminary Report

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

An Update on the Mandated Stormwater Initiative Chesapeake Bay TMDL

The Regional Municipality of Halton. Chair and Members of the Planning and Public Works Committee

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Request Conditional Use Permit (Automobile Service Station) Staff Recommendation Approval. Staff Planner Bill Landfair

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

Eco-Roof Incentive Program application: 6 Curity Avenue

Australian/New Zealand Standard

The definitions provided in , C.R.S., apply to these rules and regulations. The following additional definitions also apply:

DIVISION C ADMINISTRATIVE PROVISIONS

240 and 242 Finch Avenue West Zoning By-law Amendment Application Preliminary Report

Type Acceptance Report

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Occupancy Packet & Business License Application

Special attention should be given to new students, to students with special needs and to students enrolled in visiting classes.

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973

Building and Development

TECHNICAL COMMITTEE ON FIRE PUMPS

City of Fort Lupton Administrative Site Plan Process

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

The definitions provided in , C.R.S., shall apply to these rules and regulations. The following additional definitions shall also apply:

STATIONARY FOOD CART REQUIREMENTS

Request Conditional Rezoning (R-10 Residential & I-1 Light Industrial to Conditional I-1 Light Industrial) Staff Recommendation Approval

ONTARIO MUNICIPAL BOARD

Guide to Membership Assessments

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

BUILDING CODE COMMISSION

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:


20 & 50 Ashtonbee Road, 1920 & 1940 Eglinton Avenue East, and 880, 890 & 900 Warden Avenue Zoning Amendment Application Final Report

Food Service Plan Review Information

COUNTY COUNCIL OF PRINCE GEORGE'S COUNTY, MARYLAND SITTING AS THE DISTRICT COUNCIL 2010 Legislative Session. Council Members Dernoga and Olson

CCC 2018 GROUP A PROPOSED CHANGES TO THE I-CODES COLUMBUS COMMITTEE ACTION HEARINGS. April 15 23, 2018 Columbus Convention Center Columbus, Ohio

Non-Residential&Multi-Family PropertyCreditManual

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

STANDARDS UPDATE NOTICE (SUN) ISSUED: April 26, 2018

Request Major Retail Venue Signage Permit. Staff Recommendation Approval. Staff Planner Kevin Kemp

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

ALABAMA. Downloaded

In addition, Fire Protection and Business Support Information are included in the report.

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

Issue Update: Revised Recommended Language for Verification Contracts and Statements for Recycling Appliances and Vehicles

Request Modification of Conditions (Conditional Use Permit for a Church approved by City Council in 1989 & modified in 1990, 2010, and 2014)

BUILDING CODE COMMISSION

2 January 14, 2015 Public Hearing

THE CITY OF VAUGHAN BY-LAW BY-LAW NUMBER

IC Chapter Severe Weather Warning Sirens

11 August 14, 2013 Public Hearing APPLICANT: CREEDS RURITAN CLUB

CHAIR AND MEMBERS PLANNING & ENVIRONMENT COMMITTEE JOHN M. FLEMING MANAGING DIRECTOR, PLANNING AND CITY PLANNER

FIRE SERVICE FEATURES

Plumbing Lesson Four: Plumbing System Plan. Student Handouts

2.11 Submittal Guidelines for Emergency Evacuation Signs (2016)

AGENCY OF NATURAL RESOURCES Waterbury, Vermont ENVIRONMENTAL PROTECTION REGULATIONS CHAPTER 5 AIR POLLUTION CONTROL. Subchapter II.

TECHNICAL SEMINAR CARLETON UNIVERSITY OCT Gerry Landmesser CFAA-NCR President Mircom Group of Companies

HazLoc Essential Guides:

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

PG18.2 REPORT FOR ACTION. Eco-Roof Incentive Program application: 50 Drummond Street SUMMARY

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Artist Call for Expressions of Interest Port Kells Hall Mosaic Project RFEOI #

NFPA Fire Inspector I Study Guide

Chesapeake Bay Critical Area Conservation Plan

INTERNATIONAL STANDARD

2. What is required if I want to put some patio/bistro tables and chairs on the sidewalk and remove them at the end of each day?

Transcription:

Building Materials Evaluation Commission 777 Bay Street, 2 nd Floor Toronto, Ontario, M5G2E5 Tel: 416: 585. 4234 / Fax: 416. 585. 7531 www.obc.mah.gov.on.ca Date of Authorization October 30, 2003 BMEC Authorization BMEC #03-10-289 BMEC Application #A2003-14 BMEC Application A2005-20 Date of Amendment October 27, 2005 * Denoted October 27, 2005 Amendment AUTHORIZATION REPORT: Trap Guard Valve 1. Applicant 2. Manufacturing Facilities Proset Systems, Inc. Proset Plastics, Inc. 1355 Capital Circle 1355 Capital Circle Lawrenceville, Georgia Lawrenceville, Georgia 30043, USA 30043, USA Tel: (770) 339-1782 Proset Plastics, Inc. Fax: (770) 339-1784 519 Honeysuckle Road Web: www.trapguard.com Spartanburg, South Carolina 29303, USA 3. Description The Proset Systems, Inc. Trap Guard Valve is made of a soft, flexible elastomeric PVC material molded to a ridge PVC fitting in the shape of a duck s bill, open at the top with a special curl closure at the bottom. The Trap Guard Valve is used inside of an approved floor drain fixture. The smooth flexible Trap Guard Valve surface allows wastewater to open and adequately discharge the fixture through its interior and close after the wastewater discharges to prevent possible sewer gas emissions. Proset Systems, Inc. Page 1 of 5

