Applications and Features

Similar documents
Weatherproof 14" x 12" x 7" Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners

SIMPLEX WEATHERPROOF CONTROL PANELS

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

SPECTRACOOL INDOOR/OUTDOOR

5736 N. Michigan Road Indianapolis, IN 46228

N Volt 1800 BTU/Hr. 527 Watt

5736 N. Michigan Road Indianapolis, IN 46228

UHD Heavy Duty Disconnect Enclosures - NEMA 12 ABB Controls, Allen Bradley, Cutler Hammer, General Electric, Siemens I-T-E Max-Flex, Square D

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Steel Casework Acid Storage

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

Accessory Products

PROAIR Harsh Environment/Wash Down Air Conditioners

GENESIS Indoor Air Conditioners

your dust explosion protection experts

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Installation Instructions

Model 4001 Series Single Channel Controller

LORAIN CIP 4890/48120 DC Power System

G /6000 BTU/Hr. 1172/1758 Watt

Professional Wi-Fi Installation Solutions

N Volt 1800 BTU/Hr. 527 Watt

Barnes Oil Sensor Switch

Innovative POWER Solutions

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Public Safety DAS Annunciator Panel

FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

PANELBOARD PROTECTION ON A GLOBAL SCALE

Elevator Sump Kits and Components

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

Installation Instructions

SECTION EXTERIOR LIGHTING

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

FTTX Fiber Optic Cabinet Package, Type 4X

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Introduction to Flow Switch

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

RF EMI PORTABLE ENCLOSURE OPTIONS. Vestibule / Foyer - internal or external. RMEC0004 Canvas Carry Bag for enclosures 40 x 20 x 20

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

Top-Mount Air Conditioners

Custom Duct Heaters. Special Applications

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

P126FTT Fiber Transfer Terminal

Custom Duct Heaters. Special Applications

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

SECTION SANITARY SEWAGE PUMP STATIONS

THERMAL MANAGEMENT SOLUTIONS

Model BX-903, BX-904 and BX-906 Environmental Enclosure For BAM-1020 Operation Manual

JDDT1 - Single Stage Digital Thermostat

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

Off-Grid CyboInverter Installation Guide. For CI-Mini-1200H Solar Mini-Inverter for Electric Water Heaters

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Paragon. Induced Draft, Counter Flow Optional Accessories

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

THERMAL MANAGEMENT SOLUTIONS

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Cabinet Cooler Systems

FC Series - NEMA 3R outdoor enclosures with UL Listed fans, filters, and thermostats. FC Series include fans NEW BW-FC20168 BW FC BW-124FC

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

SAFETY CABINETS & CANS WHEN SAFETY COUNTS

TELECOMMUNICATION. Telecommunication. Wireless Phone

TECHNICAL SPECIFICATION RESIDENTIAL GRINDER PUMP & BASIN.

TUNNELS BOXES AND CONNECTORS

General Specifications for Lighted Crosswalk Warning Equipment and Miscellaneous Materials, Rev 4

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

We ve Got Panels Under Control.

Access Point Mounting Instructions

Tubular Industrial Process

Principle of Operation:

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

SECTION AUTOMATIC TRANSFER SWITCHES

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Temperature Controllers

UDC 700 Universal Digital Controllers and Indicator Specifications

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

Fiber Distribution Box

VA G 052 S

Transcription:

120 VAC 18x16x8 Inch Weatherproof Enclosure with Mounting Plate, Cooling Fans, Heaters & Solid State Dual Point Temperature Controller Model: NB181608-1HFS Applications and Features Features: Molded Fiberglass Reinforced Polyester (FRP) industrial Enclosure Stainless steel quick release latches with padlock hasps NEMA Type 3R, 3RX / IP24 rated Fully gasketed raised Vented lid with removable filters & integral mounting flange Features aluminum mounting plate with surge protected duplex 120 VAC Outlets & Thermostat Controlled Heating & Cooling System Applications: Remote Wireless LAN WiFi equipment installations Indoor and outdoor installations Hot and Cold temperature environments Corrosive environments & hotspot applications Protection of equipment from theft or damage

