Capri B Cast iron combination oil-fired boiler with water tank

Similar documents
Capri R CH only, oil-fired, cast iron boiler

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

C Tahiti. condensing

Condensing, pre-mixed, wall-hung gas boilers with water tank

MINORCA KC - KR - KRB 24

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

HORIZONTAL HOT WATER CYLINDER WHPF BO

FORMENTERA KC - KRB - KR

1 VICTRIX ZEUS Superior kw I features

Light oil - kerosene burner

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

ACCUMULATION OF EUROPEAN CLASS

ANTEA KC - KR - KRB

SPECIFICATIONS - NIKE

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Light oil burners. One stage operation

Light oil / kerosene burner

Ideasandformsinevolution

VICTRIX Superior kw Export VICTRIX Superior kw X Export

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Floor standing boilers. RMG Mk.II RS Mk.II

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

STILE BEAUTY AND TECHNOLOGY

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

The mechatronics of EVE 05

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Oil burners Brûleurs fioul Stookoliebranders

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Easyfire Standalone biomass pellet boiler

INSTALLATION AND OPERATION MANUAL

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

S SOLAR RANGE

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

WHE 2.24 / WHE 2.24 FF

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Burner Comparisons. Typical Competitor s Burner

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

CRIMSON & CRIMSON MAX

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

Flue gas condensation...

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

CAST IRON ATMOSPHERIC BOILERS

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

TAHITI CONDENSING KR 55 - KR 85

International Markets. Product Catalogue. complementary items

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

Design Manual. Pre-assembled unit (LINK) Heating and Cooling/Heating modular groups. Platform PRO

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

Ciao Green Condensing Wall-Hung Boilers

Parts Available from

8FUEL OIL CONDENSING BOILERS

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

4FLOOR-STANDING GAS CONDENSING BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

Mynute Green Condensing Wall-Hung Boilers

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TWO STAGE HEAVY OIL BURNERS

MPO IQ 87% AFUE. Limited Lifetime Warranty! control. Oil-Fired, High Efficiency, 3-Pass Water Boiler. system GREATER ENERGY SAVINGS

thea 35 MR/MN Kondens Wall-mounted condensing boiler

OPX INDUSTRIAL RANGE THERMAL OIL

Prextherm Rsw High efficiency steel pressurised boilers

DOMESTIC HOT WATER Follow operational sequence

Heating Equipment. gas boilers RX GB. installation and servicing instructions

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Wall-hung boilers. Spare parts catalogue. ecotec plus

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

ENERGY TOP. Condensing boiler solutions

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

A/23 MFFI - A/27 MFFI

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

en Direct oil-fired space heaters HD... Operator's manual

Forced draught gas burner

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

The guarantee on this appliance is valid for 12 months from the first day of installation.

Transcription:

C 151-01 Cast iron combination oil-fired boiler with water tank Life-enhancing heat GB

Cast iron combination oil-fired boiler with water tank RELIABILITY SAFETY EASY OPERATION EASE OF MAINTENANCE

Life-enhancing heat is the new oil-fired, combination, floor-standing, system boiler (central heating + production of domestic hot water and water tank), entirely designed and manufactured by Fondital. The range includes 12 models, with heat outputs from 24 to 43 kw, available with open chamber (BTF) and sealed chamber (BTFD), both can be supplied with double flow connection for systems with low and high temperature zone (versions V: BTFV, BTFDV). The heat exchanger is made of cast iron (EN-GJL-200) with three smoke passes, the design of the combustion chamber allows the flame to fully develop and to spread on an ample surface of exchange, thus absorbing superior quantities of heat while allocating a low thermal load on walls. A high-thickness insulation completely covers the boiler body, avoiding wasteful and detrimental heat dispersions toward the outside. The casing is made of electro-galvanic finished sheet panels, painted with epoxy-polyester powders for the longest lifetime. The domestic hot water supply is obtained by means of a 130-lt., glass enameled water tank, equipped with high efficiency coil exchanger, magnesium anode and insulated with a thick layer of expanded polyurethane. The water tank interior can be inspected. The efficiency rating for all models, according to 92/42/ EC, is two stars. V models only The control panel includes a printed circuit board and master switch with light, operating mode selector, domestic hot water and central heating temperature adjusting selectors, water pressure gauge, led thermometer which acts as diagnostic indicator as well, overheating reset button. The control panel can also host a digital, two channel programmer, managing heating unit, which is supplied as standard with V models, or an electromechanical programmer optionally supplied for all other models. The heating unit can be connected to a thermostat and it can also operate in sliding temperature mode by connecting an external probe, supplied upon request (code: 0SONDAES01). A remote control can be connected to the heating unit (optional equipment), which together with an external probe (code: 0KSONEST00) allows for improved management of the heating unit. In order to manage a multiple zone central heating system, a suitable kit is available as an accessory which is capable of managing three heating zones and, when coupled by an external probe (standard with the kit) allows for sliding temperature operation mode; the probe is to be connected to the printed circuit board of the heating unit. The remote control is also designed for three central heating zone system management. The available combinations of different zone management printed circuit board, remote control and external probe are listed below. MODEL ZONE MANAGEMENT PCB REMOTE CONTROL EXTERNAL PROBE NOTES CAPRI B NO NO 0SONDAES01 To be connected to the heating unit printed circuit board. CAPRI B NO YES 0KSONEST00 To be connected to the remote control CAPRI B YES NO 0SONDAES01 To be connected to the heating unit printed circuit board. CAPRI B YES YES 0SONDAES01 To be connected to the heating unit printed circuit board. CAPRI BV YES* NO 0SONDAES01* To be connected to the heating unit printed circuit board. CAPRI BV YES* YES 0SONDAES01* To be connected to the heating unit printed circuit board. * supplied as standard

