MANUAL Oil Level Sensor

Similar documents
MANUAL Overflow sensor NVF-104/34-PF

MANUAL Overflow sensor NVF-104/34-PF

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

Inductive slot sensor

Technical Data. Dimensions

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Vibracon LVL-A* Level limit switch for liquids, compact design

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Technical Data. General specifications. Rated operating distance s n 5 mm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OPTIBAR P 1010/2010 C Supplementary instructions

OilSET-1000 (12 VDC)

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

Translation of the assembly instructions with operating instructions and technical appendix

FACTORY AUTOMATION HANDBUCH / MANUAL / MANUAL / MANUALE

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Original operating instructions Safety switch with guard locking AC901S AC902S

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

SET Installation and Operating Instructions. Level switch for one sensor

SET-2000 Hi Level/Oil

OPTIBAR DP 7060 Supplementary Instructions

SET-2000 Oil/Sludge 12 VDC

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

VERSAFLOW VORTEX Supplementary instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

OPTIWAVE X500 Supplementary Instructions

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Supplementary Installation and Operating Instructions. Category II2G

Instruction Manual. Electronic gas and smoke detector GRM

PEPPERL+FUCHS GmbH

Alarm system For oil-water separator

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Multipoint temperature sensor

Operating Instructions

Operating Manual MS220KA and MSR220KA

FSW300 Series Flow Switch

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

Flameproof Manual Call Points

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SCHMIDT LED Measured Value Display MD Instructions for Use

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Thermocouples and Resistance Thermometers

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

RT FLOW RATE TOTALISER

AND INSTALLATION MANUAL

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Operating Manual MS220DA

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Manual Isolating Barrier D461R1 (Revision 01)

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

4) Intrinsic Safety Certification

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Installationsmanual GWSL1100/2100, GWML3100

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

OilMatic Pro / 230 V AC

Instruction manual 640 Securiterre

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

Installation and Operating Instruction

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating Instructions!

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Manual Power relay SR853

Operating Instruction

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

EtherCAT Box Modules (EPxxxx-xxxx)

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

TTV 4500 / TTV 4500 HP / TTV 7000

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

USER MANUAL DIAGNOSTIC MODULE

Intrinsically Safe Transmitters, Option Code 2n

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

ATM Lighting sp. z o.o

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Functional Safety Manual Oil Leak Detector NAR300 System

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Transcription:

PROCESS AUTOMATION MANUAL Oil Level Sensor KVF-104-PF ISO9001 0102

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents 1 Safety... 2 1.1 General safety instructions...2 1.2 Used Symbols...3 1.3 Declaration of Conformity...3 1.4 Intended use...4 1.5 Delivery, Transport and Storage...4 1.6 Installation and Commissioning...5 1.7 Operation...6 1.8 Maintenance...6 1.9 Repair...6 1.10 Disposal...6 2 Product Specifications... 7 2.1 Function...7 2.2 Layout and dimensions...7 2.3 Product programm...8 3 Installation... 9 3.1 Mounting in oil/petrol separators...9 3.2 Connection...10 4 Operation... 11 4.1 Emptying/Disposing of the Container...11 5 Maintenance and Repair... 12 5.1 Sensor test...12 6 Troubleshooting... 13 6.1 Sensor Maintenance...13 7 Technical specifications... 14-1

Safety 1 Safety 1.1 General safety instructions Responsibility for planning, assembly, commissioning, operation, maintenance, and dismounting lies with the plant operator. Installation and commissioning of all devices must be performed by a trained professional only. Protection of operating personnel and the system is not ensured if the product is not used in accordance with its intended purpose. Laws and regulations applicable to the usage or the intended purpose must be observed. The devices are only approved for appropriate and intended use. Ignoring these instructions will void any warranty and absolve the manufacturer from any liability. The Declaration of Conformity, Certificate of Compliance, Statement of Conformity, EC-type-examination certificate and data sheets are an integral part of this document. The data sheet contains the electrical data of the Declaration of Conformity, the Certificate of Compliance and the EC-type-examination certificate. The documents mentioned are available from http://www.pepperl-fuchs.com or contact your local Pepperl+Fuchs representative. 2 -

