Introductions. Safe for cultivation

Similar documents
ENVAIR lab CO2 Incubator

Heal Force Laboratory Equipment. CO2 Incubators. Heal Force leads you to healthier life

VWR symphony CO 2 INCUBATORS

ENVAIR lab CO2 Tri-Gas Incubator

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Benchtop CO 2 Incubator. the Oasis 6400 series

incubator, the best in its class

CO₂ incubators. C CB series

Technology, Quality, Reliability and Repeatability. ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. 1

CO₂ incubators. C CB series

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

EC 160 CO 2. Incubator

Professional CO2 and O2/CO2 Incubators

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

CO2 Incubators The Complete Line

intuitive, intelligent, interactive

Model C 170 CO 2 incubators with hot air sterilization

CO2 INCUBATOR CO2 INCUBATORS

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators

Reach-in CO 2 Incubators. 6024, 6026, 6044 & 6046 series

Cell Culture CO2 Incubators

Thermo Scientific Forma Steri-Cult CO2 Incubators High volume culturing and ultimate contamination control

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Controlled Environment Equipment Solutions for the Lab

CO2 INCUBATORS. The Safer Choice for Your Laboratory. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

Constant climate chambers

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Operation Manual. (Version 1.5.1)

Thermo Scientific CO 2 Incubators. Unmatched choice. Advanced technology. Proven results.

Refrigerated Incubators / Environmental Testing Chambers

Sterisonic GxP Series Cell Culture Incubators

Constant climate chambers

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

CO 2 Incubators Cradle for Beautiful Cells. CelCulture CO 2 Incubator Model CCL-170_-_

Drying and heating chambers

Protect your research

CO 2 Incubators: 7401, 7402 & 7403 Series

CO2 Incubators Cradle for Beautiful Cells. CelCulture CO2 Incubator

FILE No. Service Manual. CO2 Incubator MCO-18AIC SM

CelCulture CO2 Incubators CelCulture for IVF. Cradle for Beautiful Cells. Cradle for Optimal Embryo Incubation. Designed in the USA

Designed to achieve your next breakthrough. Thermo Scientific Heracell VIOS CO 2. Incubators

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

CelCulture. Cradle for Beautiful Cells. Designed in the USA. CelCulture CO 2 Incubators

Heated and Refrigerated Incubators

Operating Manual Culture Safe Precision CO2 Incubator P50

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

BINDER Product catalog

laboratory & sterilization technology

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

CelCulture CO2 Incubators CelCulture for IVF. Cradle for Beautiful Cells. Cradle for Optimal Embryo Incubation. Designed in the USA

Operation Manual (Version 1.5.1)

Infrared Moisture Balance (FD-800)

Constant climate chambers

Laboratory & Pharmacy Refrigerators

Future Blast Chiller and Blast Chiller/Freezer cabinets

CO 2 Incubators INCO 2

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Constant climate chambers

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

LABTRON LHI - Series Heating INCUBATOR

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

Thermo Scientific 1300 Series A2

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

INCREASE YOUR LAB EFFICIENCY

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Plant Growth Chamber MPGR14

Laboratory & Process Equipment

A look into our complete product collection. powered by

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Models: 370/371 and 380/381

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

FagronLab NP-1 UV. Negative pressure workbench. User Manual

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Operation Manual. VWR Vacuum Ovens. (Version 2.0.0) VWR Vacuum Oven , , , ,

Freezers. Laboratory & Plasma. i.series Horizon Series

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

FITOCLIMA 600 & 1200 STABILITY

Incubators. with BioCote antimicrobial protection

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

FITOCLIMA 600 & 1200 PHARMA

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

STABILITY ICH. ICH Stability Tests

Platelet Storage. i.series Horizon Series

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

Constant climate chambers

FITOCLIMA 600 & 1200 STABILITY

Double Skin Air Handling Units

Transcription:

