PTG, SWT Series. Heat Recovery Systems

Similar documents
CRA24-B3 controlled residential ventilation

Rotary Screw Compressors SXC»Compact«Series

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Rotary Blowers COMPACT Series With the world-renowned OMEGA PROFILE Air delivery 0.5 to 93 m 3 /min Pressure up to 1000 mbar, Vacuum to 500 mbar

Rotary Screw Compressors SXC»Compact«Series. With the world-renowned SIGMA PROFILE FAD 0.26 to 0.8 m 3 /min, Pressures bar

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Installation Instructions

Heat Recovery Systems PTG, SWT Series.

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

The advantages of closed heating systems. White paper

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Beckhoff short profile

International standards used locally worldwide ISO/TC 67

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Future development of the furniture industry A look at the next 3-5 years

Heat recovery systems. For hot air and hot water applications.

Advantages of automatic boiler bottom blowdown

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

Heat recovery. Heat recovery. Gas heating 280 up to 54,000 /year. Oil heating 284 up to 54,761 /year. Electrical power consumption

Accuracy counts! Sensors with analog output

COMPRESSORS. Heat recovery. For hot air and hot water applications.

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

AutoM Click to go to the page. AutoM Auto Shaker Filter

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Textile fire protection closures EI 30/90

Value engineering developed from global experience

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Expansion vessel in a solar installation. White paper

Fire-Resistant. Automatic Doors

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

STANDARD T6 (200 C) SENSOR CABLE RANGE

L-force Drive-based Safety. Safe, scaleable and above all integrated

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Air and dirt in closed systems


Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

30th. English. Anniversary Since 1980 RICH. Heat & Cool molding system RICH-2. ZICUL (Chiller) WATER PURIFIER

EU directives WEEE and RoHS. Information and notes

Labeling and Identification Products

Signal converters SVE4 Product overview

Contents. +0 % VS 2016 On page 1 you will find the key indicators at a glance : chains in the country: 2016 and 2017 sales, number of stores,,

Pressing for Excellence. Tunnel Finisher & Bagging Machines

SBA Profile. Privacy Statement (Back to Profile List, or use Back button) Identification, Location & Contacts

Foreword. A completely revised report for quicker and easier access to key information

This document is a preview generated by EVS

stylemakerstm SINCE 1895

Rotary blowers COMPRESSORS. Flow capacities from 1.5 to 160 m³/min Gauge pressure up to 1000 mbar, vacuum down to 500 mbar.

This document is a preview generated by EVS

Brazed plate heat exchangers. By GEA PHE Systems Engineered by Kapp

31 countries 1 internal market of safe products. Rapid Alert System for dangerous products 2015 RESULTS. Justice and Consumers

The national standards bodies of:

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

MJC Click to go to the page. MJC Cartridge Filter

MKN Galley Solutions

KNX The worldwide STANDARD for home and building control. KNX Association International

Product Warranty and Installation Bulletin for LC5511 Calendered Window Decoration Film

KNX The worldwide STANDARD for home and building control. KNX Association International

English version. Alarm systems Terms and definitions

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

FEBRUARY 2019

Hello. We d like to introduce you to our family

PVC & PET FILMS FOR TOMORROW, TODAY.

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

Bathroom September 2010

Welcome and breaking the ice!

Log fired heating system

This document is a preview generated by EVS

This document is a preview generated by EVS

Nationwide Footprint International Reach

This document is a preview generated by EVS

Pillow Plate Heat Exchanger SYNOTHERM

Pillow Plate Heat Exchanger SYNOTHERM

Sýnishorn Windows and doors - Watertightness - Test method

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Founding - Magnetic particle testing

This document is a preview generated by EVS

International Product Compliance and Certifications. Product Safety Consulting, Inc.

SOUTH AFRICAN NATIONAL STANDARD

The best choice in hot air tools

WORLDWIDE DISTRIBUTORS

StolenVehicle Tracking

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

This document is a preview generated by EVS

English Version. Office furniture - Office work chair - Part 4: Clarifications to EN :2000 (Dimensions)

Sýnishorn Chemical disinfectants and antiseptics - Application of European standards for chemical disinfectants and antiseptics

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Telematics Services. Vodafone Power to you. Vehicle Security and Remote Management in the palm of your hand. automotive.vodafone.

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

Sýnishorn Maintenance - Qualification of maintenance personnel

CHIMNEY SYSTEMS PRODUCT OVERVIEW. LAUNDRY CHUTES.