Safety 1.2 Used Symbols Safety-relevant Symbols Danger! This symbol indicates an imminent danger. Non-observance will result in personal injury or death. Warning! This symbol indicates a possible fault or danger. Non-observance may cause personal injury or serious property damage. Caution! This symbol indicates a possible fault. Non-observance could interrupt the device and any connected systems and plants, or result in their complete failure. Informative Symbols Note! This symbol brings important information to your attention. Action This symbol indicates a paragraph with instructions. 1.3 Declaration of Conformity All products were developed and manufactured under observance of the applicable European standards and guidelines. Note! A Declaration of Conformity can be requested from the manufacturer. The product manufacturer, Pepperl+Fuchs GmbH, 68307 Mannheim, has a certified quality assurance system that conforms to ISO 9001. ISO9001-3

Safety 1.4 Intended use 1.4.1 Marking The oil level sensor KVF-104-PF (referred to as "sensor" in the following section) is a suspended sensor for monitoring oil layer thickness in oil/petrol separators. The KVF-104-PF must always be connected to an ATEX-approved, intrinsically safe warning device of type LAL-SRW (see product program). The device is only approved for appropriate and intended use. Ignoring these instructions will void any warranty and absolve the manufacturer from any liability. Use the device only within the specified ambient temperature range. Individually accessible non-grounded metal parts can become electrostatically charged. The determined capacitance exceeds the required value according to IEC/ 60079-0. The determined capacitance is specified in the technical data. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Pepperl+Fuchs GmbH Lilienthalstrasse 200, 68307 Mannheim, Germany Oil level sensor KVF-104-PF DEMKO 07 ATEX 142586X II 1G Ex ia IIB T3 1.5 Delivery, Transport and Storage Check the packaging and contents for damage. Check if you have received every item and if the items received are the ones you ordered. Keep the original packaging. Always store and transport the device in the original packaging. Always store the device in a clean and dry environment. The permitted storage temperature (see data sheet) must be considered. 4 -

Safety 1.6 Installation and Commissioning 1.6.1 Installation des Sensors The sensor may be installed in potentially explosive zone 0 in accordance with Directive 94/9/EC (ATEX). The sensor must not be installed in places with potentially aggressive vapors. The sensor and warning device must be free of voltage during installation and maintenance. The warning device must only be connected to the supply voltage after complete mounting and connection of the sensors. The sensor has IP68 protection and is weather- and oil-resistant. It can therefore be installed in oil/petrol separators. When installing the device in oil/petrol separators, observe the permissible ambient temperature in the range from -20 C... 60 C (253 K... 333 K). 1.6.2 Installation in connection with intrinsically safe circuits Installation of the intrinsically safe power circuits of the devices is permitted in potentially explosive zones, whereby, in particular, safe separation from all nonintrinsically safe power circuits must be guaranteed. The intrinsically safe current circuits must be installed according to valid setup regulations. For the interconnection of the intrinsically safe field devices and the intrinsically safe power circuits of the associated devices, the respective maximum values of the field device and the associated device with regard to explosion protection must be observed (proof of intrinsic safety). 60079-14/IEC 60079-14 must be observed. If the used sensors have not a tested dielectric strength (500 V according to IEC/ 60079-11) between the external conductive parts and the intrinsically safe circuits, it must be assumed that the sensors and the corresponding intrinsically safe circuits have electrical contact with each other. In this case verification of intrinsic safety must include the possibility of the interconnection of all intrinsically safe circuits. 1.6.3 Sensor Cables Sensor cables must not be installed in cable or conductor bundles together with other current circuits. Avoid installing sensor cables parallel to other cables that may transmit interfering signals, which impair the sensor signal and thus the alarm function. The sensor itself must not be grounded. If you extend the sensor cable, observe the applicable ATEX specifications with regard to color, quality and durability. Use unshielded cables. - 5