ES cell research In vitro fertilization cell test Introductions CO2 incubators are widely used in scientific research to grow and maintain cell cultures. A Heal Force CO2 incubator provides you with unsurpassed natural simulation to ensure optimum growth conditions for your culture at all time. That's why they become the first choice of researchers in fields of application include tissue engineering, in vitro fertilization, neuroscience, ce, cancer research and other mammalian cell research. Gene research Safe for cultivation Cancer research Cell cultivation in particular is a highly sensitive process in which bacteria, viruses, fungal spores and mycoplasmas can destroy valuable cultures or distort test results, causing more work. Heal Force solves this problem using a unique design and effective method to ensure sterile conditions. 90 60 30 90 moist heat disinfection pattern 90 moist heat disinfection (HF90 & HF240) HF90 and HF240 are equipped with 90 moist heat disinfection system. The validated overnight sterilization cycle ensures reliable destruction of germs that could interfere with your work and requires no extra work, such as removal of interior fittings. Mycoplasma is 100% eliminated in a routine disinfection cycle. Ultraviolet disinfection (HF151UV & HF212UV) A long-life ultraviolet lamp is equipped at the inner back of HF151UV and HF212UV to sterilize chamber air and water in the reservoir to maintain contamination-free conditions within the chamber. To take maximum effect of disinfection, the wavelength of UV light is kept at 254nm. UV lamp Coved corners Easy-to-clean design The cleaning process is significantly simplified by Heal Force's unique, seamless, deep-drawn interior chamber, which reduces any areas where contamination could accumulate. Heal Force incubators offer the best usable-space-to-volume ratio due to the total absence of any additional fittings in the interior chamber Inlet filter for CO2 supply All gas injection lines are filtered via HEPA filter to remove impurities and contaminants before being injected into the chamber. The HEPA filter is able to filter particles larger than 0.3μm at 99.998%. CO2 inlet filter

Absolutely condensation-free, even at high air humidity level The high air humidity prevents cell cultures from drying out and also keeps the osmolarity constant in the culture medium. With our CO2 incubators, you can work with air humidity up to 95% while the interal walls remain completely dry ( In order to prevent contamination, however, no condensation must occur). The patented tilted water reservoir system keeps the air humidity absolutely stable. Water reservior Optimum temperature control A reliable air jacketed heating system combined with temperature sensors ensures high precision with homogenous heat distribution in the interior. Outstanding dynamics ensure short recovery times and balance out any fluctuations caused by door open for Heal Force CO2 incubators. This provide reliable protection at any time, particularly for sensitive cultures. The main heater provides precise temperature control. The bottom heater warms the distilled water and ensures chamber humidity. The outer door heater prevents condensation on the inner door and facilitates quick temperature recovery after door openings. Divided, inner glass door Three inner glass doors (HF90) maintains stable climatic conditions, minimizes any changes to the humidity, heat and gas concentration, shortens recovery times significantly and also further reduces the risk of contamination. Six half-size sealed inner glass doors and shelves are optional for model HF240. This makes it possible for several users to work with the same equipment HF90 with 3 inner glass doors (standard) HF240 with 6 half-size inner glass doors and shelves (optional) Auto-start function The auto-start function, which considerably simplifies the equipment's operation, contains the incubator's automatic start-up and the measuring system's calibration. The thermal conductivity CO2 sensor has its baseline automatically reset without manual adjustment. The incubator can be loaded immediately after the start-up routine is completed. Auto-start function

Specifications Model Construction Exterior dimensions (W D H) Interior dimensions (W D H) Interior Volume Net Weight Interior Exterior Inner door Temperature Heating method Temp. control system Temp. sensor Temp. range Temp. uniformity Temp. stability CO2 Inlet pressure CO2 control system CO2 sensor CO2 range CO2 stability Humidity Humidifying system Relative humidity Water reservior volume Shelves Shelf dimensions (W D) Shelf construction, Maximum Fittings Access port Air filter Remote alarm contacts De-contamination Rated power Power supply Alarm system Data output HF90 637 762 909(mm) 25.1 30.0 35.8(inch) 470 530 607(mm) 18.5 20.8 23.9(inch) 151L/5.3cu.ft. 80kg/176lbs. 3 inner doors standard ±0.2 3L 423 445(mm) 16.7 17.5(inch) 3,10 HF240 780 820 944(mm) 30.7 32.3 37.2(inch) 607 583 670(mm) 23.9 22.9 26.4(inch) 240L/8.5cu.ft. 80kg/176lbs. 6 mini inner doors optional 5 above ambient temperature to 50 ±0.2 3L 423 445(mm) 16.7 17.5(inch) 3,12 90 moist heat disinfection 90 moist heat disinfection 600W 735W 220V/50Hz (standard), 220V/50Hz (standard), 110V/60Hz (Optional) 110V/60Hz (Optional) HF151UV 615 768 865mm) 24.2 30.2 34.1(inch) 470 530 607(mm) 18.5 20.9 23.9(inch) 151L/5.3cu.ft. 75kg/165lbs. Type 304, mirror finish, stainless steel Electrolyzed galvanization steel, powder coated Direct Heat & Air Jacket (DHA) one inner door standard ±0.2 Special designed water reservoir 4L 423 445(mm) 16.7 17.5(inch) 3,10 Type 304, mirror finish, stainless steel Optional 0.3μm, Efficiency:99.998% (for CO2) UV lamp 600W 220V/50Hz (standard), 110V/60Hz (Optional) HF212UV "910 763 795(mm) 35.8 30.0 34.1(inch)" "600 588 600(mm) 23.6 23.1 23.6(inch)" 212L/7.5cu.ft. 95kg/209lbs one inner door standard ±0.3 6L 590 510(mm) 23.2 20.1(inch) 3,12 Optional UV lamp 700W 220V/50Hz (standard), 110V/60Hz (Optional) Power interruption * High/low temperature * Deviation of CO2 * RH * Door ajar * Independent overheat protection HF90 HF240 HF212UV HF151UV