FEBRUARY 2019

TECHNICAL PUBLICATION. Frequent deficiencies per port. Guidelines

This document is a preview generated by EVS

STANDARDISATION OF SRF (ISO/TC 300)

E-T-A Get Smart With Your Systems

CEN/TC 256 Overview. Presentation to ISCC January C Cork Chair CEN/TC CEN all rights reserved

Heating with pellets kw

This document is a preview generated by EVS

Transcription:

PTG, SWT Series Heat Recovery Systems

Hot air exhaust in summer Shutter Ducting system Available hot air Fresh air inlet Compressor Because of the enclosed, compact construction of screw compressors, it is no problem to recover 94% of their overall energy consumption from the cooling air with a ducting system and guide it to where it is needed. Using this method, the compressor room and adjacent facilities, such as warehouses, workshops, etc. can be heated, either fully or partly. In summer, when no heating is required, the exhaust heat can be directed to the open air by swivelling a shutter in the ducting. The movement of the shutter and thus the flow of hot air into the adjacent facilities can be precisely determined by thermostatic control, allowing a constant temperature to be maintained in these spaces. Applications Auxiliary or main heating for warehouses, workshops, etc. Drying aid for paint spraying, or washing Air curtains Improving efficiency of oil burners by heating the combustion air Keeping large spaces at moderate temperatures Space Heating System Rated Maximum available Useable Cooling Savings potential Rotary screw motor thermal power hot air air heating over 2000 hours compressor power volume Heating Heating oil costs Model kw kw MJ/h m 3 /h K(approx.) l 3 SX 3 2.2 2.5 9 1100 7 724 181 SX 4 3 3.5 13 1500 7 1014 254 SX 6 4 4.6 17 1500 9 1333 333 SM 8 5.5 6.2 22 1500 12 1796 449 SM 11 7.5 8.4 30 1500 17 2434 608 SK 19 11 12.4 45 2500 15 3593 898 SK 26 15 16.8 60 2500 20 4868 1217 ASD 32 18.5 21.5 77 3800 17 6229 1557 ASD 37 22 25.4 91 3800 20 7359 1840 ASD 47 25 31.1 112 4500 21 9011 2253 ASD 57 30 35.9 129 5400 20 10402 2600 BSD 62 30 35.5 128 5700 19 10286 2571 BSD 72 37 43.2 156 5700 23 12517 3129 CSD 82 45 53 191 8000 20 15356 3839 CSD 102 55 64 230 8000 24 18543 4636 CSD 122 75 79 284 9000 26 22889 5722 CSDX 137 75 94 338 13000 22 27235 6809 CSDX 162 90 106 382 13000 24 30712 7678 DSD 141 75 82 295 9000 27 23759 5940 DSD 171 90 98 353 14000 21 28394 7099 DSD 201 110 118 425 16000 22 34189 8547 DSD 241 132 142 511 21000 20 41143 10286 DSD 281 160 171 616 21000 24 49545 12386 ESD 251 132 137 493 21000 20 39694 9924 ESD 301 160 187 673 28000 20 54181 13545 ESD 351 200 227 817 28000 24 65771 16443 ESD 361 200 210 756 27000 23 60845 15211 ESD 441 250 244 878 34000 22 70696 17674 FS 440 250 269 968 40000 20 77940 19485 GS 580/590 315 30 107 10000 9 8605 2151 GS 640/650 355 34 121 10000 10 9706 2427 HS 690 400 38 136 12000 9 10923 2731 HS 760 450 42 153 12000 11 12285 3071 Heat value of heating oil: 35.5 MJ/l = 9.861 kwh/l 1 kw =1 MJ/h x 3.6 Heating efficiency: 0.7 Price of heating oil: 3 0.25 / l Calculation for an ASD 32: (usable heat energy: 21.5 kw Cost savings = 21.5 kw x 2000 h x 3 0.25 / l = 3 1557 0.7 x 9.861 kwh/l