Safety 1.7 Operation 1.7.1 Caution - emulsions An oil/petrol separator is a device for separating oil from water. Situations may arise in which the oil can not be separated because an emulsion has formed. An emulsion is a relatively stable mixture of oil and water. Sensors can not detect oil if emulsions with a high water content have formed. Always contact the oil/petrol separator manufacturer if there is any doubt as to whether the oil has been separated from the water before the liquid is drained to the sewage system. 1.8 Maintenance 1.9 Repair 1.10 Disposal For operation of oil/petrol separators, there may be standards, directives or laws that define regular system or sensor tests. Check the operation of the sensor at least twice a year and more frequently in the event of unfavorable environmental conditions. When the oil/petrol separator is being emptied (disposal), the sensor must always be washed and dried. The sensor must not be cleaned with caustic fluids. A badly contaminated sensor can trip a wrong alarm or, in certain circumstances, fail to trip an alarm. The devices must not be repaired, changed or manipulated. If there is a defect, the product must always be replaced with an original device. Disposal of devices and their packaging material must be performed in compliance with the applicable laws and guidelines of the corresponding country. The devices do not contain batteries which need to be disposed of separately from the products. 6 -

Product Specifications 2 Product Specifications 2.1 Function The sensor has an integrated electronic circuit which, via an oscillator circuit, emits a weak HF signal that changes depending on whether the sensor element is surrounded by water or by oil/air. The sensor is capable of distinguishing between air and water, and between water and oil, but not between air and oil. 2.2 Layout and dimensions The sensor consists of three sections (see illustration): The lower stainless steel section (1) provides electrical connection to the liquid. The middle section (2) is electrically isolated. The upper section made of stainless steel forms the switch contact (3). Ø31.6 3 4 5 138 25 2 1 Figure 2.1 1 Lower section with laser marking 2 Middle section 3 Upper section 4 Cable 5 Switching point - 7

Product Specifications 2.3 Product programm Warning device Description Intrinsically safe warning device, 230 V AC Type code LAL-SRW Sensors Description Overflow sensor for detecting excessively high fluid level Oil level sensor for detecting thickness of oil level Type code NVF-104/34-PF KVF-104-PF Accessories Description Cable connector IP68 for one sensor Mounting set for one sensor Type code LAL-SK2 NVO5-B 8 -

Installation 3 Installation 3.1 Mounting in oil/petrol separators Read the chapter on Safety and, in particular, the section on Installation and Commissioning (see chapter 1.6.1) before installing the sensor. Warning! Risk of short circuit Injuries and damage to the device are possible when working with live parts. Before working on the device, always disconnect the supply voltage. Connect the device to the supply voltage only after completion of the work. During installation, observe the instructions of the oil/petrol separator manufacturer. Always ensure that the sensor suspension device remains constantly at the correct height. If possible, ensure that the suspension device is mounted in a location that can be reached from the separator access shaft so that it is possible to raise the sensor during separator emptying (disposal) or maintenance of the oil/petrol separator. The oil/petrol separator can be made of various materials. We therefore recommend using the following methods to secure the device in a suspended position: If mounting the device in concrete containers, use the NVO5-B mounting set. See the figure below. If mounting the device in containers made from other materials, such as plastic or metal, use other suspension devices as appropriate, for example, screws and screw anchors. With a correct fluid level, the sensor must be immersed a few centimeters in the fluid. How far it is immersed depends on the type of oil/petrol separator, the design and the capacity. The lower section made of stainless steel must always be immersed in the fluid. The switch point (see chapter 2.2, dimension drawing, position 5) of the sensor is located between the isolated middle section and the upper metal section. - 9