4. Authorization requested The applicant sought a Building Materials Evaluation Commission (BMEC) authorization for the Trap Guard Valve as an equally effective means of providing a trap seal primer, with limitations, equivalent to the requirements of 1997 Ontario Building Code, Sentence 7.4.5.5.(1). 5. Assessment Reports and assessments provided by the applicant show that if the Trap Guard Valve is designed, performance tested and installed in accordance with the manufacturer's instructions and limitations and the specific terms and conditions stated in this authorization, the level of performance required by the 1997 Ontario Building ode will be provided. The reports submitted, and reviewed, but were not limited to: 1. Southern Building Code Congress International, Report Number 2218, copyrighted 2002. 2. Curney & Ivey Engineering Inc. Test Report, January 19, 2002, Subject Engineering Report 22007, Testing of Trap Guard. 3. Intertek Testing Services, Issued January 31, 2003, Revised March 26, 2003, Listing Report Number 478-3031903-01/03 A Model Proset Systems, Inc. Trap Guard Floor Drain. 4. Installation Instructions. 5. Letter of Approval, City of Philadelphia, July 3, 2003. 6. Letter of Approval, City of Winnipeg, July 21, 2003. * 7. Forest Mechanical Inc., Engineer s letter, dated August 18, 2005. 6. Authorization The Trap Guard Valve is authorized for use as an equally effective means of providing a trap seal primer, all other requirements pertaining to the installation are subject to the requirements of the 1997 Ontario Building Code; and subject to the following terms and conditions: Proset Systems, Inc. Page 2 of 5

A. Specific Terms & Conditions 1. This Authorization is valid only for Proset Systems, Inc. Trap Guard Valve, for 2", 3" and 4" diameter floor drain sizes. 2. The Proset Systems, Inc. Trap Guard Valve shall be installed flush with the finished floor. 3. If a Proset Systems, Inc. Trap Guard Valve is installed, then it shall not reduce the flow through a pipe by more than 10 percent. 4. The strainer which covers the Proset Systems, Inc. Trap Guard Valve shall have the following label Trap Guard Protection Inside ; the label shall be: (c) (d) permanently attached, waterproof, adhered in a manner that it does not obstruct the strainer s flow, and installed on a contrasting background. 5. The Proset Systems, Inc. Trap Guard Valve shall be accessible by removing the strainer top. 6. The Proset Systems, Inc. Trap Guard Valve shall not be installed in systems where the water temperature discharge is greater than 93.3 0 C (200 0 F) or higher. * 7. The Proset Systems, Inc. Trap Guard Valve may be installed in a floor drain system that complies with CSA B 79, or floor drains installed in conformance with the Building Code. 8. The Proset Systems, Inc. Trap Guard Valve shall not be installed where the discharge sewage or waste may damage or impair the fitting. B. General Conditions 1. The use of the Proset Systems, Inc. Trap Guard Valve as described in 6. A. Specific Terms and Conditions No. 1. must comply with the Building Code Act, 1992 as amended or re-enacted from time to time and except as specifically authorized herein, with the Ontario Building Code as amended or remade from time to time. Proset Systems, Inc. Page 3 of 5

2. A copy of this Authorization shall accompany each application for a building permit and shall be maintained on the site of the construction with the building permit. 3. The Applicant named in Part 1 hereof shall promptly notify the BMEC of: the failure of the Applicant, or of the material, system or building design that is the subject matter of this Authorization, to comply with any of the terms and conditions set out in 6. A. above; or the occurrence of any of the events described in Conditions 6. B. 4. and (ii) below. 4. The BMEC may amend or revoke this Authorization where it determines that: any change has been made to: i. the material, system or building design that is the subject matter of this Authorization; ii. iii. the address of the applicant specified in Part 1 of this Authorization; or, the ownership of the applicant specified in Part 1 of this Authorization. the use of the material, system or building design authorized herein; i. does not comply with the Building Code Act, 1992 or any relevant legislation as they may be amended or re-enacted from time to time; or ii. provides an unsatisfactory level of performance, in situ. (c) the Applicant, or the material, system or building design that is the subject matter of this Authorization, has failed to comply with any of the terms and conditions set out in this Authorization; or (d) any Ontario Building Code provision relevant to this Authorization has been amended or remade. Proset Systems, Inc. Page 4 of 5

5. W here the Commission receives additional information concerning the material, system or building design authorized herein, the Commission may review this Authorization and the Commission may after the review amend or revoke this Authorization as in the opinion of the Commission may be necessary. Dated at Toronto this 27 day of October 2005. BUILDING MATERIALS EVALUATION COMMISSION Edward Link, Vice-Chair Proset Systems, Inc. Page 5 of 5