Shower Compressor Plate-type heat exchanger Hot water storage tank PTG Water Heating System The PTG heat exchanger consists of a stack of up to 200 individually stamped stainless steel plates, brazed in a vacuum furnace using 99.9 percent pure copper. The plate profile generates a highly turbulent flow within the channels to ensure efficient heat transfer. Every alternate plate is fitted at 180 degrees to the next, providing innumerable contact points right across the heat exchanging surface. Because of the high temperatures possible (around 80 C) the system is enclosed in a frame to prevent injury through contact. The plate-type heat exchanger can produce hot water at about. 70 C. If less, or even no hot water is needed, the compressor cooling fluid flow is automatically directed through the standard fluid cooler. Cooling of the compressor is constantly assured whether hot water is required or not. The system can be easily integrated in any hot water supply plant, especially where it is desirable to avoid mixing water and cooling fluid. Applications laundries, showers, bathrooms and washrooms canteens and large kitchens food industry chemical and pharmaceutical industries industrial cleaning processes plating processes Rotary screw Rated Maximum available Hot water volume Installacompressor Savings potential motor thermal power Heating to Heating to tion over 2000 hours power 70 C 70 C Heating Heating ( T 25 C) ( T 55 C) oil costs Model kw kw MJ/h m 3 /h m 3 /h int./ ext. l 3 ASD 32 18.5 16.4 59 0.55 0.25 intern 4752 1188 ASD 37 22 19.3 69 0.67 0.31 intern 5592 1398 ASD 47 25 23.9 86 0.83 0.38 intern 6925 1731 ASD 57 30 27.6 99 1.03 0.43 intern 7997 1999 BSD 62 30 27.0 97 0.92 0.42 intern 7823 1956 BSD 72 37 33.3 120 1.14 0.52 intern 9648 2412 CSD 82 45 40.8 147 1.39 0.63 intern 11821 2955 CSD 102 55 49.4 178 1.70 0.77 intern 14313 3578 CSD 122 75 62 223 2.00 0.91 intern 17964 4491 CSDX 137 75 73 263 2.56 1.15 intern 21151 5288 CSDX 162 90 84 302 2.93 1.32 intern 24338 6085 DSD 141 75 65 234 2.20 1.00 intern 18833 4708 DSD 171 90 78 281 2.60 1.20 intern 22600 5650 DSD 201 110 93 335 3.20 1.46 intern 26946 6736 DSD 241 132 114 410 4.30 1.78 intern 33030 8258 DSD 281 160 138 497 4.46 2.02 int.ext. 39984 9996 ESD 251 132 110 396 3.81 1.73 extern 31871 7968 ESD 301 160 146 526 4.69 2.22 extern 42302 10575 ESD 351 200 180 648 5.77 2.62 extern 52153 13038 ESD 361 200 169 608 5.83 2.65 extern 48966 12241 ESD 441 250 197 709 6.70 3.05 extern 57078 14270 FS 440 250 209 752 7.20 3.27 extern 60555 15139 GS 580/590 315 263 947 9.08 4.12 extern 76201 19050 GS 640/650 355 296 1066 10.23 4.65 extern 85763 21441 HS 690 400 334 1202 11.52 5.23 extern 96773 24193 HS 760 450 376 1354 12.97 5.89 extern 108942 27235 Heat value of heating oil: 35.5 MJ/l = 9.861 kwh/l 1 kw =1 MJ/h x 3.6 Heating efficiency: 0.7 Price of heating oil: 3 0.25 / l Calculation for an ASD 32: (usable heat energy: 16.4 kw Cost savings = 16.4 kw x 2000 h x 3 0.25 / l = 3 1188 0.7 x 9.861 kwh/l