Installation 6 4 1 5 3 2 1 Layer thickness 2 Alarm level 3 Sensor KVF-104-PF (new model) 4 Sensor KVF-103-PF (old model) 5 Water 6 Oil 3.2 Connection Read the chapter on Safety and, in particular, the section on Installation and Commissioning (see chapter 1.6.1) before connecting the sensor. Warning! Risk of short circuit Injuries and damage to the device are possible when working with live parts. Before working on the device, always disconnect the supply voltage. Connect the device to the supply voltage only after completion of the work. When making the connection, ensure the polarity of the sensor cables is correct. The loop resistance of the extension cable should not exceed 20 for the sensor. Note! Further information on connection of the sensors to the warning device is available in the manual of the warning device LAL-SRW. 10 -

Operation 4 Operation 4.1 Emptying/Disposing of the Container The sensor is a sensitive component. Please note the following information when disposing of/emptying the container: Caution! Malfunction or damage through mechanical stress of the sensor. In case of nonobservance, the safety and operation of the sensor or the entire alarm system is not guaranteed. Before emptying/disposal the oil/petrol separator, remove the sensor from the container. Protect the sensor against impacts, knocks and unnecessary tensile forces in the cable. Insert the sensor in the oil/petrol separator only after it has been filled. Caution! Malfunction or false alarm caused by a contaminated sensor If the sensor is very dirty, this may trigger a false alarm or mean that no alarm is triggered under certain circumstances. Clean and dry the sensor when emptying/disposing of the oil/petrol separator or container. Do not clean the sensor with corrosive liquids. - 11

Maintenance and Repair 5 Maintenance and Repair 5.1 Sensor test Test frequency The sensor is maintenance-free. However, to guarantee perfect operation of the complete alarm system check the operation of the sensor at least once a year, or more frequently in the event of unfavorable environmental conditions. Check of normal situation 1. Remove the sensor from the oil/petrol separator. 2. Wash and dry the sensor. 3. Take the sensor in your hand (without gloves). 4. Only touch the upper and lower metal section (see chapter 2.2, dimension drawing, position 1 and 3) The green "SYSTEM OK" LED lights up or flashes at the warning device. Check of alarm situation 1. Remove the sensor from the oil/petrol separator. 2. Wash and dry the sensor. 3. Suspend the sensor freely in midair. The "HIGH OIL LEVEL" LED lights up and, if applicable, an acoustic signal sounds. Note! Further information on the LED alarm messages is available in the manual of the warning device LAL-SRW. 12 -

Troubleshooting 6 Troubleshooting 6.1 Sensor Maintenance Caution! Malfunction or false alarm caused by a contaminated sensor If the sensor is very dirty, this may trigger a false alarm or mean that no alarm is triggered under certain circumstances. Clean and dry the sensor when emptying/disposing of the oil/petrol separator or container. Do not clean the sensor with corrosive liquids. Cleaning the Sensor The sensor is maintenance free. To ensure the entire alarm system functions correctly, clean the sensor at the following intervals: 1. Clean the sensor at least once a year. 2. Pay particular attention to cleaning the sensor tips of all oil, grease, and other dirt residues using a grease-dissolving cleaning agent. 3. If the sensor is used in difficult conditions, clean the sensor more often. - 13

Technical specifications 7 Technical specifications Power supply Rated voltage 13 V DC Directive conformity Electromagnetic compatibility Directive 2004/108/EC 61326-1:2013 (industrial locations), 55011:2009+A1:2010 Conformity Degree of protection IEC 60529:2001 Ambient conditions Ambient temperature -20... 60 C (-4... 140 F) Mechanical specifications Degree of protection IP68 Connection cable, length 5 m (15 ft), 2 x 0.75 mm 2 cross section Material stainless steel Mass approx. 580 g Dimensions 31.6 x 138 mm Data for application in connection with Ex-areas EC-Type Examination Certificate DEMKO 07 ATEX 142586X Group, category, type of protection, II 1G Ex ia IIB T3 temperature class Voltage U i 13 V Current I i 140 ma Power P i 1.05 W Internal capacitance C i 200 nf Internal inductance L i 0.2 mh Capacitance 50 pf for accessible non-grounded metal parts Directive conformity Directive 94/9/EC 60079-0:2012+A11:2013, 60079-11:2012 14 -

PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany 277659 DOCT-0937F 06/2015