Cast iron combination oil-fired boiler with water tank DIMENSIONS 600 796 TFD VERSION 107 80 256 M1 D M2 40 R1 R2 1586-1596 1507 M 144 R C S 455 83 652 891 1356 F Model M R M1 R1 M2 R2 C F S D FLUE GAS DISCHARGE mm COMBUSTION AIR INTAKE mm BTF/BTFV 23 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/2 150 -- BTF/BTFV 33 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/2 150 -- BTF/BTFV 43 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/2 150 -- BTFD/BTFDV 23 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/2 120 80 M CH flow C DHW flow F Domestic cold water inlet R CH return S Re-circulation M1 High temperature CH flow (V version) R1 High temperature CH return (V version) M2 Low temperature CH flow (V version) R2 Low temperature CH return (V version) BTFD/BTDV 31 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/2 120 80 BTFD/BTDV 43 G 1 G 1 G 1 G 1 G 1 G 1 G 3/4 G 3/4 G 1/2 120 80 ACCESSORIES Item Description Code Remote control 0CREMOTO02 External probe for remote control 0KSONEST00 External probe for use without remote control 0SONDAES01 Electric kit managing 3 central heating zones via remote control. Equipped with external probe. 0CIRCSTA11 Daily timer kit 0KITBEST04 Weekly timer kit 0KITBEST05

Life-enhancing heat HYDRAULIC LAYOUTS: B MODEL Domestic cold water PR: CH PUMP PS: DHW PUMP TS: LIMIT THERMOSTAT TA1: ZONE 1 ROOM THERMOSTAT (OPTION) S1: CH PROBE EXTERNAL PROBE WATER TANK WATER TANK PROBE TS S1 PS TS Domestic hot water HEAT EXCHANGER PR TA 1 Or ZONE 1 HIGH TEMPERATURE REMOTE CONTROL BV MODEL Domestic cold water PR: CH PUMP PS: DHW PUMP P1: HIGH TEMPERATURE CH PUMP P2: LOW TEMPERATURE CH PUMP TS: LIMIT THERMOSTAT TSM: LOW TEMPERATURE LIMIT THERMOSTAT VM: MIXING VALVE TA1: ZONE 1 ROOM THERMOSTAT (OPTION) TA2: ZONE 2 ROOM THERMOSTAT (OPTION) TS EXTERNAL PROBE S1 HEAT EXCHANGER PS PR WATER TANK COLLECTOR WATER TANK PROBE P1 M VM P2 TSM Domestic hot water ZONE 1 HIGH TEMPERATURE TA 1 LOW TEMPERATURE CH FLOW PROBE ZONE 2 LOW TEMPERATURE TA 2 Or REMOTE CONTROL

Cast iron combination oil-fired boiler with water tank The manufacturer reserves the right to implement modifications without notice. MODEL TECHNICAL DATA BTF / BTFD / BTFV / BTFDV 23 33 43 Efficiency rating Heat input Qn kw 26.6 36.3 47.2 Heat output Pn kw 24 33 43 Efficiency at nominal load % 90 90.9 91 Efficiency at reduced load (30%) % 89.7 90.7 90.7 Flue gas heat loss % 8.75 8.1 8.1 Casing heat loss % 1.25 1 0.9 No. of elements of heat exchanger 3 4 5 CO 2 value % 12.5 13.0 12.5 13.0 12.5 13.0 Flue gas temperature C 210 190 188 Bacharach number <1 <1 <1 Flue gas flow rate Kg/h 40.0 53.2 69.3 Load loss flue gas side Pa 13 25 34 Combustion air flow rate m 3 /kw 2 2 2 Water content l 20 24 28 CH minimum flow rate l/h 680 950 1230 Load loss water side ( T=10K) Pa 4800 5600 6000 Temperature holding heat loss ( T=50K) % 0.5 0.5 0.5 CH water temperature adjustment C 50 82 50 82 50 82 Maximum CH working pressure bar 3 3 3 CH expansion vessel capacity l 12 12 12 DHW expansion vessel capacity l 5 5 5 DHW temperature adjustment C 35 57 35 57 35 57 Maximum DHW working pressure bar 7 7 7 DHW supply ( T=30K) l/10 min 215 250 265 Voltage/Frequency V/Hz 230/50 230/50 230/50 Power fuse A 2 2 2 Height mm 1600 1600 1600 Width mm 600 600 600 Depth mm 800 800 800 BURNER TECHNICAL DATA MODEL 23 33 43 Fuel Oil 1.4 E. Hi=10210 Kcal/kg 20 C Nozzle brand Delavan W, Steinen Q, Danfoss S Nozzle type Usgal/h 0.56 0.85 1 Nozzle angle 60 W 60 W 60 B Oil pressure pre-adjustment bar 11.4 12 12 Oil consumption Kg/h 2.24 ± 4% 3.06 ± 4% 3.98 ± 4% Pump depression bar > -0.4 > -0.4 > -0.4 Pre-heater W 55 55 - Fuel head pre-adjustment fix fix fix Uff. Pub. Fondital - CTC 03 C 151-01 Giugno 2006 (2.000-06/2006) 9PCGB03C151 FONDITAL S.p.A. 25078 VESTONE (Brescia) Italy - Via Mocenigo, 123 Tel. +39 0365 878.31 - Fax +39 0365 820.200 e mail: info@fondital.it - www.fondital.it