Pressure monitor Heat transfer medium Expansion tank Water out Water in Compressor cooling fluid out Compressor cooling fluid in SWT Water Heating System In the SWT fail-safe heat exchanger one tube is fitted into another such that a space still exists between the two tubes. Both tubes are individually pressed into separate tube end plates. The space is filled with a harmless heat transfer medium kept at a constant pressure by the expansion tank. This pressure is continuously monitored by a pressure switch. In case of breakage or corrosion. either water or compressor cooling fluid mixes with the heat transfer medium and the pressure increases, actuating the pressure switch, giving an alarm or shutting down the compressor. The fail-safe heat exchanger is piped exactly the same as the plate-type heat exchanger and can produce hot water at about. 70 C. If less, or even no hot water is needed, the cooling fluid flow is automatically directed through the standard cooler of the compressor. Cooling of the compressor is constantly assured whether hot water is required or not. The SWT system is particularly suitable forproviding hot water of drinking quality where it is essential that there is no danger of the water being contaminated by cooling fluid. Applications Food industry Hot drinking water Chemical and pharmaceutical industries Canteens and large kitchens Rotary screw Rated Maximum available Hot water volume Installacompressor Savings potential motor thermal power Heating to Heating to tion over 2000 hours power 70 C 70 C Heating Heating ( T 25 C) ( T 55 C) oil costs Model kw kw MJ/h m 3 /h m 3 /h extern l 3 ASD 32 18.5 16.4 59 0.55 0.25 extern 4752 1188 ASD 37 22 19.3 69 0.67 0.31 extern 5592 1398 ASD 47 25 23.9 86 0.83 0.38 extern 6925 1731 ASD 57 30 27.6 99 1.03 0.43 extern 7997 1999 BSD 62 30 27.0 97 0.92 0.42 extern 7823 1956 BSD 72 37 33.3 120 1.14 0.52 extern 9648 2412 CSD 82 45 40.8 147 1.39 0.63 extern 11821 2955 CSD 102 55 49.4 178 1.70 0.77 extern 14313 3578 CSD 122 75 62 223 2.00 0.91 extern 17964 4491 CSDX 137 75 73 263 2.56 1.15 extern 21151 5288 CSDX 162 90 84 302 2.93 1.32 extern 24338 6085 DSD 141 75 65 234 2.20 1.00 extern 18833 4708 DSD 171 90 78 281 2.60 1.20 extern 22600 5650 DSD 201 110 93 335 3.20 1.46 extern 26946 6736 DSD 241 132 114 410 4.30 1.78 extern 33030 8258 DSD 281 160 138 497 4.46 2.02 extern 39984 9996 ESD 251 132 110 396 3.81 1.73 extern 31871 7968 ESD 301 160 146 526 4.69 2.22 extern 42302 10575 ESD 351 200 180 648 5.77 2.62 extern 52153 13038 ESD 361 200 169 608 5.83 2.65 extern 48966 12241 ESD 441 250 197 709 6.70 3.05 extern 57078 14270 FS 440 250 209 752 7.20 3.27 extern 60555 15139 GS 580/590 315 263 947 9.08 4.12 extern 76201 19050 GS 640/650 355 296 1066 10.23 4.65 extern 85763 21441 HS 690 400 334 1202 11.52 5.23 extern 96773 24193 HS 760 450 376 1354 12.97 5.89 extern 108942 27235 Heat value of heating oil: 35.5 MJ/l = 9.861 kwh/l 1 kw =1 MJ/h x 3.6 Heating efficiency: 0.7 Price of heating oil: 3 0.25 / l Calculation for an ASD 32: (usable heat energy: 16.4 kw Cost savings = 16.4 kw x 2000 h x 3 0.25 / l = 3 1188 0.7 x 9.861 kwh/l

Total electrical energy consumption 100% Heat radiated from the drive motor (dissipated into the cooling air) = 9% Heat recoverable from the fluid cooler = 72% Heat recoverable from the compressed air aftercooler = 13% Heat radiated from the compressor = 2% Heat remaining in the compressed air = 4% Total heat available for recovery = 94% Almost all the electrical energy consumed by a compressor is changed into heat. On screw compressors, approximately 94% of this heat is given up to the cooling system, approximately 4% remains in the compressed air and approximately 2% is radiated from the compressor into the immediate surroundings. Because the low cost of electricity used to be only a small part of operating costs, this wastage was of no great concern and few considered making practical use of the heat produced by compression. Only since the dramatic increase in electricity costs has the recovery of heat from a compressor become an important factor in the planning of an efficient air supply system. The basic principle lies in the transfer of the heat into a medium and then transporting it to where the heat can be utilised. Heat Flow Diagram The theoretical available heat of a screw compressor is 94% of the overall electrical energy consumption. It consists of heat dissipated in the fluid cooler (72%), the aftercooler (13%) and heat radiated from the drive motor (9%). An enclosed, air-cooled screw compressor with a precisely defined cooling air outlet would transfer the total amount into the cooling air for space heating. If water is to be heated, the oil in the fluid cooler is chosen as the transfer medium so that only 72% of the overall power consumption is available for water heating. If a combination of hot water and space heating is chosen then a maximum of 72% is available for water heating and at least 22% for space heating.

Worldwide sales and service network - KAESER is always nearby KAESER MOBILAIR portable compressor works KAESER headquarters Argentina Australia Austria Bahrain Bangladesh Belarus Belgium Brazil Bulgaria Canada Chile China Columbia Croatia Cyprus Czech Republic Denmark Egypt Eire Estonia Finland France Germany Greece Hungary Iceland India Indonesia Italy Japan Kenya Korea Latvia Lithuania Luxembourg Malaysia Mexico Morocco Netherlands Norway Pakistan Philippines Poland Portugal Qatar Romania Russia Saudi Arabia Singapore Slovakia Slovenia South Africa Spain Sri Lanka Sweden Switzerland Taiwan Thailand Tunisia Turkey UAE Ukraine United Kingdom USA Vietnam