Product Description Start with the Box... The box is a rugged 18" x 16" x 8" weatherproof enclosure that is ideal for both indoor and outdoor applications. Constructed from molded fiberglass, it is well suited for high temperature or corrosive environments. The mounting flange allows it to be wall mounted as well as on a flat surface. The box can also be pole mounted with the optional pole mounting hardware kit. The fully gasketed lid features a stainless steel continuous hinge and stainless steel quick release latches with padlock hasps. The enclosure material is UV stabilized and comes in machine tool gray. The enclosure also features holes for mounting Lightning Protectors or Connectors, a grounding lug and ½ cable conduit connector. Due to the large size of this enclosure, it can accommodate dual sets of most access points. The example to the right shows one of the many ways the enclosure can be configured. Mounting Plate The aluminum mounting plate has provisions to mount WLAN equipment from Cisco, Symbol, D-Link, HyperLink and more. With the optional HGX-AMOUNT02 bracket a wide array of HyperLink Amplifiers, Power-Over-Ethernet products and Power Supplies can be mounted as well. Two of these brackets can be mounted side by side. Also available is the HGX-NMOUNT03 Universal Mounting Shelf that can be attached to the mounting plate and can accommodate additional equipment to be placed in the enclosure. The plate features four standard surge protected 120 VAC outlets and a terminal strip to supply power to internal equipment. Hot and Cold Environments To help ensure trouble-free operation of electronic equipment, proper operating temperatures inside an enclosure needs to be maintained. With the built-in Heater and Cooling system, internal temperatures can be better maintained. This model is ideal in Hot and Cold environments. The NB181608-1HFS comes with two 120 VAC 200 watt heating elements and two 120 VAC cooling fans. The fans and heaters are controlled by HyperLink's exclusive solid-state temperature controller. The standard unit has a fan turn-on temperature of +93 F (+33.8 C) and a heat turn-on temperature of +16 F (-8.8 C). The controller features improved temperature setpoint accuracy and can be factory modified for other temperature setpoints. The heater and fan are controlled by two integral high current solid-state AC relays. The relays feature Zero Cross Detection for EMI reduction. No extra room for the controller is required since it is mounted underneath the plate. Lightning Protection Surge protection is provided as a standard feature on the internal AC outlets. In addition, the unit can accept up to two optional bulkhead-mount N-Type lightning protectors to protect the coaxial cable runs. Mounted to the optional HGX-AMOUNT02 bracket, the HGLN-CAT5 lightning protector can be used with Power-over-Ethernet applications.

Specifications Enclosure Material Fiberglass Reinforced Polyester Enclosure Color Machine Tool Gray Voltage 120 VAC Heater Power 200 Watts each (400 Watts total) Fan Power 12 Watts each (24 Watts total) Mounting Plate Material.10 in. (2.5mm) Thick Anodized Aluminum Mounting Plate Dimensions 16.8 x 14.8 inches (42.6 x 37.5 cm) Weight 21.8 lbs (9.9 kg) Outside Dimensions (max) 19.5 x 17.5 x 10 inches (49.5 x 44.4 x 25.4 cm) Inside Dimensions 17.7 x 15.7 x 8.5 inches (44.9 x 39.9 x 21.6 cm) Flame Rating UL 94-5V RoHS Compliant Yes Cable Feed 1/2 Cable Conduit Connector Ratings NEMA Type 3R, 3RX / IP24 Temperature Controller Specification Fan Setpoint Temperature +34 C (+93 F) Heater Setpoint Temperature -9 C (+16 F) Hysteresis Window 5 C (9 F) Contact us for custom Fan/Heat Setpoints

Enclosure Dimensions

Mounting Plate Details