Water-jacketed The large size Heal Force HF160W CO2 incubator incorporates a water jecketed system. Because of the heat retention characteristics of water, there is no sudden temperature change in the event of an unexpected power failure. A stable temperature enviroment is ensured. HEPA filter HF160W applies long term effectiveness of the HEPA filter to protect your cultures. The filter is very efficient to entrap particulates larger than 0.3μm at 99.97%. The HEPA filter system runs continuously and within every 60 seconds, the volume of entire chamber is disinfected. With help of HEPA filter, the air quality achieves Class 100 clean room levels within 5 minutes following a door opening. HEPA filter Airflow system Optimized air flow system ensures the temperature and CO2 concentration to be stable and uniform within the chamber. HEPA filter and air flow pattern AUTO-ZERO/AUTO-START HF160W combines precise CO2 control with a choice of TC or IR sensors. The microprocessor will automatically "Zero" the incubator(ir type) using room air as a reference every 24 hours. Auto-start function for TC type ensures the sensor's beseline automatically reset without manual adjustment. These features will maintain an accurate CO2 control without worrying about CO2 drift. Automatic control door heater The outer door incorporates a door heater which is interlocked with the surrounding temperature monitoring system. This prevents temperature differences between the chamber and the inner door, thereby preventing condensation. Humidity display and alarming system HF160W is able to create a high humidity environment and the relative humidity (RH) is displayed on the panel, readable in 0.1% increments, including low RH programmable alarm(alerts you of need to add water) Space Utility Stackable design takes up less space. Two or three units can be stacked according to available space and usage

Automatic gas cylinder switchover system This system automatically switches from the primary to secondary gas cylinder when CO2 gas level does not change while an injection valve is open. A. power switch B. camber gas sample port C. fill port D. CO2 sensor E. temperature sensor F. humidity sensor G. piling leg H. mirror finish shelves I. water jacket J. glass fibre insulator K. high efficiency HEPA L. magnetic gasket M. outer door heater N. water pan O. water jacket drain P. coved corner HF160W Specifications Construction Exterior dimensions (W D H) Interior dimensions (W D H) Interior Volume Water jacket volume Net Weight Interior Exterior Inner door Temperature Heating method Temp. control system Temp. sensor Temp. range Temp. uniformity Temp. stability CO2 Inlet pressure CO2 control system CO2 sensor CO2 range CO2 stability 655 656 1030(mm) 25.8 25.8 40.5(inch) 544 504 681(mm) 21.4 19.8 26.8(inch) 185L/6.5cu.ft. 43.5L/1.54cu.ft. 110kg/242lbs Type 304, mirror finish stainless steel cold-rolled steel, power coated one inner door standard Water Jacket 5 above ambient temperature to 55 ±0.2 ±0.1 /Infrared Humidity Humidifying system Humidifying sensor Relative humidity Display Water reservior volume Shelves Shelf dimensions (W D) Shelf construction, Maximum Fittings Access port Air filter Remote alarm contacts De-contamination Rated power Power supply Alarm system Data output Humidity pan In 0.1% increments 3L "466 440(mm)18.3 17.3(inch) Type 304, mirror finish, stainless steel 3,11 0.3μm Efficiency:99.998% (for CO2) HEPA filter system 430W 220V/50Hz (standard), 110V/60Hz (Optional) Power interruption * High/low temperature * Deviation of CO2 * RH * Door ajar * Independent overheat protection 12 CO2 Incubator 7